Changes for page 13 HMI Internal Registers
Last modified by Jett on 2025/04/28 16:07
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Hunter1 +XWiki.Bob - Content
-
... ... @@ -25,19 +25,6 @@ 25 25 * The address of the bit address HDX is with a decimal point while word addresses are integers. 26 26 ))) 27 27 28 -= Address ranges table = 29 - 30 -|=(% scope="row" style="width: 218px;" %)Address Type\HMI Series|=(% style="width: 228px;" %)General Series|=(% style="width: 200px;" %)i Series/HMI+ models|=(% style="width: 136px;" %)ie Series|=(% style="width: 232px;" %)ig Series 31 -|=(% style="width: 218px;" %)HDW|(% style="width:228px" %)HDW0-HDW299999|HDW0-HDW299999|HDW0-HDW299999|HDW0-HDW299999 32 -|=(% style="width: 218px;" %)HSW|(% style="width:228px" %)HSW0-HSW14999|HSW0-HSW14999|HSW0-HSW14999|HSW0-HSW14999 33 -|=(% style="width: 218px;" %)HAW|(% style="width:228px" %)HAW0-HAW199999|HAW0-HAW199999|HAW0-HAW199999|HAW0-HAW199999 34 -|=(% style="width: 218px;" %)HUW|(% style="width:228px" %)HUW0-HUW1599|HUW0-HUW1599|HUW0-HUW1599|HUW0-HUW1599 35 -|=(% style="width: 218px;" %)HDX|(% style="width:228px" %)HDX0.0-HDX299999.15|HDX0.0-HDX299999.15|HDX0.0-HDX299999.15|HDX0.0-HDX299999.15 36 -|=(% style="width: 218px;" %)HSX|(% style="width:228px" %)HSX0.0-HSX14999.15|HSX0.0-HSX14999.15|HSX0-HSX14999.15|HSX0.0-HSX14999.15 37 -|=(% style="width: 218px;" %)HAX|(% style="width:228px" %)HAX0.0-HAX199999.15|HAX0.0-HAX199999.15|HAX0.0-HAX199999.15|HAX0.0-HAX199999.15 38 -|=(% style="width: 218px;" %)HUX|(% style="width:228px" %)HUX0.0-HUX1599.15|HUX0.0-HUX1599.15|HUX0.0-HUX1599.15|HUX0.0-HUX1599.15 39 -|=(% style="width: 218px;" %)RPW|(% style="width:228px" %) |RPW000000-RPW990450|RPW000000-RPW990450|RPW000000-RPW990450 40 - 41 41 = **Data storage area (HDW/HDX)** = 42 42 43 43 It is used to save the temporary data of project. ... ... @@ -254,8 +254,8 @@ 254 254 * =2: HSX521.1=1, delete all trend graph. 255 255 * =4: HSX521.2=1, delete all alarms. 256 256 * =16: HSX521.4=1, delete history XY plot. 257 -* =32: HSX521.5=1, delete data records in SD card or USBflash disk;(Please make a setting which is saved toUSBflash disk or SD card in project setting).258 -* =64: HSX521.6=1, delete alarms records in SD card or USBflash disk; (Please make a setting which is saved toUSBflash disk or SD card in project setting).244 +* =32: HSX521.5=1, delete data records in SD card or flash dish;(Please make a setting which is saved to flash disk or SD card in project setting). 245 +* =64: HSX521.6=1, delete alarms records in SD card or flash dish; (Please make a setting which is saved to flash disk or SD card in project setting). 259 259 ))) 260 260 |=(% style="width: 160px;" %)HSW522|(% style="width:282px" %)Copy and paste the alarm/data files in flash to the USB flash disk|(% style="width:452px" %)((( 261 261 * =0: No operation ... ... @@ -498,8 +498,6 @@ 498 498 * =0, Default value 499 499 * =1, Release the alarm generated before the last power-down when starting up 500 500 ))) 501 -|=(% style="width: 160px;" %)HSW1200|(% colspan="1" rowspan="2" style="width:282px" %)TSAP settings for HMI in the Siemens LOGO! 8 protocol(ig series or HMI V2.0)|(% style="width:452px" %)HMI local TSAP, which corresponds to the remote