Changes for page 13 HMI Internal Registers

Last modified by Jett on 2025/04/28 16:07

From version 29.1
edited by Mora Zhou
on 2023/10/27 16:33
Change comment: There is no comment for this version
To version 11.1
edited by Theodore Xu
on 2022/12/16 10:14
Change comment: There is no comment for this version

Summary

Details

Page properties
Title
... ... @@ -1,1 +1,1 @@
1 -13.HMI Internal Registers
1 +12 HMI internal registers
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.Mora
1 +XWiki.AiXia
Content
... ... @@ -25,11 +25,6 @@
25 25  * The address of the bit address HDX is with a decimal point while word addresses are integers.
26 26  )))
27 27  
28 -= Address ranges table =
29 -
30 -(% style="text-align:center" %)
31 -[[image:6.png]]
32 -
33 33  = **Data storage area (HDW/HDX)** =
34 34  
35 35  It is used to save the temporary data of project.
... ... @@ -65,8 +65,8 @@
65 65  
66 66  It is used for system special registers (reserved by system).
67 67  
68 -1. Access as word, and serial number range is from HUW0 to HUW1599.
69 -1. Access as bit, and serial number range is from HUX0.0 to HUX1599.15.
63 +1. Access as word, and serial number range is from HUW0 to HUW199999.
64 +1. Access as bit, and serial number range is from HUX0.0 to HUX199999.15.
70 70  
71 71  **✎Note:**
72 72  
... ... @@ -155,7 +155,7 @@
155 155  )))
156 156  |=(% style="width: 160px;" %)HSW6~~HSW7|(% style="width:282px" %)Number of alarms|(% style="width:452px" %)The number of alarm (it also includes the records of alarm confirmed)
157 157  |=(% style="width: 160px;" %)HSW8|(% style="width:282px" %)Number of unconfirmed history alarm|(% style="width:452px" %)The number of unconfirmed history alarm
158 -|=(% style="width: 160px;" %)HSW9|(% style="width:282px" %)Time out prompt|(% style="width:452px" %)(((
153 +|=(% style="width: 160px;" %)HSW9|(% style="width:282px" %)Time out tip|(% style="width:452px" %)(((
159 159  * =0: Enable
160 160  * =1: Disable
161 161  )))
... ... @@ -246,8 +246,8 @@
246 246  * =2: HSX521.1=1, delete all trend graph.
247 247  * =4: HSX521.2=1, delete all alarms.
248 248  * =16: HSX521.4=1, delete history XY plot.
249 -* =32: HSX521.5=1, delete data records in SD card or USB flash disk;(Please make a setting which is saved to USB flash disk or SD card in project setting).
250 -* =64: HSX521.6=1, delete alarms records in SD card or USB flash disk; (Please make a setting which is saved to USB flash disk or SD card in project setting).
244 +* =32: HSX521.5=1, delete data records in SD card or flash dish;(Please make a setting which is saved to flash disk or SD card in project setting).
245 +* =64: HSX521.6=1, delete alarms records in SD card or flash dish; (Please make a setting which is saved to flash disk or SD card in project setting).
251 251  )))
252 252  |=(% style="width: 160px;" %)HSW522|(% style="width:282px" %)Copy and paste the alarm/data files in flash to the USB flash disk|(% style="width:452px" %)(((
253 253  * =0: No operation
... ... @@ -455,7 +455,7 @@
455 455  Address mapping polling cycle, effective range: 40~~1000ms, default: 300ms.
456 456  
457 457  * When the set value is greater than 1000, the value is 1000.
458 -* When the set value is lower than 40, it changes to the default value 300
453 +* When the set value is greater than 1000, it changes to the default value 300
459 459  )))
460 460  |=(% style="width: 160px;" %)HSW1087|(% style="width:282px" %)Control write interval in address mapping|(% style="width:452px" %)(((
461 461  After reading data to the device for N times, Perform an address mapping write operation. N is the interval value. The effective range: 0~~5, and default is 2.
