... ... @@ -4,27 +4,26 @@
4 4  
5 5  *HSW, HDW, HUW, HAW are word address, HSX, HDX, HUX, HAX are bit address.
6 6  
7 -1. **System data area (HSW): **A special register defined by the system.
8 -1. **Data storage area (HDW/HDX): **Users store user data.
9 -1. **System data area (HUW): **A special register defined by the system.
10 -1. **System Data (HAW)**: System register used for power-off save.
11 -1. **Recipe index area (RPW): **System register used for recipe index.
7 +* **System data area (HSW): **A special register defined by the system.
8 +* **Data storage area (HDW/HDX): **Users store user data.
9 +* **System data area (HUW): **A special register defined by the system.
10 +* **System Data (HAW)**: System register used for power-off save.
11 +* **Recipe index area (RPW): **System register used for recipe index.
12 12  
13 13  HMI internal registers are divided into bit address and word address, which can be accessed in two ways (take HDW as an example).
14 14  
15 -1. Access as word with the prefix "HDW".
15 +* Access as word with the prefix "HDW".
16 +** HDW0 means the 1st word of system data area. HDW1 means the 2nd word of system data area.
17 +* Access as bit with the prefix "HDX".  The number before "." i".  The number before Access in bit with the prefix "HD".  The number before Access in bit with the prefix "HDX". The number before "." indicates the number of the word. The number after "." indicates the bit number of the word.
18 +** HDX1020.12 means to access the system data area in bit mode, the specific location is the 13th bit of the 1020 word.
16 16  
17 -* HDW0 means the 1st word of system data area. HDW1 means the 2nd word of system data area.
18 -
19 -(% start="2" %)
20 -1. Access as bit with the prefix "HDX".  The number before "." i".  The number before Access in bit with the prefix "HD".  The number before Access in bit with the prefix "HDX". The number before "." indicates the number of the word. The number after "." indicates the bit number of the word.
21 -
22 -* HDX1020.12 means to access the system data area in bit mode, the specific location is the 13th bit of the 1020 word.
23 -
20 +(% class="box infomessage" %)
21 +(((
24 24  **✎Note:**
25 25  
26 26  * Addresses in HDX are the bits from words in HDW, so be careful when using addresses. For example, HDX1020.12 is the 13th bit to access the 1020 word. The value of this bit is the same as that of the word accessed through HDW001020. The 13th bit of this word is actually the same bit as HDX1020.12.
27 27  * The address of the bit address HDX is with a decimal point while word addresses are integers.
26 +)))
28 28  
29 29  = **Data storage area (HDW/HDX)** =
30 30  
... ... @@ -40,10 +40,13 @@
40 40  1. Access as word, and serial number range is from HAW0 to HAW199999.
41 41  1. Access as bit, and serial number range is from HAX0.0 to HAX199999.15.
42 42  
42 +(% class="box infomessage" %)
43 +(((
43 43  **✎Note:**
44 44  
45 45  * HAW/HAX is power-down retention. The register of this type is able to save the data before the power-down.
46 46  * To avoid possible device failure, do not immediately power off and reboot when configuring the power-down save addre
48 +)))
47 47  
48 48  = **Recipe index area (RPW)** =
49 49  
... ... @@ -337,9 +337,11 @@
337 337  * HDX882.1=0 SD card doesn't execute storage or storage finished.
338 338  * HDX882.1=1 SD card is reading data, don't remove SD card.
339 339  )))
340 -|=(% style="width: 160px;" %)HSW884|(% style="width:282px" %)Enter setup screen|(% style="width:452px" %)(((
341 -* = 0: Do not into setup screen
342 -* = 1: Enter setup screen
342 +|=(% style="width: 160px;" %)HSW884|(% style="width:282px" %)Enter the system network configuration interface|(% style="width:452px" %)(((
343 +* =0: Do not enter the network configuration interface
344 +* =1: Enter the system network configuration interface.
345 +** ig series HMI only supports to enter the system interface
346 +
343 343  )))
344 344  |=(% style="width: 160px;" %)HSW885|(% style="width:282px" %)When the control object hides the address is read failed (communication failure), set the display mode of the object|(% style="width:452px" %)(((
345 345  * = 0: displayed by object setting.
... ... @@ -508,6 +508,10 @@
508 508  * HSX1502.0=1: Modification comfirmed. Save the data of HSW1450~~HSW1501 to a file for immediate effect.
509 509  * HSX1502.1=1:Modification cancelled. Restore the current data of hSW1450-HSW1501 to the data saved in the file last time.
510 510  )))
515 +|=(% style="width: 160px;" %)HSW1509|(% style="width:282px" %)Curve width|(% style="width:452px" %)(((
516 +* =0: Use the curve width set by project default.
517 +* =1 to 10: use special register to set curve width.
