Changes for page 13 HMI Internal Registers

Last modified by Jett on 2025/04/28 16:07

From version 29.1
edited by Mora Zhou
on 2023/10/27 16:33
Change comment: There is no comment for this version
To version 33.1
edited by Mora Zhou
on 2023/11/21 16:25
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -56,10 +56,13 @@
56 56  
57 57  It is system recipe data power-off save register. The range is from RPW000000 to RPW990450.
58 58  
59 +(% class="box infomessage" %)
60 +(((
59 59  **✎Note:**
60 60  
61 61  * RPW is power-down retention. The register of this type is able to save the data before the power-down.
62 62  * To avoid possible device failure, do not immediately power off and reboot when configuring the power-down save addre
65 +)))
63 63  
64 64  = **Single user data area (HUW/HUX)** =
65 65  
... ... @@ -68,9 +68,12 @@
68 68  1. Access as word, and serial number range is from HUW0 to HUW1599.
69 69  1. Access as bit, and serial number range is from HUX0.0 to HUX1599.15.
70 70  
74 +(% class="box infomessage" %)
75 +(((
71 71  **✎Note:**
72 72  
73 73  * HUW/HUX is a system special register, so please check the system special register list during use. Please use the address specified in the table and do not use the address which is not mentioned in the table.
79 +)))
74 74  
75 75  (% class="table-bordered" %)
76 76  |=**Special register address**|=**Description**|=**Function**
... ... @@ -132,16 +132,19 @@
132 132  1. Access as word, and serial number range is from HSW0 to HSW49999. (HSW10000 to HSW19999 are the power-off storage areas)
133 133  1. Access as bit, and serial number range is from HSX0.0 to HSX49999.15.
134 134  
141 +(% class="box infomessage" %)
142 +(((
135 135  **✎Note:**
136 136  
137 137  * HSW / HSX are a system special register, so please check the system special register list during use. Please use the address specified in the table and do not use the address which is not mentioned in the table.
138 138  * To avoid possible device failure, do not immediately power off and reboot when configuring the power-down save address.
147 +)))
139 139  
140 140  (% class="table-bordered" style="width:1024px" %)
141 141  |=(% scope="row" style="width: 160px;" %)**Address**|=(% style="width: 282px;" %)**Function**|=(% style="width: 452px;" %)**Description**
142 142  |=(% style="width: 160px;" %)HSW0|(% style="width:282px" %)Language switch|(% style="width:452px" %)Multiple language could be set in the project, HMI support maximum 8 languages. (Power-down save supported)
143 -|=(% style="width: 160px;" %)HSW1|(% style="width:282px" %)Beep frequency|(% style="width:452px" %)Frequency range: 0~~4000
144 -|=(% style="width: 160px;" %)HSW2|(% style="width:282px" %)Beep volume|(% style="width:452px" %)Volume range: 0~~80
152 +|=(% style="width: 160px;" %)HSW1|(% style="width:282px" %)Beep frequency (Only valid in HMI V1.0 System)|(% style="width:452px" %)Frequency range: 0~~4000
153 +|=(% style="width: 160px;" %)HSW2|(% style="width:282px" %)Beep volume (Only valid in HMI V1.0 System)|(% style="width:452px" %)Volume range: 0~~80
145 145  |=(% style="width: 160px;" %)HSW3|(% style="width:282px" %)Beep time|(% style="width:452px" %)Unit: ms
146 146  |=(% style="width: 160px;" %)HSW4|(% style="width:282px" %)Beep whether enable or not|(% style="width:452px" %)(((
147 147  * =0: Enable.
... ... @@ -180,12 +180,16 @@
180 180  * =5: Friday.
181 181  * =6: Saturday.
182 182  )))
192 +|=(% style="width: 160px;" %)HSW39|(% style="width:282px" %)Beep type(Only valid in HMI V2.0 System)|(% style="width:452px" %)Type range: 1-5, Default is 1.
183 183  |=(% style="width: 160px;" %)HSW134|(% style="width:282px" %)(((
184 184  Whether the Script is read through
185 185  
186 186  
187 187  )))|(% style="width:452px" %)(((
198 +(% class="box infomessage" %)
199 +(((
188 188  **✎Note:** If want to read-only or write-only, please enable this settings.
