Changes for page 13 HMI Internal Registers

Last modified by Jett on 2025/04/28 16:07

From version 19.1
edited by Hunter
on 2023/02/18 14:04
Change comment: There is no comment for this version
To version 13.1
edited by Bob
on 2023/01/07 14:30
Change comment: There is no comment for this version

Summary

Details

Page properties
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.Hunter
1 +XWiki.Bob
Content
... ... @@ -25,19 +25,6 @@
25 25  * The address of the bit address HDX is with a decimal point while word addresses are integers.
26 26  )))
27 27  
28 -= Address ranges table =
29 -
30 -|=(% scope="row" style="width: 218px;" %)Address Type\HMI Series|=(% style="width: 228px;" %)General Series|=(% style="width: 200px;" %)i Series/HMI+ models|=(% style="width: 136px;" %)ie Series|=(% style="width: 232px;" %)ig Series
31 -|=(% style="width: 218px;" %)HDW|(% style="width:228px" %)HDW0-HDW299999|HDW0-HDW299999|HDW0-HDW299999|HDW0-HDW299999
32 -|=(% style="width: 218px;" %)HSW|(% style="width:228px" %)HSW0-HSW14999|HSW0-HSW14999|HSW0-HSW14999|HSW0-HSW14999
33 -|=(% style="width: 218px;" %)HAW|(% style="width:228px" %)HAW0-HAW199999|HAW0-HAW199999|HAW0-HAW199999|HAW0-HAW199999
34 -|=(% style="width: 218px;" %)HUW|(% style="width:228px" %)HUW0-HUW1599|HUW0-HUW1599|HUW0-HUW1599|HUW0-HUW1599
35 -|=(% style="width: 218px;" %)HDX|(% style="width:228px" %)HDX0.0-HDX299999.15|HDX0.0-HDX299999.15|HDX0.0-HDX299999.15|HDX0.0-HDX299999.15
36 -|=(% style="width: 218px;" %)HSX|(% style="width:228px" %)HSX0.0-HSX14999.15|HSX0.0-HSX14999.15|HSX0-HSX14999.15|HSX0.0-HSX14999.15
37 -|=(% style="width: 218px;" %)HAX|(% style="width:228px" %)HAX0.0-HAX199999.15|HAX0.0-HAX199999.15|HAX0.0-HAX199999.15|HAX0.0-HAX199999.15
38 -|=(% style="width: 218px;" %)HUX|(% style="width:228px" %)HUX0.0-HUX1599.15|HUX0.0-HUX1599.15|HUX0.0-HUX1599.15|HUX0.0-HUX1599.15
39 -|=(% style="width: 218px;" %)RPW|(% style="width:228px" %) |RPW000000-RPW990450|RPW000000-RPW990450|RPW000000-RPW990450
40 -
41 41  = **Data storage area (HDW/HDX)** =
42 42  
43 43  It is used to save the temporary data of project.
... ... @@ -254,8 +254,8 @@
254 254  * =2: HSX521.1=1, delete all trend graph.
255 255  * =4: HSX521.2=1, delete all alarms.
256 256  * =16: HSX521.4=1, delete history XY plot.
257 -* =32: HSX521.5=1, delete data records in SD card or USB flash disk;(Please make a setting which is saved to USB flash disk or SD card in project setting).
258 -* =64: HSX521.6=1, delete alarms records in SD card or USB flash disk; (Please make a setting which is saved to USB flash disk or SD card in project setting).
244 +* =32: HSX521.5=1, delete data records in SD card or flash dish;(Please make a setting which is saved to flash disk or SD card in project setting).
245 +* =64: HSX521.6=1, delete alarms records in SD card or flash dish; (Please make a setting which is saved to flash disk or SD card in project setting).
259 259  )))
260 260  |=(% style="width: 160px;" %)HSW522|(% style="width:282px" %)Copy and paste the alarm/data files in flash to the USB flash disk|(% style="width:452px" %)(((
261 261  * =0: No operation
... ... @@ -498,8 +498,6 @@
498 498  * =0, Default value
499 499  * =1, Release the alarm generated before the last power-down when starting up
500 500  )))
501 -|=(% style="width: 160px;" %)HSW1200|(% colspan="1" rowspan="2" style="width:282px" %)TSAP settings for HMI in the Siemens LOGO! 8 protocol(ig series or HMI V2.0)|(% style="width:452px" %)HMI local TSAP, which corresponds to the remote TSAP of PLC
502 -|=(% style="width: 160px;" %)HSW1201|(% style="width:452px" %)HMI remote TSAP, which corresponds to the local TSAP of PLC
503 503  |=(% style="width: 160px;" %)HSW1450|(% style="width:282px" %)Enable objects level password function|(% style="width:452px" %)(((
504 504  * =0, Disable
505 505  * =1, Enable
... ... @@ -606,9 +606,6 @@
606 606  * =0: Server connection exception
607 607  * =1: Server connection is OK
608 608  )))
609 -|=(% style="width: 160px;" %)HSW1740|(% style="width:282px" %)Wi-fi signal strength|(% style="width:452px" %)(((
610 -Display the value of Wi-fi signal signal strength, ranges from 0~~100 (Signal strength is automatically obtained only once when HMI is powered on, and it will not be automatically updated. It needs to be used with the HSW1890)
611 -)))
612 612  |=(% style="width: 160px;" %)HSW1741|(% colspan="1" rowspan="12" style="width:282px" %)Related IP register in 4Gnetwork status (It is valid when HMI is connected to 4G)|(% style="width:452px" %)Local IP address high byte 1
