Changes for page 13 HMI Internal Registers
Last modified by Jett on 2025/04/28 16:07
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Hunter1 +XWiki.Stone - Content
-
... ... @@ -4,11 +4,11 @@ 4 4 5 5 *HSW, HDW, HUW, HAW are word address, HSX, HDX, HUX, HAX are bit address. 6 6 7 - ***System data area (HSW): **A special register defined by the system.8 - ***Data storage area (HDW/HDX): **Users store user data.9 - ***System data area (HUW): **A special register defined by the system.10 - ***System Data (HAW)**: System register used for power-off save.11 - ***Recipe index area (RPW): **System register used for recipe index.7 +1. **System data area (HSW): **A special register defined by the system. 8 +1. **Data storage area (HDW/HDX): **Users store user data. 9 +1. **System data area (HUW): **A special register defined by the system. 10 +1. **System Data (HAW)**: System register used for power-off save. 11 +1. **Recipe index area (RPW): **System register used for recipe index. 12 12 13 13 HMI internal registers are divided into bit address and word address, which can be accessed in two ways (take HDW as an example). 14 14 ... ... @@ -25,21 +25,6 @@ 25 25 * The address of the bit address HDX is with a decimal point while word addresses are integers. 26 26 ))) 27 27 28 -(% class="wikigeneratedid" %) 29 -= Address ranges table = 30 - 31 -|=(% scope="row" style="width: 206px;" %)Address Type\HMI Series|=(% style="width: 240px;" %)General Series|=(% style="width: 200px;" %)i Series/HMI+ models|=(% style="width: 136px;" %)ie Series|=(% style="width: 232px;" %)ig Series 32 -|=(% style="width: 206px;" %)HDW|HDW0-HDW299999|HDW0-HDW299999|HDW0-HDW299999|HDW0-HDW299999 33 -|=(% style="width: 206px;" %)HSW|HSW0-HSW14999|HSW0-HSW14999|HSW0-HSW14999|HSW0-HSW14999 34 -|=(% style="width: 206px;" %)HAW|HAW0-HAW199999|HAW0-HAW199999|HAW0-HAW199999|HAW0-HAW199999 35 -|=(% style="width: 206px;" %)HUW|HUW0-HUW1599|HUW0-HUW1599|HUW0-HUW1599|HUW0-HUW1599 36 -|=(% style="width: 206px;" %)HDX|HDX0.0-HDX299999.15|HDX0.0-HDX299999.15|HDX0.0-HDX299999.15|HDX0.0-HDX299999.15 37 -|=(% style="width: 206px;" %)HSX|HSX0.0-HSX14999.15|HSX0.0-HSX14999.15|HSX0-HSX14999.15|HSX0.0-HSX14999.15 38 -|=(% style="width: 206px;" %)HAX|HAX0.0-HAX199999.15|HAX0.0-HAX199999.15|HAX0.0-HAX199999.15|HAX0.0-HAX199999.15 39 -|=(% style="width: 206px;" %)HUX|HUX0.0-HUX1599.15|HUX0.0-HUX1599.15|HUX0.0-HUX1599.15|HUX0.0-HUX1599.15 40 -|=(% style="width: 206px;" %)RPW| |RPW000000-RPW990450|RPW000000-RPW990450|RPW000000-RPW990450 41 -|=(% style="width: 206px;" %) |(% style="width:240px" %) |(% style="width:200px" %) |(% style="width:136px" %) |(% style="width:232px" %) 42 - 43 43 = **Data storage area (HDW/HDX)** = 44 44 45 45 It is used to save the temporary data of project. ... ... @@ -256,8 +256,8 @@ 256 256 * =2: HSX521.1=1, delete all trend graph. 257 257 * =4: HSX521.2=1, delete all alarms. 258 258 * =16: HSX521.4=1, delete history XY plot. 259 -* =32: HSX521.5=1, delete data records in SD card or USBflash disk;(Please make a setting which is saved toUSBflash disk or SD card in project setting).260 -* =64: HSX521.6=1, delete alarms records in SD card or USBflash disk; (Please make a setting which is saved toUSBflash disk or SD card in project setting).244 +* =32: HSX521.5=1, delete data records in SD card or flash dish;(Please make a setting which is saved to flash disk or SD card in project setting). 245 +* =64: HSX521.6=1, delete alarms records in SD card or flash dish; (Please make a setting which is saved to flash disk or SD card in project setting). 261 261 ))) 262 262 |=(% style="width: 160px;" %)HSW522|(% style="width:282px" %)Copy and paste the alarm/data files in flash to the USB flash disk|(% style="width:452px" %)((( 263 263 * =0: No operation ... ... @@ -500,8 +500,6 @@ 500 500 * =0, Default value 501 501 * =1, Release the alarm generated before the last power-down when starting up 502 502 ))) 503 -|=(% style="width: 160px;" %)HSW1200|(% colspan="1" rowspan="2" style="width:282px" %)TSAP settings for HMI in the Siemens LOGO! 8 protocol(ig series or HMI V2.0)|(% style="width:452px" %)HMI local TSAP, which corresponds to the remote TSAP of PLC 504 -|=(% style="width: 160px;" %)HSW1201|(% style="width:452px" %)HMI remote TSAP, which corresponds to the local TSAP of PLC 505 505 |=(% style="width: 160px;" %)HSW1450|(% style="width:282px" %)Enable objects level password function|(% style="width:452px" %)((( 506 506 * =0, Disable 507 507 * =1, Enable ... ... @@ -608,9 +608,6 @@ 608 608 * =0: Server connection exception 609 609 * =1: Server connection