Changes for page 13 HMI Internal Registers
Last modified by Jett on 2025/04/28 16:07
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -164,7 +164,7 @@ 164 164 ))) 165 165 |=(% style="width: 160px;" %)HSW6~~HSW7|(% style="width:282px" %)Number of alarms|(% style="width:452px" %)The number of alarm (it also includes the records of alarm confirmed) 166 166 |=(% style="width: 160px;" %)HSW8|(% style="width:282px" %)Number of unconfirmed history alarm|(% style="width:452px" %)The number of unconfirmed history alarm 167 -|=(% style="width: 160px;" %)HSW9|(% style="width:282px" %)Time out prompt|(% style="width:452px" %)(((167 +|=(% style="width: 160px;" %)HSW9|(% style="width:282px" %)Time out tip|(% style="width:452px" %)((( 168 168 * =0: Enable 169 169 * =1: Disable 170 170 ))) ... ... @@ -464,7 +464,7 @@ 464 464 Address mapping polling cycle, effective range: 40~~1000ms, default: 300ms. 465 465 466 466 * When the set value is greater than 1000, the value is 1000. 467 -* When the set value is lower than40, it changes to the default value 300467 +* When the set value is greater than 1000, it changes to the default value 300 468 468 ))) 469 469 |=(% style="width: 160px;" %)HSW1087|(% style="width:282px" %)Control write interval in address mapping|(% style="width:452px" %)((( 470 470 After reading data to the device for N times, Perform an address mapping write operation. N is the interval value. The effective range: 0~~5, and default is 2. ... ... @@ -918,10 +918,10 @@ 918 918 |=(% style="width: 160px;" %)HSW10000~~19999|(% style="width:282px" %)Power-down storage area|(% style="width:452px" %)After restart, the data remains 919 919 |=(% style="width: 160px;" %)HSW10035|(% rowspan="13" style="width:282px" %)((( 920 920 Note: Valid when Ethernet1 of HMI is plugged into the network cable. 921 -① 922 -② When the Ethernet setting is not enabled in the engineering parameters, the register displays the Ethernet IP automatically acquired by the HMI. 923 -③ When the HMI is not plugged into the network cable, the register will show 0 whether the engineering parameters are set or not. 924 -④ 921 +①、When the Ethernet setting is enabled in the project parameters, this register displays the set value. 922 +②. When the Ethernet setting is not enabled in the engineering parameters, the register displays the Ethernet IP automatically acquired by the HMI. 923 +③. When the HMI is not plugged into the network cable, the register will show 0 whether the engineering parameters are set or not. 924 +④.IP related registers can be read and written (only static IP mode can be written). 925 925 )))|(% style="width:452px" %)Local IP address high byte 1 926 926 |=(% style="width: 160px;" %)HSW10036|(% style="width:452px" %)Local IP address high byte 2 927 927 |=(% style="width: 160px;" %)HSW10037|(% style="width:452px" %)Local IP address high byte 3