Changes for page 13 HMI Internal Registers
Last modified by Jett on 2025/04/28 16:07
Summary
-
Page properties (3 modified, 0 added, 0 removed)
Details
- Page properties
-
- Title
-
... ... @@ -1,1 +1,1 @@ 1 -13 .HMI Internal Registers1 +13 HMI Internal Registers - Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Mora1 +XWiki.2454238480 - Content
-
... ... @@ -56,10 +56,13 @@ 56 56 57 57 It is system recipe data power-off save register. The range is from RPW000000 to RPW990450. 58 58 59 +(% class="box infomessage" %) 60 +((( 59 59 **✎Note:** 60 60 61 61 * RPW is power-down retention. The register of this type is able to save the data before the power-down. 62 62 * To avoid possible device failure, do not immediately power off and reboot when configuring the power-down save addre 65 +))) 63 63 64 64 = **Single user data area (HUW/HUX)** = 65 65 ... ... @@ -68,9 +68,12 @@ 68 68 1. Access as word, and serial number range is from HUW0 to HUW1599. 69 69 1. Access as bit, and serial number range is from HUX0.0 to HUX1599.15. 70 70 74 +(% class="box infomessage" %) 75 +((( 71 71 **✎Note:** 72 72 73 73 * HUW/HUX is a system special register, so please check the system special register list during use. Please use the address specified in the table and do not use the address which is not mentioned in the table. 79 +))) 74 74 75 75 (% class="table-bordered" %) 76 76 |=**Special register address**|=**Description**|=**Function** ... ... @@ -132,16 +132,19 @@ 132 132 1. Access as word, and serial number range is from HSW0 to HSW49999. (HSW10000 to HSW19999 are the power-off storage areas) 133 133 1. Access as bit, and serial number range is from HSX0.0 to HSX49999.15. 134 134 141 +(% class="box infomessage" %) 142 +((( 135 135 **✎Note:** 136 136 137 137 * HSW / HSX are a system special register, so please check the system special register list during use. Please use the address specified in the table and do not use the address which is not mentioned in the table. 138 138 * To avoid possible device failure, do not immediately power off and reboot when configuring the power-down save address. 147 +))) 139 139 140 140 (% class="table-bordered" style="width:1024px" %) 141 141 |=(% scope="row" style="width: 160px;" %)**Address**|=(% style="width: 282px;" %)**Function**|=(% style="width: 452px;" %)**Description** 142 142 |=(% style="width: 160px;" %)HSW0|(% style="width:282px" %)Language switch|(% style="width:452px" %)Multiple language could be set in the project, HMI support maximum 8 languages. (Power-down save supported) 143 -|=(% style="width: 160px;" %)HSW1|(% style="width:282px" %)Beep frequency|(% style="width:452px" %)Frequency range: 0~~4000 144 -|=(% style="width: 160px;" %)HSW2|(% style="width:282px" %)Beep volume|(% style="width:452px" %)Volume range: 0~~80 152 +|=(% style="width: 160px;" %)HSW1|(% style="width:282px" %)Beep frequency (Only valid in HMI V1.0 System)|(% style="width:452px" %)Frequency range: 0~~4000 153 +|=(% style="width: 160px;" %)HSW2|(% style="width:282px" %)Beep volume (Only valid in HMI V1.0 System)|(% style="width:452px" %)Volume range: 0~~80 145 145 |=(% style="width: 160px;" %)HSW3|(% style="width:282px" %)Beep time|(% style="width:452px" %)Unit: ms 146 146 |=(% style="width: 160px;" %)HSW4|(% style="width:282px" %)Beep whether enable or not|(% style="width:452px" %)((( 147 147 * =0: Enable. ... ... @@ -180,12 +180,16 @@ 180 180 * =5: Friday. 181 181 * =6: Saturday. 182 182 ))) 192 +|=(% style="width: 160px;" %)HSW39|(% style="width:282px" %)Beep type(Only valid in HMI V2.0 System)|(% style="width:452px" %)Type range: 1-5, Default is 1. 183 183 |=(% style="width: 160px;" %)HSW134|(% style="width:282px" %)((( 184 184 Whether the Script is read through 185 185 186 186 187 187 )))|(% style="width:452px" %)((( 198 +(% class="box infomessage" %) 199 +((( 188 188 **✎Note:** If want to read-only or write-only, please enable this settings. 