Changes for page 13 HMI Internal Registers

Last modified by Jett on 2025/04/28 16:07

From version 16.3
edited by Hunter
on 2023/02/18 11:32
Change comment: There is no comment for this version
To version 4.6
edited by Stone Wu
on 2022/08/06 14:21
Change comment: There is no comment for this version

Summary

Details

Page properties
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.Hunter
1 +XWiki.Stone
Content
... ... @@ -4,11 +4,11 @@
4 4  
5 5  *HSW, HDW, HUW, HAW are word address, HSX, HDX, HUX, HAX are bit address.
6 6  
7 -* **System data area (HSW): **A special register defined by the system.
8 -* **Data storage area (HDW/HDX): **Users store user data.
9 -* **System data area (HUW): **A special register defined by the system.
10 -* **System Data (HAW)**: System register used for power-off save.
11 -* **Recipe index area (RPW): **System register used for recipe index.
7 +1. **System data area (HSW): **A special register defined by the system.
8 +1. **Data storage area (HDW/HDX): **Users store user data.
9 +1. **System data area (HUW): **A special register defined by the system.
10 +1. **System Data (HAW)**: System register used for power-off save.
11 +1. **Recipe index area (RPW): **System register used for recipe index.
12 12  
13 13  HMI internal registers are divided into bit address and word address, which can be accessed in two ways (take HDW as an example).
14 14  
... ... @@ -241,8 +241,8 @@
241 241  * =2: HSX521.1=1, delete all trend graph.
242 242  * =4: HSX521.2=1, delete all alarms.
243 243  * =16: HSX521.4=1, delete history XY plot.
244 -* =32: HSX521.5=1, delete data records in SD card or USB flash disk;(Please make a setting which is saved to USB flash disk or SD card in project setting).
245 -* =64: HSX521.6=1, delete alarms records in SD card or USB flash disk; (Please make a setting which is saved to USB flash disk or SD card in project setting).
244 +* =32: HSX521.5=1, delete data records in SD card or flash dish;(Please make a setting which is saved to flash disk or SD card in project setting).
245 +* =64: HSX521.6=1, delete alarms records in SD card or flash dish; (Please make a setting which is saved to flash disk or SD card in project setting).
246 246  )))
247 247  |=(% style="width: 160px;" %)HSW522|(% style="width:282px" %)Copy and paste the alarm/data files in flash to the USB flash disk|(% style="width:452px" %)(((
248 248  * =0: No operation
... ... @@ -485,8 +485,6 @@
485 485  * =0, Default value
486 486  * =1, Release the alarm generated before the last power-down when starting up
487 487  )))
488 -|=(% style="width: 160px;" %)HSW1200|(% colspan="1" rowspan="2" style="width:282px" %)TSAP settings for HMI in the Siemens LOGO! 8 protocol(ig series or HMI V2.0)|(% style="width:452px" %)HMI local TSAP, which corresponds to the remote TSAP of PLC
489 -|=(% style="width: 160px;" %)HSW1201|(% style="width:452px" %)HMI remote TSAP, which corresponds to the local TSAP of PLC
490 490  |=(% style="width: 160px;" %)HSW1450|(% style="width:282px" %)Enable objects level password function|(% style="width:452px" %)(((
491 491  * =0, Disable
492 492  * =1, Enable
... ... @@ -593,9 +593,6 @@
593 593  * =0: Server connection exception
594 594  * =1: Server connection is OK
595 595  )))
596 -|=(% style="width: 160px;" %)HSW1740|(% style="width:282px" %)Wi-fi signal signal strength|(% style="width:452px" %)(((
597 -Display the value of Wi-fi signal signal strength, ranges from 0~~100 (Signal strength is automatically obtained only once when HMI is powered on, and it will not be automatically updated. It needs to be used with the HSW1890)
598 -)))
599 599  |=(% style="width: 160px;" %)HSW1741|(% colspan="1" rowspan="12" style="width:282px" %)Related IP register in 4Gnetwork status (It is valid when HMI is connected to 4G)|(% style="width:452px" %)Local IP address high byte 1
600 600  |=(% style="width: 160px;" %)HSW1742|(% style="width:452px" %)Local IP address high byte 2
601 601  |=(% style="width: 160px;" %)HSW1743|(% style="width:452px" %)Local IP address high byte 3
... ... @@ -623,180 +623,10 @@
623 623  * =1: Server connection is OK
624 624  )))
625 625  |=(% style="width: 160px;" %)HSW1761|(% style="width:282px" %)Display 4G network signal strength|(% style="width:452px" %)Signal strength: 0~~31. The greater the value ,the signal is stronger
626 -|=(% style="width: 160px;" %)(((
627 -HSW1762
628 -)))|(% colspan="1" rowspan="13" style="width:282px" %)(((
629 -Note: Valid when Ethernet2 of HMI is plugged into the network cable.