... ... @@ -490,8 +490,6 @@
490 490  * =0, Default value
491 491  * =1, Release the alarm generated before the last power-down when starting up
492 492  )))
493 -|=(% style="width: 160px;" %)HSW1200|(% colspan="1" rowspan="2" style="width:282px" %)TSAP settings for HMI in the Siemens LOGO! 8 protocol(ig series or HMI V2.0)|(% style="width:452px" %)HMI local TSAP, which corresponds to the remote TSAP of PLC
494 -|=(% style="width: 160px;" %)HSW1201|(% style="width:452px" %)HMI remote TSAP, which corresponds to the local TSAP of PLC
495 495  |=(% style="width: 160px;" %)HSW1450|(% style="width:282px" %)Enable objects level password function|(% style="width:452px" %)(((
496 496  * =0, Disable
497 497  * =1, Enable
... ... @@ -598,9 +598,6 @@
598 598  * =0: Server connection exception
599 599  * =1: Server connection is OK
600 600  )))
601 -|=(% style="width: 160px;" %)HSW1740|(% style="width:282px" %)Wi-fi signal strength|(% style="width:452px" %)(((
602 -Display the value of Wi-fi signal signal strength, ranges from 0~~100 (Signal strength is automatically obtained only once when HMI is powered on, and it will not be automatically updated. It needs to be used with the HSW1890)
603 -)))
604 604  |=(% style="width: 160px;" %)HSW1741|(% colspan="1" rowspan="12" style="width:282px" %)Related IP register in 4Gnetwork status (It is valid when HMI is connected to 4G)|(% style="width:452px" %)Local IP address high byte 1
605 605  |=(% style="width: 160px;" %)HSW1742|(% style="width:452px" %)Local IP address high byte 2
606 606  |=(% style="width: 160px;" %)HSW1743|(% style="width:452px" %)Local IP address high byte 3
... ... @@ -628,180 +628,10 @@
628 628  * =1: Server connection is OK
629 629  )))
630 630  |=(% style="width: 160px;" %)HSW1761|(% style="width:282px" %)Display 4G network signal strength|(% style="width:452px" %)Signal strength: 0~~31. The greater the value ,the signal is stronger
631 -|=(% style="width: 160px;" %)(((
632 -HSW1762
633 -)))|(% colspan="1" rowspan="13" style="width:282px" %)(((
634 -Note: Valid when Ethernet2 of HMI is plugged into the network cable.
635 -①、When the Ethernet setting is enabled in the project parameters, this register displays the set value.
636 -②. When the Ethernet setting is not enabled in the engineering parameters, the register displays the Ethernet IP automatically acquired by the HMI.
637 -③. When the HMI is not plugged into the network cable, the register will show 0 whether the engineering parameters are set or not.
638 -④.IP related registers can be read and written (only static IP mode can be written).
639 -)))|(% style="width:452px" %)(((
640 -Ethernet2 Local IP address high byte 1
641 -)))
642 -|=(% style="width: 160px;" %)(((
643 -HSW1763
644 -)))|(% style="width:452px" %)(((
645 -Ethernet2 Local IP address high byte 2
646 -)))
647 -|=(% style="width: 160px;" %)(((
648 -HSW1764
649 -)))|(% style="width:452px" %)(((
650 -Ethernet2 Local IP address high byte 3
651 -)))
652 -|=(% style="width: 160px;" %)(((
653 -HSW1765
654 -)))|(% style="width:452px" %)(((
655 -Ethernet2 Local IP address high byte 4
656 -)))
657 -|=(% style="width: 160px;" %)(((
658 -HSW1766
659 -)))|(% style="width:452px" %)(((
660 -Ethernet2 Local mask IP address high byte 1
661 -)))
662 -|=(% style="width: 160px;" %)(((
