Changes for page 13 HMI Internal Registers

Last modified by Jett on 2025/04/28 16:07

From version 17.1
edited by Hunter
on 2023/02/18 13:53
Change comment: There is no comment for this version
To version 15.1
edited by Theodore Xu
on 2023/01/09 15:29
Change comment: There is no comment for this version

Summary

Details

Page properties
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.Hunter
1 +XWiki.AiXia
Content
... ... @@ -485,8 +485,6 @@
485 485  * =0, Default value
486 486  * =1, Release the alarm generated before the last power-down when starting up
487 487  )))
488 -|=(% style="width: 160px;" %)HSW1200|(% colspan="1" rowspan="2" style="width:282px" %)TSAP settings for HMI in the Siemens LOGO! 8 protocol(ig series or HMI V2.0)|(% style="width:452px" %)HMI local TSAP, which corresponds to the remote TSAP of PLC
489 -|=(% style="width: 160px;" %)HSW1201|(% style="width:452px" %)HMI remote TSAP, which corresponds to the local TSAP of PLC
490 490  |=(% style="width: 160px;" %)HSW1450|(% style="width:282px" %)Enable objects level password function|(% style="width:452px" %)(((
491 491  * =0, Disable
492 492  * =1, Enable
... ... @@ -593,9 +593,6 @@
593 593  * =0: Server connection exception
594 594  * =1: Server connection is OK
595 595  )))
596 -|=(% style="width: 160px;" %)HSW1740|(% style="width:282px" %)Wi-fi signal strength|(% style="width:452px" %)(((
597 -Display the value of Wi-fi signal signal strength, ranges from 0~~100 (Signal strength is automatically obtained only once when HMI is powered on, and it will not be automatically updated. It needs to be used with the HSW1890)
598 -)))
599 599  |=(% style="width: 160px;" %)HSW1741|(% colspan="1" rowspan="12" style="width:282px" %)Related IP register in 4Gnetwork status (It is valid when HMI is connected to 4G)|(% style="width:452px" %)Local IP address high byte 1
600 600  |=(% style="width: 160px;" %)HSW1742|(% style="width:452px" %)Local IP address high byte 2
601 601  |=(% style="width: 160px;" %)HSW1743|(% style="width:452px" %)Local IP address high byte 3
... ... @@ -795,8 +795,6 @@
795 795  |=(% style="width: 160px;" %)HSW1853|(% style="width:282px" %)File format for exporting data records to USB flash drive or SD card|(% style="width:452px" %)(((
796 796  * =0: db database
797 797  * =1: CSV
798 -
799 -(Only valid for script function DbToCsvFile)
800 800  )))
801 801  |=(% style="width: 160px;" %)HSW1854|(% style="width:282px" %)High and low word conversion type|(% style="width:452px" %)(((
802 802  * =0: use the old high-low word conversion (default)
... ... @@ -823,7 +823,7 @@
823 823  * =1: priority WLAN
824 824  * =2: priority 4G
825 825  )))
826 -|=(% style="width: 160px;" %)HSW1866|(% style="width:282px" %)Delete the Lua extension module file|(% style="width:452px" %)(((
819 +|=(% style="width: 160px;" %)HSW1866|(% style="width:282px" %)Delete the LUa extension module file|(% style="width:452px" %)(((
827 827  * =0: delete;
828 828  * = Others: do not delete
829 829  )))
... ... @@ -892,15 +892,6 @@
892 892  |=(% style="width: 160px;" %)(((
893 893  HSW1879
894 894  )))|(% style="width:452px" %)Ethernet1 Local DNS2 address high byte 4
895 -|=(% style="width: 160px;" %)HSW1890|(% colspan="1" style="width:282px" %)Enable refresh current network signal|(% style="width:452px" %)(((
896 -* =1: Refresh the network signal once after triggered (This register will be automatically reset after triggered, only update the signal value once after per 15 seconds, not able to update twice in the short interval)
897 -* =Others: not refresh
898 -)))
899 -|=(% style="width: 160px;" %)HSW1891|(% colspan="1" style="width:282px" %)Enable clear cache for screen data  |(% style="width:452px" %)(((
900 -* =1, not clear screen cache when switch language
901 -* =2, trigger clear cache of all screens for once time
902 -* =3, always clear cache of all screen data
903 -)))
904 904  |=(% style="width: 160px;" %)HSW10000~~19999|(% style="width:282px" %)Power-down storage area|(% style="width:452px" %)After restart, the data remains
905 905  |=(% style="width: 160px;" %)HSW10035|(% rowspan="13" style="width:282px" %)(((
906 906  Note: Valid when Ethernet1 of HMI is plugged into the network cable.
... ... @@ -933,7 +933,7 @@
933 933  |=(% style="width: 160px;" %)HSW10051|(% style="width:452px" %)Local MAC code high word 4
934 934  |=(% style="width: 160px;" %)HSW10052|(% style="width:452px" %)Local MAC code high word 5
935 935  |=(% style="width: 160px;" %)HSW10053|(% style="width:452px" %)Local MAC code high word 6
936 -|=(% style="width: 160px;" %)HSW10118|(% colspan="1" rowspan="2" style="width:282px" %)TSAP settings for HMI in the Siemens LOGO! 8 protocol|(% style="width:452px" %)HMI local TSAP, which corresponds to the remote TSAP of PLC
920 +|=(% style="width: 160px;" %)HSW10118|(% colspan="1" rowspan="2" style="width:282px" %)TSAP settings for HMI in the Siemens logo! 8 protocol|(% style="width:452px" %)HMI local TSAP, which corresponds to the remote TSAP of PLC
937 937  |=(% style="width: 160px;" %)HSW10119|(% style="width:452px" %)HMI remote TSAP, which corresponds to the local TSAP of PLC
938 938  |=(% style="width: 160px;" %)HSW10461~~10493|(% style="width:282px" %)Remote access password|(% style="width:452px" %)8-character remote access password
939 939  |=(% style="width: 160px;" %)HSW10494~~10558|(% style="width:282px" %)Machine ID (Read only)|(% style="width:452px" %)Machine ID for remote access (read only 64-bit)