TSAP of PLC 502 -|=(% style="width: 160px;" %)HSW1201|(% style="width:452px" %)HMI remote TSAP, which corresponds to the local TSAP of PLC 503 503 |=(% style="width: 160px;" %)HSW1450|(% style="width:282px" %)Enable objects level password function|(% style="width:452px" %)((( 504 504 * =0, Disable 505 505 * =1, Enable ... ... @@ -606,9 +606,6 @@ 606 606 * =0: Server connection exception 607 607 * =1: Server connection is OK 608 608 ))) 609 -|=(% style="width: 160px;" %)HSW1740|(% style="width:282px" %)Wi-fi signal strength|(% style="width:452px" %)((( 610 -Display the value of Wi-fi signal signal strength, ranges from 0~~100 (Signal strength is automatically obtained only once when HMI is powered on, and it will not be automatically updated. It needs to be used with the HSW1890) 611 -))) 612 612 |=(% style="width: 160px;" %)HSW1741|(% colspan="1" rowspan="12" style="width:282px" %)Related IP register in 4Gnetwork status (It is valid when HMI is connected to 4G)|(% style="width:452px" %)Local IP address high byte 1 613 613 |=(% style="width: 160px;" %)HSW1742|(% style="width:452px" %)Local IP address high byte 2 614 614 |=(% style="width: 160px;" %)HSW1743|(% style="width:452px" %)Local IP address high byte 3 ... ... @@ -808,8 +808,6 @@ 808 808 |=(% style="width: 160px;" %)HSW1853|(% style="width:282px" %)File format for exporting data records to USB flash drive or SD card|(% style="width:452px" %)((( 809 809 * =0: db database 810 810 * =1: CSV 811 - 812 -(Only valid for script function DbToCsvFile) 813 813 ))) 814 814 |=(% style="width: 160px;" %)HSW1854|(% style="width:282px" %)High and low word conversion type|(% style="width:452px" %)((( 815 815 * =0: use the old high-low word conversion (default) ... ... @@ -836,7 +836,7 @@ 836 836 * =1: priority WLAN 837 837 * =2: priority 4G 838 838 ))) 839 -|=(% style="width: 160px;" %)HSW1866|(% style="width:282px" %)Delete the L ua extension module file|(% style="width:452px" %)(((819 +|=(% style="width: 160px;" %)HSW1866|(% style="width:282px" %)Delete the LUa extension module file|(% style="width:452px" %)((( 840 840 * =0: delete; 841 841 * = Others: do not delete 842 842 ))) ... ... @@ -853,13 +853,6 @@ 853 853 * = 1: no 854 854 ))) 855 855 |=(% style="width: 160px;" %)((( 856 -HSW1869 857 -)))|(% style="width:282px" %)((( 858 -Dynamic screensaver countdown 859 -)))|(% style="width:452px" %)((( 860 -Countdown to enter dynamic screensaver effect, unit (S) 861 -))) 862 -|=(% style="width: 160px;" %)((( 863 863 HSW1870 864 864 )))|(% style="width:282px" %)((( 865 865 Display or set the dynamic or static IP mode of Ethernet1 ... ... @@ -905,15 +905,6 @@ 905 905 |=(% style="width: 160px;" %)((( 906 906 HSW1879 907 907 )))|(% style="width:452px" %)Ethernet1 Local DNS2 address high byte 4 908 -|=(% style="width: 160px;" %)HSW1890|(% colspan="1" style="width:282px" %)Enable refresh current network signal|(% style="width:452px" %)((( 909 -* =1: Refresh the network signal once after triggered (This register will be automatically reset after triggered, only update the signal value once after per 15 seconds, not able to update twice in the short interval) 910 -* =Others: not refresh 911 -))) 912 -|=(% style="width: 160px;" %)HSW1891|(% colspan="1" style="width:282px" %)Enable