663 -HSW1767
664 -)))|(% style="width:452px" %)(((
665 -Ethernet2 Local mask IP address high byte 2
666 -)))
667 -|=(% style="width: 160px;" %)(((
668 -HSW1768
669 -)))|(% style="width:452px" %)Ethernet2 Local mask IP address high byte 3
670 -|=(% style="width: 160px;" %)HSW1769|(% style="width:452px" %)Ethernet2 Local mask IP address high byte 4
671 -|=(% style="width: 160px;" %)(((
672 -HSW1770
673 -)))|(% style="width:452px" %)(((
674 -Ethernet2 Local gateway IP address high byte 1
675 -)))
676 -|=(% style="width: 160px;" %)(((
677 -HSW1771
678 -)))|(% style="width:452px" %)(((
679 -Ethernet2 Local gateway IP address high byte 2
680 -)))
681 -|=(% style="width: 160px;" %)(((
682 -HSW1772
683 -)))|(% style="width:452px" %)(((
684 -Ethernet2 Local gateway IP address high byte 3
685 -)))
686 -|=(% style="width: 160px;" %)(((
687 -HSW1773
688 -)))|(% style="width:452px" %)(((
689 -Ethernet2 Local gateway IP address high byte 4
690 -)))
691 -|=(% style="width: 160px;" %)(((
692 -HSW1774
693 -)))|(% style="width:452px" %)(((
694 -Ethernet2 Local Port Address
695 -)))
696 -|=(% style="width: 160px;" %)(((
697 -HSW1775
698 -)))|(% colspan="1" rowspan="6" style="width:282px" %)(((
699 -①Display the MAC code of Ethernet2 NIC
700 -
701 -(hexadecimal display)
702 -
703 -②Read-only mode, not modifiable
704 -)))|(% style="width:452px" %)(((
705 -Ethernet2 Local MAC code high byte 1
706 -)))
707 -|=(% style="width: 160px;" %)(((
708 -HSW1776
709 -)))|(% style="width:452px" %)(((
710 -Ethernet2 Local MAC code high byte 2
711 -)))
712 -|=(% style="width: 160px;" %)(((
713 -HSW1777
714 -)))|(% style="width:452px" %)(((
715 -Ethernet2 Local MAC code high byte 3
716 -)))
717 -|=(% style="width: 160px;" %)(((
718 -HSW1778
719 -)))|(% style="width:452px" %)(((
720 -Ethernet2 Local MAC code high byte 4
721 -)))
722 -|=(% style="width: 160px;" %)(((
723 -HSW1779
724 -)))|(% style="width:452px" %)(((
725 -Ethernet2 Local MAC code high byte 5
726 -)))
727 -|=(% style="width: 160px;" %)(((
728 -HSW1780
729 -)))|(% style="width:452px" %)(((
730 -Ethernet2 Local MAC code high byte 6
731 -)))
732 -|=(% style="width: 160px;" %)(((
733 -HSW1781
734 -)))|(% colspan="1" rowspan="8" style="width:282px" %)(((
735 -①Display and modify DNS1 and DNS2 of Ethernet2
736 -
737 -②Related registers can be read and written mode (only static IP mode can be written)
738 -)))|(% style="width:452px" %)(((
739 -Ethernet2 Local DNS1 address high byte 1
740 -)))
741 -|=(% style="width: 160px;" %)(((
742 -HSW1782
743 -)))|(% style="width:452px" %)(((
744 -Ethernet2 Local DNS1 address high byte 2
745 -)))
746 -|=(% style="width: 160px;" %)(((
747 -HSW1783
748 -)))|(% style="width:452px" %)(((
749 -Ethernet2 Local DNS1 address high byte 3
750 -)))
751 -|=(% style="width: 160px;" %)(((
752 -HSW1784
753 -)))|(% style="width:452px" %)(((
754 -Ethernet2 Local DNS1 address high byte 4
755 -)))
756 -|=(% style="width: 160px;" %)(((
757 -HSW1785
758 -)))|(% style="width:452px" %)(((
759 -Ethernet2 Local DNS2 address high byte 1
760 -)))
761 -|=(% style="width: 160px;" %)(((
762 -HSW1786
763 -)))|(% style="width:452px" %)(((
764 -Ethernet2 Local DNS2 address high byte 2
765 -)))
766 -|=(% style="width: 160px;" %)(((
767 -HSW1787
768 -)))|(% style="width:452px" %)(((
