... ... @@ -4,11 +4,11 @@
4 4  
5 5  *HSW, HDW, HUW, HAW are word address, HSX, HDX, HUX, HAX are bit address.
6 6  
7 -1. **System data area (HSW): **A special register defined by the system.
8 -1. **Data storage area (HDW/HDX): **Users store user data.
9 -1. **System data area (HUW): **A special register defined by the system.
10 -1. **System Data (HAW)**: System register used for power-off save.
11 -1. **Recipe index area (RPW): **System register used for recipe index.
7 +* **System data area (HSW): **A special register defined by the system.
8 +* **Data storage area (HDW/HDX): **Users store user data.
9 +* **System data area (HUW): **A special register defined by the system.
10 +* **System Data (HAW)**: System register used for power-off save.
11 +* **Recipe index area (RPW): **System register used for recipe index.
12 12  
13 13  HMI internal registers are divided into bit address and word address, which can be accessed in two ways (take HDW as an example).
14 14  
... ... @@ -339,9 +339,11 @@
339 339  * HDX882.1=0 SD card doesn't execute storage or storage finished.
340 340  * HDX882.1=1 SD card is reading data, don't remove SD card.
341 341  )))
342 -|=(% style="width: 160px;" %)HSW884|(% style="width:282px" %)Enter setup screen|(% style="width:452px" %)(((
343 -* = 0: Do not into setup screen
344 -* = 1: Enter setup screen
342 +|=(% style="width: 160px;" %)HSW884|(% style="width:282px" %)Enter the system network configuration interface|(% style="width:452px" %)(((
343 +* =0: Do not enter the network configuration interface
344 +* =1: Enter the system network configuration interface.
345 +** ig series HMI only supports to enter the system interface
346 +
345 345  )))
346 346  |=(% style="width: 160px;" %)HSW885|(% style="width:282px" %)When the control object hides the address is read failed (communication failure), set the display mode of the object|(% style="width:452px" %)(((
347 347  * = 0: displayed by object setting.
... ... @@ -510,6 +510,10 @@
510 510  * HSX1502.0=1: Modification comfirmed. Save the data of HSW1450~~HSW1501 to a file for immediate effect.
511 511  * HSX1502.1=1:Modification cancelled. Restore the current data of hSW1450-HSW1501 to the data saved in the file last time.
512 512  )))
515 +|=(% style="width: 160px;" %)HSW1509|(% style="width:282px" %)Curve width|(% style="width:452px" %)(((
516 +* =0: Use the curve width set by project default.
517 +* =1 to 10: use special register to set curve width.
518 +)))
513 513  |=(% style="width: 160px;" %)HSW1603|(% style="width:282px" %)Number of current unreleased alarms|(% style="width:452px" %)The number of current unreleased alarms in alarm record file.
514 514  |=(% style="width: 160px;" %)HSW1604|(% style="width:282px" %)The auxiliary judgment address when the control bit in the Object Lock fails to be read|(% style="width:452px" %)(((
515 515  * =0: The auxiliary address is invalid.
... ... @@ -612,6 +612,174 @@
612 612  * =1: Server connection is OK
613 613  )))
614 614  |=(% style="width: 160px;" %)HSW1761|(% style="width:282px" %)Display 4G network signal strength|(% style="width:452px" %)Signal strength: 0~~31. The greater the value ,the signal is stronger
621 +|=(% style="width: 160px;" %)(((
622 +HSW1762
623 +)))|(% colspan="1" rowspan="13" style="width:282px" %)(((
624 +Note: Valid when Ethernet2 of HMI is plugged into the network cable.
625 +①、When the Ethernet setting is enabled in the project parameters, this register displays the set value.
626 +②. When the Ethernet setting is not enabled in the engineering parameters, the register displays the Ethernet IP automatically acquired by the HMI.
627 +③. When the HMI is not plugged into the network cable, the register will show 0 whether the engineering parameters are set or not.
628 +④.IP related registers can be read and written (only static IP mode can be written).
