... ... @@ -28,7 +28,7 @@
28 28  = Address ranges table =
29 29  
30 30  (% cellpadding="10" %)
31 -|=(% scope="row" style="width: 218px;" %)Address Type\HMI Series|=(% style="width: 228px;" %)General Series|=(% style="width: 200px;" %)i Series/HMI+ models|=(% style="width: 136px;" %)ie Series|=(% style="width: 232px;" %)ig Series
31 +|=(% scope="row" style="width: 218px;" %)Address Type\HMI Series|=(% style="width: 228px;" %)General Series|=(% style="width: 200px;" %)i /HMI+ Series|=(% style="width: 136px;" %)ie Series|=(% style="width: 232px;" %)ig Series
32 32  |=(% style="width: 218px;" %)HDW|(% style="width:228px" %)HDW0-HDW299999|HDW0-HDW299999|HDW0-HDW299999|HDW0-HDW299999
33 33  |=(% style="width: 218px;" %)HSW|(% style="width:228px" %)HSW0-HSW14999|HSW0-HSW14999|HSW0-HSW14999|HSW0-HSW14999
34 34  |=(% style="width: 218px;" %)HAW|(% style="width:228px" %)HAW0-HAW199999|HAW0-HAW199999|HAW0-HAW199999|HAW0-HAW199999
... ... @@ -918,10 +918,10 @@
918 918  |=(% style="width: 160px;" %)HSW10000~~19999|(% style="width:282px" %)Power-down storage area|(% style="width:452px" %)After restart, the data remains
919 919  |=(% style="width: 160px;" %)HSW10035|(% rowspan="13" style="width:282px" %)(((
920 920  Note: Valid when Ethernet1 of HMI is plugged into the network cable.
921 -①When the Ethernet setting is enabled in the project parameters, this register displays the set value.
922 -②. When the Ethernet setting is not enabled in the engineering parameters, the register displays the Ethernet IP automatically acquired by the HMI.
923 -③. When the HMI is not plugged into the network cable, the register will show 0 whether the engineering parameters are set or not.
924 -④.IP related registers can be read and written (only static IP mode can be written).
921 +① When the Ethernet setting is enabled in the project parameters, this register displays the set value.
922 +② When the Ethernet setting is not enabled in the engineering parameters, the register displays the Ethernet IP automatically acquired by the HMI.
923 +③ When the HMI is not plugged into the network cable, the register will show 0 whether the engineering parameters are set or not.
924 +④ IP related registers can be read and written (only static IP mode can be written).
925 925  )))|(% style="width:452px" %)Local IP address high byte 1
926 926  |=(% style="width: 160px;" %)HSW10036|(% style="width:452px" %)Local IP address high byte 2
927 927  |=(% style="width: 160px;" %)HSW10037|(% style="width:452px" %)Local IP address high byte 3