... ... @@ -1,1 +1,1 @@
1 -12 HMI internal registers
1 +13.HMI Internal Registers
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.Hunter
1 +XWiki.Mora
Content
... ... @@ -25,6 +25,11 @@
25 25  * The address of the bit address HDX is with a decimal point while word addresses are integers.
26 26  )))
27 27  
28 += Address ranges table =
29 +
30 +(% style="text-align:center" %)
31 +[[image:6.png]]
32 +
28 28  = **Data storage area (HDW/HDX)** =
29 29  
30 30  It is used to save the temporary data of project.
... ... @@ -51,21 +51,27 @@
51 51  
52 52  It is system recipe data power-off save register. The range is from RPW000000 to RPW990450.
53 53  
59 +(% class="box infomessage" %)
60 +(((
54 54  **✎Note:**
55 55  
56 56  * RPW is power-down retention. The register of this type is able to save the data before the power-down.
57 57  * To avoid possible device failure, do not immediately power off and reboot when configuring the power-down save addre
65 +)))
58 58  
59 59  = **Single user data area (HUW/HUX)** =
60 60  
61 61  It is used for system special registers (reserved by system).
62 62  
63 -1. Access as word, and serial number range is from HUW0 to HUW199999.
64 -1. Access as bit, and serial number range is from HUX0.0 to HUX199999.15.
71 +1. Access as word, and serial number range is from HUW0 to HUW1599.
72 +1. Access as bit, and serial number range is from HUX0.0 to HUX1599.15.
65 65  
74 +(% class="box infomessage" %)
75 +(((
66 66  **✎Note:**
67 67  
68 68  * HUW/HUX is a system special register, so please check the system special register list during use. Please use the address specified in the table and do not use the address which is not mentioned in the table.
79 +)))
69 69  
70 70  (% class="table-bordered" %)
71 71  |=**Special register address**|=**Description**|=**Function**
... ... @@ -135,8 +135,8 @@
135 135  (% class="table-bordered" style="width:1024px" %)
136 136  |=(% scope="row" style="width: 160px;" %)**Address**|=(% style="width: 282px;" %)**Function**|=(% style="width: 452px;" %)**Description**
137 137  |=(% style="width: 160px;" %)HSW0|(% style="width:282px" %)Language switch|(% style="width:452px" %)Multiple language could be set in the project, HMI support maximum 8 languages. (Power-down save supported)
138 -|=(% style="width: 160px;" %)HSW1|(% style="width:282px" %)Beep frequency|(% style="width:452px" %)Frequency range: 0~~4000
139 -|=(% style="width: 160px;" %)HSW2|(% style="width:282px" %)Beep volume|(% style="width:452px" %)Volume range: 0~~80
149 +|=(% style="width: 160px;" %)HSW1|(% style="width:282px" %)Beep frequency (Only valid in HMI V1.0 System)|(% style="width:452px" %)Frequency range: 0~~4000
150 +|=(% style="width: 160px;" %)HSW2|(% style="width:282px" %)Beep volume (Only valid in HMI V1.0 System)|(% style="width:452px" %)Volume range: 0~~80
140 140  |=(% style="width: 160px;" %)HSW3|(% style="width:282px" %)Beep time|(% style="width:452px" %)Unit: ms
141 141  |=(% style="width: 160px;" %)HSW4|(% style="width:282px" %)Beep whether enable or not|(% style="width:452px" %)(((
142 142  * =0: Enable.
... ... @@ -150,7 +150,7 @@
150 150  )))
151 151  |=(% style="width: 160px;" %)HSW6~~HSW7|(% style="width:282px" %)Number of alarms|(% style="width:452px" %)The number of alarm (it also includes the records of alarm confirmed)
152 152  |=(% style="width: 160px;" %)HSW8|(% style="width:282px" %)Number of unconfirmed history alarm|(% style="width:452px" %)The number of unconfirmed history alarm
153 -|=(% style="width: 160px;" %)HSW9|(% style="width:282px" %)Time out tip|(% style="width:452px" %)(((
164 +|=(% style="width: 160px;" %)HSW9|(% style="width:282px" %)Time out prompt|(% style="width:452px" %)(((
154 154  * =0: Enable
155 155  * =1: Disable
156 156  )))
... ... @@ -175,6 +175,7 @@
175 175  * =5: Friday.
176 176  * =6: Saturday.
177 177  )))
189 +|=(% style="width: 160px;" %)HSW39|(% style="width:282px" %)Beep type(Only valid in HMI V2.0 System)|(% style="width:452px" %)Type range: 1-5, Default is 1.
178 178  |=(% style="width: 160px;" %)HSW134|(% style="width:282px" %)(((
179 179  Whether the Script is read through
180 180  
... ... @@ -450,7 +450,7 @@
450 450  Address mapping polling cycle, effective range: 40~~1000ms, default: 300ms.
451 451  
452 452  * When the set value is greater than 1000, the value is 1000.
453 -* When the set value is greater than 1000, it changes to the default value 300
465 +* When the set value is lower than 40, it changes to the default value 300
454 454  )))
455 455  |=(% style="width: 160px;" %)HSW1087|(% style="width:282px" %)Control write interval in address mapping|(% style="width:452px" %)(((
456 456  After reading data to the device for N times, Perform an address mapping write operation. N is the interval value. The effective range: 0~~5, and default is 2.
... ... @@ -904,10 +904,10 @@
904 904  |=(% style="width: 160px;" %)HSW10000~~19999|(% style="width:282px" %)Power-down storage area|(% style="width:452px" %)After restart, the data remains
905 905  |=(% style="width: 160px;" %)HSW10035|(% rowspan="13" style="width:282px" %)(((
906 906  Note: Valid when Ethernet1 of HMI is plugged into the network cable.
907 -①When the Ethernet setting is enabled in the project parameters, this register displays the set value.
908 -②. When the Ethernet setting is not enabled in the engineering parameters, the register displays the Ethernet IP automatically acquired by the HMI.
909 -③. When the HMI is not plugged into the network cable, the register will show 0 whether the engineering parameters are set or not.
910 -④.IP related registers can be read and written (only static IP mode can be written).
919 +① When the Ethernet setting is enabled in the project parameters, this register displays the set value.
920 +② When the Ethernet setting is not enabled in the engineering parameters, the register displays the Ethernet IP automatically acquired by the HMI.
921 +③ When the HMI is not plugged into the network cable, the register will show 0 whether the engineering parameters are set or not.
922 +④ IP related registers can be read and written (only static IP mode can be written).
911 911  )))|(% style="width:452px" %)Local IP address high byte 1
912 912  |=(% style="width: 160px;" %)HSW10036|(% style="width:452px" %)Local IP address high byte 2
913 913  |=(% style="width: 160px;" %)HSW10037|(% style="width:452px" %)Local IP address high byte 3
... ... @@ -1001,6 +1001,7 @@
1001 1001  * =0: LAN or the external network both OK
1002 1002  * =1: Only LAN access
1003 1003  * =2: Only external network can access
1016 +* =3: Close the functions
1004 1004  )))
1005 1005  |=(% style="width: 160px;" %)HSW11757|(% style="width:282px" %)Enable the valid date of the dynamic installment password|(% style="width:452px" %)(((
1006 1006  * =0: Disabled
6.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Mora
Size
... ... @@ -1,0 +1,1 @@
1 +20.1 KB