is OK 610 610 ))) 611 -|=(% style="width: 160px;" %)HSW1740|(% style="width:282px" %)Wi-fi signal strength|(% style="width:452px" %)((( 612 -Display the value of Wi-fi signal signal strength, ranges from 0~~100 (Signal strength is automatically obtained only once when HMI is powered on, and it will not be automatically updated. It needs to be used with the HSW1890) 613 -))) 614 614 |=(% style="width: 160px;" %)HSW1741|(% colspan="1" rowspan="12" style="width:282px" %)Related IP register in 4Gnetwork status (It is valid when HMI is connected to 4G)|(% style="width:452px" %)Local IP address high byte 1 615 615 |=(% style="width: 160px;" %)HSW1742|(% style="width:452px" %)Local IP address high byte 2 616 616 |=(% style="width: 160px;" %)HSW1743|(% style="width:452px" %)Local IP address high byte 3 ... ... @@ -638,180 +638,10 @@ 638 638 * =1: Server connection is OK 639 639 ))) 640 640 |=(% style="width: 160px;" %)HSW1761|(% style="width:282px" %)Display 4G network signal strength|(% style="width:452px" %)Signal strength: 0~~31. The greater the value ,the signal is stronger 641 -|=(% style="width: 160px;" %)((( 642 -HSW1762 643 -)))|(% colspan="1" rowspan="13" style="width:282px" %)((( 644 -Note: Valid when Ethernet2 of HMI is plugged into the network cable. 645 -①、When the Ethernet setting is enabled in the project parameters, this register displays the set value. 646 -②. When the Ethernet setting is not enabled in the engineering parameters, the register displays the Ethernet IP automatically acquired by the HMI. 647 -③. When the HMI is not plugged into the network cable, the register will show 0 whether the engineering parameters are set or not. 648 -④.IP related registers can be read and written (only static IP mode can be written). 649 -)))|(% style="width:452px" %)((( 650 -Ethernet2 Local IP address high byte 1 651 -))) 652 -|=(% style="width: 160px;" %)((( 653 -HSW1763 654 -)))|(% style="width:452px" %)((( 655 -Ethernet2 Local IP address high byte 2 656 -))) 657 -|=(% style="width: 160px;" %)((( 658 -HSW1764 659 -)))|(% style="width:452px" %)((( 660 -Ethernet2 Local IP address high byte 3 661 -))) 662 -|=(% style="width: 160px;" %)((( 663 -HSW1765 664 -)))|(% style="width:452px" %)((( 665 -Ethernet2 Local IP address high byte 4 666 -))) 667 -|=(% style="width: 160px;" %)((( 668 -HSW1766 669 -)))|(% style="width:452px" %)((( 670 -Ethernet2 Local mask IP address high byte 1 671 -))) 672 -|=(% style="width: 160px;" %)((( 673 -HSW1767 674 -)))|(% style="width:452px" %)((( 675 -Ethernet2 Local mask IP address high byte 2 676 -))) 677 -|=(% style="width: 160px;" %)((( 678 -HSW1768 679 -)))|(% style="width:452px" %)Ethernet2 Local mask IP address high byte 3 680 -|=(% style="width: 160px;" %)HSW1769|(% style="width:452px" %)Ethernet2 Local mask IP address high byte 4 681 -|=(% style="width: 160px;" %)((( 682 -HSW1770 683 -)))|(% style="width:452px" %)((( 684 -Ethernet2 Local gateway IP address high byte 1 685 -))) 686 -|=(% style="width: 160px;" %)((( 687 -HSW1771 688 -)))|(% style="width:452px" %)((( 689 -Ethernet2 Local gateway IP address high byte 2 690 -))) 691 -|=(% style="width: 160px;" %)((( 692 -HSW1772 693 -)))|(% style="width:452px" %)((( 694 -Ethernet2 Local gateway IP address high byte 3 695 -))) 696 -|=(% style="width: 160px;" %)((( 697 -HSW1773 698 -)))|(% style="width:452px" %)((( 699 -Ethernet2 Local gateway IP address high byte 4 700 -))) 701 -|=(% style="width: 160px;" %)((( 702 -HSW1774 703 -)))|(% style="width:452px" %)((( 704 -Ethernet2 Local Port Address 705 -))) 706 -|=(% style="width: 160px;" %)((( 707 -HSW1775 708 -)))|(% colspan="1" rowspan="6" style="width:282px" %)((( 709 -①Display the MAC code of Ethernet2 NIC 710 - 711 -(hexadecimal display) 712 - 713 -②Read-only mode, not modifiable 714 -)))|(% style="width:452px" %)((( 715 -Ethernet2 Local MAC code high byte 1 716 -))) 717 -|=(% style="width: 160px;" %)((( 718 -HSW1776 719 -)))|(% style="width:452px" %)((( 720 -Ethernet2 Local MAC code high byte 2 721 -))) 722 -|=(% style="width: 160px;" %)((( 723 -HSW1777 724 -)))|(% style="width:452px" %)((( 725 -Ethernet2 Local MAC code high byte 3 726 -))) 727 -|=(% style="width: 160px;" %)((( 728 -HSW1778 729 -)))|(% style="width:452px" %)((( 730 -Ethernet2 Local MAC code high byte 4 731 -))) 732 -|=(% style="width: 160px;" %)((( 733 -HSW1779 734 -)))|(% style="width:452px" %)((( 735 -Ethernet2 Local MAC code high byte 5 736 -))) 737 -|=(% style="width: 160px;" %)((( 738 -HSW1780 739 -)))|(% style="width:452px" %)((( 740 -Ethernet2 Local MAC code high byte 6 741 -))) 742 -|=(% style="width: 