201 +))) 189 189 190 190 * =0: Read from HMI cache(Default) 191 191 * =1: Read from PLC directly ... ... @@ -296,7 +296,7 @@ 296 296 * =2: Ejecting SD card, please waiting… 297 297 * =3: SD card ejected 298 298 ))) 299 -|=(% style="width: 160px;" %)HSW550~~849|(% style="width:282px" %)Communication control|(% style="width:452px" %)For communication control and communication lamp (please refer to "[[ communication control>>http://13.229.109.52:8080/wiki/pistudio/view/Helps/13.HMI%20internal%20registers/#HCommunicationcontrol]]" sector for detailed)312 +|=(% style="width: 160px;" %)HSW550~~849|(% style="width:282px" %)Communication control|(% style="width:452px" %)For communication control and communication lamp (please refer to "[[Communication control>>https://docs.we-con.com.cn/bin/view/PIStudio/13.HMI%20internal%20registers/#HCommunicationcontrol]]" sector for detailed) 300 300 |=(% style="width: 160px;" %)HSW850|(% style="width:282px" %)((( 301 301 Network state 302 302 ... ... @@ -345,15 +345,15 @@ 345 345 * HDX882.1=1 SD card is reading data, don't remove SD card. 346 346 ))) 347 347 |=(% style="width: 160px;" %)HSW884|(% style="width:282px" %)Enter the system network configuration interface|(% style="width:452px" %)((( 348 -* =0: Do not enter the network configuration interface 349 -* =1: Enter the system network configuration interface. 361 +* = 0: Do not enter the network configuration interface 362 +* = 1: Enter the system network configuration interface. 350 350 ** ig series HMI only supports to enter the system interface 351 351 352 352 ))) 353 353 |=(% style="width: 160px;" %)HSW885|(% style="width:282px" %)When the control object hides the address is read failed (communication failure), set the display mode of the object|(% style="width:452px" %)((( 354 354 * = 0: displayed by object setting. 355 -* =1: control address read failure, the address control of all objects is hidden, not displayed. 356 -* =2: control address read failure, the address control of all objects is displayed, not hidden. 368 +* = 1: control address read failure, the address control of all objects is hidden, not displayed. 369 +* = 2: control address read failure, the address control of all objects is displayed, not hidden. 357 357 ))) 358 358 |=(% style="width: 160px;" %)HSW893|(% style="width:282px" %)((( 359 359 User Permission Control Address, same as HUW1000 feature, please refer to chapter "[[User Permission>>http://13.229.109.52:8080/wiki/pistudio/view/Helps/08.Basic%20Function/#HUserPermission]]" ... ... @@ -376,7 +376,7 @@ 376 376 |=(% style="width: 160px;" %)HSW900|(% style="width:282px" %)Quick update frequency settings for objects|(% style="width:452px" %)((( 377 377 Valid when the object is enabled for "quick update". Default: 5. 378 378 379 -Range: 1 (fastest) ~~50 (slowest)392 +Range: 1 (fastest) - 50 (slowest) 380 380 ))) 381 381 |=(% style="width: 160px;" %)HSW920|(% style="width:282px" %)Static mode Maximum periods|(% style="width:452px" %)Numeric Input/ Display (range: 0-12) 382 382 |=(% style="width: 160px;" %)HSW921 ~~ 924|(% style="width:282px" %)Static mode Admin key|(% style="width:452px" %)Character Input/ Display (length: 8) ... ... @@ -426,8 +426,11 @@ 426 426 |=(% style="width: 160px;" %)HSW1070|(% style="width:282px" %)The time interval (seconds) since the last time the screen was clicked|(% style="width:452px" %)((( 427 427 Shows how long the current screen has not been clicked, using a decimal unsigned double word (Numeric Input/ Display). 428 428 442 +(% class="box infomessage" %) 443 +((( 429 429 **✎Note: **This register is cleared to zero regardless of which user clicks on the screen. 430 430 ))) 446 +))) 431 431 |=(% style="width: 160px;" %)HSW1073|(% style="width:282px" %)Corresponding key value from keyboard|(% style="width:452px" %)Display the key value of the currently pressed key, the key value is shown in Table 1 (not updated when the character input display is being input) 432 432 |=(% style="width: 160px;" %)HSW1074|(% style="width:282px" %)Keyboard key status|(% style="width:452px" %)Display the current button status (not updated when the numeric input display is being input)((( 433 433 * =0: key release ... ... @@ -906,6 +906,41 @@ 906 906 * =2, trigger clear cache of all screens for once time 907 907 * =3, always clear cache of all screen data 908 908 ))) 925 +|=(% style="width: 160px;" %)HSW1892|(% colspan="1" style="width:282px" %)Keyboard key polling interval setting|(% style="width:452px" %)((( 926 +~=0,50ms; 927 + 928 +~=1,40ms; 929 + 930 +~=2,30ms; 931 + 932 +~=3,20ms; 933 + 934 +~=4,10ms; 935 +))) 936 +|=(% style="width: 160px;" %)HSW1893|(% colspan="1" style="width:282px" %)Cursor mode switch|(% style="width:452px" %)((( 937 +~=0, default free mode; 938 + 939 +~=1, selected box mode; 940 + 941 +~=2, selected gray mode; 942 + 943 +~=3, mouse selected mode; 944 +))) 945 +|=(% style="width: 160px;" %)HSW1894|(% colspan="1" style="width:282px" %)Enable a specific serial keyboard|(% style="width:452px" %)((( 946 +~=1 Enable; 947 + 948 +~=Other, not enabled; 949 + 950 +Note: Only valid for initialization, recommended to use in background initialization script; 951 +))) 952 +|=(% style="width: 160px;" %)HSW1895|(% colspan="1" style="width:282px" %)Controls whether keyboard keys are effective in certain situations|(% style="width:452px" %)((( 953 +~=0, by default, the key trigger does not take effect when the screen is off or in screen saver mode; 954 + 955 +~=1, HSX1895.0=1, the key trigger will also take effect when the screen is off; 956 + 957 +~=2, HSX1895.1=1, the key trigger will also take effect in screen saver mode; 958 +))) 959 +|=(% style="width: 160px;" %)HSW1903|(% colspan="1" style="width:282px" %)Check the network cable connection status|(% style="width:452px" %)If a network cable is detected, it is set to 1; if no network cable is detected, it is set to 0 909 909 |=(% style="width: 160px;" %)HSW10000~~19999|(% style="width:282px" %)Power-down storage area|(% style="width:452px" %)After restart, the data remains 910 910 |=(% style="width: 160px;" %)HSW10035|(% rowspan="13" style="width:282px" %)((( 911 911 Note: Valid when Ethernet1 of HMI is plugged into the network cable. ... ... @@ -977,7 +977,7 @@ 977 977 |=(% style="width: 160px;" %)HSW10606|(% style="width:282px" %)Printer instruction type|(% style="width:452px" %)((( 978 978 * =1: Graphic print type 979 979 * =2: Dot density printing type 980 -* =3: special for EPSON printer 1031 +* =3(Default value): special for EPSON printer 981 981 ))) 982 982 |=(% style="width: 160px;" %)HSW10607|(% style="width:282px" %)Printer paper cutting function|(% style="width:452px" %)((( 983 983 * =1: Enable ... ... @@ -988,7 +988,7 @@ 988 988 * =2: Center alignment 989 989 * =3: Right alignment 990 990 ))) 991 -|=(% style="width: 160px;" %)HSW1061 0|(% style="width:282px" %)Set weconcloud server|(% style="width:452px" %)(((1042 +|=(% style="width: 160px;" %)HSW10611|(% style="width:282px" %)Set weconcloud server|(% style="width:452px" %)((( 992 992 * =0: Select the server configured in "Project Settings" 993 993 * =1: select Server 1 994 994 * =2: select Server 2 ... ... @@ -998,6 +998,12 @@ 998 998 * =1: English 999 999 * =2: Chinese 1000 1000 ))) 1052 +|=(% style="width: 160px;" %)HSW11752|(% style="width:282px" %)Traffic monitoring control|(% style="width:452px" %)= 1: Enable the flow monitoring function 1053 +~= Other: Disable the flow monitoring function 1054 +|=(% style="width: 160px;" %)HSW11753|(% style="width:282px" %)Traffic monitoring network card type|(% style="width:452px" %)= 0: Ethernet card 1055 +~= 1: 4G 1056 +~= 2: Wi-Fi 1057 +|=(% style="width: 160px;" %)HSW11754-11755|(% style="width:282px" %)Historical traffic consumption|(% style="width:452px" %)The total traffic consumed historically (bytes) [value is an integer] 1001 1001 |=(% style="width: 160px;" %)HSW11756|(% style="width:282px" %)((( 1002 1002 Access permission restrictions 1003 1003 ... ... @@ -1006,6 +1006,7 @@ 1006 1006 * =0: LAN or the external network both OK 1007 1007 * =1: Only LAN access 1008 1008 * =2: Only external network can access 1066 +* =3: Close the functions 1009 1009 ))) 1010 1010 |=(% style="width: 160px;" %)HSW11757|(% style="width:282px" %)Enable the valid date of the dynamic installment password|(% style="width:452px" %)((( 1011 1011 * =0: Disabled ... ... @@ -1047,7 +1047,17 @@ 1047 1047 )))|(% style="width:452px" %)((( 1048 1048 ~=0: Raster,=1: Blinds,=2: Bubble 1049 1049 ))) 1108 +|=(% style="width: 160px;" %)HSW11767|(% style="width:282px" %)Remote screen display adaptation mode switching|(% style="width:452px" %)=0, default mode, remote full-screen zoom display for horizontal screen projects, remote proportional zoom display for vertical screen projects; 1109 +~=1, full-screen zoom display; 1110 +~=2, proportional zoom display according to screen size ratio; 1111 +~=3, no zoom display according to screen pixels; 1112 +|=(% style="width: 160px;" %)HSW11773|(% style="width:282px" %)Automatically log out user control address|(% style="width:452px" %)=3: that is, HSX11773.0=1, HSX11773.1=1, based on the configuration in the address, enable automatic user logout. 1113 +|=(% style="width: 160px;" %)HSW11774|(% style="width:282px" %)Automatic user logout interval|(% style="width:452px" %)((( 1114 +Range: 1 to 255 1050 1050 1116 +Unit: Minutes 1117 +))) 1118 + 1051 1051 == Serial port communication configuration == 1052 1052 1053 1053 (% class="table-bordered" %)