Changes for page 13 HMI Internal Registers

Last modified by Jett on 2025/04/28 16:07

From version 29.1
edited by Mora Zhou
on 2023/10/27 16:33
Change comment: There is no comment for this version
To version 24.1
edited by Hunter
on 2023/02/20 15:58
Change comment: There is no comment for this version

Summary

Details

Page properties
Title
... ... @@ -1,1 +1,1 @@
1 -13.HMI Internal Registers
1 +12 HMI internal registers
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.Mora
1 +XWiki.Hunter
Content
... ... @@ -27,8 +27,17 @@
27 27  
28 28  = Address ranges table =
29 29  
30 -(% style="text-align:center" %)
31 -[[image:6.png]]
30 +(% cellpadding="10" %)
31 +|=(% scope="row" style="width: 218px;" %)Address Type\HMI Series|=(% style="width: 228px;" %)General Series|=(% style="width: 200px;" %)i /HMI+ Series|=(% style="width: 136px;" %)ie Series|=(% style="width: 232px;" %)ig Series
32 +|=(% style="width: 218px;" %)HDW|(% style="width:228px" %)HDW0-HDW299999|HDW0-HDW299999|HDW0-HDW299999|HDW0-HDW299999
33 +|=(% style="width: 218px;" %)HSW|(% style="width:228px" %)HSW0-HSW14999|HSW0-HSW14999|HSW0-HSW14999|HSW0-HSW14999
34 +|=(% style="width: 218px;" %)HAW|(% style="width:228px" %)HAW0-HAW199999|HAW0-HAW199999|HAW0-HAW199999|HAW0-HAW199999
35 +|=(% style="width: 218px;" %)HUW|(% style="width:228px" %)HUW0-HUW1599|HUW0-HUW1599|HUW0-HUW1599|HUW0-HUW1599
36 +|=(% style="width: 218px;" %)HDX|(% style="width:228px" %)HDX0.0-HDX299999.15|HDX0.0-HDX299999.15|HDX0.0-HDX299999.15|HDX0.0-HDX299999.15
37 +|=(% style="width: 218px;" %)HSX|(% style="width:228px" %)HSX0.0-HSX14999.15|HSX0.0-HSX14999.15|HSX0-HSX14999.15|HSX0.0-HSX14999.15
38 +|=(% style="width: 218px;" %)HAX|(% style="width:228px" %)HAX0.0-HAX199999.15|HAX0.0-HAX199999.15|HAX0.0-HAX199999.15|HAX0.0-HAX199999.15
39 +|=(% style="width: 218px;" %)HUX|(% style="width:228px" %)HUX0.0-HUX1599.15|HUX0.0-HUX1599.15|HUX0.0-HUX1599.15|HUX0.0-HUX1599.15
40 +|=(% style="width: 218px;" %)RPW|(% style="width:228px" %) |RPW000000-RPW990450|RPW000000-RPW990450|RPW000000-RPW990450
32 32  
33 33  = **Data storage area (HDW/HDX)** =
34 34  
... ... @@ -155,7 +155,7 @@
155 155  )))
156 156  |=(% style="width: 160px;" %)HSW6~~HSW7|(% style="width:282px" %)Number of alarms|(% style="width:452px" %)The number of alarm (it also includes the records of alarm confirmed)
157 157  |=(% style="width: 160px;" %)HSW8|(% style="width:282px" %)Number of unconfirmed history alarm|(% style="width:452px" %)The number of unconfirmed history alarm
158 -|=(% style="width: 160px;" %)HSW9|(% style="width:282px" %)Time out prompt|(% style="width:452px" %)(((
167 +|=(% style="width: 160px;" %)HSW9|(% style="width:282px" %)Time out tip|(% style="width:452px" %)(((
159 159  * =0: Enable
160 160  * =1: Disable
161 161  )))
... ... @@ -455,7 +455,7 @@
455 455  Address mapping polling cycle, effective range: 40~~1000ms, default: 300ms.
456 456  
457 457  * When the set value is greater than 1000, the value is 1000.
458 -* When the set value is lower than 40, it changes to the default value 300
467 +* When the set value is greater than 1000, it changes to the default value 300
459 459  )))
460 460  |=(% style="width: 160px;" %)HSW1087|(% style="width:282px" %)Control write interval in address mapping|(% style="width:452px" %)(((
461 461  After reading data to the device for N times, Perform an address mapping write operation. N is the interval value. The effective range: 0~~5, and default is 2.
... ... @@ -909,10 +909,10 @@
909 909  |=(% style="width: 160px;" %)HSW10000~~19999|(% style="width:282px" %)Power-down storage area|(% style="width:452px" %)After restart, the data remains
910 910  |=(% style="width: 160px;" %)HSW10035|(% rowspan="13" style="width:282px" %)(((
911 911  Note: Valid when Ethernet1 of HMI is plugged into the network cable.
912 -① When the Ethernet setting is enabled in the project parameters, this register displays the set value.
913 -② When the Ethernet setting is not enabled in the engineering parameters, the register displays the Ethernet IP automatically acquired by the HMI.
914 -③ When the HMI is not plugged into the network cable, the register will show 0 whether the engineering parameters are set or not.
915 -④ IP related registers can be read and written (only static IP mode can be written).
921 +①When the Ethernet setting is enabled in the project parameters, this register displays the set value.
922 +②. When the Ethernet setting is not enabled in the engineering parameters, the register displays the Ethernet IP automatically acquired by the HMI.
923 +③. When the HMI is not plugged into the network cable, the register will show 0 whether the engineering parameters are set or not.
924 +④.IP related registers can be read and written (only static IP mode can be written).
916 916  )))|(% style="width:452px" %)Local IP address high byte 1
917 917  |=(% style="width: 160px;" %)HSW10036|(% style="width:452px" %)Local IP address high byte 2
918 918  |=(% style="width: 160px;" %)HSW10037|(% style="width:452px" %)Local IP address high byte 3
6.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Mora
Size
... ... @@ -1,1 +1,0 @@
1 -20.1 KB
Content