201 +)))
189 189  
190 190  * =0: Read from HMI cache(Default)
191 191  * =1: Read from PLC directly
... ... @@ -296,7 +296,7 @@
296 296  * =2: Ejecting SD card, please waiting…
297 297  * =3: SD card ejected
298 298  )))
299 -|=(% style="width: 160px;" %)HSW550~~849|(% style="width:282px" %)Communication control|(% style="width:452px" %)For communication control and communication lamp (please refer to "[[communication control>>http://13.229.109.52:8080/wiki/pistudio/view/Helps/13.HMI%20internal%20registers/#HCommunicationcontrol]]" sector for detailed)
312 +|=(% style="width: 160px;" %)HSW550~~849|(% style="width:282px" %)Communication control|(% style="width:452px" %)For communication control and communication lamp (please refer to "[[Communication control>>http://13.229.109.52:8080/wiki/pistudio/view/Helps/13.HMI%20internal%20registers/#HCommunicationcontrol]]" sector for detailed)
300 300  |=(% style="width: 160px;" %)HSW850|(% style="width:282px" %)(((
301 301  Network state
302 302  
... ... @@ -345,15 +345,15 @@
345 345  * HDX882.1=1 SD card is reading data, don't remove SD card.
346 346  )))
347 347  |=(% style="width: 160px;" %)HSW884|(% style="width:282px" %)Enter the system network configuration interface|(% style="width:452px" %)(((
348 -* =0: Do not enter the network configuration interface
349 -* =1: Enter the system network configuration interface.
361 +* = 0: Do not enter the network configuration interface
362 +* = 1: Enter the system network configuration interface.
350 350  ** ig series HMI only supports to enter the system interface
351 351  
352 352  )))
353 353  |=(% style="width: 160px;" %)HSW885|(% style="width:282px" %)When the control object hides the address is read failed (communication failure), set the display mode of the object|(% style="width:452px" %)(((
354 354  * = 0: displayed by object setting.
355 -* =1: control address read failure, the address control of all objects is hidden, not displayed.
356 -* =2: control address read failure, the address control of all objects is displayed, not hidden.
368 +* = 1: control address read failure, the address control of all objects is hidden, not displayed.
369 +* = 2: control address read failure, the address control of all objects is displayed, not hidden.
357 357  )))
358 358  |=(% style="width: 160px;" %)HSW893|(% style="width:282px" %)(((
359 359  User Permission Control Address, same as HUW1000 feature, please refer to chapter "[[User Permission>>http://13.229.109.52:8080/wiki/pistudio/view/Helps/08.Basic%20Function/#HUserPermission]]"
... ... @@ -376,7 +376,7 @@
376 376  |=(% style="width: 160px;" %)HSW900|(% style="width:282px" %)Quick update frequency settings for objects|(% style="width:452px" %)(((
377 377  Valid when the object is enabled for "quick update". Default: 5.
378 378  
379 -Range: 1 (fastest) ~~ 50 (slowest)
392 +Range: 1 (fastest) - 50 (slowest)
380 380  )))
381 381  |=(% style="width: 160px;" %)HSW920|(% style="width:282px" %)Static mode Maximum periods|(% style="width:452px" %)Numeric Input/ Display (range: 0-12)
382 382  |=(% style="width: 160px;" %)HSW921 ~~ 924|(% style="width:282px" %)Static mode Admin key|(% style="width:452px" %)Character Input/ Display (length: 8)
... ... @@ -426,8 +426,11 @@
426 426  |=(% style="width: 160px;" %)HSW1070|(% style="width:282px" %)The time interval (seconds) since the last time the screen was clicked|(% style="width:452px" %)(((
427 427  Shows how long the current screen has not been clicked, using a decimal unsigned double word (Numeric Input/ Display).
428 428  
442 +(% class="box infomessage" %)
443 +(((
429 429  **✎Note: **This register is cleared to zero regardless of which user clicks on the screen.
430 430  )))
446 +)))
431 431  |=(% style="width: 160px;" %)HSW1073|(% style="width:282px" %)Corresponding key value from keyboard|(% style="width:452px" %)Display the key value of the currently pressed key, the key value is shown in Table 1 (not updated when the character input display is being input)
432 432  |=(% style="width: 160px;" %)HSW1074|(% style="width:282px" %)Keyboard key status|(% style="width:452px" %)Display the current button status (not updated when the numeric input display is being input)(((
433 433  * =0: key release
... ... @@ -1006,6 +1006,7 @@
1006 1006  * =0: LAN or the external network both OK
1007 1007  * =1: Only LAN access
1008 1008  * =2: Only external network can access
1025 +* =3: Close the functions
1009 1009  )))
1010 1010  |=(% style="width: 160px;" %)HSW11757|(% style="width:282px" %)Enable the valid date of the dynamic installment password|(% style="width:452px" %)(((
1011 1011  * =0: Disabled