769 -Ethernet2 Local DNS2 address high byte 3
770 -)))
771 -|=(% style="width: 160px;" %)(((
772 -HSW1788
773 -)))|(% style="width:452px" %)(((
774 -Ethernet2 Local DNS2 address high byte 4
775 -)))
776 -|=(% style="width: 160px;" %)(((
777 -HSW1789
778 -)))|(% colspan="1" style="width:282px" %)(((
779 -Display or set the dynamic or static IP mode of Ethernet2
780 -)))|(% style="width:452px" %)(((
781 -HSX1789.0 = 0, Static IP mode
782 -
783 -HSX1789.0 = 1, dynamic IP mode
784 -)))
785 -|=(% style="width: 160px;" %)(((
786 -HSW1790
787 -)))|(% colspan="1" style="width:282px" %)(((
788 -Confirm Ethernet2 IP, subnet mask, gateway, DNS1, DNS2, and dynamic static IP settings
789 -)))|(% style="width:452px" %)(((
790 -~= 1, confirm the setting (i.e., after modifying IP-related information, set this address to 1, representing confirmation of the modification, after which it will be reset to 0)
791 -)))
792 -|=(% style="width: 160px;" %)(((
793 -HSW1791
794 -)))|(% colspan="1" style="width:282px" %)(((
795 -Network status of the Ethernet2 connection server
796 -)))|(% style="width:452px" %)(((
797 -~= 0, connection to the server is abnormal = 1, connection to the server is normal
798 -)))
799 799  |=(% style="width: 160px;" %)HSW1852|(% style="width:282px" %)Control the interval in two consecutive clicks|(% style="width:452px" %)Limit range: 1~~500ms. The default is 100 ms.
800 800  |=(% style="width: 160px;" %)HSW1853|(% style="width:282px" %)File format for exporting data records to USB flash drive or SD card|(% style="width:452px" %)(((
801 801  * =0: db database
802 802  * =1: CSV
803 -
804 -(Only valid for script function DbToCsvFile)
805 805  )))
806 806  |=(% style="width: 160px;" %)HSW1854|(% style="width:282px" %)High and low word conversion type|(% style="width:452px" %)(((
807 807  * =0: use the old high-low word conversion (default)
... ... @@ -828,7 +828,7 @@
828 828  * =1: priority WLAN
829 829  * =2: priority 4G
830 830  )))
831 -|=(% style="width: 160px;" %)HSW1866|(% style="width:282px" %)Delete the Lua extension module file|(% style="width:452px" %)(((
651 +|=(% style="width: 160px;" %)HSW1866|(% style="width:282px" %)Delete the LUa extension module file|(% style="width:452px" %)(((
832 832  * =0: delete;
833 833  * = Others: do not delete
834 834  )))
... ... @@ -844,75 +844,14 @@
844 844  * = 0: yes (default);
845 845  * = 1: no
846 846  )))
847 -|=(% style="width: 160px;" %)(((
848 -HSW1869
849 -)))|(% style="width:282px" %)(((
850 -Dynamic screensaver countdown
851 -)))|(% style="width:452px" %)(((
852 -Countdown to enter dynamic screensaver effect, unit (S)
853 -)))
854 -|=(% style="width: 160px;" %)(((
855 -HSW1870
856 -)))|(% style="width:282px" %)(((
857 -Display or set the dynamic or static IP mode of Ethernet1
858 -)))|(% style="width:452px" %)(((
859 -HSX1870.0 = 0, Static IP mode
860 -
861 -HSX1870.0 = 1, dynamic IP mode
862 -)))
863 -|=(% style="width: 160px;" %)(((
864 -HSW1871
865 -)))|(% style="width:282px" %)(((
866 -Confirm the IP, subnet mask, gateway, DNS1, DNS2, and dynamic static IP settings for Ethernet1
867 -)))|(% style="width:452px" %)(((
868 -~= 1, confirm the setting (i.e., after modifying IP-related information, set this address to 1, representing confirmation of the modification, after which it will be reset to 0)
