Changes for page 13 HMI Internal Registers

Last modified by Jett on 2025/04/28 16:07

From version 18.1
edited by Hunter
on 2023/02/18 14:03
Change comment: There is no comment for this version
To version 25.1
edited by Hunter
on 2023/03/01 11:16
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -25,20 +25,19 @@
25 25  * The address of the bit address HDX is with a decimal point while word addresses are integers.
26 26  )))
27 27  
28 -(% class="wikigeneratedid" %)
29 29  = Address ranges table =
30 30  
31 -|=(% scope="row" style="width: 206px;" %)Address Type\HMI Series|=(% style="width: 240px;" %)General Series|=(% style="width: 200px;" %)i Series/HMI+ models|=(% style="width: 136px;" %)ie Series|=(% style="width: 232px;" %)ig Series
32 -|=(% style="width: 206px;" %)HDW|HDW0-HDW299999|HDW0-HDW299999|HDW0-HDW299999|HDW0-HDW299999
33 -|=(% style="width: 206px;" %)HSW|HSW0-HSW14999|HSW0-HSW14999|HSW0-HSW14999|HSW0-HSW14999
34 -|=(% style="width: 206px;" %)HAW|HAW0-HAW199999|HAW0-HAW199999|HAW0-HAW199999|HAW0-HAW199999
35 -|=(% style="width: 206px;" %)HUW|HUW0-HUW1599|HUW0-HUW1599|HUW0-HUW1599|HUW0-HUW1599
36 -|=(% style="width: 206px;" %)HDX|HDX0.0-HDX299999.15|HDX0.0-HDX299999.15|HDX0.0-HDX299999.15|HDX0.0-HDX299999.15
37 -|=(% style="width: 206px;" %)HSX|HSX0.0-HSX14999.15|HSX0.0-HSX14999.15|HSX0-HSX14999.15|HSX0.0-HSX14999.15
38 -|=(% style="width: 206px;" %)HAX|HAX0.0-HAX199999.15|HAX0.0-HAX199999.15|HAX0.0-HAX199999.15|HAX0.0-HAX199999.15
39 -|=(% style="width: 206px;" %)HUX|HUX0.0-HUX1599.15|HUX0.0-HUX1599.15|HUX0.0-HUX1599.15|HUX0.0-HUX1599.15
40 -|=(% style="width: 206px;" %)RPW| |RPW000000-RPW990450|RPW000000-RPW990450|RPW000000-RPW990450
41 -|=(% style="width: 206px;" %) |(% style="width:240px" %) |(% style="width:200px" %) |(% style="width:136px" %) |(% style="width:232px" %)
30 +(% cellpadding="10" %)
31 +|=(% scope="row" style="width: 218px;" %)Address Type\HMI Series|=(% style="width: 228px;" %)General Series|=(% style="width: 200px;" %)i /HMI+ Series|=(% style="width: 136px;" %)ie Series|=(% style="width: 232px;" %)ig Series
32 +|=(% style="width: 218px;" %)HDW|(% style="width:228px" %)HDW0-HDW299999|HDW0-HDW299999|HDW0-HDW299999|HDW0-HDW299999
33 +|=(% style="width: 218px;" %)HSW|(% style="width:228px" %)HSW0-HSW14999|HSW0-HSW14999|HSW0-HSW14999|HSW0-HSW14999
34 +|=(% style="width: 218px;" %)HAW|(% style="width:228px" %)HAW0-HAW199999|HAW0-HAW199999|HAW0-HAW199999|HAW0-HAW199999
35 +|=(% style="width: 218px;" %)HUW|(% style="width:228px" %)HUW0-HUW1599|HUW0-HUW1599|HUW0-HUW1599|HUW0-HUW1599
36 +|=(% style="width: 218px;" %)HDX|(% style="width:228px" %)HDX0.0-HDX299999.15|HDX0.0-HDX299999.15|HDX0.0-HDX299999.15|HDX0.0-HDX299999.15
37 +|=(% style="width: 218px;" %)HSX|(% style="width:228px" %)HSX0.0-HSX14999.15|HSX0.0-HSX14999.15|HSX0-HSX14999.15|HSX0.0-HSX14999.15
38 +|=(% style="width: 218px;" %)HAX|(% style="width:228px" %)HAX0.0-HAX199999.15|HAX0.0-HAX199999.15|HAX0.0-HAX199999.15|HAX0.0-HAX199999.15
39 +|=(% style="width: 218px;" %)HUX|(% style="width:228px" %)HUX0.0-HUX1599.15|HUX0.0-HUX1599.15|HUX0.0-HUX1599.15|HUX0.0-HUX1599.15
40 +|=(% style="width: 218px;" %)RPW|(% style="width:228px" %) |RPW000000-RPW990450|RPW000000-RPW990450|RPW000000-RPW990450
42 42  
43 43  = **Data storage area (HDW/HDX)** =
44 44  
... ... @@ -75,8 +75,8 @@
75 75  
76 76  It is used for system special registers (reserved by system).
77 77  
78 -1. Access as word, and serial number range is from HUW0 to HUW199999.
79 -1. Access as bit, and serial number range is from HUX0.0 to HUX199999.15.
77 +1. Access as word, and serial number range is from HUW0 to HUW1599.
78 +1. Access as bit, and serial number range is from HUX0.0 to HUX1599.15.
80 80  
81 81  **✎Note:**
82 82  
... ... @@ -919,10 +919,10 @@
919 919  |=(% style="width: 160px;" %)HSW10000~~19999|(% style="width:282px" %)Power-down storage area|(% style="width:452px" %)After restart, the data remains
920 920  |=(% style="width: 160px;" %)HSW10035|(% rowspan="13" style="width:282px" %)(((
921 921  Note: Valid when Ethernet1 of HMI is plugged into the network cable.
922 -①When the Ethernet setting is enabled in the project parameters, this register displays the set value.
923 -②. When the Ethernet setting is not enabled in the engineering parameters, the register displays the Ethernet IP automatically acquired by the HMI.
924 -③. When the HMI is not plugged into the network cable, the register will show 0 whether the engineering parameters are set or not.
925 -④.IP related registers can be read and written (only static IP mode can be written).
921 +① When the Ethernet setting is enabled in the project parameters, this register displays the set value.
922 +② When the Ethernet setting is not enabled in the engineering parameters, the register displays the Ethernet IP automatically acquired by the HMI.
923 +③ When the HMI is not plugged into the network cable, the register will show 0 whether the engineering parameters are set or not.
924 +④ IP related registers can be read and written (only static IP mode can be written).
926 926  )))|(% style="width:452px" %)Local IP address high byte 1
927 927  |=(% style="width: 160px;" %)HSW10036|(% style="width:452px" %)Local IP address high byte 2
928 928  |=(% style="width: 160px;" %)HSW10037|(% style="width:452px" %)Local IP address high byte 3