518 +)))
511 511  |=(% style="width: 160px;" %)HSW1603|(% style="width:282px" %)Number of current unreleased alarms|(% style="width:452px" %)The number of current unreleased alarms in alarm record file.
512 512  |=(% style="width: 160px;" %)HSW1604|(% style="width:282px" %)The auxiliary judgment address when the control bit in the Object Lock fails to be read|(% style="width:452px" %)(((
513 513  * =0: The auxiliary address is invalid.
... ... @@ -610,6 +610,174 @@
610 610  * =1: Server connection is OK
611 611  )))
612 612  |=(% style="width: 160px;" %)HSW1761|(% style="width:282px" %)Display 4G network signal strength|(% style="width:452px" %)Signal strength: 0~~31. The greater the value ,the signal is stronger
621 +|=(% style="width: 160px;" %)(((
622 +HSW1762
623 +)))|(% colspan="1" rowspan="13" style="width:282px" %)(((
624 +Note: Valid when Ethernet2 of HMI is plugged into the network cable.
625 +①、When the Ethernet setting is enabled in the project parameters, this register displays the set value.
626 +②. When the Ethernet setting is not enabled in the engineering parameters, the register displays the Ethernet IP automatically acquired by the HMI.
627 +③. When the HMI is not plugged into the network cable, the register will show 0 whether the engineering parameters are set or not.
628 +④.IP related registers can be read and written (only static IP mode can be written).
629 +)))|(% style="width:452px" %)(((
630 +Ethernet2 Local IP address high byte 1
631 +)))
632 +|=(% style="width: 160px;" %)(((
633 +HSW1763
634 +)))|(% style="width:452px" %)(((
635 +Ethernet2 Local IP address high byte 2
636 +)))
637 +|=(% style="width: 160px;" %)(((
638 +HSW1764
639 +)))|(% style="width:452px" %)(((
640 +Ethernet2 Local IP address high byte 3
641 +)))
642 +|=(% style="width: 160px;" %)(((
643 +HSW1765
644 +)))|(% style="width:452px" %)(((
645 +Ethernet2 Local IP address high byte 4
646 +)))
647 +|=(% style="width: 160px;" %)(((
648 +HSW1766
649 +)))|(% style="width:452px" %)(((
650 +Ethernet2 Local mask IP address high byte 1
651 +)))
652 +|=(% style="width: 160px;" %)(((
653 +HSW1767
654 +)))|(% style="width:452px" %)(((
655 +Ethernet2 Local mask IP address high byte 2
656 +)))
657 +|=(% style="width: 160px;" %)(((
658 +HSW1768
659 +)))|(% style="width:452px" %)Ethernet2 Local mask IP address high byte 3
660 +|=(% style="width: 160px;" %)HSW1769|(% style="width:452px" %)Ethernet2 Local mask IP address high byte 4
661 +|=(% style="width: 160px;" %)(((
662 +HSW1770
663 +)))|(% style="width:452px" %)(((
664 +Ethernet2 Local gateway IP address high byte 1
665 +)))
666 +|=(% style="width: 160px;" %)(((
667 +HSW1771
668 +)))|(% style="width:452px" %)(((
669 +Ethernet2 Local gateway IP address high byte 2
670 +)))
671 +|=(% style="width: 160px;" %)(((
672 +HSW1772
673 +)))|(% style="width:452px" %)(((
674 +Ethernet2 Local gateway IP address high byte 3
675 +)))
676 +|=(% style="width: 160px;" %)(((
677 +HSW1773
678 +)))|(% style="width:452px" %)(((
679 +Ethernet2 Local gateway IP address high byte 4
680 +)))
681 +|=(% style="width: 160px;" %)(((
682 +HSW1774
683 +)))|(% style="width:452px" %)(((
684 +Ethernet2 Local Port Address
685 +)))
686 +|=(% style="width: 160px;" %)(((
687 +HSW1775
688 +)))|(% colspan="1" rowspan="6" style="width:282px" %)(((
689 +①Display the MAC code of Ethernet2 NIC
690 +
691 +(hexadecimal display)
692 +