160px;" %)((( 743 -HSW1781 744 -)))|(% colspan="1" rowspan="8" style="width:282px" %)((( 745 -①Display and modify DNS1 and DNS2 of Ethernet2 746 - 747 -②Related registers can be read and written mode (only static IP mode can be written) 748 -)))|(% style="width:452px" %)((( 749 -Ethernet2 Local DNS1 address high byte 1 750 -))) 751 -|=(% style="width: 160px;" %)((( 752 -HSW1782 753 -)))|(% style="width:452px" %)((( 754 -Ethernet2 Local DNS1 address high byte 2 755 -))) 756 -|=(% style="width: 160px;" %)((( 757 -HSW1783 758 -)))|(% style="width:452px" %)((( 759 -Ethernet2 Local DNS1 address high byte 3 760 -))) 761 -|=(% style="width: 160px;" %)((( 762 -HSW1784 763 -)))|(% style="width:452px" %)((( 764 -Ethernet2 Local DNS1 address high byte 4 765 -))) 766 -|=(% style="width: 160px;" %)((( 767 -HSW1785 768 -)))|(% style="width:452px" %)((( 769 -Ethernet2 Local DNS2 address high byte 1 770 -))) 771 -|=(% style="width: 160px;" %)((( 772 -HSW1786 773 -)))|(% style="width:452px" %)((( 774 -Ethernet2 Local DNS2 address high byte 2 775 -))) 776 -|=(% style="width: 160px;" %)((( 777 -HSW1787 778 -)))|(% style="width:452px" %)((( 779 -Ethernet2 Local DNS2 address high byte 3 780 -))) 781 -|=(% style="width: 160px;" %)((( 782 -HSW1788 783 -)))|(% style="width:452px" %)((( 784 -Ethernet2 Local DNS2 address high byte 4 785 -))) 786 -|=(% style="width: 160px;" %)((( 787 -HSW1789 788 -)))|(% colspan="1" style="width:282px" %)((( 789 -Display or set the dynamic or static IP mode of Ethernet2 790 -)))|(% style="width:452px" %)((( 791 -HSX1789.0 = 0, Static IP mode 792 - 793 -HSX1789.0 = 1, dynamic IP mode 794 -))) 795 -|=(% style="width: 160px;" %)((( 796 -HSW1790 797 -)))|(% colspan="1" style="width:282px" %)((( 798 -Confirm Ethernet2 IP, subnet mask, gateway, DNS1, DNS2, and dynamic static IP settings 799 -)))|(% style="width:452px" %)((( 800 -~= 1, confirm the setting (i.e., after modifying IP-related information, set this address to 1, representing confirmation of the modification, after which it will be reset to 0) 801 -))) 802 -|=(% style="width: 160px;" %)((( 803 -HSW1791 804 -)))|(% colspan="1" style="width:282px" %)((( 805 -Network status of the Ethernet2 connection server 806 -)))|(% style="width:452px" %)((( 807 -~= 0, connection to the server is abnormal = 1, connection to the server is normal 808 -))) 809 809 |=(% style="width: 160px;" %)HSW1852|(% style="width:282px" %)Control the interval in two consecutive clicks|(% style="width:452px" %)Limit range: 1~~500ms. The default is 100 ms. 810 810 |=(% style="width: 160px;" %)HSW1853|(% style="width:282px" %)File format for exporting data records to USB flash drive or SD card|(% style="width:452px" %)((( 811 811 * =0: db database 812 812 * =1: CSV 813 - 814 -(Only valid for script function DbToCsvFile) 815 815 ))) 816 816 |=(% style="width: 160px;" %)HSW1854|(% style="width:282px" %)High and low word conversion type|(% style="width:452px" %)((( 817 817 * =0: use the old high-low word conversion (default) ... ... @@ -833,96 +833,30 @@ 833 833 * =1: download firmware 834 834 * =2: enter the background 835 835 ))) 836 -|=(% style="width: 160px;" %)HSW1865|(% style="width:282px" %)Priority connection to the cloud|(% style="width:452px" %)((( 837 -* =0: priority Ethernet 838 -* =1: priority WLAN 839 -* =2: priority 4G 646 +|=(% style="width: 160px;" %)HSW1866|(% style="width:282px" %)Delete the LUa extension module file|(% style="width:452px" %)((( 647 +* =1, delete; 648 +* = Others, do not delete 840 840 ))) 841 -|=(% style="width: 160px;" %)HSW1866|(% style="width:282px" %)Delete the Lua extension module file|(% style="width:452px" %)((( 842 -* =0: delete; 843 -* = Others: do not delete 844 -))) 845 845 |=(% style="width: 160px;" %)HSW1867|(% style="width:282px" %)Reset mode|(% style="width:452px" %)((( 846 846 Monitor address is set during reset of reset switch, whether to cancel reset, 847 847 848 -* = 0 :yes (default);849 -* = 1 :no653 +* = 0, yes (default); 654 +* = 1, no 850 850 ))) 851 851 |=(% style="width: 160px;" %)HSW1868|(% style="width:282px" %)Double-click or long press the record type table mode|(% style="width:452px" %)((( 852 852 Controls whether the button pops up when double-clicking or long pressing on record type table object 853 853 854 -* = 0 :yes (default);855 -* = 1 :no659 +* = 0, yes (default); 660 +* = 1, no 856 856 ))) 857 -|=(% style="width: 160px;" %)((( 858 -HSW1869 859 -)))|(% style="width:282px" %)((( 860 -Dynamic screensaver countdown 861 -)))|(% style="width:452px" %)((( 862 -Countdown to enter dynamic screensaver effect, unit (S) 863 -))) 864 -|=(% style="width: 160px;" %)((( 865 -HSW1870 866 -)))|(% style="width:282px" %)((( 867 -Display or set the dynamic or static IP mode of Ethernet1 868 -)))|(% style="width:452px" %)((( 869 -HSX1870.0 = 0, Static IP mode 870 - 871 -HSX1870.0 = 1, dynamic IP mode 872 -))) 873 -|=(% style="width: 160px;" %)((( 874 -HSW1871 875 -)))|(% style="width:282px" %)((( 876 -Confirm the IP, subnet mask, gateway, DNS1, DNS2, and dynamic static IP settings for Ethernet1 877 -)))|(% style="width:452px" %)((( 878 -~= 1, confirm the setting (i.e., after modifying IP-related information, set this address to 1, representing confirmation of the modification, after which it will be reset to 0) 879 -))) 880 -|=(% style="width: 160px;" %)((( 881 -HSW1872 882 -)))|(% colspan="1" rowspan="8" style="width:282px" %)((( 883 -①Display and modify DNS1 and DNS2 of Ethernet1 884 - 885 -②Related registers can be read and written mode (only static IP mode can be written) 886 -)))|(% style="width:452px" %)((( 887 -Ethernet1 Local DNS1 address high byte 1 888 -))) 889 -|=(% style="width: 160px;" %)((( 890 -HSW1873 891 -)))|(% style="width:452px" %)Ethernet1 Local DNS1 address high byte 2 892 -|=(% style="width: 160px;" %)((( 893 -HSW1874 894 -)))|(% style="width:452px" %)Ethernet1 Local DNS1 address high byte 3 895 -|=(% style="width: 160px;" %)((( 896 -HSW1875 897 -)))|(% style="width:452px" %)Ethernet1 Local DNS1 address high byte 4 898 -|=(% style="width: 160px;" %)((( 899 -HSW1876 900 -)))|(% style="width:452px" %)Ethernet1 Local DNS2 address high byte 1 901 -|=(% style="width: 160px;" %)((( 902 -HSW1877 903 -)))|(% style="width:452px" %)Ethernet1 Local DNS2 address high byte 2 904 -|=(% style="width: 160px;" %)((( 905 -HSW1878 906 -)))|(% style="width:452px" %)Ethernet1 Local DNS2 address high byte 3 907 -|=(% style="width: 160px;" %)((( 908 -HSW1879 909 -)))|(% style="width:452px" %)Ethernet1 Local DNS2 address high byte 4 910 -|=(% style="width: 160px;" %)HSW1890|(% colspan="1" style="width:282px" %)Enable refresh current network signal|(% style="width:452px" %)((( 911 -* =1: Refresh the network signal once after triggered (This register will be automatically reset after triggered, only update the signal value once after per 15 seconds, not able to update twice in the short interval) 912 -* =Others: not refresh 913 -))) 914 -|=(% style="width: 160px;" %)HSW1891|(% colspan="1" style="width:282px" %)Enable clear cache for screen data |(% style="width:452px" %)((( 915 -* =1, not clear screen cache when switch language 916 -* =2, trigger clear cache of all screens for once time 917 -* =3, always clear cache of all screen data 918 -))) 919 919 |=(% style="width: 160px;" %)HSW10000~~19999|(% style="width:282px" %)Power-down storage area|(% style="width:452px" %)After restart, the data remains 920 920 |=(% style="width: 160px;" %)HSW10035|(% rowspan="13" style="width:282px" %)((( 921 -Note: Valid when Ethernet1 of HMI is plugged into the network cable. 922 -①、When the Ethernet setting is enabled in the project parameters, this register displays the set value. 923 -②. When the Ethernet setting is not enabled in the engineering parameters, the register displays the Ethernet IP automatically acquired by the HMI. 924 -③. When the HMI is not plugged into the network cable, the register will show 0 whether the engineering parameters are set or not. 925 -④.IP related registers can be read and written (only static IP mode can be written). 664 +**✎Note: **Only valid when the HMI is plugged into the Ethernet cable. 665 + 666 +1. If Ethernet settings is enabled in project parameters, this register displays the set value. 667 +1. If Ethernet settings is not enabled in project parameters, IP would automatically obtained IP. 668 +1. If HMI is not connected to the network, the register is displayed as 0 whether the engineering parameters are set. 669 +1. 4. All IP registers of HMI are read-only. 926 926 )))|(% style="width:452px" %)Local IP address high byte 1 927 927 |=(% style="width: 160px;" %)HSW10036|(% style="width:452px" %)Local IP address high byte 2 928 928 |=(% style="width: 160px;" %)HSW10037|(% style="width:452px" %)Local IP address high byte 3 ... ... @@ -937,11 +937,9 @@ 937 937 |=(% style="width: 160px;" %)HSW10046|(% style="width:452px" %)Local gateway address high byte 4 938 938 |=(% style="width: 160px;" %)HSW10047|(% style="width:452px" %)Local port address 939 939 |=(% style="width: 160px;" %)HSW10048|(% rowspan="6" style="width:282px" %)((( 940 - ①Display the MAC code ofEthernet1NIC684 +Displays the MAC code of the