630 -①、When the Ethernet setting is enabled in the project parameters, this register displays the set value.
631 -②. When the Ethernet setting is not enabled in the engineering parameters, the register displays the Ethernet IP automatically acquired by the HMI.
632 -③. When the HMI is not plugged into the network cable, the register will show 0 whether the engineering parameters are set or not.
633 -④.IP related registers can be read and written (only static IP mode can be written).
634 -)))|(% style="width:452px" %)(((
635 -Ethernet2 Local IP address high byte 1
636 -)))
637 -|=(% style="width: 160px;" %)(((
638 -HSW1763
639 -)))|(% style="width:452px" %)(((
640 -Ethernet2 Local IP address high byte 2
641 -)))
642 -|=(% style="width: 160px;" %)(((
643 -HSW1764
644 -)))|(% style="width:452px" %)(((
645 -Ethernet2 Local IP address high byte 3
646 -)))
647 -|=(% style="width: 160px;" %)(((
648 -HSW1765
649 -)))|(% style="width:452px" %)(((
650 -Ethernet2 Local IP address high byte 4
651 -)))
652 -|=(% style="width: 160px;" %)(((
653 -HSW1766
654 -)))|(% style="width:452px" %)(((
655 -Ethernet2 Local mask IP address high byte 1
656 -)))
657 -|=(% style="width: 160px;" %)(((
658 -HSW1767
659 -)))|(% style="width:452px" %)(((
660 -Ethernet2 Local mask IP address high byte 2
661 -)))
662 -|=(% style="width: 160px;" %)(((
663 -HSW1768
664 -)))|(% style="width:452px" %)Ethernet2 Local mask IP address high byte 3
665 -|=(% style="width: 160px;" %)HSW1769|(% style="width:452px" %)Ethernet2 Local mask IP address high byte 4
666 -|=(% style="width: 160px;" %)(((
667 -HSW1770
668 -)))|(% style="width:452px" %)(((
669 -Ethernet2 Local gateway IP address high byte 1
670 -)))
671 -|=(% style="width: 160px;" %)(((
672 -HSW1771
673 -)))|(% style="width:452px" %)(((
674 -Ethernet2 Local gateway IP address high byte 2
675 -)))
676 -|=(% style="width: 160px;" %)(((
677 -HSW1772
678 -)))|(% style="width:452px" %)(((
679 -Ethernet2 Local gateway IP address high byte 3
680 -)))
681 -|=(% style="width: 160px;" %)(((
682 -HSW1773
683 -)))|(% style="width:452px" %)(((
684 -Ethernet2 Local gateway IP address high byte 4
685 -)))
686 -|=(% style="width: 160px;" %)(((
687 -HSW1774
688 -)))|(% style="width:452px" %)(((
689 -Ethernet2 Local Port Address
690 -)))
691 -|=(% style="width: 160px;" %)(((
692 -HSW1775
693 -)))|(% colspan="1" rowspan="6" style="width:282px" %)(((
694 -①Display the MAC code of Ethernet2 NIC
695 -
696 -(hexadecimal display)
697 -
698 -②Read-only mode, not modifiable
699 -)))|(% style="width:452px" %)(((
700 -Ethernet2 Local MAC code high byte 1
701 -)))
702 -|=(% style="width: 160px;" %)(((
703 -HSW1776
704 -)))|(% style="width:452px" %)(((
705 -Ethernet2 Local MAC code high byte 2
706 -)))
707 -|=(% style="width: 160px;" %)(((
708 -HSW1777
709 -)))|(% style="width:452px" %)(((
710 -Ethernet2 Local MAC code high byte 3
711 -)))
712 -|=(% style="width: 160px;" %)(((
713 -HSW1778
714 -)))|(% style="width:452px" %)(((
715 -Ethernet2 Local MAC code high byte 4
716 -)))
717 -|=(% style="width: 160px;" %)(((
718 -HSW1779
719 -)))|(% style="width:452px" %)(((
720 -Ethernet2 Local MAC code high byte 5
721 -)))
722 -|=(% style="width: 160px;" %)(((
723 -HSW1780
724 -)))|(% style="width:452px" %)(((
725 -Ethernet2 Local MAC code high byte 6
726 -)))
727 -|=(% style="width: 160px;" %)(((
728 -HSW1781
729 -)))|(% colspan="1" rowspan="8" style="width:282px" %)(((
730 -①Display and modify DNS1 and DNS2 of Ethernet2
731 -
732 -②Related registers can be read and written mode (only static IP mode can be written)
733 -)))|(% style="width:452px" %)(((
734 -Ethernet2 Local DNS1 address high byte 1
735 -)))
736 -|=(% style="width: 160px;" %)(((
737 -HSW1782
