Changes for page 13 HMI Internal Registers
Last modified by Jett on 2025/04/28 16:07
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -25,20 +25,19 @@ 25 25 * The address of the bit address HDX is with a decimal point while word addresses are integers. 26 26 ))) 27 27 28 -(% class="wikigeneratedid" %) 29 29 = Address ranges table = 30 30 31 - |=(%scope="row" style="width: 206px;" %)Address Type\HMI Series|=(% style="width: 240px;" %)General Series|=(% style="width: 200px;" %)i Series/HMI+ models|=(% style="width: 136px;" %)ie Series|=(% style="width: 232px;" %)ig Series32 -|=(% style="width: 2 06px;" %)HDW|HDW0-HDW299999|HDW0-HDW299999|HDW0-HDW299999|HDW0-HDW29999933 -|=(% style="width: 2 06px;" %)HSW|HSW0-HSW14999|HSW0-HSW14999|HSW0-HSW14999|HSW0-HSW1499934 -|=(% style="width: 2 06px;" %)HAW|HAW0-HAW199999|HAW0-HAW199999|HAW0-HAW199999|HAW0-HAW19999935 -|=(% style="width: 2 06px;" %)HUW|HUW0-HUW1599|HUW0-HUW1599|HUW0-HUW1599|HUW0-HUW159936 -|=(% style="width: 2 06px;" %)HDX|HDX0.0-HDX299999.15|HDX0.0-HDX299999.15|HDX0.0-HDX299999.15|HDX0.0-HDX299999.1537 -|=(% style="width: 2 06px;" %)HSX|HSX0.0-HSX14999.15|HSX0.0-HSX14999.15|HSX0-HSX14999.15|HSX0.0-HSX14999.1538 -|=(% style="width: 2 06px;" %)HAX|HAX0.0-HAX199999.15|HAX0.0-HAX199999.15|HAX0.0-HAX199999.15|HAX0.0-HAX199999.1539 -|=(% style="width: 2 06px;" %)HUX|HUX0.0-HUX1599.15|HUX0.0-HUX1599.15|HUX0.0-HUX1599.15|HUX0.0-HUX1599.1540 -|=(% style="width: 2 06px;" %)RPW||RPW000000-RPW990450|RPW000000-RPW990450|RPW000000-RPW99045041 -|=(% style="width: 2 06px;" %)40px" %) |(% style="width:200px" %)|(% style="width:136px" %)|(% style="width:232px" %)30 +(% cellpadding="10" %) 31 +|=(% scope="row" style="width: 218px;" %)Address Type\HMI Series|=(% style="width: 228px;" %)General Series|=(% style="width: 200px;" %)i /HMI+ Series|=(% style="width: 136px;" %)ie Series|=(% style="width: 232px;" %)ig Series 32 +|=(% style="width: 218px;" %)HDW|(% style="width:228px" %)HDW0-HDW299999|HDW0-HDW299999|HDW0-HDW299999|HDW0-HDW299999 33 +|=(% style="width: 218px;" %)HSW|(% style="width:228px" %)HSW0-HSW14999|HSW0-HSW14999|HSW0-HSW14999|HSW0-HSW14999 34 +|=(% style="width: 218px;" %)HAW|(% style="width:228px" %)HAW0-HAW199999|HAW0-HAW199999|HAW0-HAW199999|HAW0-HAW199999 35 +|=(% style="width: 218px;" %)HUW|(% style="width:228px" %)HUW0-HUW1599|HUW0-HUW1599|HUW0-HUW1599|HUW0-HUW1599 36 +|=(% style="width: 218px;" %)HDX|(% style="width:228px" %)HDX0.0-HDX299999.15|HDX0.0-HDX299999.15|HDX0.0-HDX299999.15|HDX0.0-HDX299999.15 37 +|=(% style="width: 218px;" %)HSX|(% style="width:228px" %)HSX0.0-HSX14999.15|HSX0.0-HSX14999.15|HSX0-HSX14999.15|HSX0.0-HSX14999.15 38 +|=(% style="width: 218px;" %)HAX|(% style="width:228px" %)HAX0.0-HAX199999.15|HAX0.0-HAX199999.15|HAX0.0-HAX199999.15|HAX0.0-HAX199999.15 39 +|=(% style="width: 218px;" %)HUX|(% style="width:228px" %)HUX0.0-HUX1599.15|HUX0.0-HUX1599.15|HUX0.0-HUX1599.15|HUX0.0-HUX1599.15 40 +|=(% style="width: 218px;" %)RPW|(% style="width:228px" %) |RPW000000-RPW990450|RPW000000-RPW990450|RPW000000-RPW990450 42 42 43 43 = **Data storage area (HDW/HDX)** = 44 44 ... ... @@ -75,8 +75,8 @@ 75 75 76 76 It is used for system special registers (reserved by system). 77 77 78 -1. Access as word, and serial number range is from HUW0 to HUW199 999.79 -1. Access as bit, and serial number range is from HUX0.0 to HUX199 999.15.77 +1. Access as word, and serial number range is from HUW0 to HUW1599. 78 +1. Access as bit, and serial number range is from HUX0.0 to HUX1599.15. 80 80 81 81 **✎Note:** 82 82 ... ... @@ -919,10 +919,10 @@ 919 919 |=(% style="width: 160px;" %)HSW10000~~19999|(% style="width:282px" %)Power-down storage area|(% style="width:452px" %)After restart, the data remains 920 920 |=(% style="width: 160px;" %)HSW10035|(% rowspan="13" style="width:282px" %)((( 921 921 Note: Valid when Ethernet1 of HMI is plugged into the network cable. 922 -① 、When the Ethernet setting is enabled in the project parameters, this register displays the set value.923 -② .When the Ethernet setting is not enabled in the engineering parameters, the register displays the Ethernet IP automatically acquired by the HMI.924 -③ .When the HMI is not plugged into the network cable, the register will show 0 whether the engineering parameters are set or not.925 -④ .IP related registers can be read and written (only static IP mode can be written).921 +① When the Ethernet setting is enabled in the project parameters, this register displays the set value. 922 +② When the Ethernet setting is not enabled in the engineering parameters, the register displays the Ethernet IP automatically acquired by the HMI. 923 +③ When the HMI is not plugged into the network cable, the register will show 0 whether the engineering parameters are set or not. 924 +④ IP related registers can be read and written (only static IP mode can be written). 926 926 )))|(% style="width:452px" %)Local IP address high byte 1 927 927 |=(% style="width: 160px;" %)HSW10036|(% style="width:452px" %)Local IP address high byte 2 928 928 |=(% style="width: 160px;" %)HSW10037|(% style="width:452px" %)Local IP address high byte 3