current network card 941 941 942 -(hexadecimal display) 943 - 944 -②Read-only mode, not modifiable 686 +(Hexadecimal display) 945 945 )))|(% style="width:452px" %)Local MAC code high word 1 946 946 |=(% style="width: 160px;" %)HSW10049|(% style="width:452px" %)Local MAC code high word 2 947 947 |=(% style="width: 160px;" %)HSW10050|(% style="width:452px" %)Local MAC code high word 3 ... ... @@ -948,7 +948,7 @@ 948 948 |=(% style="width: 160px;" %)HSW10051|(% style="width:452px" %)Local MAC code high word 4 949 949 |=(% style="width: 160px;" %)HSW10052|(% style="width:452px" %)Local MAC code high word 5 950 950 |=(% style="width: 160px;" %)HSW10053|(% style="width:452px" %)Local MAC code high word 6 951 -|=(% style="width: 160px;" %)HSW10118|(% colspan="1" rowspan="2" style="width:282px" %)TSAP settings for HMI in the Siemens LOGO! 8 protocol|(% style="width:452px" %)HMI local TSAP, which corresponds to the remote TSAP of PLC693 +|=(% style="width: 160px;" %)HSW10118|(% colspan="1" rowspan="2" style="width:282px" %)TSAP settings for HMI in the Siemens logo! 8 protocol|(% style="width:452px" %)HMI local TSAP, which corresponds to the remote TSAP of PLC 952 952 |=(% style="width: 160px;" %)HSW10119|(% style="width:452px" %)HMI remote TSAP, which corresponds to the local TSAP of PLC 953 953 |=(% style="width: 160px;" %)HSW10461~~10493|(% style="width:282px" %)Remote access password|(% style="width:452px" %)8-character remote access password 954 954 |=(% style="width: 160px;" %)HSW10494~~10558|(% style="width:282px" %)Machine ID (Read only)|(% style="width:452px" %)Machine ID for remote access (read only 64-bit) ... ... @@ -1030,36 +1030,9 @@ 1030 1030 ))) 1031 1031 |=(% style="width: 160px;" %)HSW11760|(% style="width:282px" %)Screensaver countdown|(% style="width:452px" %)Display the countdown to enter the Screensaver, unit: second. 1032 1032 |=(% style="width: 160px;" %)HSW11761|(% style="width:282px" %)Screensaver screen number|(% style="width:452px" %)Set the screen number for Screensaver 1033 -|=(% style="width: 160px;" %)((( 1034 -HSW11762 1035 -)))|(% style="width:282px" %)((( 1036 -Dynamic screensaver control address 1037 -)))|(% style="width:452px" %)((( 1038 -HSX11762.0=0, initialize with project configuration; 1039 1039 1040 - HSX11762.0=1,initializewithspecial registerconfiguration;776 +== **Serial port communication configuration** == 1041 1041 1042 -HSX11762.1=0, disable dynamic screensaver; 1043 - 1044 -HSX11762.1=1, enable dynamic screensaver 1045 -))) 1046 -|=(% style="width: 160px;" %)((( 1047 -HSW11763 1048 -)))|(% style="width:282px" %)((( 1049 -Waiting time to enter the dynamic screensaver 1050 -)))|(% style="width:452px" %)((( 1051 -Waiting time when the screen is not operated, range 1~~720 minutes 1052 -))) 1053 -|=(% style="width: 160px;" %)((( 1054 -HSW11764 1055 -)))|(% style="width:282px" %)((( 1056 -Animated screensaver animation type 1057 -)))|(% style="width:452px" %)((( 1058 -~=0: Raster,=1: Blinds,=2: Bubble 1059 -))) 1060 - 1061 -== Serial port communication configuration == 1062 - 1063 1063 (% class="table-bordered" %) 1064 1064 |=(% scope="row" style="width: 102px;" %)Port|=(% style="width: 173px;" %)**Function**|=(% style="width: 122px;" %)**Address**|=(% colspan="2" style="width: 506px;" %)**Description** 1065 1065 |(% colspan="1" rowspan="11" style="width:102px" %)COM1|(% style="width:173px" %)Communication mode|(% style="width:122px" %)HSW10061|(% colspan="2" style="width:506px" %)((( ... ... @@ -1091,22 +1091,10 @@ 1091 1091 * =1: ODD 1092 1092 * =2: EVEN 1093 1093 ))) 1094 -|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10066|(% colspan="2" style="width:506px" %)((( 1095 -* Unit: ms. 1096 -* Range: 0 to 30000 1097 -))) 1098 -|(% style="width:173px" %)reveive timeout|(% style="width:122px" %)HSW10067|(% colspan="2" style="width:506px" %)((( 1099 -* Unit: ms. 1100 -* Range: 0 to 30000 1101 -))) 1102 -|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10068|(% colspan="2" style="width:506px" %)((( 1103 -* Unit: times. 