... ... @@ -164,7 +164,7 @@
164 164  )))
165 165  |=(% style="width: 160px;" %)HSW6~~HSW7|(% style="width:282px" %)Number of alarms|(% style="width:452px" %)The number of alarm (it also includes the records of alarm confirmed)
166 166  |=(% style="width: 160px;" %)HSW8|(% style="width:282px" %)Number of unconfirmed history alarm|(% style="width:452px" %)The number of unconfirmed history alarm
167 -|=(% style="width: 160px;" %)HSW9|(% style="width:282px" %)Time out prompt|(% style="width:452px" %)(((
167 +|=(% style="width: 160px;" %)HSW9|(% style="width:282px" %)Time out tip|(% style="width:452px" %)(((
168 168  * =0: Enable
169 169  * =1: Disable
170 170  )))
... ... @@ -464,7 +464,7 @@
464 464  Address mapping polling cycle, effective range: 40~~1000ms, default: 300ms.
465 465  
466 466  * When the set value is greater than 1000, the value is 1000.
467 -* When the set value is lower than 40, it changes to the default value 300
467 +* When the set value is greater than 1000, it changes to the default value 300
468 468  )))
469 469  |=(% style="width: 160px;" %)HSW1087|(% style="width:282px" %)Control write interval in address mapping|(% style="width:452px" %)(((
470 470  After reading data to the device for N times, Perform an address mapping write operation. N is the interval value. The effective range: 0~~5, and default is 2.
... ... @@ -918,10 +918,10 @@
918 918  |=(% style="width: 160px;" %)HSW10000~~19999|(% style="width:282px" %)Power-down storage area|(% style="width:452px" %)After restart, the data remains
919 919  |=(% style="width: 160px;" %)HSW10035|(% rowspan="13" style="width:282px" %)(((
920 920  Note: Valid when Ethernet1 of HMI is plugged into the network cable.
921 -① When the Ethernet setting is enabled in the project parameters, this register displays the set value.
922 -② When the Ethernet setting is not enabled in the engineering parameters, the register displays the Ethernet IP automatically acquired by the HMI.
923 -③ When the HMI is not plugged into the network cable, the register will show 0 whether the engineering parameters are set or not.
924 -④ IP related registers can be read and written (only static IP mode can be written).
921 +①When the Ethernet setting is enabled in the project parameters, this register displays the set value.
922 +②. When the Ethernet setting is not enabled in the engineering parameters, the register displays the Ethernet IP automatically acquired by the HMI.
923 +③. When the HMI is not plugged into the network cable, the register will show 0 whether the engineering parameters are set or not.
924 +④.IP related registers can be read and written (only static IP mode can be written).
925 925  )))|(% style="width:452px" %)Local IP address high byte 1
926 926  |=(% style="width: 160px;" %)HSW10036|(% style="width:452px" %)Local IP address high byte 2
927 927  |=(% style="width: 160px;" %)HSW10037|(% style="width:452px" %)Local IP address high byte 3