693 +②Read-only mode, not modifiable
694 +)))|(% style="width:452px" %)(((
695 +Ethernet2 Local MAC code high byte 1
696 +)))
697 +|=(% style="width: 160px;" %)(((
698 +HSW1776
699 +)))|(% style="width:452px" %)(((
700 +Ethernet2 Local MAC code high byte 2
701 +)))
702 +|=(% style="width: 160px;" %)(((
703 +HSW1777
704 +)))|(% style="width:452px" %)(((
705 +Ethernet2 Local MAC code high byte 3
706 +)))
707 +|=(% style="width: 160px;" %)(((
708 +HSW1778
709 +)))|(% style="width:452px" %)(((
710 +Ethernet2 Local MAC code high byte 4
711 +)))
712 +|=(% style="width: 160px;" %)(((
713 +HSW1779
714 +)))|(% style="width:452px" %)(((
715 +Ethernet2 Local MAC code high byte 5
716 +)))
717 +|=(% style="width: 160px;" %)(((
718 +HSW1780
719 +)))|(% style="width:452px" %)(((
720 +Ethernet2 Local MAC code high byte 6
721 +)))
722 +|=(% style="width: 160px;" %)(((
723 +HSW1781
724 +)))|(% colspan="1" rowspan="8" style="width:282px" %)(((
725 +①Display and modify DNS1 and DNS2 of Ethernet2
726 +
727 +②Related registers can be read and written mode (only static IP mode can be written)
728 +)))|(% style="width:452px" %)(((
729 +Ethernet2 Local DNS1 address high byte 1
730 +)))
731 +|=(% style="width: 160px;" %)(((
732 +HSW1782
733 +)))|(% style="width:452px" %)(((
734 +Ethernet2 Local DNS1 address high byte 2
735 +)))
736 +|=(% style="width: 160px;" %)(((
737 +HSW1783
738 +)))|(% style="width:452px" %)(((
739 +Ethernet2 Local DNS1 address high byte 3
740 +)))
741 +|=(% style="width: 160px;" %)(((
742 +HSW1784
743 +)))|(% style="width:452px" %)(((
744 +Ethernet2 Local DNS1 address high byte 4
745 +)))
746 +|=(% style="width: 160px;" %)(((
747 +HSW1785
748 +)))|(% style="width:452px" %)(((
749 +Ethernet2 Local DNS2 address high byte 1
750 +)))
751 +|=(% style="width: 160px;" %)(((
752 +HSW1786
753 +)))|(% style="width:452px" %)(((
754 +Ethernet2 Local DNS2 address high byte 2
755 +)))
756 +|=(% style="width: 160px;" %)(((
757 +HSW1787
758 +)))|(% style="width:452px" %)(((
759 +Ethernet2 Local DNS2 address high byte 3
760 +)))
761 +|=(% style="width: 160px;" %)(((
762 +HSW1788
763 +)))|(% style="width:452px" %)(((
764 +Ethernet2 Local DNS2 address high byte 4
765 +)))
766 +|=(% style="width: 160px;" %)(((
767 +HSW1789
768 +)))|(% colspan="1" style="width:282px" %)(((
769 +Display or set the dynamic or static IP mode of Ethernet2
770 +)))|(% style="width:452px" %)(((
771 +HSX1789.0 = 0, Static IP mode
772 +
773 +HSX1789.0 = 1, dynamic IP mode
774 +)))
775 +|=(% style="width: 160px;" %)(((
776 +HSW1790
777 +)))|(% colspan="1" style="width:282px" %)(((
778 +Confirm Ethernet2 IP, subnet mask, gateway, DNS1, DNS2, and dynamic static IP settings
779 +)))|(% style="width:452px" %)(((
780 +~= 1, confirm the setting (i.e., after modifying IP-related information, set this address to 1, representing confirmation of the modification, after which it will be reset to 0)
781 +)))
782 +|=(% style="width: 160px;" %)(((
783 +HSW1791
784 +)))|(% colspan="1" style="width:282px" %)(((
785 +Network status of the Ethernet2 connection server
786 +)))|(% style="width:452px" %)(((
787 +~= 0, connection to the server is abnormal = 1, connection to the server is normal
788 +)))
613 613  |=(% style="width: 160px;" %)HSW1852|(% style="width:282px" %)Control the interval in two consecutive clicks|(% style="width:452px" %)Limit range: 1~~500ms. The default is 100 ms.
