Changes for page 13 HMI Internal Registers

Last modified by Jett on 2025/04/28 16:07

From version 29.1
edited by Mora Zhou
on 2023/10/27 16:33
Change comment: There is no comment for this version
To version 32.1
edited by Mora Zhou
on 2023/11/21 16:20
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -56,10 +56,13 @@
56 56  
57 57  It is system recipe data power-off save register. The range is from RPW000000 to RPW990450.
58 58  
59 +(% class="box infomessage" %)
60 +(((
59 59  **✎Note:**
60 60  
61 61  * RPW is power-down retention. The register of this type is able to save the data before the power-down.
62 62  * To avoid possible device failure, do not immediately power off and reboot when configuring the power-down save addre
65 +)))
63 63  
64 64  = **Single user data area (HUW/HUX)** =
65 65  
... ... @@ -68,9 +68,12 @@
68 68  1. Access as word, and serial number range is from HUW0 to HUW1599.
69 69  1. Access as bit, and serial number range is from HUX0.0 to HUX1599.15.
70 70  
74 +(% class="box infomessage" %)
75 +(((
71 71  **✎Note:**
72 72  
73 73  * HUW/HUX is a system special register, so please check the system special register list during use. Please use the address specified in the table and do not use the address which is not mentioned in the table.
79 +)))
74 74  
75 75  (% class="table-bordered" %)
76 76  |=**Special register address**|=**Description**|=**Function**
... ... @@ -140,8 +140,8 @@
140 140  (% class="table-bordered" style="width:1024px" %)
141 141  |=(% scope="row" style="width: 160px;" %)**Address**|=(% style="width: 282px;" %)**Function**|=(% style="width: 452px;" %)**Description**
142 142  |=(% style="width: 160px;" %)HSW0|(% style="width:282px" %)Language switch|(% style="width:452px" %)Multiple language could be set in the project, HMI support maximum 8 languages. (Power-down save supported)
143 -|=(% style="width: 160px;" %)HSW1|(% style="width:282px" %)Beep frequency|(% style="width:452px" %)Frequency range: 0~~4000
144 -|=(% style="width: 160px;" %)HSW2|(% style="width:282px" %)Beep volume|(% style="width:452px" %)Volume range: 0~~80
149 +|=(% style="width: 160px;" %)HSW1|(% style="width:282px" %)Beep frequency (Only valid in HMI V1.0 System)|(% style="width:452px" %)Frequency range: 0~~4000
150 +|=(% style="width: 160px;" %)HSW2|(% style="width:282px" %)Beep volume (Only valid in HMI V1.0 System)|(% style="width:452px" %)Volume range: 0~~80
145 145  |=(% style="width: 160px;" %)HSW3|(% style="width:282px" %)Beep time|(% style="width:452px" %)Unit: ms
146 146  |=(% style="width: 160px;" %)HSW4|(% style="width:282px" %)Beep whether enable or not|(% style="width:452px" %)(((
147 147  * =0: Enable.
... ... @@ -180,6 +180,7 @@
180 180  * =5: Friday.
181 181  * =6: Saturday.
182 182  )))
189 +|=(% style="width: 160px;" %)HSW39|(% style="width:282px" %)Beep type(Only valid in HMI V2.0 System)|(% style="width:452px" %)Type range: 1-5, Default is 1.
183 183  |=(% style="width: 160px;" %)HSW134|(% style="width:282px" %)(((
184 184  Whether the Script is read through
185 185  
... ... @@ -1006,6 +1006,7 @@
1006 1006  * =0: LAN or the external network both OK
1007 1007  * =1: Only LAN access
1008 1008  * =2: Only external network can access
1016 +* =3: Close the functions
1009 1009  )))
1010 1010  |=(% style="width: 160px;" %)HSW11757|(% style="width:282px" %)Enable the valid date of the dynamic installment password|(% style="width:452px" %)(((
1011 1011  * =0: Disabled