Changes for page 13 HMI Internal Registers

Last modified by Jett on 2025/04/28 16:07

From version 16.3
edited by Hunter
on 2023/02/18 11:32
Change comment: There is no comment for this version
To version 33.1
edited by Mora Zhou
on 2023/11/21 16:25
Change comment: There is no comment for this version

Summary

Details

Page properties
Title
... ... @@ -1,1 +1,1 @@
1 -12 HMI internal registers
1 +13.HMI Internal Registers
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.Hunter
1 +XWiki.Mora
Content
... ... @@ -25,6 +25,11 @@
25 25  * The address of the bit address HDX is with a decimal point while word addresses are integers.
26 26  )))
27 27  
28 += Address ranges table =
29 +
30 +(% style="text-align:center" %)
31 +[[image:6.png]]
32 +
28 28  = **Data storage area (HDW/HDX)** =
29 29  
30 30  It is used to save the temporary data of project.
... ... @@ -51,21 +51,27 @@
51 51  
52 52  It is system recipe data power-off save register. The range is from RPW000000 to RPW990450.
53 53  
59 +(% class="box infomessage" %)
60 +(((
54 54  **✎Note:**
55 55  
56 56  * RPW is power-down retention. The register of this type is able to save the data before the power-down.
57 57  * To avoid possible device failure, do not immediately power off and reboot when configuring the power-down save addre
65 +)))
58 58  
59 59  = **Single user data area (HUW/HUX)** =
60 60  
61 61  It is used for system special registers (reserved by system).
62 62  
63 -1. Access as word, and serial number range is from HUW0 to HUW199999.
64 -1. Access as bit, and serial number range is from HUX0.0 to HUX199999.15.
71 +1. Access as word, and serial number range is from HUW0 to HUW1599.
72 +1. Access as bit, and serial number range is from HUX0.0 to HUX1599.15.
65 65  
74 +(% class="box infomessage" %)
75 +(((
66 66  **✎Note:**
67 67  
68 68  * HUW/HUX is a system special register, so please check the system special register list during use. Please use the address specified in the table and do not use the address which is not mentioned in the table.
79 +)))
69 69  
70 70  (% class="table-bordered" %)
71 71  |=**Special register address**|=**Description**|=**Function**
... ... @@ -127,16 +127,19 @@
127 127  1. Access as word, and serial number range is from HSW0 to HSW49999. (HSW10000 to HSW19999 are the power-off storage areas)
128 128  1. Access as bit, and serial number range is from HSX0.0 to HSX49999.15.
129 129  
141 +(% class="box infomessage" %)
142 +(((
130 130  **✎Note:**
131 131  
132 132  * HSW / HSX are a system special register, so please check the system special register list during use. Please use the address specified in the table and do not use the address which is not mentioned in the table.
133 133  * To avoid possible device failure, do not immediately power off and reboot when configuring the power-down save address.
147 +)))
134 134  
135 135  (% class="table-bordered" style="width:1024px" %)
136 136  |=(% scope="row" style="width: 160px;" %)**Address**|=(% style="width: 282px;" %)**Function**|=(% style="width: 452px;" %)**Description**
137 137  |=(% style="width: 160px;" %)HSW0|(% style="width:282px" %)Language switch|(% style="width:452px" %)Multiple language could be set in the project, HMI support maximum 8 languages. (Power-down save supported)
138 -|=(% style="width: 160px;" %)HSW1|(% style="width:282px" %)Beep frequency|(% style="width:452px" %)Frequency range: 0~~4000
139 -|=(% style="width: 160px;" %)HSW2|(% style="width:282px" %)Beep volume|(% style="width:452px" %)Volume range: 0~~80
152 +|=(% style="width: 160px;" %)HSW1|(% style="width:282px" %)Beep frequency (Only valid in HMI V1.0 System)|(% style="width:452px" %)Frequency range: 0~~4000
153 +|=(% style="width: 160px;" %)HSW2|(% style="width:282px" %)Beep volume (Only valid in HMI V1.0 System)|(% style="width:452px" %)Volume range: 0~~80
140 140  |=(% style="width: 160px;" %)HSW3|(% style="width:282px" %)Beep time|(% style="width:452px" %)Unit: ms
141 141  |=(% style="width: 160px;" %)HSW4|(% style="width:282px" %)Beep whether enable or not|(% style="width:452px" %)(((
142 142  * =0: Enable.
... ... @@ -150,7 +150,7 @@
150 150  )))
151 151  |=(% style="width: 160px;" %)HSW6~~HSW7|(% style="width:282px" %)Number of alarms|(% style="width:452px" %)The number of alarm (it also includes the records of alarm confirmed)
152 152  |=(% style="width: 160px;" %)HSW8|(% style="width:282px" %)Number of unconfirmed history alarm|(% style="width:452px" %)The number of unconfirmed history alarm
153 -|=(% style="width: 160px;" %)HSW9|(% style="width:282px" %)Time out tip|(% style="width:452px" %)(((
167 +|=(% style="width: 160px;" %)HSW9|(% style="width:282px" %)Time out prompt|(% style="width:452px" %)(((
154 154  * =0: Enable
155 155  * =1: Disable
156 156  )))
... ... @@ -175,12 +175,16 @@
175 175  * =5: Friday.
176 176  * =6: Saturday.