614 614  |=(% style="width: 160px;" %)HSW1853|(% style="width:282px" %)File format for exporting data records to USB flash drive or SD card|(% style="width:452px" %)(((
615 615  * =0: db database
... ... @@ -635,14 +635,87 @@
635 635  * =1: download firmware
636 636  * =2: enter the background
637 637  )))
814 +|=(% style="width: 160px;" %)HSW1865|(% style="width:282px" %)Priority connection to the cloud|(% style="width:452px" %)(((
815 +* =0: priority Ethernet
816 +* =1: priority WLAN
817 +* =2: priority 4G
818 +)))
819 +|=(% style="width: 160px;" %)HSW1866|(% style="width:282px" %)Delete the LUa extension module file|(% style="width:452px" %)(((
820 +* =0: delete;
821 +* = Others: do not delete
822 +)))
823 +|=(% style="width: 160px;" %)HSW1867|(% style="width:282px" %)Reset mode|(% style="width:452px" %)(((
824 +Monitor address is set during reset of reset switch, whether to cancel reset,
825 +
826 +* = 0: yes (default);
827 +* = 1: no
828 +)))
829 +|=(% style="width: 160px;" %)HSW1868|(% style="width:282px" %)Double-click or long press the record type table mode|(% style="width:452px" %)(((
830 +Controls whether the button pops up when double-clicking or long pressing on record type table object
831 +
832 +* = 0: yes (default);
833 +* = 1: no
834 +)))
835 +|=(% style="width: 160px;" %)(((
836 +HSW1869
837 +)))|(% style="width:282px" %)(((
838 +Dynamic screensaver countdown
839 +)))|(% style="width:452px" %)(((
840 +Countdown to enter dynamic screensaver effect, unit (S)
841 +)))
842 +|=(% style="width: 160px;" %)(((
843 +HSW1870
844 +)))|(% style="width:282px" %)(((
845 +Display or set the dynamic or static IP mode of Ethernet1
846 +)))|(% style="width:452px" %)(((
847 +HSX1870.0 = 0, Static IP mode
848 +
849 +HSX1870.0 = 1, dynamic IP mode
850 +)))
851 +|=(% style="width: 160px;" %)(((
852 +HSW1871
853 +)))|(% style="width:282px" %)(((
854 +Confirm the IP, subnet mask, gateway, DNS1, DNS2, and dynamic static IP settings for Ethernet1
855 +)))|(% style="width:452px" %)(((
856 +~= 1, confirm the setting (i.e., after modifying IP-related information, set this address to 1, representing confirmation of the modification, after which it will be reset to 0)
857 +)))
858 +|=(% style="width: 160px;" %)(((
859 +HSW1872
860 +)))|(% colspan="1" rowspan="8" style="width:282px" %)(((
861 +①Display and modify DNS1 and DNS2 of Ethernet1
862 +
863 +②Related registers can be read and written mode (only static IP mode can be written)
864 +)))|(% style="width:452px" %)(((
865 +Ethernet1 Local DNS1 address high byte 1
866 +)))
867 +|=(% style="width: 160px;" %)(((
868 +HSW1873
869 +)))|(% style="width:452px" %)Ethernet1 Local DNS1 address high byte 2
870 +|=(% style="width: 160px;" %)(((
871 +HSW1874
872 +)))|(% style="width:452px" %)Ethernet1 Local DNS1 address high byte 3
873 +|=(% style="width: 160px;" %)(((
874 +HSW1875
875 +)))|(% style="width:452px" %)Ethernet1 Local DNS1 address high byte 4
876 +|=(% style="width: 160px;" %)(((
877 +HSW1876
878 +)))|(% style="width:452px" %)Ethernet1 Local DNS2 address high byte 1
879 +|=(% style="width: 160px;" %)(((
880 +HSW1877
881 +)))|(% style="width:452px" %)Ethernet1 Local DNS2 address high byte 2
882 +|=(% style="width: 160px;" %)(((
883 +HSW1878
884 +)))|(% style="width:452px" %)Ethernet1 Local DNS2 address high byte 3
885 +|=(% style="width: 160px;" %)(((
886 +HSW1879
887 +)))|(% style="width:452px" %)Ethernet1 Local DNS2 address high byte 4
638 638  |=(% style="width: 160px;" %)HSW10000~~19999|(% style="width:282px" %)Power-down storage area|(% style="width:452px" %)After restart, the data remains
639 639  |=(% style="width: 160px;" %)HSW10035|(% rowspan="13" style="width:282px" %)(((
640 -**✎Note: **Only valid when the HMI is plugged into the Ethernet cable.
641 -
642 -1. If Ethernet settings is enabled in project parameters, this register displays the set value.
643 -1. If Ethernet settings is not enabled in project parameters, IP would automatically obtained IP.
644 -1. If HMI is not connected to the network, the register is displayed as 0 whether the engineering parameters are set.
645 -1. 4. All IP registers of HMI are read-only.
890 +Note: Valid when Ethernet1 of HMI is plugged into the network cable.
891 +①、When the Ethernet setting is enabled in the project parameters, this register displays the set value.
892 +②. When the Ethernet setting is not enabled in the engineering parameters, the register displays the Ethernet IP automatically acquired by the HMI.
893 +③. When the HMI is not plugged into the network cable, the register will show 0 whether the engineering parameters are set or not.
894 +④.IP related registers can be read and written (only static IP mode can be written).
646 646  )))|(% style="width:452px" %)Local IP address high byte 1
647 647  |=(% style="width: 160px;" %)HSW10036|(% style="width:452px" %)Local IP address high byte 2
648 648  |=(% style="width: 160px;" %)HSW10037|(% style="width:452px" %)Local IP address high byte 3
... ... @@ -657,9 +657,11 @@
657 657  |=(% style="width: 160px;" %)HSW10046|(% style="width:452px" %)Local gateway address high byte 4
658 658  |=(% style="width: 160px;" %)HSW10047|(% style="width:452px" %)Local port address
659 659  |=(% style="width: 160px;" %)HSW10048|(% rowspan="6" style="width:282px" %)(((
660 -Displays the MAC code of the current network card
909 +Display the MAC code of Ethernet1 NIC
661 661  
662 -(Hexadecimal display)
911 +(hexadecimal display)
912 +
913 +②Read-only mode, not modifiable
663 663  )))|(% style="width:452px" %)Local MAC code high word 1
664 664  |=(% style="width: 160px;" %)HSW10049|(% style="width:452px" %)Local MAC code high word 2
665 665  |=(% style="width: 160px;" %)HSW10050|(% style="width:452px" %)Local MAC code high word 3
... ... @@ -748,11 +748,32 @@
748 748  )))
749 749  |=(% style="width: 160px;" %)HSW11760|(% style="width:282px" %)Screensaver countdown|(% style="width:452px" %)Display the countdown to enter the Screensaver, unit: second.