613 613  |=(% style="width: 160px;" %)HSW1742|(% style="width:452px" %)Local IP address high byte 2
614 614  |=(% style="width: 160px;" %)HSW1743|(% style="width:452px" %)Local IP address high byte 3
... ... @@ -808,8 +808,6 @@
808 808  |=(% style="width: 160px;" %)HSW1853|(% style="width:282px" %)File format for exporting data records to USB flash drive or SD card|(% style="width:452px" %)(((
809 809  * =0: db database
810 810  * =1: CSV
811 -
812 -(Only valid for script function DbToCsvFile)
813 813  )))
814 814  |=(% style="width: 160px;" %)HSW1854|(% style="width:282px" %)High and low word conversion type|(% style="width:452px" %)(((
815 815  * =0: use the old high-low word conversion (default)
... ... @@ -836,7 +836,7 @@
836 836  * =1: priority WLAN
837 837  * =2: priority 4G
838 838  )))
839 -|=(% style="width: 160px;" %)HSW1866|(% style="width:282px" %)Delete the Lua extension module file|(% style="width:452px" %)(((
819 +|=(% style="width: 160px;" %)HSW1866|(% style="width:282px" %)Delete the LUa extension module file|(% style="width:452px" %)(((
840 840  * =0: delete;
841 841  * = Others: do not delete
842 842  )))
... ... @@ -905,15 +905,6 @@
905 905  |=(% style="width: 160px;" %)(((
906 906  HSW1879
907 907  )))|(% style="width:452px" %)Ethernet1 Local DNS2 address high byte 4
908 -|=(% style="width: 160px;" %)HSW1890|(% colspan="1" style="width:282px" %)Enable refresh current network signal|(% style="width:452px" %)(((
909 -* =1: Refresh the network signal once after triggered (This register will be automatically reset after triggered, only update the signal value once after per 15 seconds, not able to update twice in the short interval)
910 -* =Others: not refresh
911 -)))
912 -|=(% style="width: 160px;" %)HSW1891|(% colspan="1" style="width:282px" %)Enable clear cache for screen data  |(% style="width:452px" %)(((
913 -* =1, not clear screen cache when switch language
914 -* =2, trigger clear cache of all screens for once time
915 -* =3, always clear cache of all screen data
916 -)))
917 917  |=(% style="width: 160px;" %)HSW10000~~19999|(% style="width:282px" %)Power-down storage area|(% style="width:452px" %)After restart, the data remains
918 918  |=(% style="width: 160px;" %)HSW10035|(% rowspan="13" style="width:282px" %)(((
919 919  Note: Valid when Ethernet1 of HMI is plugged into the network cable.
... ... @@ -946,7 +946,7 @@
946 946  |=(% style="width: 160px;" %)HSW10051|(% style="width:452px" %)Local MAC code high word 4
947 947  |=(% style="width: 160px;" %)HSW10052|(% style="width:452px" %)Local MAC code high word 5
948 948  |=(% style="width: 160px;" %)HSW10053|(% style="width:452px" %)Local MAC code high word 6
949 -|=(% style="width: 160px;" %)HSW10118|(% colspan="1" rowspan="2" style="width:282px" %)TSAP settings for HMI in the Siemens LOGO! 8 protocol|(% style="width:452px" %)HMI local TSAP, which corresponds to the remote TSAP of PLC
920 +|=(% style="width: 160px;" %)HSW10118|(% colspan="1" rowspan="2" style="width:282px" %)TSAP settings for HMI in the Siemens logo! 8 protocol|(% style="width:452px" %)HMI local TSAP, which corresponds to the remote TSAP of PLC
950 950  |=(% style="width: 160px;" %)HSW10119|(% style="width:452px" %)HMI remote TSAP, which corresponds to the local TSAP of PLC
951 951  |=(% style="width: 160px;" %)HSW10461~~10493|(% style="width:282px" %)Remote access password|(% style="width:452px" %)8-character remote access password
952 952  |=(% style="width: 160px;" %)HSW10494~~10558|(% style="width:282px" %)Machine ID (Read only)|(% style="width:452px" %)Machine ID for remote access (read only 64-bit)
... ... @@ -1033,13 +1033,7 @@
1033 1033  )))|(% style="width:282px" %)(((
1034 1034  Dynamic screensaver control address
1035 1035  )))|(% style="width:452px" %)(((
1036 -HSX11762.0=0, initialize with project configuration;
1037 -
1038 -HSX11762.0=1, initialize with special register configuration;
1039 -
1040 -HSX11762.1=0, disable dynamic screensaver;
1041 -
1042 -HSX11762.1=1, enable dynamic screensaver
1007 +HSX11762.0: =0, initialize with project configuration; =1, initialize with special register configuration; HSX11762.1: =0, disable dynamic screensaver; =1, enable dynamic screensaver
1043 1043  )))
1044 1044  |=(% style="width: 160px;" %)(((
1045 1045  HSW11763
... ... @@ -1053,7 +1053,7 @@
1053 1053  )))|(% style="width:282px" %)(((
1054 1054  Animated screensaver animation type
1055 1055  )))|(% style="width:452px" %)(((
1056 -~=0: Raster,=1: Blinds,=2: Bubble
1021 +~=0:lattice,=1:shutter,=2:bubble
1057 1057  )))
1058 1058  
1059 1059  == Serial port communication configuration ==