738 -)))|(% style="width:452px" %)(((
739 -Ethernet2 Local DNS1 address high byte 2
740 -)))
741 -|=(% style="width: 160px;" %)(((
742 -HSW1783
743 -)))|(% style="width:452px" %)(((
744 -Ethernet2 Local DNS1 address high byte 3
745 -)))
746 -|=(% style="width: 160px;" %)(((
747 -HSW1784
748 -)))|(% style="width:452px" %)(((
749 -Ethernet2 Local DNS1 address high byte 4
750 -)))
751 -|=(% style="width: 160px;" %)(((
752 -HSW1785
753 -)))|(% style="width:452px" %)(((
754 -Ethernet2 Local DNS2 address high byte 1
755 -)))
756 -|=(% style="width: 160px;" %)(((
757 -HSW1786
758 -)))|(% style="width:452px" %)(((
759 -Ethernet2 Local DNS2 address high byte 2
760 -)))
761 -|=(% style="width: 160px;" %)(((
762 -HSW1787
763 -)))|(% style="width:452px" %)(((
764 -Ethernet2 Local DNS2 address high byte 3
765 -)))
766 -|=(% style="width: 160px;" %)(((
767 -HSW1788
768 -)))|(% style="width:452px" %)(((
769 -Ethernet2 Local DNS2 address high byte 4
770 -)))
771 -|=(% style="width: 160px;" %)(((
772 -HSW1789
773 -)))|(% colspan="1" style="width:282px" %)(((
774 -Display or set the dynamic or static IP mode of Ethernet2
775 -)))|(% style="width:452px" %)(((
776 -HSX1789.0 = 0, Static IP mode
777 -
778 -HSX1789.0 = 1, dynamic IP mode
779 -)))
780 -|=(% style="width: 160px;" %)(((
781 -HSW1790
782 -)))|(% colspan="1" style="width:282px" %)(((
783 -Confirm Ethernet2 IP, subnet mask, gateway, DNS1, DNS2, and dynamic static IP settings
784 -)))|(% style="width:452px" %)(((
785 -~= 1, confirm the setting (i.e., after modifying IP-related information, set this address to 1, representing confirmation of the modification, after which it will be reset to 0)
786 -)))
787 -|=(% style="width: 160px;" %)(((
788 -HSW1791
789 -)))|(% colspan="1" style="width:282px" %)(((
790 -Network status of the Ethernet2 connection server
791 -)))|(% style="width:452px" %)(((
792 -~= 0, connection to the server is abnormal = 1, connection to the server is normal
793 -)))
794 794  |=(% style="width: 160px;" %)HSW1852|(% style="width:282px" %)Control the interval in two consecutive clicks|(% style="width:452px" %)Limit range: 1~~500ms. The default is 100 ms.
795 795  |=(% style="width: 160px;" %)HSW1853|(% style="width:282px" %)File format for exporting data records to USB flash drive or SD card|(% style="width:452px" %)(((
796 796  * =0: db database
797 797  * =1: CSV
798 -
799 -(Only valid for script function DbToCsvFile)
800 800  )))
801 801  |=(% style="width: 160px;" %)HSW1854|(% style="width:282px" %)High and low word conversion type|(% style="width:452px" %)(((
802 802  * =0: use the old high-low word conversion (default)
... ... @@ -818,87 +818,30 @@
818 818  * =1: download firmware
819 819  * =2: enter the background
820 820  )))
821 -|=(% style="width: 160px;" %)HSW1865|(% style="width:282px" %)Priority connection to the cloud|(% style="width:452px" %)(((
822 -* =0: priority Ethernet
823 -* =1: priority WLAN
824 -* =2: priority 4G
646 +|=(% style="width: 160px;" %)HSW1866|(% style="width:282px" %)Delete the LUa extension module file|(% style="width:452px" %)(((
647 +* =1, delete;
648 +* = Others, do not delete
825 825  )))
826 -|=(% style="width: 160px;" %)HSW1866|(% style="width:282px" %)Delete the Lua extension module file|(% style="width:452px" %)(((
827 -* =0: delete;
828 -* = Others value: do not delete
829 -)))
830 830  |=(% style="width: 160px;" %)HSW1867|(% style="width:282px" %)Reset mode|(% style="width:452px" %)(((
831 831  Monitor address is set during reset of reset switch, whether to cancel reset,
832 832  
833 -* = 0: yes (default);
834 -* = 1: no
653 +* = 0, yes (default);
654 +* = 1, no
835 835  )))
836 836  |=(% style="width: 160px;" %)HSW1868|(% style="width:282px" %)Double-click or long press the record type table mode|(% style="width:452px" %)(((