1104 -* Range: 0 to 100 1105 -))) 1106 -|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10069|(% colspan="2" style="width:506px" %)((( 1107 -* Unit: s. 1108 -* Range: 0 to 300 1109 -))) 809 +|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10066|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000 810 +|(% style="width:173px" %)reveive timeout|(% style="width:122px" %)HSW10067|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000 811 +|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10068|(% colspan="2" style="width:506px" %)Unit: times. Range: 0~~100 812 +|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10069|(% colspan="2" style="width:506px" %)Unit: s. Range: 0~~300 1110 1110 |(% style="width:173px" %)HMI station number|(% style="width:122px" %)HSW10070|(% colspan="2" style="width:506px" %) 1111 1111 |(% style="width:173px" %)PLC station number|(% style="width:122px" %)HSW10071|(% colspan="2" style="width:506px" %) 1112 1112 |(% colspan="1" rowspan="11" style="width:102px" %)COM1-2|(% style="width:173px" %)Communication mode|(% style="width:122px" %)HSW10094|(% colspan="2" style="width:506px" %)((( ... ... @@ -1139,22 +1139,10 @@ 1139 1139 * =1: ODD 1140 1140 * =2: EVEN 1141 1141 ))) 1142 -|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10099|(% colspan="2" style="width:506px" %)((( 1143 -* Unit: ms. 1144 -* Range: 0 to 30000 1145 -))) 1146 -|(% style="width:173px" %)receive timeout|(% style="width:122px" %)HSW10100|(% colspan="2" style="width:506px" %)((( 1147 -* Unit: ms. 1148 -* Range: 0 to 30000 1149 -))) 1150 -|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10101|(% colspan="2" style="width:506px" %)((( 1151 -* Unit: times. 1152 -* Range: 0 to 100 1153 -))) 1154 -|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10102|(% colspan="2" style="width:506px" %)((( 1155 -* Unit: s. 1156 -* Range: 0 to 30 1157 -))) 845 +|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10099|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000 846 +|(% style="width:173px" %)receive timeout|(% style="width:122px" %)HSW10100|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000 847 +|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10101|(% colspan="2" style="width:506px" %)Unit: times. Range: 0~~100 848 +|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10102|(% colspan="2" style="width:506px" %)Unit: s. Range: 0~~30 1158 1158 |(% style="width:173px" %)HMI station number|(% style="width:122px" %)HSW10103|(% colspan="2" style="width:506px" %) 1159 1159 |(% style="width:173px" %)PLC station number|(% style="width:122px" %)HSW10104|(% colspan="2" style="width:506px" %) 1160 1160 |(% colspan="1" rowspan="11" style="width:102px" %)COM1-3|(% style="width:173px" %)Communication mode|(% style="width:122px" %)HSW10120|(% colspan="2" style="width:506px" %)((( ... ... @@ -1187,22 +1187,10 @@ 1187 1187 * =1: ODD 1188 1188 * =2: EVEN 1189 1189 ))) 1190 -|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10125|(% colspan="2" style="width:506px" %)((( 1191 -* Unit: ms. 1192 -* Range: 0 to 30000 1193 -))) 1194 -|(% style="width:173px" %)receive timeout|(% style="width:122px" %)HSW10126|(% colspan="2" style="width:506px" %)((( 1195 -* Unit: ms. 1196 -* Range: 0 to 30000 1197 -))) 1198 -|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10127|(% colspan="2" style="width:506px" %)((( 1199 -* Unit: times. 1200 -* Range: 0 to 100 1201 -))) 1202 -|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10128|(% colspan="2" style="width:506px" %)((( 1203 -* Unit: s. 1204 -* Range: 0 to 30 1205 -))) 881 +|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10125|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000 882 +|(% style="width:173px" %)receive timeout|(% style="width:122px" %)HSW10126|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000 883 +|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10127|(% colspan="2" style="width:506px" %)Unit: times. Range: 0~~100 884 +|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10128|(% colspan="2" style="width:506px" %)Unit: s. Range: 0~~30 1206 1206 |(% style="width:173px" %)HMI station number|(% style="width:122px" %)HSW10129|(% colspan="2" style="width:506px" %) 1207 1207 |(% style="width:173px" %)PLC station number|(% style="width:122px" %)HSW10130|(% colspan="2" style="width:506px" %) 1208 1208 |(% colspan="1" rowspan="11" style="width:102px" %)COM2|(% style="width:173px" %)Communication mode|(% style="width:122px" %)HSW10072|(% colspan="2" style="width:506px" %)((( ... ... @@ -1233,22 +1233,10 @@ 1233 1233 * =1: ODD 1234 1234 * =2: EVEN 1235 1235 ))) 1236 -|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10077|(% colspan="2" style="width:506px" %)((( 1237 -* Unit: ms. 1238 -* Range: 0 to 30000 1239 -))) 1240 -|(% style="width:173px" %)receive timeout|(% style="width:122px" %)HSW10078|(% colspan="2" style="width:506px" %)((( 1241 -* Unit: ms. 1242 -* Range: 0 to 30000 1243 -))) 1244 -|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10079|(% colspan="2" style="width:506px" %)((( 1245 -* Unit: times. 