Changes for page 13 HMI Internal Registers
Last modified by Jett on 2025/04/28 16:07
Summary
-
Page properties (3 modified, 0 added, 0 removed)
-
Attachments (0 modified, 1 added, 0 removed)
Details
- Page properties
-
- Title
-
... ... @@ -1,1 +1,1 @@ 1 -1 2HMIinternalregisters1 +13.HMI Internal Registers - Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Hunter1 +XWiki.Mora - Content
-
... ... @@ -25,20 +25,10 @@ 25 25 * The address of the bit address HDX is with a decimal point while word addresses are integers. 26 26 ))) 27 27 28 -(% class="wikigeneratedid" %) 29 29 = Address ranges table = 30 30 31 -|=(% scope="row" style="width: 206px;" %)Address Type\HMI Series|=(% style="width: 240px;" %)General Series|=(% style="width: 200px;" %)i Series/HMI+ models|=(% style="width: 136px;" %)ie Series|=(% style="width: 232px;" %)ig Series 32 -|=(% style="width: 206px;" %)HDW|HDW0-HDW299999|HDW0-HDW299999|HDW0-HDW299999|HDW0-HDW299999 33 -|=(% style="width: 206px;" %)HSW|HSW0-HSW14999|HSW0-HSW14999|HSW0-HSW14999|HSW0-HSW14999 34 -|=(% style="width: 206px;" %)HAW|HAW0-HAW199999|HAW0-HAW199999|HAW0-HAW199999|HAW0-HAW199999 35 -|=(% style="width: 206px;" %)HUW|HUW0-HUW1599|HUW0-HUW1599|HUW0-HUW1599|HUW0-HUW1599 36 -|=(% style="width: 206px;" %)HDX|HDX0.0-HDX299999.15|HDX0.0-HDX299999.15|HDX0.0-HDX299999.15|HDX0.0-HDX299999.15 37 -|=(% style="width: 206px;" %)HSX|HSX0.0-HSX14999.15|HSX0.0-HSX14999.15|HSX0-HSX14999.15|HSX0.0-HSX14999.15 38 -|=(% style="width: 206px;" %)HAX|HAX0.0-HAX199999.15|HAX0.0-HAX199999.15|HAX0.0-HAX199999.15|HAX0.0-HAX199999.15 39 -|=(% style="width: 206px;" %)HUX|HUX0.0-HUX1599.15|HUX0.0-HUX1599.15|HUX0.0-HUX1599.15|HUX0.0-HUX1599.15 40 -|=(% style="width: 206px;" %)RPW| |RPW000000-RPW990450|RPW000000-RPW990450|RPW000000-RPW990450 41 -|=(% style="width: 206px;" %) |(% style="width:240px" %) |(% style="width:200px" %) |(% style="width:136px" %) |(% style="width:232px" %) 30 +(% style="text-align:center" %) 31 +[[image:6.png]] 42 42 43 43 = **Data storage area (HDW/HDX)** = 44 44 ... ... @@ -75,8 +75,8 @@ 75 75 76 76 It is used for system special registers (reserved by system). 77 77 78 -1. Access as word, and serial number range is from HUW0 to HUW199 999.79 -1. Access as bit, and serial number range is from HUX0.0 to HUX199 999.15.68 +1. Access as word, and serial number range is from HUW0 to HUW1599. 69 +1. Access as bit, and serial number range is from HUX0.0 to HUX1599.15. 80 80 81 81 **✎Note:** 82 82 ... ... @@ -150,8 +150,8 @@ 150 150 (% class="table-bordered" style="width:1024px" %) 151 151 |=(% scope="row" style="width: 160px;" %)**Address**|=(% style="width: 282px;" %)**Function**|=(% style="width: 452px;" %)**Description** 152 152 |=(% style="width: 160px;" %)HSW0|(% style="width:282px" %)Language switch|(% style="width:452px" %)Multiple language could be set in the project, HMI support maximum 8 languages. (Power-down save supported) 153 -|=(% style="width: 160px;" %)HSW1|(% style="width:282px" %)Beep frequency|(% style="width:452px" %)Frequency range: 0~~4000 154 -|=(% style="width: 160px;" %)HSW2|(% style="width:282px" %)Beep volume|(% style="width:452px" %)Volume range: 0~~80 143 +|=(% style="width: 160px;" %)HSW1|(% style="width:282px" %)Beep frequency (Only valid in HMI V1.0 System)|(% style="width:452px" %)Frequency range: 0~~4000 144 +|=(% style="width: 160px;" %)HSW2|(% style="width:282px" %)Beep volume (Only valid in HMI V1.0 System)|(% style="width:452px" %)Volume range: 0~~80 155 155 |=(% style="width: 160px;" %)HSW3|(% style="width:282px" %)Beep time|(% style="width:452px" %)Unit: ms 156 156 |=(% style="width: 160px;" %)HSW4|(% style="width:282px" %)Beep whether enable or not|(% style="width:452px" %)((( 157 157 * =0: Enable. ... ... @@ -165,7 +165,7 @@ 165 165 ))) 166 166 |=(% style="width: 160px;" %)HSW6~~HSW7|(% style="width:282px" %)Number of alarms|(% style="width:452px" %)The number of alarm (it also includes the records of alarm confirmed) 167 167 |=(% style="width: 160px;" %)HSW8|(% style="width:282px" %)Number of unconfirmed history alarm|(% style="width:452px" %)The number of unconfirmed history alarm 168 -|=(% style="width: 160px;" %)HSW9|(% style="width:282px" %)Time out tip|(% style="width:452px" %)(((158 +|=(% style="width: 160px;" %)HSW9|(% style="width:282px" %)Time out prompt|(% style="width:452px" %)((( 169 169 * =0: Enable 170 170 * =1: Disable 171 171 ))) ... ... @@ -190,6 +190,7 @@ 190 190 * =5: Friday. 191 191 * =6: Saturday. 192 192 ))) 183 +|=(% style="width: 160px;" %)HSW39|(% style="width:282px" %)Beep type(Only valid in HMI V2.0 System)|(% style="width:452px" %)Type range: 1-5, Default is 1. 193 193 |=(% style="width: 160px;" %)HSW134|(% style="width:282px" %)((( 194 194 Whether the Script is read through 195 195 ... ... @@ -465,7 +465,7 @@ 465 465 Address mapping polling cycle, effective range: 40~~1000ms, default: 300ms. 466 466 467 467 * When the set value is greater than 1000, the value is 1000. 468 -* When the set value is greater than1000, it changes to the default value 300459 +* When the set value is lower than 40, it changes to the default value 300 469 469 ))) 470 470 |=(% style="width: 160px;" %)HSW1087|(% style="width:282px" %)Control write interval in address mapping|(% style="width:452px" %)((( 471 471 After reading data to the device for N times, Perform an address mapping write operation. N is the interval value. The effective range: 0~~5, and default is 2. ... ... @@ -919,10 +919,10 @@ 919 919 |=(% style="width: 160px;" %)HSW10000~~19999|(% style="width:282px" %)Power-down storage area|(% style="width:452px" %)After restart, the data remains 920 920 |=(% style="width: 160px;" %)HSW10035|(% rowspan="13" style="width:282px" %)((( 921 921 Note: Valid when Ethernet1 of HMI is plugged into the network cable. 922 -① 、When the Ethernet setting is enabled in the project parameters, this register displays the set value.923 -② .When the Ethernet setting is not enabled in the engineering parameters, the register displays the Ethernet IP automatically acquired by the HMI.924 -③ .When the HMI is not plugged into the network cable, the register will show 0 whether the engineering parameters are set or not.925 -④ .IP related registers can be read and written (only static IP mode can be written).913 +① When the Ethernet setting is enabled in the project parameters, this register displays the set value. 914 +② When the Ethernet setting is not enabled in the engineering parameters, the register displays the Ethernet IP automatically acquired by the HMI. 915 +③ When the HMI is not plugged into the network cable, the register will show 0 whether the engineering parameters are set or not. 916 +④ IP related registers can be read and written (only static IP mode can be written). 926 926 )))|(% style="width:452px" %)Local IP address high byte 1 927 927 |=(% style="width: 160px;" %)HSW10036|(% style="width:452px" %)Local IP address high byte 2 928 928 |=(% style="width: 160px;" %)HSW10037|(% style="width:452px" %)Local IP address high byte 3
- 6.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Mora - Size
-
... ... @@ -1,0 +1,1 @@ 1 +20.1 KB - Content