837 837  Controls whether the button pops up when double-clicking or long pressing on record type table object
838 838  
839 -* = 0: yes (default);
840 -* = 1: no
659 +* = 0, yes (default);
660 +* = 1, no
841 841  )))
842 -|=(% style="width: 160px;" %)(((
843 -HSW1869
844 -)))|(% style="width:282px" %)(((
845 -Dynamic screensaver countdown
846 -)))|(% style="width:452px" %)(((
847 -Countdown to enter dynamic screensaver effect, unit (S)
848 -)))
849 -|=(% style="width: 160px;" %)(((
850 -HSW1870
851 -)))|(% style="width:282px" %)(((
852 -Display or set the dynamic or static IP mode of Ethernet1
853 -)))|(% style="width:452px" %)(((
854 -HSX1870.0 = 0, Static IP mode
855 -
856 -HSX1870.0 = 1, dynamic IP mode
857 -)))
858 -|=(% style="width: 160px;" %)(((
859 -HSW1871
860 -)))|(% style="width:282px" %)(((
861 -Confirm the IP, subnet mask, gateway, DNS1, DNS2, and dynamic static IP settings for Ethernet1
862 -)))|(% style="width:452px" %)(((
863 -~= 1, confirm the setting (i.e., after modifying IP-related information, set this address to 1, representing confirmation of the modification, after which it will be reset to 0)
864 -)))
865 -|=(% style="width: 160px;" %)(((
866 -HSW1872
867 -)))|(% colspan="1" rowspan="8" style="width:282px" %)(((
868 -①Display and modify DNS1 and DNS2 of Ethernet1
869 -
870 -②Related registers can be read and written mode (only static IP mode can be written)
871 -)))|(% style="width:452px" %)(((
872 -Ethernet1 Local DNS1 address high byte 1
873 -)))
874 -|=(% style="width: 160px;" %)(((
875 -HSW1873
876 -)))|(% style="width:452px" %)Ethernet1 Local DNS1 address high byte 2
877 -|=(% style="width: 160px;" %)(((
878 -HSW1874
879 -)))|(% style="width:452px" %)Ethernet1 Local DNS1 address high byte 3
880 -|=(% style="width: 160px;" %)(((
881 -HSW1875
882 -)))|(% style="width:452px" %)Ethernet1 Local DNS1 address high byte 4
883 -|=(% style="width: 160px;" %)(((
884 -HSW1876
885 -)))|(% style="width:452px" %)Ethernet1 Local DNS2 address high byte 1
886 -|=(% style="width: 160px;" %)(((
887 -HSW1877
888 -)))|(% style="width:452px" %)Ethernet1 Local DNS2 address high byte 2
889 -|=(% style="width: 160px;" %)(((
890 -HSW1878
891 -)))|(% style="width:452px" %)Ethernet1 Local DNS2 address high byte 3
892 -|=(% style="width: 160px;" %)(((
893 -HSW1879
894 -)))|(% style="width:452px" %)Ethernet1 Local DNS2 address high byte 4
895 895  |=(% style="width: 160px;" %)HSW10000~~19999|(% style="width:282px" %)Power-down storage area|(% style="width:452px" %)After restart, the data remains
896 896  |=(% style="width: 160px;" %)HSW10035|(% rowspan="13" style="width:282px" %)(((
897 -Note: Valid when Ethernet1 of HMI is plugged into the network cable.
898 -①、When the Ethernet setting is enabled in the project parameters, this register displays the set value.
899 -②. When the Ethernet setting is not enabled in the engineering parameters, the register displays the Ethernet IP automatically acquired by the HMI.
900 -③. When the HMI is not plugged into the network cable, the register will show 0 whether the engineering parameters are set or not.
901 -④.IP related registers can be read and written (only static IP mode can be written).
664 +**✎Note: **Only valid when the HMI is plugged into the Ethernet cable.
665 +
666 +1. If Ethernet settings is enabled in project parameters, this register displays the set value.
667 +1. If Ethernet settings is not enabled in project parameters, IP would automatically obtained IP.
668 +1. If HMI is not connected to the network, the register is displayed as 0 whether the engineering parameters are set.
669 +1. 4. All IP registers of HMI are read-only.