clear cache for screen data |(% style="width:452px" %)((( 913 -* =1, not clear screen cache when switch language 914 -* =2, trigger clear cache of all screens for once time 915 -* =3, always clear cache of all screen data 916 -))) 917 917 |=(% style="width: 160px;" %)HSW10000~~19999|(% style="width:282px" %)Power-down storage area|(% style="width:452px" %)After restart, the data remains 918 918 |=(% style="width: 160px;" %)HSW10035|(% rowspan="13" style="width:282px" %)((( 919 919 Note: Valid when Ethernet1 of HMI is plugged into the network cable. ... ... @@ -946,7 +946,7 @@ 946 946 |=(% style="width: 160px;" %)HSW10051|(% style="width:452px" %)Local MAC code high word 4 947 947 |=(% style="width: 160px;" %)HSW10052|(% style="width:452px" %)Local MAC code high word 5 948 948 |=(% style="width: 160px;" %)HSW10053|(% style="width:452px" %)Local MAC code high word 6 949 -|=(% style="width: 160px;" %)HSW10118|(% colspan="1" rowspan="2" style="width:282px" %)TSAP settings for HMI in the Siemens LOGO! 8 protocol|(% style="width:452px" %)HMI local TSAP, which corresponds to the remote TSAP of PLC913 +|=(% style="width: 160px;" %)HSW10118|(% colspan="1" rowspan="2" style="width:282px" %)TSAP settings for HMI in the Siemens logo! 8 protocol|(% style="width:452px" %)HMI local TSAP, which corresponds to the remote TSAP of PLC 950 950 |=(% style="width: 160px;" %)HSW10119|(% style="width:452px" %)HMI remote TSAP, which corresponds to the local TSAP of PLC 951 951 |=(% style="width: 160px;" %)HSW10461~~10493|(% style="width:282px" %)Remote access password|(% style="width:452px" %)8-character remote access password 952 952 |=(% style="width: 160px;" %)HSW10494~~10558|(% style="width:282px" %)Machine ID (Read only)|(% style="width:452px" %)Machine ID for remote access (read only 64-bit) ... ... @@ -1028,34 +1028,7 @@ 1028 1028 ))) 1029 1029 |=(% style="width: 160px;" %)HSW11760|(% style="width:282px" %)Screensaver countdown|(% style="width:452px" %)Display the countdown to enter the Screensaver, unit: second. 1030 1030 |=(% style="width: 160px;" %)HSW11761|(% style="width:282px" %)Screensaver screen number|(% style="width:452px" %)Set the screen number for Screensaver 1031 -|=(% style="width: 160px;" %)((( 1032 -HSW11762 1033 -)))|(% style="width:282px" %)((( 1034 -Dynamic screensaver control address 1035 -)))|(% style="width:452px" %)((( 1036 -HSX11762.0=0, initialize with project configuration; 1037 1037 1038 -HSX11762.0=1, initialize with special register configuration; 1039 - 1040 -HSX11762.1=0, disable dynamic screensaver; 1041 - 1042 -HSX11762.1=1, enable dynamic screensaver 1043 -))) 1044 -|=(% style="width: 160px;" %)((( 1045 -HSW11763 1046 -)))|(% style="width:282px" %)((( 1047 -Waiting time to enter the dynamic screensaver 1048 -)))|(% style="width:452px" %)((( 1049 -Waiting time when the screen is not operated, range 1~~720 minutes 1050 -))) 1051 -|=(% style="width: 160px;" %)((( 1052 -HSW11764 1053 -)))|(% style="width:282px" %)((( 1054 -Animated screensaver animation type 1055 -)))|(% style="width:452px" %)((( 1056 -~=0: Raster,=1: Blinds,=2: Bubble 1057 -))) 1058 - 1059 1059 == Serial port communication configuration == 1060 1060 1061 1061 (% class="table-bordered" %)