Changes for page 13 HMI Internal Registers
Last modified by Jett on 2025/04/28 16:07
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -28,7 +28,7 @@ 28 28 = Address ranges table = 29 29 30 30 (% cellpadding="10" %) 31 -|=(% scope="row" style="width: 218px;" %)Address Type\HMI Series|=(% style="width: 228px;" %)General Series|=(% style="width: 200px;" %)i Series/HMI+models|=(% style="width: 136px;" %)ie Series|=(% style="width: 232px;" %)ig Series31 +|=(% scope="row" style="width: 218px;" %)Address Type\HMI Series|=(% style="width: 228px;" %)General Series|=(% style="width: 200px;" %)i /HMI+ Series|=(% style="width: 136px;" %)ie Series|=(% style="width: 232px;" %)ig Series 32 32 |=(% style="width: 218px;" %)HDW|(% style="width:228px" %)HDW0-HDW299999|HDW0-HDW299999|HDW0-HDW299999|HDW0-HDW299999 33 33 |=(% style="width: 218px;" %)HSW|(% style="width:228px" %)HSW0-HSW14999|HSW0-HSW14999|HSW0-HSW14999|HSW0-HSW14999 34 34 |=(% style="width: 218px;" %)HAW|(% style="width:228px" %)HAW0-HAW199999|HAW0-HAW199999|HAW0-HAW199999|HAW0-HAW199999 ... ... @@ -918,10 +918,10 @@ 918 918 |=(% style="width: 160px;" %)HSW10000~~19999|(% style="width:282px" %)Power-down storage area|(% style="width:452px" %)After restart, the data remains 919 919 |=(% style="width: 160px;" %)HSW10035|(% rowspan="13" style="width:282px" %)((( 920 920 Note: Valid when Ethernet1 of HMI is plugged into the network cable. 921 -① 、When the Ethernet setting is enabled in the project parameters, this register displays the set value.922 -② .When the Ethernet setting is not enabled in the engineering parameters, the register displays the Ethernet IP automatically acquired by the HMI.923 -③ .When the HMI is not plugged into the network cable, the register will show 0 whether the engineering parameters are set or not.924 -④ .IP related registers can be read and written (only static IP mode can be written).921 +① When the Ethernet setting is enabled in the project parameters, this register displays the set value. 922 +② When the Ethernet setting is not enabled in the engineering parameters, the register displays the Ethernet IP automatically acquired by the HMI. 923 +③ When the HMI is not plugged into the network cable, the register will show 0 whether the engineering parameters are set or not. 924 +④ IP related registers can be read and written (only static IP mode can be written). 925 925 )))|(% style="width:452px" %)Local IP address high byte 1 926 926 |=(% style="width: 160px;" %)HSW10036|(% style="width:452px" %)Local IP address high byte 2 927 927 |=(% style="width: 160px;" %)HSW10037|(% style="width:452px" %)Local IP address high byte 3