902 902  )))|(% style="width:452px" %)Local IP address high byte 1
903 903  |=(% style="width: 160px;" %)HSW10036|(% style="width:452px" %)Local IP address high byte 2
904 904  |=(% style="width: 160px;" %)HSW10037|(% style="width:452px" %)Local IP address high byte 3
... ... @@ -913,11 +913,9 @@
913 913  |=(% style="width: 160px;" %)HSW10046|(% style="width:452px" %)Local gateway address high byte 4
914 914  |=(% style="width: 160px;" %)HSW10047|(% style="width:452px" %)Local port address
915 915  |=(% style="width: 160px;" %)HSW10048|(% rowspan="6" style="width:282px" %)(((
916 -Display the MAC code of Ethernet1 NIC
684 +Displays the MAC code of the current network card
917 917  
918 -(hexadecimal display)
919 -
920 -②Read-only mode, not modifiable
686 +(Hexadecimal display)
921 921  )))|(% style="width:452px" %)Local MAC code high word 1
922 922  |=(% style="width: 160px;" %)HSW10049|(% style="width:452px" %)Local MAC code high word 2
923 923  |=(% style="width: 160px;" %)HSW10050|(% style="width:452px" %)Local MAC code high word 3
... ... @@ -924,7 +924,7 @@
924 924  |=(% style="width: 160px;" %)HSW10051|(% style="width:452px" %)Local MAC code high word 4
925 925  |=(% style="width: 160px;" %)HSW10052|(% style="width:452px" %)Local MAC code high word 5
926 926  |=(% style="width: 160px;" %)HSW10053|(% style="width:452px" %)Local MAC code high word 6
927 -|=(% style="width: 160px;" %)HSW10118|(% colspan="1" rowspan="2" style="width:282px" %)TSAP settings for HMI in the Siemens LOGO! 8 protocol|(% style="width:452px" %)HMI local TSAP, which corresponds to the remote TSAP of PLC
693 +|=(% style="width: 160px;" %)HSW10118|(% colspan="1" rowspan="2" style="width:282px" %)TSAP settings for HMI in the Siemens logo! 8 protocol|(% style="width:452px" %)HMI local TSAP, which corresponds to the remote TSAP of PLC
928 928  |=(% style="width: 160px;" %)HSW10119|(% style="width:452px" %)HMI remote TSAP, which corresponds to the local TSAP of PLC
929 929  |=(% style="width: 160px;" %)HSW10461~~10493|(% style="width:282px" %)Remote access password|(% style="width:452px" %)8-character remote access password
930 930  |=(% style="width: 160px;" %)HSW10494~~10558|(% style="width:282px" %)Machine ID (Read only)|(% style="width:452px" %)Machine ID for remote access (read only 64-bit)
... ... @@ -1006,38 +1006,11 @@
1006 1006  )))
1007 1007  |=(% style="width: 160px;" %)HSW11760|(% style="width:282px" %)Screensaver countdown|(% style="width:452px" %)Display the countdown to enter the Screensaver, unit: second.
1008 1008  |=(% style="width: 160px;" %)HSW11761|(% style="width:282px" %)Screensaver screen number|(% style="width:452px" %)Set the screen number for Screensaver
1009 -|=(% style="width: 160px;" %)(((
1010 -HSW11762
1011 -)))|(% style="width:282px" %)(((
1012 -Dynamic screensaver control address
1013 -)))|(% style="width:452px" %)(((
1014 -HSX11762.0=0, initialize with project configuration;
1015 1015  
1016 -HSX11762.0=1, initialize with special register configuration;
776 +== **Serial port communication configuration** ==
1017 1017  
1018 -HSX11762.1=0, disable dynamic screensaver;
1019 -
1020 -HSX11762.1=1, enable dynamic screensaver
1021 -)))
1022 -|=(% style="width: 160px;" %)(((
1023 -HSW11763
1024 -)))|(% style="width:282px" %)(((
1025 -Waiting time to enter the dynamic screensaver
1026 -)))|(% style="width:452px" %)(((
1027 -Waiting time when the screen is not operated, range 1~~720 minutes
1028 -)))
1029 -|=(% style="width: 160px;" %)(((
1030 -HSW11764
1031 -)))|(% style="width:282px" %)(((
1032 -Animated screensaver animation type
1033 -)))|(% style="width:452px" %)(((
1034 -~=0: Raster,=1: Blinds,=2: Bubble
1035 -)))
1036 -
1037 -== Serial port communication configuration ==
1038 -
1039 1039  (% class="table-bordered" %)
1040 -|=(% scope="row" style="width: 102px;" %)Port|=(% style="width: 173px;" %)**Function**|=(% style="width: 122px;" %)**Address**|=(% colspan="2" style="width: 506px;" %)**Description**
779 +|=(% style="width: 102px;" %)Port|=(% style="width: 173px;" %)**Function**|=(% style="width: 122px;" %)**Address**|=(% colspan="2" style="width: 506px;" %)**Description**
1041 1041  |(% colspan="1" rowspan="11" style="width:102px" %)COM1|(% style="width:173px" %)Communication mode|(% style="width:122px" %)HSW10061|(% colspan="2" style="width:506px" %)(((
1042 1042  * =0: RS232
1043 1043  * =1: RS485
... ... @@ -1067,22 +1067,10 @@
1067 1067  * =1: ODD
1068 1068  * =2: EVEN
1069 1069  )))
1070 -|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10066|(% colspan="2" style="width:506px" %)(((
1071 -* Unit: ms.
1072 -* Range: 0 to 30000
1073 -)))
1074 -|(% style="width:173px" %)reveive timeout|(% style="width:122px" %)HSW10067|(% colspan="2" style="width:506px" %)(((
1075 -* Unit: ms.
1076 -* Range: 0 to 30000
1077 -)))
1078 -|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10068|(% colspan="2" style="width:506px" %)(((
1079 -* Unit: times.
1080 -* Range: 0 to 100
1081 -)))
1082 -|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10069|(% colspan="2" style="width:506px" %)(((
1083 -* Unit: s.