869 -)))
870 -|=(% style="width: 160px;" %)(((
871 -HSW1872
872 -)))|(% colspan="1" rowspan="8" style="width:282px" %)(((
873 -①Display and modify DNS1 and DNS2 of Ethernet1
874 -
875 -②Related registers can be read and written mode (only static IP mode can be written)
876 -)))|(% style="width:452px" %)(((
877 -Ethernet1 Local DNS1 address high byte 1
878 -)))
879 -|=(% style="width: 160px;" %)(((
880 -HSW1873
881 -)))|(% style="width:452px" %)Ethernet1 Local DNS1 address high byte 2
882 -|=(% style="width: 160px;" %)(((
883 -HSW1874
884 -)))|(% style="width:452px" %)Ethernet1 Local DNS1 address high byte 3
885 -|=(% style="width: 160px;" %)(((
886 -HSW1875
887 -)))|(% style="width:452px" %)Ethernet1 Local DNS1 address high byte 4
888 -|=(% style="width: 160px;" %)(((
889 -HSW1876
890 -)))|(% style="width:452px" %)Ethernet1 Local DNS2 address high byte 1
891 -|=(% style="width: 160px;" %)(((
892 -HSW1877
893 -)))|(% style="width:452px" %)Ethernet1 Local DNS2 address high byte 2
894 -|=(% style="width: 160px;" %)(((
895 -HSW1878
896 -)))|(% style="width:452px" %)Ethernet1 Local DNS2 address high byte 3
897 -|=(% style="width: 160px;" %)(((
898 -HSW1879
899 -)))|(% style="width:452px" %)Ethernet1 Local DNS2 address high byte 4
900 -|=(% style="width: 160px;" %)HSW1890|(% colspan="1" style="width:282px" %)Enable refresh current network signal|(% style="width:452px" %)(((
901 -* =1: Refresh the network signal once after triggered (This register will be automatically reset after triggered, only update the signal value once after per 15 seconds, not able to update twice in the short interval)
902 -* =Others: not refresh
903 -)))
904 -|=(% style="width: 160px;" %)HSW1891|(% colspan="1" style="width:282px" %)Enable clear cache for screen data  |(% style="width:452px" %)(((
905 -* =1, not clear screen cache when switch language
906 -* =2, trigger clear cache of all screens for once time
907 -* =3, always clear cache of all screen data
908 -)))
909 909  |=(% style="width: 160px;" %)HSW10000~~19999|(% style="width:282px" %)Power-down storage area|(% style="width:452px" %)After restart, the data remains
910 910  |=(% style="width: 160px;" %)HSW10035|(% rowspan="13" style="width:282px" %)(((
911 -Note: Valid when Ethernet1 of HMI is plugged into the network cable.
912 -① When the Ethernet setting is enabled in the project parameters, this register displays the set value.
913 -② When the Ethernet setting is not enabled in the engineering parameters, the register displays the Ethernet IP automatically acquired by the HMI.
914 -③ When the HMI is not plugged into the network cable, the register will show 0 whether the engineering parameters are set or not.
915 -④ IP related registers can be read and written (only static IP mode can be written).
669 +**✎Note: **Only valid when the HMI is plugged into the Ethernet cable.
670 +
671 +1. If Ethernet settings is enabled in project parameters, this register displays the set value.
672 +1. If Ethernet settings is not enabled in project parameters, IP would automatically obtained IP.
673 +1. If HMI is not connected to the network, the register is displayed as 0 whether the engineering parameters are set.
674 +1. 4. All IP registers of HMI are read-only.