750 750  |=(% style="width: 160px;" %)HSW11761|(% style="width:282px" %)Screensaver screen number|(% style="width:452px" %)Set the screen number for Screensaver
1002 +|=(% style="width: 160px;" %)(((
1003 +HSW11762
1004 +)))|(% style="width:282px" %)(((
1005 +Dynamic screensaver control address
1006 +)))|(% style="width:452px" %)(((
1007 +HSX11762.0: =0, initialize with project configuration; =1, initialize with special register configuration; HSX11762.1: =0, disable dynamic screensaver; =1, enable dynamic screensaver
1008 +)))
1009 +|=(% style="width: 160px;" %)(((
1010 +HSW11763
1011 +)))|(% style="width:282px" %)(((
1012 +Waiting time to enter the dynamic screensaver
1013 +)))|(% style="width:452px" %)(((
1014 +Waiting time when the screen is not operated, range 1~~720 minutes
1015 +)))
1016 +|=(% style="width: 160px;" %)(((
1017 +HSW11764
1018 +)))|(% style="width:282px" %)(((
1019 +Animated screensaver animation type
1020 +)))|(% style="width:452px" %)(((
1021 +~=0:lattice,=1:shutter,=2:bubble
1022 +)))
751 751  
752 -== **Serial port communication configuration** ==
1024 +== Serial port communication configuration ==
753 753  
754 754  (% class="table-bordered" %)
755 -|=(% style="width: 102px;" %)Port|=(% style="width: 173px;" %)**Function**|=(% style="width: 122px;" %)**Address**|=(% colspan="2" style="width: 506px;" %)**Description**
1027 +|=(% scope="row" style="width: 102px;" %)Port|=(% style="width: 173px;" %)**Function**|=(% style="width: 122px;" %)**Address**|=(% colspan="2" style="width: 506px;" %)**Description**
756 756  |(% colspan="1" rowspan="11" style="width:102px" %)COM1|(% style="width:173px" %)Communication mode|(% style="width:122px" %)HSW10061|(% colspan="2" style="width:506px" %)(((
757 757  * =0: RS232
758 758  * =1: RS485
... ... @@ -782,10 +782,22 @@
782 782  * =1: ODD
783 783  * =2: EVEN
784 784  )))
785 -|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10066|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000
786 -|(% style="width:173px" %)reveive timeout|(% style="width:122px" %)HSW10067|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000
787 -|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10068|(% colspan="2" style="width:506px" %)Unit: times. Range: 0~~100
788 -|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10069|(% colspan="2" style="width:506px" %)Unit: s. Range: 0~~300
1057 +|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10066|(% colspan="2" style="width:506px" %)(((
1058 +* Unit: ms.
1059 +* Range: 0 to 30000
1060 +)))
1061 +|(% style="width:173px" %)reveive timeout|(% style="width:122px" %)HSW10067|(% colspan="2" style="width:506px" %)(((
1062 +* Unit: ms.
1063 +* Range: 0 to 30000
1064 +)))
1065 +|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10068|(% colspan="2" style="width:506px" %)(((
1066 +* Unit: times.
1067 +* Range: 0 to 100
1068 +)))
1069 +|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10069|(% colspan="2" style="width:506px" %)(((
1070 +* Unit: s.
1071 +* Range: 0 to 300
1072 +)))
789 789  |(% style="width:173px" %)HMI station number|(% style="width:122px" %)HSW10070|(% colspan="2" style="width:506px" %)
790 790  |(% style="width:173px" %)PLC station number|(% style="width:122px" %)HSW10071|(% colspan="2" style="width:506px" %)
791 791  |(% colspan="1" rowspan="11" style="width:102px" %)COM1-2|(% style="width:173px" %)Communication mode|(% style="width:122px" %)HSW10094|(% colspan="2" style="width:506px" %)(((
... ... @@ -818,10 +818,22 @@
818 818  * =1: ODD
819 819  * =2: EVEN
820 820  )))
821 -|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10099|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000
822 -|(% style="width:173px" %)receive timeout|(% style="width:122px" %)HSW10100|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000
823 -|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10101|(% colspan="2" style="width:506px" %)Unit: times. Range: 0~~100
824 -|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10102|(% colspan="2" style="width:506px" %)Unit: s. Range: 0~~30
1105 +|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10099|(% colspan="2" style="width:506px" %)(((
1106 +* Unit: ms.