1246 -* Range: 0 to 100 1247 -))) 1248 -|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10080|(% colspan="2" style="width:506px" %)((( 1249 -* Unit: s. 1250 -* Range: 0 to 30 1251 -))) 915 +|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10077|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000 916 +|(% style="width:173px" %)receive timeout|(% style="width:122px" %)HSW10078|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000 917 +|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10079|(% colspan="2" style="width:506px" %)Unit: times. Range: 0~~100 918 +|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10080|(% colspan="2" style="width:506px" %)Unit: s. Range: 0~~30 1252 1252 |(% style="width:173px" %)HMI station number|(% style="width:122px" %)HSW10081|(% colspan="2" style="width:506px" %) 1253 1253 |(% style="width:173px" %)PLC station number|(% style="width:122px" %)HSW10082|(% colspan="2" style="width:506px" %) 1254 1254 |(% colspan="1" rowspan="11" style="width:102px" %)COM2-2|(% style="width:173px" %)Communication mode|(% style="width:122px" %)HSW10105|(% colspan="2" style="width:506px" %)((( ... ... @@ -1279,22 +1279,10 @@ 1279 1279 * =1: ODD 1280 1280 * =2: EVEN 1281 1281 ))) 1282 -|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10110|(% colspan="2" style="width:506px" %)((( 1283 -* Unit: ms. 1284 -* Range: 0 to 30000 1285 -))) 1286 -|(% style="width:173px" %)receive timeout|(% style="width:122px" %)HSW10111|(% colspan="2" style="width:506px" %)((( 1287 -* Unit: ms. 1288 -* Range: 0 to 30000 1289 -))) 1290 -|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10112|(% colspan="2" style="width:506px" %)((( 1291 -* Unit: times. 1292 -* Range: 0 to 100 1293 -))) 1294 -|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10113|(% colspan="2" style="width:506px" %)((( 1295 -* Unit: s. 1296 -* Range: 0 to 30 1297 -))) 949 +|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10110|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000 950 +|(% style="width:173px" %)receive timeout|(% style="width:122px" %)HSW10111|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000 951 +|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10112|(% colspan="2" style="width:506px" %)Unit: times. Range: 0~~100 952 +|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10113|(% colspan="2" style="width:506px" %)Unit: s. Range: 0~~30 1298 1298 |(% style="width:173px" %)HMI station number|(% style="width:122px" %)HSW10114|(% colspan="2" style="width:506px" %) 1299 1299 |(% style="width:173px" %)PLC station number|(% style="width:122px" %)HSW10115|(% colspan="2" style="width:506px" %) 1300 1300 |(% colspan="1" rowspan="11" style="width:102px" %)COM3|(% style="width:173px" %)Communication mode|(% style="width:122px" %)HSW10083|(% colspan="2" style="width:506px" %)((( ... ... @@ -1324,48 +1324,29 @@ 1324 1324 * =1: ODD 1325 1325 * =2: EVEN 1326 1326 ))) 1327 -|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10088|(% colspan="2" style="width:506px" %)((( 1328 -* Unit: ms. 1329 -* Range: 0 to 30000 1330 -))) 1331 -|(% style="width:173px" %)receive timeout|(% style="width:122px" %)HSW10089|(% colspan="2" style="width:506px" %)((( 1332 -* Unit: ms. 1333 -* Range: 0 to 30000 1334 -))) 1335 -|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10090|(% colspan="2" style="width:506px" %)((( 1336 -* Unit: times. 1337 -* Range: 0 to 100 1338 -))) 1339 -|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10091|(% colspan="2" style="width:506px" %)((( 1340 -* Unit: s. 1341 -* Range: 0 to 30 1342 -))) 982 +|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10088|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000 983 +|(% style="width:173px" %)receive timeout|(% style="width:122px" %)HSW10089|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000 984 +|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10090|(% colspan="2" style="width:506px" %)Unit: times. Range: 0~~100 985 +|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10091|(% colspan="2" style="width:506px" %)Unit: s. Range: 0~~30 1343 1343 |(% style="width:173px" %)HMI station number|(% style="width:122px" %)HSW10092|(% colspan="2" style="width:506px" %) 1344 1344 |(% style="width:173px" %)PLC station number|(% style="width:122px" %)HSW10093|(% colspan="2" style="width:506px" %) 1345 1345 |(% colspan="1" rowspan="2" style="width:102px" %)CAN port|(% style="width:173px" %)CAN1 baud rate|(% style="width:122px" %)HSW010116|(% style="width:299px" %)((( 1346 -Unit: K, the baud rate must be an integer. 1347 - 1348 -For example, when the baud rate required is 250000, just enter 250. 