Changes for page 13 HMI Internal Registers
Last modified by Jett on 2025/04/28 16:07
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -56,10 +56,13 @@ 56 56 57 57 It is system recipe data power-off save register. The range is from RPW000000 to RPW990450. 58 58 59 +(% class="box infomessage" %) 60 +((( 59 59 **✎Note:** 60 60 61 61 * RPW is power-down retention. The register of this type is able to save the data before the power-down. 62 62 * To avoid possible device failure, do not immediately power off and reboot when configuring the power-down save addre 65 +))) 63 63 64 64 = **Single user data area (HUW/HUX)** = 65 65 ... ... @@ -140,8 +140,8 @@ 140 140 (% class="table-bordered" style="width:1024px" %) 141 141 |=(% scope="row" style="width: 160px;" %)**Address**|=(% style="width: 282px;" %)**Function**|=(% style="width: 452px;" %)**Description** 142 142 |=(% style="width: 160px;" %)HSW0|(% style="width:282px" %)Language switch|(% style="width:452px" %)Multiple language could be set in the project, HMI support maximum 8 languages. (Power-down save supported) 143 -|=(% style="width: 160px;" %)HSW1|(% style="width:282px" %)Beep frequency|(% style="width:452px" %)Frequency range: 0~~4000 144 -|=(% style="width: 160px;" %)HSW2|(% style="width:282px" %)Beep volume|(% style="width:452px" %)Volume range: 0~~80 146 +|=(% style="width: 160px;" %)HSW1|(% style="width:282px" %)Beep frequency (Only valid in HMI V1.0 System)|(% style="width:452px" %)Frequency range: 0~~4000 147 +|=(% style="width: 160px;" %)HSW2|(% style="width:282px" %)Beep volume (Only valid in HMI V1.0 System)|(% style="width:452px" %)Volume range: 0~~80 145 145 |=(% style="width: 160px;" %)HSW3|(% style="width:282px" %)Beep time|(% style="width:452px" %)Unit: ms 146 146 |=(% style="width: 160px;" %)HSW4|(% style="width:282px" %)Beep whether enable or not|(% style="width:452px" %)((( 147 147 * =0: Enable. ... ... @@ -180,6 +180,7 @@ 180 180 * =5: Friday. 181 181 * =6: Saturday. 182 182 ))) 186 +|=(% style="width: 160px;" %)HSW39|(% style="width:282px" %)Beep type(Only valid in HMI V2.0 System)|(% style="width:452px" %)Type range: 1-5, Default is 1. 183 183 |=(% style="width: 160px;" %)HSW134|(% style="width:282px" %)((( 184 184 Whether the Script is read through 185 185 ... ... @@ -1006,6 +1006,7 @@ 1006 1006 * =0: LAN or the external network both OK 1007 1007 * =1: Only LAN access 1008 1008 * =2: Only external network can access 1013 +* =3: Close the functions 1009 1009 ))) 1010 1010 |=(% style="width: 160px;" %)HSW11757|(% style="width:282px" %)Enable the valid date of the dynamic installment password|(% style="width:452px" %)((( 1011 1011 * =0: Disabled