1107 +* Range: 0 to 30000
1108 +)))
1109 +|(% style="width:173px" %)receive timeout|(% style="width:122px" %)HSW10100|(% colspan="2" style="width:506px" %)(((
1110 +* Unit: ms.
1111 +* Range: 0 to 30000
1112 +)))
1113 +|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10101|(% colspan="2" style="width:506px" %)(((
1114 +* Unit: times.
1115 +* Range: 0 to 100
1116 +)))
1117 +|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10102|(% colspan="2" style="width:506px" %)(((
1118 +* Unit: s.
1119 +* Range: 0 to 30
1120 +)))
825 825  |(% style="width:173px" %)HMI station number|(% style="width:122px" %)HSW10103|(% colspan="2" style="width:506px" %)
826 826  |(% style="width:173px" %)PLC station number|(% style="width:122px" %)HSW10104|(% colspan="2" style="width:506px" %)
827 827  |(% colspan="1" rowspan="11" style="width:102px" %)COM1-3|(% style="width:173px" %)Communication mode|(% style="width:122px" %)HSW10120|(% colspan="2" style="width:506px" %)(((
... ... @@ -854,10 +854,22 @@
854 854  * =1: ODD
855 855  * =2: EVEN
856 856  )))
857 -|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10125|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000
858 -|(% style="width:173px" %)receive timeout|(% style="width:122px" %)HSW10126|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000
859 -|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10127|(% colspan="2" style="width:506px" %)Unit: times. Range: 0~~100
860 -|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10128|(% colspan="2" style="width:506px" %)Unit: s. Range: 0~~30
1153 +|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10125|(% colspan="2" style="width:506px" %)(((
1154 +* Unit: ms.
1155 +* Range: 0 to 30000
1156 +)))
1157 +|(% style="width:173px" %)receive timeout|(% style="width:122px" %)HSW10126|(% colspan="2" style="width:506px" %)(((
1158 +* Unit: ms.
1159 +* Range: 0 to 30000
1160 +)))
1161 +|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10127|(% colspan="2" style="width:506px" %)(((
1162 +* Unit: times.
1163 +* Range: 0 to 100
1164 +)))
1165 +|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10128|(% colspan="2" style="width:506px" %)(((
1166 +* Unit: s.
1167 +* Range: 0 to 30
1168 +)))
861 861  |(% style="width:173px" %)HMI station number|(% style="width:122px" %)HSW10129|(% colspan="2" style="width:506px" %)
862 862  |(% style="width:173px" %)PLC station number|(% style="width:122px" %)HSW10130|(% colspan="2" style="width:506px" %)
863 863  |(% colspan="1" rowspan="11" style="width:102px" %)COM2|(% style="width:173px" %)Communication mode|(% style="width:122px" %)HSW10072|(% colspan="2" style="width:506px" %)(((
... ... @@ -888,10 +888,22 @@
888 888  * =1: ODD
889 889  * =2: EVEN
890 890  )))
891 -|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10077|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000
892 -|(% style="width:173px" %)receive timeout|(% style="width:122px" %)HSW10078|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000
893 -|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10079|(% colspan="2" style="width:506px" %)Unit: times. Range: 0~~100
894 -|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10080|(% colspan="2" style="width:506px" %)Unit: s. Range: 0~~30
1199 +|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10077|(% colspan="2" style="width:506px" %)(((
1200 +* Unit: ms.
1201 +* Range: 0 to 30000
1202 +)))
1203 +|(% style="width:173px" %)receive timeout|(% style="width:122px" %)HSW10078|(% colspan="2" style="width:506px" %)(((
1204 +* Unit: ms.
1205 +* Range: 0 to 30000
1206 +)))
1207 +|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10079|(% colspan="2" style="width:506px" %)(((
1208 +* Unit: times.
1209 +* Range: 0 to 100
1210 +)))
1211 +|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10080|(% colspan="2" style="width:506px" %)(((
1212 +* Unit: s.
1213 +* Range: 0 to 30
1214 +)))
895 895  |(% style="width:173px" %)HMI station number|(% style="width:122px" %)HSW10081|(% colspan="2" style="width:506px" %)
896 896  |(% style="width:173px" %)PLC station number|(% style="width:122px" %)HSW10082|(% colspan="2" style="width:506px" %)
897 897  |(% colspan="1" rowspan="11" style="width:102px" %)COM2-2|(% style="width:173px" %)Communication mode|(% style="width:122px" %)HSW10105|(% colspan="2" style="width:506px" %)(((
... ... @@ -922,10 +922,22 @@
922 922  * =1: ODD
923 923  * =2: EVEN
924 924  )))
925 -|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10110|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000
926 -|(% style="width:173px" %)receive timeout|(% style="width:122px" %)HSW10111|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000
927 -|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10112|(% colspan="2" style="width:506px" %)Unit: times. Range: 0~~100
928 -|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10113|(% colspan="2" style="width:506px" %)Unit: s. Range: 0~~30
1245 +|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10110|(% colspan="2" style="width:506px" %)(((
1246 +* Unit: ms.
