Changes for page 13 HMI Internal Registers
Last modified by Jett on 2025/04/28 16:07
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -593,9 +593,6 @@ 593 593 * =0: Server connection exception 594 594 * =1: Server connection is OK 595 595 ))) 596 -|=(% style="width: 160px;" %)HSW1740|(% style="width:282px" %)Wi-fi signal strength|(% style="width:452px" %)((( 597 -Display the value of Wi-fi signal signal strength, ranges from 0~~100 (Signal strength is automatically obtained only once when HMI is powered on, and it will not be automatically updated. It needs to be used with the HSW1890) 598 -))) 599 599 |=(% style="width: 160px;" %)HSW1741|(% colspan="1" rowspan="12" style="width:282px" %)Related IP register in 4Gnetwork status (It is valid when HMI is connected to 4G)|(% style="width:452px" %)Local IP address high byte 1 600 600 |=(% style="width: 160px;" %)HSW1742|(% style="width:452px" %)Local IP address high byte 2 601 601 |=(% style="width: 160px;" %)HSW1743|(% style="width:452px" %)Local IP address high byte 3 ... ... @@ -795,8 +795,6 @@ 795 795 |=(% style="width: 160px;" %)HSW1853|(% style="width:282px" %)File format for exporting data records to USB flash drive or SD card|(% style="width:452px" %)((( 796 796 * =0: db database 797 797 * =1: CSV 798 - 799 -(Only valid for script function DbToCsvFile) 800 800 ))) 801 801 |=(% style="width: 160px;" %)HSW1854|(% style="width:282px" %)High and low word conversion type|(% style="width:452px" %)((( 802 802 * =0: use the old high-low word conversion (default) ... ... @@ -823,7 +823,7 @@ 823 823 * =1: priority WLAN 824 824 * =2: priority 4G 825 825 ))) 826 -|=(% style="width: 160px;" %)HSW1866|(% style="width:282px" %)Delete the L ua extension module file|(% style="width:452px" %)(((821 +|=(% style="width: 160px;" %)HSW1866|(% style="width:282px" %)Delete the LUa extension module file|(% style="width:452px" %)((( 827 827 * =0: delete; 828 828 * = Others: do not delete 829 829 ))) ... ... @@ -892,15 +892,6 @@ 892 892 |=(% style="width: 160px;" %)((( 893 893 HSW1879 894 894 )))|(% style="width:452px" %)Ethernet1 Local DNS2 address high byte 4 895 -|=(% style="width: 160px;" %)HSW1890|(% colspan="1" style="width:282px" %)Enable refresh current network signal|(% style="width:452px" %)((( 896 -* =1: Refresh the network signal once after triggered (This register will be automatically reset after triggered, only update the signal value once after per 15 seconds, not able to update twice in the short interval) 897 -* =Others: not refresh 898 -))) 899 -|=(% style="width: 160px;" %)HSW1891|(% colspan="1" style="width:282px" %)Enable clear cache for screen data |(% style="width:452px" %)((( 900 -* =1, not clear screen cache when switch language 901 -* =2, trigger clear cache of all screens for once time 902 -* =3, always clear cache of all screen data 903 -))) 904 904 |=(% style="width: 160px;" %)HSW10000~~19999|(% style="width:282px" %)Power-down storage area|(% style="width:452px" %)After restart, the data remains 905 905 |=(% style="width: 160px;" %)HSW10035|(% rowspan="13" style="width:282px" %)((( 906 906 Note: Valid when Ethernet1 of HMI is plugged into the network cable.