Changes for page 13 HMI Internal Registers

Last modified by Jett on 2025/04/28 16:07

From version 20.1
edited by Hunter
on 2023/02/18 14:19
Change comment: There is no comment for this version
To version 25.1
edited by Hunter
on 2023/03/01 11:16
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -27,7 +27,8 @@
27 27  
28 28  = Address ranges table =
29 29  
30 -|=(% scope="row" style="width: 218px;" %)Address Type\HMI Series|=(% style="width: 228px;" %)General Series|=(% style="width: 200px;" %)i Series/HMI+ models|=(% style="width: 136px;" %)ie Series|=(% style="width: 232px;" %)ig Series
30 +(% cellpadding="10" %)
31 +|=(% scope="row" style="width: 218px;" %)Address Type\HMI Series|=(% style="width: 228px;" %)General Series|=(% style="width: 200px;" %)i /HMI+ Series|=(% style="width: 136px;" %)ie Series|=(% style="width: 232px;" %)ig Series
31 31  |=(% style="width: 218px;" %)HDW|(% style="width:228px" %)HDW0-HDW299999|HDW0-HDW299999|HDW0-HDW299999|HDW0-HDW299999
32 32  |=(% style="width: 218px;" %)HSW|(% style="width:228px" %)HSW0-HSW14999|HSW0-HSW14999|HSW0-HSW14999|HSW0-HSW14999
33 33  |=(% style="width: 218px;" %)HAW|(% style="width:228px" %)HAW0-HAW199999|HAW0-HAW199999|HAW0-HAW199999|HAW0-HAW199999
... ... @@ -73,8 +73,8 @@
73 73  
74 74  It is used for system special registers (reserved by system).
75 75  
76 -1. Access as word, and serial number range is from HUW0 to HUW199999.
77 -1. Access as bit, and serial number range is from HUX0.0 to HUX199999.15.
77 +1. Access as word, and serial number range is from HUW0 to HUW1599.
78 +1. Access as bit, and serial number range is from HUX0.0 to HUX1599.15.
78 78  
79 79  **✎Note:**
80 80  
... ... @@ -917,10 +917,10 @@
917 917  |=(% style="width: 160px;" %)HSW10000~~19999|(% style="width:282px" %)Power-down storage area|(% style="width:452px" %)After restart, the data remains
918 918  |=(% style="width: 160px;" %)HSW10035|(% rowspan="13" style="width:282px" %)(((
919 919  Note: Valid when Ethernet1 of HMI is plugged into the network cable.
920 -①When the Ethernet setting is enabled in the project parameters, this register displays the set value.
921 -②. When the Ethernet setting is not enabled in the engineering parameters, the register displays the Ethernet IP automatically acquired by the HMI.
922 -③. When the HMI is not plugged into the network cable, the register will show 0 whether the engineering parameters are set or not.
923 -④.IP related registers can be read and written (only static IP mode can be written).
921 +① When the Ethernet setting is enabled in the project parameters, this register displays the set value.
922 +② When the Ethernet setting is not enabled in the engineering parameters, the register displays the Ethernet IP automatically acquired by the HMI.
923 +③ When the HMI is not plugged into the network cable, the register will show 0 whether the engineering parameters are set or not.
924 +④ IP related registers can be read and written (only static IP mode can be written).
924 924  )))|(% style="width:452px" %)Local IP address high byte 1
925 925  |=(% style="width: 160px;" %)HSW10036|(% style="width:452px" %)Local IP address high byte 2
926 926  |=(% style="width: 160px;" %)HSW10037|(% style="width:452px" %)Local IP address high byte 3