Changes for page 13 HMI Internal Registers

Last modified by Jett on 2025/04/28 16:07

From version 27.1
edited by Hunter
on 2023/08/03 15:02
Change comment: Replaced user [xwiki:XWiki.hunter123] in fields [author, contentAuthor] to user [xwiki:XWiki.Hunter]
To version 32.1
edited by Mora Zhou
on 2023/11/21 16:20
Change comment: There is no comment for this version

Summary

Details

Page properties
Title
... ... @@ -1,1 +1,1 @@
1 -12 HMI internal registers
1 +13.HMI Internal Registers
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.Hunter
1 +XWiki.Mora
Content
... ... @@ -27,17 +27,8 @@
27 27  
28 28  = Address ranges table =
29 29  
30 -(% cellpadding="10" %)
31 -|=(% scope="row" style="width: 218px;" %)Address Type\HMI Series|=(% style="width: 228px;" %)General Series|=(% style="width: 200px;" %)i /HMI+ Series|=(% style="width: 136px;" %)ie Series|=(% style="width: 232px;" %)ig Series
32 -|=(% style="width: 218px;" %)HDW|(% style="width:228px" %)HDW0-HDW299999|HDW0-HDW299999|HDW0-HDW299999|HDW0-HDW299999
33 -|=(% style="width: 218px;" %)HSW|(% style="width:228px" %)HSW0-HSW14999|HSW0-HSW14999|HSW0-HSW14999|HSW0-HSW14999
34 -|=(% style="width: 218px;" %)HAW|(% style="width:228px" %)HAW0-HAW199999|HAW0-HAW199999|HAW0-HAW199999|HAW0-HAW199999
35 -|=(% style="width: 218px;" %)HUW|(% style="width:228px" %)HUW0-HUW1599|HUW0-HUW1599|HUW0-HUW1599|HUW0-HUW1599
36 -|=(% style="width: 218px;" %)HDX|(% style="width:228px" %)HDX0.0-HDX299999.15|HDX0.0-HDX299999.15|HDX0.0-HDX299999.15|HDX0.0-HDX299999.15
37 -|=(% style="width: 218px;" %)HSX|(% style="width:228px" %)HSX0.0-HSX14999.15|HSX0.0-HSX14999.15|HSX0-HSX14999.15|HSX0.0-HSX14999.15
38 -|=(% style="width: 218px;" %)HAX|(% style="width:228px" %)HAX0.0-HAX199999.15|HAX0.0-HAX199999.15|HAX0.0-HAX199999.15|HAX0.0-HAX199999.15
39 -|=(% style="width: 218px;" %)HUX|(% style="width:228px" %)HUX0.0-HUX1599.15|HUX0.0-HUX1599.15|HUX0.0-HUX1599.15|HUX0.0-HUX1599.15
40 -|=(% style="width: 218px;" %)RPW|(% style="width:228px" %) |RPW000000-RPW990450|RPW000000-RPW990450|RPW000000-RPW990450
30 +(% style="text-align:center" %)
31 +[[image:6.png]]
41 41  
42 42  = **Data storage area (HDW/HDX)** =
43 43  
... ... @@ -65,10 +65,13 @@
65 65  
66 66  It is system recipe data power-off save register. The range is from RPW000000 to RPW990450.
67 67  
59 +(% class="box infomessage" %)
60 +(((
68 68  **✎Note:**
69 69  
70 70  * RPW is power-down retention. The register of this type is able to save the data before the power-down.
71 71  * To avoid possible device failure, do not immediately power off and reboot when configuring the power-down save addre
65 +)))
72 72  
73 73  = **Single user data area (HUW/HUX)** =
74 74  
... ... @@ -77,9 +77,12 @@
77 77  1. Access as word, and serial number range is from HUW0 to HUW1599.
78 78  1. Access as bit, and serial number range is from HUX0.0 to HUX1599.15.
79 79  
74 +(% class="box infomessage" %)
75 +(((
80 80  **✎Note:**
81 81  
82 82  * HUW/HUX is a system special register, so please check the system special register list during use. Please use the address specified in the table and do not use the address which is not mentioned in the table.
79 +)))
83 83  
84 84  (% class="table-bordered" %)
85 85  |=**Special register address**|=**Description**|=**Function**
... ... @@ -149,8 +149,8 @@
149 149  (% class="table-bordered" style="width:1024px" %)