1247 +* Range: 0 to 30000
1248 +)))
1249 +|(% style="width:173px" %)receive timeout|(% style="width:122px" %)HSW10111|(% colspan="2" style="width:506px" %)(((
1250 +* Unit: ms.
1251 +* Range: 0 to 30000
1252 +)))
1253 +|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10112|(% colspan="2" style="width:506px" %)(((
1254 +* Unit: times.
1255 +* Range: 0 to 100
1256 +)))
1257 +|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10113|(% colspan="2" style="width:506px" %)(((
1258 +* Unit: s.
1259 +* Range: 0 to 30
1260 +)))
929 929  |(% style="width:173px" %)HMI station number|(% style="width:122px" %)HSW10114|(% colspan="2" style="width:506px" %)
930 930  |(% style="width:173px" %)PLC station number|(% style="width:122px" %)HSW10115|(% colspan="2" style="width:506px" %)
931 931  |(% colspan="1" rowspan="11" style="width:102px" %)COM3|(% style="width:173px" %)Communication mode|(% style="width:122px" %)HSW10083|(% colspan="2" style="width:506px" %)(((
... ... @@ -955,29 +955,48 @@
955 955  * =1: ODD
956 956  * =2: EVEN
957 957  )))
958 -|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10088|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000
959 -|(% style="width:173px" %)receive timeout|(% style="width:122px" %)HSW10089|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000
960 -|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10090|(% colspan="2" style="width:506px" %)Unit: times. Range: 0~~100
961 -|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10091|(% colspan="2" style="width:506px" %)Unit: s. Range: 0~~30
1290 +|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10088|(% colspan="2" style="width:506px" %)(((
1291 +* Unit: ms.
1292 +* Range: 0 to 30000
1293 +)))
1294 +|(% style="width:173px" %)receive timeout|(% style="width:122px" %)HSW10089|(% colspan="2" style="width:506px" %)(((
1295 +* Unit: ms.
1296 +* Range: 0 to 30000
1297 +)))
1298 +|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10090|(% colspan="2" style="width:506px" %)(((
1299 +* Unit: times.
1300 +* Range: 0 to 100
1301 +)))
1302 +|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10091|(% colspan="2" style="width:506px" %)(((
1303 +* Unit: s.
1304 +* Range: 0 to 30
1305 +)))
962 962  |(% style="width:173px" %)HMI station number|(% style="width:122px" %)HSW10092|(% colspan="2" style="width:506px" %)
963 963  |(% style="width:173px" %)PLC station number|(% style="width:122px" %)HSW10093|(% colspan="2" style="width:506px" %)
964 964  |(% colspan="1" rowspan="2" style="width:102px" %)CAN port|(% style="width:173px" %)CAN1 baud rate|(% style="width:122px" %)HSW010116|(% style="width:299px" %)(((
965 -Unit: K, the baud rate must be an integer, for example, when the baud rate required is 250000, just enter 250.
1309 +Unit: K, the baud rate must be an integer.
1310 +
1311 +For example, when the baud rate required is 250000, just enter 250.
966 966  )))|(% colspan="1" rowspan="2" style="width:218px" %)**✎Note: **If baud rate has been modified,please wait 5 seconds,then restart the HMI to take effect.
967 -|(% style="width:173px" %)CAN2 baud rate|(% style="width:122px" %)HSW010117|(% style="width:299px" %)Unit: K, the baud rate must be an integer, for example, when the baud rate required is 250000, just enter 250.
1313 +|(% style="width:173px" %)CAN2 baud rate|(% style="width:122px" %)HSW010117|(% style="width:299px" %)(((
1314 +Unit: K, the baud rate must be an integer.
968 968  
969 -== **Ethernet communication configuration** ==
1316 +For example, when the baud rate required is 250000, just enter 250.
