Changes for page 13 HMI Internal Registers

Last modified by Jett on 2025/04/28 16:07

From version 18.1
edited by Hunter
on 2023/02/18 14:03
Change comment: There is no comment for this version
To version 16.3
edited by Hunter
on 2023/02/18 11:32
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -25,21 +25,6 @@
25 25  * The address of the bit address HDX is with a decimal point while word addresses are integers.
26 26  )))
27 27  
28 -(% class="wikigeneratedid" %)
29 -= Address ranges table =
30 -
31 -|=(% scope="row" style="width: 206px;" %)Address Type\HMI Series|=(% style="width: 240px;" %)General Series|=(% style="width: 200px;" %)i Series/HMI+ models|=(% style="width: 136px;" %)ie Series|=(% style="width: 232px;" %)ig Series
32 -|=(% style="width: 206px;" %)HDW|HDW0-HDW299999|HDW0-HDW299999|HDW0-HDW299999|HDW0-HDW299999
33 -|=(% style="width: 206px;" %)HSW|HSW0-HSW14999|HSW0-HSW14999|HSW0-HSW14999|HSW0-HSW14999
34 -|=(% style="width: 206px;" %)HAW|HAW0-HAW199999|HAW0-HAW199999|HAW0-HAW199999|HAW0-HAW199999
35 -|=(% style="width: 206px;" %)HUW|HUW0-HUW1599|HUW0-HUW1599|HUW0-HUW1599|HUW0-HUW1599
36 -|=(% style="width: 206px;" %)HDX|HDX0.0-HDX299999.15|HDX0.0-HDX299999.15|HDX0.0-HDX299999.15|HDX0.0-HDX299999.15
37 -|=(% style="width: 206px;" %)HSX|HSX0.0-HSX14999.15|HSX0.0-HSX14999.15|HSX0-HSX14999.15|HSX0.0-HSX14999.15
38 -|=(% style="width: 206px;" %)HAX|HAX0.0-HAX199999.15|HAX0.0-HAX199999.15|HAX0.0-HAX199999.15|HAX0.0-HAX199999.15
39 -|=(% style="width: 206px;" %)HUX|HUX0.0-HUX1599.15|HUX0.0-HUX1599.15|HUX0.0-HUX1599.15|HUX0.0-HUX1599.15
40 -|=(% style="width: 206px;" %)RPW| |RPW000000-RPW990450|RPW000000-RPW990450|RPW000000-RPW990450
41 -|=(% style="width: 206px;" %) |(% style="width:240px" %) |(% style="width:200px" %) |(% style="width:136px" %) |(% style="width:232px" %)
42 -
43 43  = **Data storage area (HDW/HDX)** =
44 44  
45 45  It is used to save the temporary data of project.
... ... @@ -608,7 +608,7 @@
608 608  * =0: Server connection exception
609 609  * =1: Server connection is OK
610 610  )))
611 -|=(% style="width: 160px;" %)HSW1740|(% style="width:282px" %)Wi-fi signal strength|(% style="width:452px" %)(((
596 +|=(% style="width: 160px;" %)HSW1740|(% style="width:282px" %)Wi-fi signal signal strength|(% style="width:452px" %)(((
612 612  Display the value of Wi-fi signal signal strength, ranges from 0~~100 (Signal strength is automatically obtained only once when HMI is powered on, and it will not be automatically updated. It needs to be used with the HSW1890)
613 613  )))
614 614  |=(% style="width: 160px;" %)HSW1741|(% colspan="1" rowspan="12" style="width:282px" %)Related IP register in 4Gnetwork status (It is valid when HMI is connected to 4G)|(% style="width:452px" %)Local IP address high byte 1
... ... @@ -840,7 +840,7 @@
840 840  )))
841 841  |=(% style="width: 160px;" %)HSW1866|(% style="width:282px" %)Delete the Lua extension module file|(% style="width:452px" %)(((
842 842  * =0: delete;
843 -* = Others: do not delete
828 +* = Others value: do not delete
844 844  )))
845 845  |=(% style="width: 160px;" %)HSW1867|(% style="width:282px" %)Reset mode|(% style="width:452px" %)(((
846 846  Monitor address is set during reset of reset switch, whether to cancel reset,
... ... @@ -907,15 +907,6 @@
907 907  |=(% style="width: 160px;" %)(((
908 908  HSW1879
909 909  )))|(% style="width:452px" %)Ethernet1 Local DNS2 address high byte 4
910 -|=(% style="width: 160px;" %)HSW1890|(% colspan="1" style="width:282px" %)Enable refresh current network signal|(% style="width:452px" %)(((
911 -* =1: Refresh the network signal once after triggered (This register will be automatically reset after triggered, only update the signal value once after per 15 seconds, not able to update twice in the short interval)
912 -* =Others: not refresh
913 -)))
914 -|=(% style="width: 160px;" %)HSW1891|(% colspan="1" style="width:282px" %)Enable clear cache for screen data  |(% style="width:452px" %)(((
915 -* =1, not clear screen cache when switch language
916 -* =2, trigger clear cache of all screens for once time
917 -* =3, always clear cache of all screen data
918 -)))
919 919  |=(% style="width: 160px;" %)HSW10000~~19999|(% style="width:282px" %)Power-down storage area|(% style="width:452px" %)After restart, the data remains
920 920  |=(% style="width: 160px;" %)HSW10035|(% rowspan="13" style="width:282px" %)(((
921 921  Note: Valid when Ethernet1 of HMI is plugged into the network cable.