989 +Unit: K, the baud rate must be an integer, for example, when the baud rate required is 250000, just enter 250. 1349 1349 )))|(% colspan="1" rowspan="2" style="width:218px" %)**✎Note: **If baud rate has been modified,please wait 5 seconds,then restart the HMI to take effect. 1350 -|(% style="width:173px" %)CAN2 baud rate|(% style="width:122px" %)HSW010117|(% style="width:299px" %)((( 1351 -Unit: K, the baud rate must be an integer. 991 +|(% style="width:173px" %)CAN2 baud rate|(% style="width:122px" %)HSW010117|(% style="width:299px" %)Unit: K, the baud rate must be an integer, for example, when the baud rate required is 250000, just enter 250. 1352 1352 1353 -For example, when the baud rate required is 250000, just enter 250. 1354 -))) 993 +== **Ethernet communication configuration** == 1355 1355 1356 -== Ethernet communication configuration == 1357 - 1358 1358 (% class="table-bordered" %) 1359 -|(% style="width:40px" %)**No.**|(% style="width:295px" %)**Function**|(% style="width:220px" %)**Address**|(% style="width:336px" %)**Description** 996 +|=(% style="width: 40px;" %)**No.**|=(% style="width: 295px;" %)**Function**|=(% style="width: 220px;" %)**Address**|=(% style="width: 336px;" %)**Description** 1360 1360 |(% rowspan="7" style="width:40px" %)1|(% colspan="1" rowspan="7" style="width:295px" %)Ethernet parameter configuration for communication number 1 in list. Configure those addresses according to connected device. After configuration, wait for 5 seconds and restart the HMI.|(% style="width:220px" %)HSW11004|(% style="width:336px" %)Device IP address high word 1 1361 1361 |(% style="width:220px" %)HSW11005|(% style="width:336px" %)Device IP address high word 2 1362 1362 |(% style="width:220px" %)HSW11006|(% style="width:336px" %)Device IP address high word 3 1363 1363 |(% style="width:220px" %)HSW11007|(% style="width:336px" %)Device IP address high word 4 1364 1364 |(% style="width:220px" %)HSW11008|(% style="width:336px" %)Device Port number 1365 -|(% style="width:220px" %)HSW11009|(% style="width:336px" %)((( 1366 -~=2 TCP 1367 - 1368 -~=3 UDP 1002 +|(% style="width:220px" %)HSW11009|=(% style="width: 336px;" %)((( 1003 +* =2 TCP 1004 +* =3 UDP 1369 1369 ))) 1370 1370 |(% style="width:220px" %)HSW11010|(% style="width:336px" %)Reserved 1371 1371 |(% rowspan="7" style="width:40px" %)2|(% colspan="1" rowspan="7" style="width:295px" %)Ethernet parameter configuration for communication number 2 in list. Configure those addresses according to connected device. After configuration, wait for 5 seconds and restart the HMI.|(% style="width:220px" %)HSW11011|(% style="width:336px" %)Device IP address high word 1 ... ... @@ -1373,10 +1373,9 @@ 1373 1373 |(% style="width:220px" %)HSW11013|(% style="width:336px" %)Device IP address high word 3 1374 1374 |(% style="width:220px" %)HSW11014|(% style="width:336px" %)Device IP address high word 4 1375 1375 |(% style="width:220px" %)HSW11015|(% style="width:336px" %)Device Port number 1376 -|(% style="width:220px" %)HSW11016|(% style="width:336px" %)((( 1377 -~=2 TCP 1378 - 1379 -~=3 UDP 1012 +|(% style="width:220px" %)HSW11016|=(% style="width: 336px;" %)((( 1013 +* =2 TCP 1014 +* =3 UDP 1380 1380 ))) 1381 1381 |(% style="width:220px" %)HSW11017|(% style="width:336px" %)Reserved 1382 1382 |(% style="width:40px" %)…|(% style="width:295px" %) |(% style="width:220px" %)…|(% style="width:336px" %)… ... ... @@ -1385,11 +1385,7 @@ 1385 1385 |(% style="width:220px" %)HSW11223|(% style="width:336px" %)Device IP address high word 3 1386 1386 |(% style="width:220px" %)HSW11224|(% style="width:336px" %)Device IP address high word 4 1387 1387 |(% style="width:220px" %)HSW11225|(% style="width:336px" %)Device Port number 1388 -|(% style="width:220px" %)HSW11226|(% style="width:336px" %)((( 1389 -~=2 TCP; 1390 - 1391 -~=3 UDP 1392 -))) 1023 +|(% style="width:220px" %)HSW11226|=(% style="width: 336px;" %)2 TCP; =3 UDP 1393 1393 |(% style="width:220px" %)HSW11227|(% style="width:336px" %)Reserved 1394 1394 1395 1395 (% class="box infomessage" %) ... ... @@ -1397,7 +1397,7 @@ 1397 1397 **✎Note:** The number of Ethernet connections supported by different HMI series varies. 1398 1398 ))) 1399 1399 1400 -== Communication control == 1031 +== **Communication control** == 1401 1401 1402 1402 (% class="table-bordered" %) 1403 1403 |=(% style="width: 135px;" %)**Communication No.**|=(% style="width: 102px;" %)**Station No.**|=(% style="width: 185px;" %)**Control bit**|=(% style="width: 191px;" %)**Communication lamp**|=(% style="width: 271px;" %)**Description**