1084 -* Range: 0 to 300
1085 -)))
809 +|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10066|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000
810 +|(% style="width:173px" %)reveive timeout|(% style="width:122px" %)HSW10067|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000
811 +|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10068|(% colspan="2" style="width:506px" %)Unit: times. Range: 0~~100
812 +|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10069|(% colspan="2" style="width:506px" %)Unit: s. Range: 0~~300
1086 1086  |(% style="width:173px" %)HMI station number|(% style="width:122px" %)HSW10070|(% colspan="2" style="width:506px" %)
1087 1087  |(% style="width:173px" %)PLC station number|(% style="width:122px" %)HSW10071|(% colspan="2" style="width:506px" %)
1088 1088  |(% colspan="1" rowspan="11" style="width:102px" %)COM1-2|(% style="width:173px" %)Communication mode|(% style="width:122px" %)HSW10094|(% colspan="2" style="width:506px" %)(((
... ... @@ -1115,22 +1115,10 @@
1115 1115  * =1: ODD
1116 1116  * =2: EVEN
1117 1117  )))
1118 -|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10099|(% colspan="2" style="width:506px" %)(((
1119 -* Unit: ms.
1120 -* Range: 0 to 30000
1121 -)))
1122 -|(% style="width:173px" %)receive timeout|(% style="width:122px" %)HSW10100|(% colspan="2" style="width:506px" %)(((
1123 -* Unit: ms.
1124 -* Range: 0 to 30000
1125 -)))
1126 -|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10101|(% colspan="2" style="width:506px" %)(((
1127 -* Unit: times.
1128 -* Range: 0 to 100
1129 -)))
1130 -|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10102|(% colspan="2" style="width:506px" %)(((
1131 -* Unit: s.
1132 -* Range: 0 to 30
1133 -)))
845 +|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10099|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000
846 +|(% style="width:173px" %)receive timeout|(% style="width:122px" %)HSW10100|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000
847 +|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10101|(% colspan="2" style="width:506px" %)Unit: times. Range: 0~~100
848 +|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10102|(% colspan="2" style="width:506px" %)Unit: s. Range: 0~~30
1134 1134  |(% style="width:173px" %)HMI station number|(% style="width:122px" %)HSW10103|(% colspan="2" style="width:506px" %)
1135 1135  |(% style="width:173px" %)PLC station number|(% style="width:122px" %)HSW10104|(% colspan="2" style="width:506px" %)
1136 1136  |(% colspan="1" rowspan="11" style="width:102px" %)COM1-3|(% style="width:173px" %)Communication mode|(% style="width:122px" %)HSW10120|(% colspan="2" style="width:506px" %)(((
... ... @@ -1163,22 +1163,10 @@
1163 1163  * =1: ODD
1164 1164  * =2: EVEN
1165 1165  )))
1166 -|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10125|(% colspan="2" style="width:506px" %)(((
1167 -* Unit: ms.
1168 -* Range: 0 to 30000
1169 -)))
1170 -|(% style="width:173px" %)receive timeout|(% style="width:122px" %)HSW10126|(% colspan="2" style="width:506px" %)(((
1171 -* Unit: ms.
1172 -* Range: 0 to 30000
1173 -)))
1174 -|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10127|(% colspan="2" style="width:506px" %)(((
1175 -* Unit: times.
1176 -* Range: 0 to 100
1177 -)))
1178 -|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10128|(% colspan="2" style="width:506px" %)(((
1179 -* Unit: s.
1180 -* Range: 0 to 30
1181 -)))
881 +|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10125|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000
882 +|(% style="width:173px" %)receive timeout|(% style="width:122px" %)HSW10126|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000
883 +|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10127|(% colspan="2" style="width:506px" %)Unit: times. Range: 0~~100
884 +|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10128|(% colspan="2" style="width:506px" %)Unit: s. Range: 0~~30
1182 1182  |(% style="width:173px" %)HMI station number|(% style="width:122px" %)HSW10129|(% colspan="2" style="width:506px" %)
1183 1183  |(% style="width:173px" %)PLC station number|(% style="width:122px" %)HSW10130|(% colspan="2" style="width:506px" %)
1184 1184  |(% colspan="1" rowspan="11" style="width:102px" %)COM2|(% style="width:173px" %)Communication mode|(% style="width:122px" %)HSW10072|(% colspan="2" style="width:506px" %)(((
... ... @@ -1209,22 +1209,10 @@
1209 1209  * =1: ODD
1210 1210  * =2: EVEN
1211 1211  )))
1212 -|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10077|(% colspan="2" style="width:506px" %)(((
1213 -* Unit: ms.
1214 -* Range: 0 to 30000
1215 -)))
1216 -|(% style="width:173px" %)receive timeout|(% style="width:122px" %)HSW10078|(% colspan="2" style="width:506px" %)(((
1217 -* Unit: ms.