916 916  )))|(% style="width:452px" %)Local IP address high byte 1
917 917  |=(% style="width: 160px;" %)HSW10036|(% style="width:452px" %)Local IP address high byte 2
918 918  |=(% style="width: 160px;" %)HSW10037|(% style="width:452px" %)Local IP address high byte 3
... ... @@ -927,11 +927,9 @@
927 927  |=(% style="width: 160px;" %)HSW10046|(% style="width:452px" %)Local gateway address high byte 4
928 928  |=(% style="width: 160px;" %)HSW10047|(% style="width:452px" %)Local port address
929 929  |=(% style="width: 160px;" %)HSW10048|(% rowspan="6" style="width:282px" %)(((
930 -Display the MAC code of Ethernet1 NIC
689 +Displays the MAC code of the current network card
931 931  
932 -(hexadecimal display)
933 -
934 -②Read-only mode, not modifiable
691 +(Hexadecimal display)
935 935  )))|(% style="width:452px" %)Local MAC code high word 1
936 936  |=(% style="width: 160px;" %)HSW10049|(% style="width:452px" %)Local MAC code high word 2
937 937  |=(% style="width: 160px;" %)HSW10050|(% style="width:452px" %)Local MAC code high word 3
... ... @@ -938,7 +938,7 @@
938 938  |=(% style="width: 160px;" %)HSW10051|(% style="width:452px" %)Local MAC code high word 4
939 939  |=(% style="width: 160px;" %)HSW10052|(% style="width:452px" %)Local MAC code high word 5
940 940  |=(% style="width: 160px;" %)HSW10053|(% style="width:452px" %)Local MAC code high word 6
941 -|=(% style="width: 160px;" %)HSW10118|(% colspan="1" rowspan="2" style="width:282px" %)TSAP settings for HMI in the Siemens LOGO! 8 protocol|(% style="width:452px" %)HMI local TSAP, which corresponds to the remote TSAP of PLC
698 +|=(% style="width: 160px;" %)HSW10118|(% colspan="1" rowspan="2" style="width:282px" %)TSAP settings for HMI in the Siemens logo! 8 protocol|(% style="width:452px" %)HMI local TSAP, which corresponds to the remote TSAP of PLC
942 942  |=(% style="width: 160px;" %)HSW10119|(% style="width:452px" %)HMI remote TSAP, which corresponds to the local TSAP of PLC
943 943  |=(% style="width: 160px;" %)HSW10461~~10493|(% style="width:282px" %)Remote access password|(% style="width:452px" %)8-character remote access password
944 944  |=(% style="width: 160px;" %)HSW10494~~10558|(% style="width:282px" %)Machine ID (Read only)|(% style="width:452px" %)Machine ID for remote access (read only 64-bit)
... ... @@ -1020,34 +1020,7 @@
1020 1020  )))
1021 1021  |=(% style="width: 160px;" %)HSW11760|(% style="width:282px" %)Screensaver countdown|(% style="width:452px" %)Display the countdown to enter the Screensaver, unit: second.
1022 1022  |=(% style="width: 160px;" %)HSW11761|(% style="width:282px" %)Screensaver screen number|(% style="width:452px" %)Set the screen number for Screensaver
1023 -|=(% style="width: 160px;" %)(((
1024 -HSW11762
1025 -)))|(% style="width:282px" %)(((
1026 -Dynamic screensaver control address
1027 -)))|(% style="width:452px" %)(((
1028 -HSX11762.0=0, initialize with project configuration;
1029 1029  
1030 -HSX11762.0=1, initialize with special register configuration;
1031 -
1032 -HSX11762.1=0, disable dynamic screensaver;
1033 -
1034 -HSX11762.1=1, enable dynamic screensaver
1035 -)))
1036 -|=(% style="width: 160px;" %)(((
1037 -HSW11763
1038 -)))|(% style="width:282px" %)(((
1039 -Waiting time to enter the dynamic screensaver
1040 -)))|(% style="width:452px" %)(((
1041 -Waiting time when the screen is not operated, range 1~~720 minutes
1042 -)))
1043 -|=(% style="width: 160px;" %)(((
1044 -HSW11764
1045 -)))|(% style="width:282px" %)(((
1046 -Animated screensaver animation type
1047 -)))|(% style="width:452px" %)(((
1048 -~=0: Raster,=1: Blinds,=2: Bubble
1049 -)))
1050 -
1051 1051  == Serial port communication configuration ==
1052 1052  
1053 1053  (% class="table-bordered" %)
6.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Mora
Size
... ... @@ -1,1 +1,0 @@
1 -20.1 KB
Content