Changes for page 13 HMI Internal Registers
Last modified by Jett on 2025/04/28 16:07
Summary
-
Page properties (3 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 1 removed)
Details
- Page properties
-
- Title
-
... ... @@ -1,1 +1,1 @@ 1 -1 3.HMIInternalRegisters1 +12 HMI internal registers - Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Mora1 +XWiki.Hunter - Content
-
... ... @@ -25,11 +25,6 @@ 25 25 * The address of the bit address HDX is with a decimal point while word addresses are integers. 26 26 ))) 27 27 28 -= Address ranges table = 29 - 30 -(% style="text-align:center" %) 31 -[[image:6.png]] 32 - 33 33 = **Data storage area (HDW/HDX)** = 34 34 35 35 It is used to save the temporary data of project. ... ... @@ -65,8 +65,8 @@ 65 65 66 66 It is used for system special registers (reserved by system). 67 67 68 -1. Access as word, and serial number range is from HUW0 to HUW1 599.69 -1. Access as bit, and serial number range is from HUX0.0 to HUX1 599.15.63 +1. Access as word, and serial number range is from HUW0 to HUW199999. 64 +1. Access as bit, and serial number range is from HUX0.0 to HUX199999.15. 70 70 71 71 **✎Note:** 72 72 ... ... @@ -140,8 +140,8 @@ 140 140 (% class="table-bordered" style="width:1024px" %) 141 141 |=(% scope="row" style="width: 160px;" %)**Address**|=(% style="width: 282px;" %)**Function**|=(% style="width: 452px;" %)**Description** 142 142 |=(% style="width: 160px;" %)HSW0|(% style="width:282px" %)Language switch|(% style="width:452px" %)Multiple language could be set in the project, HMI support maximum 8 languages. (Power-down save supported) 143 -|=(% style="width: 160px;" %)HSW1|(% style="width:282px" %)Beep frequency (Only valid in HMI V1.0 System)|(% style="width:452px" %)Frequency range: 0~~4000144 -|=(% style="width: 160px;" %)HSW2|(% style="width:282px" %)Beep volume (Only valid in HMI V1.0 System)|(% style="width:452px" %)Volume range: 0~~80138 +|=(% style="width: 160px;" %)HSW1|(% style="width:282px" %)Beep frequency|(% style="width:452px" %)Frequency range: 0~~4000 139 +|=(% style="width: 160px;" %)HSW2|(% style="width:282px" %)Beep volume|(% style="width:452px" %)Volume range: 0~~80 145 145 |=(% style="width: 160px;" %)HSW3|(% style="width:282px" %)Beep time|(% style="width:452px" %)Unit: ms 146 146 |=(% style="width: 160px;" %)HSW4|(% style="width:282px" %)Beep whether enable or not|(% style="width:452px" %)((( 147 147 * =0: Enable. ... ... @@ -155,7 +155,7 @@ 155 155 ))) 156 156 |=(% style="width: 160px;" %)HSW6~~HSW7|(% style="width:282px" %)Number of alarms|(% style="width:452px" %)The number of alarm (it also includes the records of alarm confirmed) 157 157 |=(% style="width: 160px;" %)HSW8|(% style="width:282px" %)Number of unconfirmed history alarm|(% style="width:452px" %)The number of unconfirmed history alarm 158 -|=(% style="width: 160px;" %)HSW9|(% style="width:282px" %)Time out prompt|(% style="width:452px" %)(((153 +|=(% style="width: 160px;" %)HSW9|(% style="width:282px" %)Time out tip|(% style="width:452px" %)((( 159 159 * =0: Enable 160 160 * =1: Disable 161 161 ))) ... ... @@ -180,7 +180,6 @@ 180 180 * =5: Friday. 181 181 * =6: Saturday. 182 182 ))) 183 -|=(% style="width: 160px;" %)HSW39|(% style="width:282px" %)Beep type(Only valid in HMI V2.0 System)|(% style="width:452px" %) 184 184 |=(% style="width: 160px;" %)HSW134|(% style="width:282px" %)((( 185 185 Whether the Script is read through 186 186 ... ... @@ -456,7 +456,7 @@ 456 456 Address mapping polling cycle, effective range: 40~~1000ms, default: 300ms. 457 457 458 458 * When the set value is greater than 1000, the value is 1000. 459 -* When the set value is lower than40, it changes to the default value 300453 +* When the set value is greater than 1000, it changes to the default value 300 460 460 ))) 461 461 |=(% style="width: 160px;" %)HSW1087|(% style="width:282px" %)Control write interval in address mapping|(% style="width:452px" %)((( 462 462 After reading data to the device for N times, Perform an address mapping write operation. N is the interval value. The effective range: 0~~5, and default is 2. ... ... @@ -910,10 +910,10 @@ 910 910 |=(% style="width: 160px;" %)HSW10000~~19999|(% style="width:282px" %)Power-down storage area|(% style="width:452px" %)After restart, the data remains 911 911 |=(% style="width: 160px;" %)HSW10035|(% rowspan="13" style="width:282px" %)((( 912 912 Note: Valid when Ethernet1 of HMI is plugged into the network cable. 913 -① 914 -② When the Ethernet setting is not enabled in the engineering parameters, the register displays the Ethernet IP automatically acquired by the HMI. 915 -③ When the HMI is not plugged into the network cable, the register will show 0 whether the engineering parameters are set or not. 916 -④ 907 +①、When the Ethernet setting is enabled in the project parameters, this register displays the set value. 908 +②. When the Ethernet setting is not enabled in the engineering parameters, the register displays the Ethernet IP automatically acquired by the HMI. 909 +③. When the HMI is not plugged into the network cable, the register will show 0 whether the engineering parameters are set or not. 910 +④.IP related registers can be read and written (only static IP mode can be written). 917 917 )))|(% style="width:452px" %)Local IP address high byte 1 918 918 |=(% style="width: 160px;" %)HSW10036|(% style="width:452px" %)Local IP address high byte 2 919 919 |=(% style="width: 160px;" %)HSW10037|(% style="width:452px" %)Local IP address high byte 3
- 6.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Mora - Size
-
... ... @@ -1,1 +1,0 @@ 1 -20.1 KB - Content