150 150  |=(% scope="row" style="width: 160px;" %)**Address**|=(% style="width: 282px;" %)**Function**|=(% style="width: 452px;" %)**Description**
151 151  |=(% style="width: 160px;" %)HSW0|(% style="width:282px" %)Language switch|(% style="width:452px" %)Multiple language could be set in the project, HMI support maximum 8 languages. (Power-down save supported)
152 -|=(% style="width: 160px;" %)HSW1|(% style="width:282px" %)Beep frequency|(% style="width:452px" %)Frequency range: 0~~4000
153 -|=(% style="width: 160px;" %)HSW2|(% style="width:282px" %)Beep volume|(% style="width:452px" %)Volume range: 0~~80
149 +|=(% style="width: 160px;" %)HSW1|(% style="width:282px" %)Beep frequency (Only valid in HMI V1.0 System)|(% style="width:452px" %)Frequency range: 0~~4000
150 +|=(% style="width: 160px;" %)HSW2|(% style="width:282px" %)Beep volume (Only valid in HMI V1.0 System)|(% style="width:452px" %)Volume range: 0~~80
154 154  |=(% style="width: 160px;" %)HSW3|(% style="width:282px" %)Beep time|(% style="width:452px" %)Unit: ms
155 155  |=(% style="width: 160px;" %)HSW4|(% style="width:282px" %)Beep whether enable or not|(% style="width:452px" %)(((
156 156  * =0: Enable.
... ... @@ -164,7 +164,7 @@
164 164  )))
165 165  |=(% style="width: 160px;" %)HSW6~~HSW7|(% style="width:282px" %)Number of alarms|(% style="width:452px" %)The number of alarm (it also includes the records of alarm confirmed)
166 166  |=(% style="width: 160px;" %)HSW8|(% style="width:282px" %)Number of unconfirmed history alarm|(% style="width:452px" %)The number of unconfirmed history alarm
167 -|=(% style="width: 160px;" %)HSW9|(% style="width:282px" %)Time out tip|(% style="width:452px" %)(((
164 +|=(% style="width: 160px;" %)HSW9|(% style="width:282px" %)Time out prompt|(% style="width:452px" %)(((
168 168  * =0: Enable
169 169  * =1: Disable
170 170  )))
... ... @@ -189,6 +189,7 @@
189 189  * =5: Friday.
190 190  * =6: Saturday.
191 191  )))
189 +|=(% style="width: 160px;" %)HSW39|(% style="width:282px" %)Beep type(Only valid in HMI V2.0 System)|(% style="width:452px" %)Type range: 1-5, Default is 1.
192 192  |=(% style="width: 160px;" %)HSW134|(% style="width:282px" %)(((
193 193  Whether the Script is read through
194 194  
... ... @@ -464,7 +464,7 @@
464 464  Address mapping polling cycle, effective range: 40~~1000ms, default: 300ms.
465 465  
466 466  * When the set value is greater than 1000, the value is 1000.
467 -* When the set value is greater than 1000, it changes to the default value 300
465 +* When the set value is lower than 40, it changes to the default value 300
468 468  )))
469 469  |=(% style="width: 160px;" %)HSW1087|(% style="width:282px" %)Control write interval in address mapping|(% style="width:452px" %)(((
470 470  After reading data to the device for N times, Perform an address mapping write operation. N is the interval value. The effective range: 0~~5, and default is 2.
... ... @@ -1015,6 +1015,7 @@
1015 1015  * =0: LAN or the external network both OK
1016 1016  * =1: Only LAN access
1017 1017  * =2: Only external network can access
1016 +* =3: Close the functions
1018 1018  )))
1019 1019  |=(% style="width: 160px;" %)HSW11757|(% style="width:282px" %)Enable the valid date of the dynamic installment password|(% style="width:452px" %)(((
1020 1020  * =0: Disabled
6.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Mora
Size
... ... @@ -1,0 +1,1 @@
1 +20.1 KB
Content