Changes for page 13 HMI Internal Registers
Last modified by Jett on 2025/04/28 16:07
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -25,20 +25,6 @@ 25 25 * The address of the bit address HDX is with a decimal point while word addresses are integers. 26 26 ))) 27 27 28 -= Address ranges table = 29 - 30 -(% cellpadding="10" %) 31 -|=(% scope="row" style="width: 218px;" %)Address Type\HMI Series|=(% style="width: 228px;" %)General Series|=(% style="width: 200px;" %)i Series/HMI+ models|=(% style="width: 136px;" %)ie Series|=(% style="width: 232px;" %)ig Series 32 -|=(% style="width: 218px;" %)HDW|(% style="width:228px" %)HDW0-HDW299999|HDW0-HDW299999|HDW0-HDW299999|HDW0-HDW299999 33 -|=(% style="width: 218px;" %)HSW|(% style="width:228px" %)HSW0-HSW14999|HSW0-HSW14999|HSW0-HSW14999|HSW0-HSW14999 34 -|=(% style="width: 218px;" %)HAW|(% style="width:228px" %)HAW0-HAW199999|HAW0-HAW199999|HAW0-HAW199999|HAW0-HAW199999 35 -|=(% style="width: 218px;" %)HUW|(% style="width:228px" %)HUW0-HUW1599|HUW0-HUW1599|HUW0-HUW1599|HUW0-HUW1599 36 -|=(% style="width: 218px;" %)HDX|(% style="width:228px" %)HDX0.0-HDX299999.15|HDX0.0-HDX299999.15|HDX0.0-HDX299999.15|HDX0.0-HDX299999.15 37 -|=(% style="width: 218px;" %)HSX|(% style="width:228px" %)HSX0.0-HSX14999.15|HSX0.0-HSX14999.15|HSX0-HSX14999.15|HSX0.0-HSX14999.15 38 -|=(% style="width: 218px;" %)HAX|(% style="width:228px" %)HAX0.0-HAX199999.15|HAX0.0-HAX199999.15|HAX0.0-HAX199999.15|HAX0.0-HAX199999.15 39 -|=(% style="width: 218px;" %)HUX|(% style="width:228px" %)HUX0.0-HUX1599.15|HUX0.0-HUX1599.15|HUX0.0-HUX1599.15|HUX0.0-HUX1599.15 40 -|=(% style="width: 218px;" %)RPW|(% style="width:228px" %) |RPW000000-RPW990450|RPW000000-RPW990450|RPW000000-RPW990450 41 - 42 42 = **Data storage area (HDW/HDX)** = 43 43 44 44 It is used to save the temporary data of project. ... ... @@ -607,9 +607,6 @@ 607 607 * =0: Server connection exception 608 608 * =1: Server connection is OK 609 609 ))) 610 -|=(% style="width: 160px;" %)HSW1740|(% style="width:282px" %)Wi-fi signal strength|(% style="width:452px" %)((( 611 -Display the value of Wi-fi signal signal strength, ranges from 0~~100 (Signal strength is automatically obtained only once when HMI is powered on, and it will not be automatically updated. It needs to be used with the HSW1890) 612 -))) 613 613 |=(% style="width: 160px;" %)HSW1741|(% colspan="1" rowspan="12" style="width:282px" %)Related IP register in 4Gnetwork status (It is valid when HMI is connected to 4G)|(% style="width:452px" %)Local IP address high byte 1 614 614 |=(% style="width: 160px;" %)HSW1742|(% style="width:452px" %)Local IP address high byte 2 615 615 |=(% style="width: 160px;" %)HSW1743|(% style="width:452px" %)Local IP address high byte 3 ... ... @@ -809,8 +809,6 @@ 809 809 |=(% style="width: 160px;" %)HSW1853|(% style="width:282px" %)File format for exporting data records to USB flash drive or SD card|(% style="width:452px" %)((( 810 810 * =0: db database 811 811 * =1: CSV 812 - 813 -(Only valid for script function DbToCsvFile) 814 814 ))) 815 815 |=(% style="width: 160px;" %)HSW1854|(% style="width:282px" %)High and low word conversion type|(% style="width:452px" %)((( 816 816 * =0: use the old high-low word conversion (default) ... ... @@ -837,7 +837,7 @@ 837 837 * =1: priority WLAN 838 838 * =2: priority 4G 839 839 ))) 840 -|=(% style="width: 160px;" %)HSW1866|(% style="width:282px" %)Delete the L ua extension module file|(% style="width:452px" %)(((821 +|=(% style="width: 160px;" %)HSW1866|(% style="width:282px" %)Delete the LUa extension module file|(% style="width:452px" %)((( 841 841 * =0: delete; 842 842 * = Others: do not delete 843 843 ))) ... ... @@ -906,15 +906,6 @@ 906 906 |=(% style="width: 160px;" %)((( 907 907 HSW1879 908 908 )))|(% style="width:452px" %)Ethernet1 Local DNS2 address high byte 4 909 -|=(% style="width: 160px;" %)HSW1890|(% colspan="1" style="width:282px" %)Enable refresh current network signal|(% style="width:452px" %)((( 910 -* =1: Refresh the network signal once after triggered (This register will be automatically reset after triggered, only update the signal value once after per 15 seconds, not able to update twice in the short interval) 911 -* =Others: not refresh 912 -))) 913 -|=(% style="width: 160px;" %)HSW1891|(% colspan="1" style="width:282px" %)Enable clear cache for screen data |(% style="width:452px" %)((( 914 -* =1, not clear screen cache when switch language 915 -* =2, trigger clear cache of all screens for once time 916 -* =3, always clear cache of all screen data 917 -))) 918 918 |=(% style="width: 160px;" %)HSW10000~~19999|(% style="width:282px" %)Power-down storage area|(% style="width:452px" %)After restart, the data remains 919 919 |=(% style="width: 160px;" %)HSW10035|(% rowspan="13" style="width:282px" %)((( 920 920 Note: Valid when Ethernet1 of HMI is plugged into the network cable.