177 177  )))
192 +|=(% style="width: 160px;" %)HSW39|(% style="width:282px" %)Beep type(Only valid in HMI V2.0 System)|(% style="width:452px" %)Type range: 1-5, Default is 1.
178 178  |=(% style="width: 160px;" %)HSW134|(% style="width:282px" %)(((
179 179  Whether the Script is read through
180 180  
181 181  
182 182  )))|(% style="width:452px" %)(((
198 +(% class="box infomessage" %)
199 +(((
183 183  **✎Note:** If want to read-only or write-only, please enable this settings.
201 +)))
184 184  
185 185  * =0: Read from HMI cache(Default)
186 186  * =1: Read from PLC directly
... ... @@ -291,7 +291,7 @@
291 291  * =2: Ejecting SD card, please waiting…
292 292  * =3: SD card ejected
293 293  )))
294 -|=(% style="width: 160px;" %)HSW550~~849|(% style="width:282px" %)Communication control|(% style="width:452px" %)For communication control and communication lamp (please refer to "[[communication control>>http://13.229.109.52:8080/wiki/pistudio/view/Helps/13.HMI%20internal%20registers/#HCommunicationcontrol]]" sector for detailed)
312 +|=(% style="width: 160px;" %)HSW550~~849|(% style="width:282px" %)Communication control|(% style="width:452px" %)For communication control and communication lamp (please refer to "[[Communication control>>http://13.229.109.52:8080/wiki/pistudio/view/Helps/13.HMI%20internal%20registers/#HCommunicationcontrol]]" sector for detailed)
295 295  |=(% style="width: 160px;" %)HSW850|(% style="width:282px" %)(((
296 296  Network state
297 297  
... ... @@ -340,15 +340,15 @@
340 340  * HDX882.1=1 SD card is reading data, don't remove SD card.
341 341  )))
342 342  |=(% style="width: 160px;" %)HSW884|(% style="width:282px" %)Enter the system network configuration interface|(% style="width:452px" %)(((
343 -* =0: Do not enter the network configuration interface
344 -* =1: Enter the system network configuration interface.
361 +* = 0: Do not enter the network configuration interface
362 +* = 1: Enter the system network configuration interface.
345 345  ** ig series HMI only supports to enter the system interface
346 346  
347 347  )))
348 348  |=(% style="width: 160px;" %)HSW885|(% style="width:282px" %)When the control object hides the address is read failed (communication failure), set the display mode of the object|(% style="width:452px" %)(((
349 349  * = 0: displayed by object setting.
350 -* =1: control address read failure, the address control of all objects is hidden, not displayed.
351 -* =2: control address read failure, the address control of all objects is displayed, not hidden.
368 +* = 1: control address read failure, the address control of all objects is hidden, not displayed.
369 +* = 2: control address read failure, the address control of all objects is displayed, not hidden.
352 352  )))
353 353  |=(% style="width: 160px;" %)HSW893|(% style="width:282px" %)(((
354 354  User Permission Control Address, same as HUW1000 feature, please refer to chapter "[[User Permission>>http://13.229.109.52:8080/wiki/pistudio/view/Helps/08.Basic%20Function/#HUserPermission]]"
... ... @@ -371,7 +371,7 @@
371 371  |=(% style="width: 160px;" %)HSW900|(% style="width:282px" %)Quick update frequency settings for objects|(% style="width:452px" %)(((
372 372  Valid when the object is enabled for "quick update". Default: 5.
373 373  
374 -Range: 1 (fastest) ~~ 50 (slowest)
392 +Range: 1 (fastest) - 50 (slowest)
375 375  )))
376 376  |=(% style="width: 160px;" %)HSW920|(% style="width:282px" %)Static mode Maximum periods|(% style="width:452px" %)Numeric Input/ Display (range: 0-12)
377 377  |=(% style="width: 160px;" %)HSW921 ~~ 924|(% style="width:282px" %)Static mode Admin key|(% style="width:452px" %)Character Input/ Display (length: 8)
... ... @@ -421,8 +421,11 @@
421 421  |=(% style="width: 160px;" %)HSW1070|(% style="width:282px" %)The time interval (seconds) since the last time the screen was clicked|(% style="width:452px" %)(((
422 422  Shows how long the current screen has not been clicked, using a decimal unsigned double word (Numeric Input/ Display).
423 423  
442 +(% class="box infomessage" %)
443 +(((
424 424  **✎Note: **This register is cleared to zero regardless of which user clicks on the screen.
425 425  )))
446 +)))
426 426  |=(% style="width: 160px;" %)HSW1073|(% style="width:282px" %)Corresponding key value from keyboard|(% style="width:452px" %)Display the key value of the currently pressed key, the key value is shown in Table 1 (not updated when the character input display is being input)
427 427  |=(% style="width: 160px;" %)HSW1074|(% style="width:282px" %)Keyboard key status|(% style="width:452px" %)Display the current button status (not updated when the numeric input display is being input)(((
428 428  * =0: key release
... ... @@ -450,7 +450,7 @@
450 450  Address mapping polling cycle, effective range: 40~~1000ms, default: 300ms.