1317 +)))
970 970  
1319 +== Ethernet communication configuration ==
1320 +
971 971  (% class="table-bordered" %)
972 -|=(% style="width: 40px;" %)**No.**|=(% style="width: 295px;" %)**Function**|=(% style="width: 220px;" %)**Address**|=(% style="width: 336px;" %)**Description**
1322 +|(% style="width:40px" %)**No.**|(% style="width:295px" %)**Function**|(% style="width:220px" %)**Address**|(% style="width:336px" %)**Description**
973 973  |(% rowspan="7" style="width:40px" %)1|(% colspan="1" rowspan="7" style="width:295px" %)Ethernet parameter configuration for communication number 1 in list. Configure those addresses according to connected device. After configuration, wait for 5 seconds and restart the HMI.|(% style="width:220px" %)HSW11004|(% style="width:336px" %)Device IP address high word 1
974 974  |(% style="width:220px" %)HSW11005|(% style="width:336px" %)Device IP address high word 2
975 975  |(% style="width:220px" %)HSW11006|(% style="width:336px" %)Device IP address high word 3
976 976  |(% style="width:220px" %)HSW11007|(% style="width:336px" %)Device IP address high word 4
977 977  |(% style="width:220px" %)HSW11008|(% style="width:336px" %)Device Port number
978 -|(% style="width:220px" %)HSW11009|=(% style="width: 336px;" %)(((
979 -* =2 TCP
980 -* =3 UDP
1328 +|(% style="width:220px" %)HSW11009|(% style="width:336px" %)(((
1329 +~=2 TCP
1330 +
1331 +~=3 UDP
981 981  )))
982 982  |(% style="width:220px" %)HSW11010|(% style="width:336px" %)Reserved
983 983  |(% rowspan="7" style="width:40px" %)2|(% colspan="1" rowspan="7" style="width:295px" %)Ethernet parameter configuration for communication number 2 in list. Configure those addresses according to connected device. After configuration, wait for 5 seconds and restart the HMI.|(% style="width:220px" %)HSW11011|(% style="width:336px" %)Device IP address high word 1
... ... @@ -985,9 +985,10 @@
985 985  |(% style="width:220px" %)HSW11013|(% style="width:336px" %)Device IP address high word 3
986 986  |(% style="width:220px" %)HSW11014|(% style="width:336px" %)Device IP address high word 4
987 987  |(% style="width:220px" %)HSW11015|(% style="width:336px" %)Device Port number
988 -|(% style="width:220px" %)HSW11016|=(% style="width: 336px;" %)(((
989 -* =2 TCP
990 -* =3 UDP
1339 +|(% style="width:220px" %)HSW11016|(% style="width:336px" %)(((
1340 +~=2 TCP
1341 +
1342 +~=3 UDP
991 991  )))
992 992  |(% style="width:220px" %)HSW11017|(% style="width:336px" %)Reserved
993 993  |(% style="width:40px" %)…|(% style="width:295px" %) |(% style="width:220px" %)…|(% style="width:336px" %)…
... ... @@ -996,16 +996,22 @@
996 996  |(% style="width:220px" %)HSW11223|(% style="width:336px" %)Device IP address high word 3
997 997  |(% style="width:220px" %)HSW11224|(% style="width:336px" %)Device IP address high word 4
998 998  |(% style="width:220px" %)HSW11225|(% style="width:336px" %)Device Port number
999 -|(% style="width:220px" %)HSW11226|=(% style="width: 336px;" %)2 TCP; =3 UDP
1351 +|(% style="width:220px" %)HSW11226|(% style="width:336px" %)(((
1352 +~=2 TCP;
1353 +
1354 +~=3 UDP
1355 +)))
1000 1000  |(% style="width:220px" %)HSW11227|(% style="width:336px" %)Reserved
1001 1001  
1002 -(% class="wikigeneratedid" %)
1358 +(% class="box infomessage" %)
1359 +(((
1003 1003  **✎Note:** The number of Ethernet connections supported by different HMI series varies.
1361 +)))
1004 1004  
1005 -== **Communication control** ==
1363 +== Communication control ==
1006 1006  
1007 1007  (% class="table-bordered" %)
1008 -|(% style="width:135px" %)**Communication No.**|(% style="width:102px" %)**Station No.**|(% style="width:185px" %)**Control bit**|(% style="width:191px" %)**Communication lamp**|(% style="width:271px" %)**Description**
1366 +|=(% style="width: 135px;" %)**Communication No.**|=(% style="width: 102px;" %)**Station No.**|=(% style="width: 185px;" %)**Control bit**|=(% style="width: 191px;" %)**Communication lamp**|=(% style="width: 271px;" %)**Description**
1009 1009  |(% colspan="1" rowspan="16" style="width:135px" %)1|(% style="width:102px" %)0~~15|(% style="width:185px" %)HSX550.0~HSX550.15|(% style="width:191px" %)HSX558.0~HSX558.15|(% rowspan="160" style="width:271px" %)Communication number refers to the number in "Communication Port Configuration". A number provides 256 device station numbers. Each station number corresponds to a communication control bit and a communication indicator bit. Registers HSX550.0 to HSX805.15 are used to control the station numbers from 0 to 127, and registers HSX1150.0 to HSX1405.15 are used to control station numbers 128 to 255.
1010 1010  |(% style="width:102px" %)16~~31|(% style="width:185px" %)HSX551.0~HSX551.15|(% style="width:191px" %)HSX559.0~HSX559.15
1011 1011  |(% style="width:102px" %)32~~47|(% style="width:185px" %)HSX552.0~HSX552.15|(% style="width:191px" %)HSX560.0~HSX560.15