1218 -* Range: 0 to 30000
1219 -)))
1220 -|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10079|(% colspan="2" style="width:506px" %)(((
1221 -* Unit: times.
1222 -* Range: 0 to 100
1223 -)))
1224 -|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10080|(% colspan="2" style="width:506px" %)(((
1225 -* Unit: s.
1226 -* Range: 0 to 30
1227 -)))
915 +|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10077|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000
916 +|(% style="width:173px" %)receive timeout|(% style="width:122px" %)HSW10078|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000
917 +|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10079|(% colspan="2" style="width:506px" %)Unit: times. Range: 0~~100
918 +|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10080|(% colspan="2" style="width:506px" %)Unit: s. Range: 0~~30
1228 1228  |(% style="width:173px" %)HMI station number|(% style="width:122px" %)HSW10081|(% colspan="2" style="width:506px" %)
1229 1229  |(% style="width:173px" %)PLC station number|(% style="width:122px" %)HSW10082|(% colspan="2" style="width:506px" %)
1230 1230  |(% colspan="1" rowspan="11" style="width:102px" %)COM2-2|(% style="width:173px" %)Communication mode|(% style="width:122px" %)HSW10105|(% colspan="2" style="width:506px" %)(((
... ... @@ -1255,22 +1255,10 @@
1255 1255  * =1: ODD
1256 1256  * =2: EVEN
1257 1257  )))
1258 -|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10110|(% colspan="2" style="width:506px" %)(((
1259 -* Unit: ms.
1260 -* Range: 0 to 30000
1261 -)))
1262 -|(% style="width:173px" %)receive timeout|(% style="width:122px" %)HSW10111|(% colspan="2" style="width:506px" %)(((
1263 -* Unit: ms.
1264 -* Range: 0 to 30000
1265 -)))
1266 -|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10112|(% colspan="2" style="width:506px" %)(((
1267 -* Unit: times.
1268 -* Range: 0 to 100
1269 -)))
1270 -|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10113|(% colspan="2" style="width:506px" %)(((
1271 -* Unit: s.
1272 -* Range: 0 to 30
1273 -)))
949 +|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10110|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000
950 +|(% style="width:173px" %)receive timeout|(% style="width:122px" %)HSW10111|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000
951 +|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10112|(% colspan="2" style="width:506px" %)Unit: times. Range: 0~~100
952 +|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10113|(% colspan="2" style="width:506px" %)Unit: s. Range: 0~~30
1274 1274  |(% style="width:173px" %)HMI station number|(% style="width:122px" %)HSW10114|(% colspan="2" style="width:506px" %)
1275 1275  |(% style="width:173px" %)PLC station number|(% style="width:122px" %)HSW10115|(% colspan="2" style="width:506px" %)
1276 1276  |(% colspan="1" rowspan="11" style="width:102px" %)COM3|(% style="width:173px" %)Communication mode|(% style="width:122px" %)HSW10083|(% colspan="2" style="width:506px" %)(((
... ... @@ -1300,48 +1300,29 @@
1300 1300  * =1: ODD
1301 1301  * =2: EVEN
1302 1302  )))
1303 -|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10088|(% colspan="2" style="width:506px" %)(((
1304 -* Unit: ms.
1305 -* Range: 0 to 30000
1306 -)))
1307 -|(% style="width:173px" %)receive timeout|(% style="width:122px" %)HSW10089|(% colspan="2" style="width:506px" %)(((
1308 -* Unit: ms.
1309 -* Range: 0 to 30000
1310 -)))
1311 -|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10090|(% colspan="2" style="width:506px" %)(((
1312 -* Unit: times.
1313 -* Range: 0 to 100
1314 -)))
1315 -|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10091|(% colspan="2" style="width:506px" %)(((
1316 -* Unit: s.
1317 -* Range: 0 to 30
1318 -)))
982 +|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10088|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000
983 +|(% style="width:173px" %)receive timeout|(% style="width:122px" %)HSW10089|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000
984 +|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10090|(% colspan="2" style="width:506px" %)Unit: times. Range: 0~~100
985 +|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10091|(% colspan="2" style="width:506px" %)Unit: s. Range: 0~~30
1319 1319  |(% style="width:173px" %)HMI station number|(% style="width:122px" %)HSW10092|(% colspan="2" style="width:506px" %)
1320 1320  |(% style="width:173px" %)PLC station number|(% style="width:122px" %)HSW10093|(% colspan="2" style="width:506px" %)
1321 1321  |(% colspan="1" rowspan="2" style="width:102px" %)CAN port|(% style="width:173px" %)CAN1 baud rate|(% style="width:122px" %)HSW010116|(% style="width:299px" %)(((
1322 -Unit: K, the baud rate must be an integer.
1323 -
1324 -For example, when the baud rate required is 250000, just enter 250.
989 +Unit: K, the baud rate must be an integer, for example, when the baud rate required is 250000, just enter 250.