451 451  
452 452  * When the set value is greater than 1000, the value is 1000.
453 -* When the set value is greater than 1000, it changes to the default value 300
474 +* When the set value is lower than 40, it changes to the default value 300
454 454  )))
455 455  |=(% style="width: 160px;" %)HSW1087|(% style="width:282px" %)Control write interval in address mapping|(% style="width:452px" %)(((
456 456  After reading data to the device for N times, Perform an address mapping write operation. N is the interval value. The effective range: 0~~5, and default is 2.
... ... @@ -593,7 +593,7 @@
593 593  * =0: Server connection exception
594 594  * =1: Server connection is OK
595 595  )))
596 -|=(% style="width: 160px;" %)HSW1740|(% style="width:282px" %)Wi-fi signal signal strength|(% style="width:452px" %)(((
617 +|=(% style="width: 160px;" %)HSW1740|(% style="width:282px" %)Wi-fi signal strength|(% style="width:452px" %)(((
597 597  Display the value of Wi-fi signal signal strength, ranges from 0~~100 (Signal strength is automatically obtained only once when HMI is powered on, and it will not be automatically updated. It needs to be used with the HSW1890)
598 598  )))
599 599  |=(% style="width: 160px;" %)HSW1741|(% colspan="1" rowspan="12" style="width:282px" %)Related IP register in 4Gnetwork status (It is valid when HMI is connected to 4G)|(% style="width:452px" %)Local IP address high byte 1
... ... @@ -825,7 +825,7 @@
825 825  )))
826 826  |=(% style="width: 160px;" %)HSW1866|(% style="width:282px" %)Delete the Lua extension module file|(% style="width:452px" %)(((
827 827  * =0: delete;
828 -* = Others value: do not delete
849 +* = Others: do not delete
829 829  )))
830 830  |=(% style="width: 160px;" %)HSW1867|(% style="width:282px" %)Reset mode|(% style="width:452px" %)(((
831 831  Monitor address is set during reset of reset switch, whether to cancel reset,
... ... @@ -892,13 +892,22 @@
892 892  |=(% style="width: 160px;" %)(((
893 893  HSW1879
894 894  )))|(% style="width:452px" %)Ethernet1 Local DNS2 address high byte 4
916 +|=(% style="width: 160px;" %)HSW1890|(% colspan="1" style="width:282px" %)Enable refresh current network signal|(% style="width:452px" %)(((
917 +* =1: Refresh the network signal once after triggered (This register will be automatically reset after triggered, only update the signal value once after per 15 seconds, not able to update twice in the short interval)
918 +* =Others: not refresh
919 +)))
920 +|=(% style="width: 160px;" %)HSW1891|(% colspan="1" style="width:282px" %)Enable clear cache for screen data  |(% style="width:452px" %)(((
921 +* =1, not clear screen cache when switch language
922 +* =2, trigger clear cache of all screens for once time
923 +* =3, always clear cache of all screen data
924 +)))
895 895  |=(% style="width: 160px;" %)HSW10000~~19999|(% style="width:282px" %)Power-down storage area|(% style="width:452px" %)After restart, the data remains
896 896  |=(% style="width: 160px;" %)HSW10035|(% rowspan="13" style="width:282px" %)(((
897 897  Note: Valid when Ethernet1 of HMI is plugged into the network cable.
898 -①When the Ethernet setting is enabled in the project parameters, this register displays the set value.
899 -②. When the Ethernet setting is not enabled in the engineering parameters, the register displays the Ethernet IP automatically acquired by the HMI.
900 -③. When the HMI is not plugged into the network cable, the register will show 0 whether the engineering parameters are set or not.
901 -④.IP related registers can be read and written (only static IP mode can be written).
928 +① When the Ethernet setting is enabled in the project parameters, this register displays the set value.
929 +② When the Ethernet setting is not enabled in the engineering parameters, the register displays the Ethernet IP automatically acquired by the HMI.
930 +③ When the HMI is not plugged into the network cable, the register will show 0 whether the engineering parameters are set or not.
931 +④ IP related registers can be read and written (only static IP mode can be written).
902 902  )))|(% style="width:452px" %)Local IP address high byte 1
903 903  |=(% style="width: 160px;" %)HSW10036|(% style="width:452px" %)Local IP address high byte 2
904 904  |=(% style="width: 160px;" %)HSW10037|(% style="width:452px" %)Local IP address high byte 3
... ... @@ -992,6 +992,7 @@
992 992  * =0: LAN or the external network both OK
993 993  * =1: Only LAN access
994 994  * =2: Only external network can access
1025 +* =3: Close the functions
995 995  )))
996 996  |=(% style="width: 160px;" %)HSW11757|(% style="width:282px" %)Enable the valid date of the dynamic installment password|(% style="width:452px" %)(((
997 997  * =0: Disabled
6.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Mora
Size
... ... @@ -1,0 +1,1 @@
1 +20.1 KB
Content