1325 1325  )))|(% colspan="1" rowspan="2" style="width:218px" %)**✎Note: **If baud rate has been modified,please wait 5 seconds,then restart the HMI to take effect.
1326 -|(% style="width:173px" %)CAN2 baud rate|(% style="width:122px" %)HSW010117|(% style="width:299px" %)(((
1327 -Unit: K, the baud rate must be an integer.
991 +|(% style="width:173px" %)CAN2 baud rate|(% style="width:122px" %)HSW010117|(% style="width:299px" %)Unit: K, the baud rate must be an integer, for example, when the baud rate required is 250000, just enter 250.
1328 1328  
1329 -For example, when the baud rate required is 250000, just enter 250.
1330 -)))
993 +== **Ethernet communication configuration** ==
1331 1331  
1332 -== Ethernet communication configuration ==
1333 -
1334 1334  (% class="table-bordered" %)
1335 -|(% style="width:40px" %)**No.**|(% style="width:295px" %)**Function**|(% style="width:220px" %)**Address**|(% style="width:336px" %)**Description**
996 +|=(% style="width: 40px;" %)**No.**|=(% style="width: 295px;" %)**Function**|=(% style="width: 220px;" %)**Address**|=(% style="width: 336px;" %)**Description**
1336 1336  |(% rowspan="7" style="width:40px" %)1|(% colspan="1" rowspan="7" style="width:295px" %)Ethernet parameter configuration for communication number 1 in list. Configure those addresses according to connected device. After configuration, wait for 5 seconds and restart the HMI.|(% style="width:220px" %)HSW11004|(% style="width:336px" %)Device IP address high word 1
1337 1337  |(% style="width:220px" %)HSW11005|(% style="width:336px" %)Device IP address high word 2
1338 1338  |(% style="width:220px" %)HSW11006|(% style="width:336px" %)Device IP address high word 3
1339 1339  |(% style="width:220px" %)HSW11007|(% style="width:336px" %)Device IP address high word 4
1340 1340  |(% style="width:220px" %)HSW11008|(% style="width:336px" %)Device Port number
1341 -|(% style="width:220px" %)HSW11009|(% style="width:336px" %)(((
1342 -~=2 TCP
1343 -
1344 -~=3 UDP
1002 +|(% style="width:220px" %)HSW11009|=(% style="width: 336px;" %)(((
1003 +* =2 TCP
1004 +* =3 UDP
1345 1345  )))
1346 1346  |(% style="width:220px" %)HSW11010|(% style="width:336px" %)Reserved
1347 1347  |(% rowspan="7" style="width:40px" %)2|(% colspan="1" rowspan="7" style="width:295px" %)Ethernet parameter configuration for communication number 2 in list. Configure those addresses according to connected device. After configuration, wait for 5 seconds and restart the HMI.|(% style="width:220px" %)HSW11011|(% style="width:336px" %)Device IP address high word 1
... ... @@ -1349,10 +1349,9 @@
1349 1349  |(% style="width:220px" %)HSW11013|(% style="width:336px" %)Device IP address high word 3
1350 1350  |(% style="width:220px" %)HSW11014|(% style="width:336px" %)Device IP address high word 4
1351 1351  |(% style="width:220px" %)HSW11015|(% style="width:336px" %)Device Port number
1352 -|(% style="width:220px" %)HSW11016|(% style="width:336px" %)(((
1353 -~=2 TCP
1354 -
1355 -~=3 UDP
1012 +|(% style="width:220px" %)HSW11016|=(% style="width: 336px;" %)(((
1013 +* =2 TCP
1014 +* =3 UDP
1356 1356  )))
1357 1357  |(% style="width:220px" %)HSW11017|(% style="width:336px" %)Reserved
1358 1358  |(% style="width:40px" %)…|(% style="width:295px" %) |(% style="width:220px" %)…|(% style="width:336px" %)…
... ... @@ -1361,11 +1361,7 @@
1361 1361  |(% style="width:220px" %)HSW11223|(% style="width:336px" %)Device IP address high word 3
1362 1362  |(% style="width:220px" %)HSW11224|(% style="width:336px" %)Device IP address high word 4
1363 1363  |(% style="width:220px" %)HSW11225|(% style="width:336px" %)Device Port number
1364 -|(% style="width:220px" %)HSW11226|(% style="width:336px" %)(((
1365 -~=2 TCP;
1366 -
1367 -~=3 UDP
1368 -)))
1023 +|(% style="width:220px" %)HSW11226|=(% style="width: 336px;" %)2 TCP; =3 UDP
1369 1369  |(% style="width:220px" %)HSW11227|(% style="width:336px" %)Reserved
1370 1370  
1371 1371  (% class="box infomessage" %)
... ... @@ -1373,7 +1373,7 @@
1373 1373  **✎Note:** The number of Ethernet connections supported by different HMI series varies.
1374 1374  )))
1375 1375  
1376 -== Communication control ==
1031 +== **Communication control** ==