629 +)))|(% style="width:452px" %)(((
630 +Ethernet2 Local IP address high byte 1
631 +)))
632 +|=(% style="width: 160px;" %)(((
633 +HSW1763
634 +)))|(% style="width:452px" %)(((
635 +Ethernet2 Local IP address high byte 2
636 +)))
637 +|=(% style="width: 160px;" %)(((
638 +HSW1764
639 +)))|(% style="width:452px" %)(((
640 +Ethernet2 Local IP address high byte 3
641 +)))
642 +|=(% style="width: 160px;" %)(((
643 +HSW1765
644 +)))|(% style="width:452px" %)(((
645 +Ethernet2 Local IP address high byte 4
646 +)))
647 +|=(% style="width: 160px;" %)(((
648 +HSW1766
649 +)))|(% style="width:452px" %)(((
650 +Ethernet2 Local mask IP address high byte 1
651 +)))
652 +|=(% style="width: 160px;" %)(((
653 +HSW1767
654 +)))|(% style="width:452px" %)(((
655 +Ethernet2 Local mask IP address high byte 2
656 +)))
657 +|=(% style="width: 160px;" %)(((
658 +HSW1768
659 +)))|(% style="width:452px" %)Ethernet2 Local mask IP address high byte 3
660 +|=(% style="width: 160px;" %)HSW1769|(% style="width:452px" %)Ethernet2 Local mask IP address high byte 4
661 +|=(% style="width: 160px;" %)(((
662 +HSW1770
663 +)))|(% style="width:452px" %)(((
664 +Ethernet2 Local gateway IP address high byte 1
665 +)))
666 +|=(% style="width: 160px;" %)(((
667 +HSW1771
668 +)))|(% style="width:452px" %)(((
669 +Ethernet2 Local gateway IP address high byte 2
670 +)))
671 +|=(% style="width: 160px;" %)(((
672 +HSW1772
673 +)))|(% style="width:452px" %)(((
674 +Ethernet2 Local gateway IP address high byte 3
675 +)))
676 +|=(% style="width: 160px;" %)(((
677 +HSW1773
678 +)))|(% style="width:452px" %)(((
679 +Ethernet2 Local gateway IP address high byte 4
680 +)))
681 +|=(% style="width: 160px;" %)(((
682 +HSW1774
683 +)))|(% style="width:452px" %)(((
684 +Ethernet2 Local Port Address
685 +)))
686 +|=(% style="width: 160px;" %)(((
687 +HSW1775
688 +)))|(% colspan="1" rowspan="6" style="width:282px" %)(((
689 +①Display the MAC code of Ethernet2 NIC
690 +
691 +(hexadecimal display)
692 +
693 +②Read-only mode, not modifiable
694 +)))|(% style="width:452px" %)(((
695 +Ethernet2 Local MAC code high byte 1
696 +)))
697 +|=(% style="width: 160px;" %)(((
698 +HSW1776
699 +)))|(% style="width:452px" %)(((
700 +Ethernet2 Local MAC code high byte 2
701 +)))
702 +|=(% style="width: 160px;" %)(((
703 +HSW1777
704 +)))|(% style="width:452px" %)(((
705 +Ethernet2 Local MAC code high byte 3
706 +)))
707 +|=(% style="width: 160px;" %)(((
708 +HSW1778
709 +)))|(% style="width:452px" %)(((
710 +Ethernet2 Local MAC code high byte 4
711 +)))
712 +|=(% style="width: 160px;" %)(((
713 +HSW1779
714 +)))|(% style="width:452px" %)(((
715 +Ethernet2 Local MAC code high byte 5
716 +)))
717 +|=(% style="width: 160px;" %)(((
718 +HSW1780
719 +)))|(% style="width:452px" %)(((
720 +Ethernet2 Local MAC code high byte 6
721 +)))
722 +|=(% style="width: 160px;" %)(((
723 +HSW1781
724 +)))|(% colspan="1" rowspan="8" style="width:282px" %)(((
725 +①Display and modify DNS1 and DNS2 of Ethernet2
726 +
727 +②Related registers can be read and written mode (only static IP mode can be written)
728 +)))|(% style="width:452px" %)(((
729 +Ethernet2 Local DNS1 address high byte 1
730 +)))
731 +|=(% style="width: 160px;" %)(((
732 +HSW1782
733 +)))|(% style="width:452px" %)(((
734 +Ethernet2 Local DNS1 address high byte 2
735 +)))
736 +|=(% style="width: 160px;" %)(((
737 +HSW1783
738 +)))|(% style="width:452px" %)(((
739 +Ethernet2 Local DNS1 address high byte 3
740 +)))
741 +|=(% style="width: 160px;" %)(((
742 +HSW1784
743 +)))|(% style="width:452px" %)(((
744 +Ethernet2 Local DNS1 address high byte 4
745 +)))
746 +|=(% style="width: 160px;" %)(((
747 +HSW1785
748 +)))|(% style="width:452px" %)(((
749 +Ethernet2 Local DNS2 address high byte 1
750 +)))
751 +|=(% style="width: 160px;" %)(((
752 +HSW1786
753 +)))|(% style="width:452px" %)(((
754 +Ethernet2 Local DNS2 address high byte 2
755 +)))
756 +|=(% style="width: 160px;" %)(((
757 +HSW1787
758 +)))|(% style="width:452px" %)(((
759 +Ethernet2 Local DNS2 address high byte 3
760 +)))
761 +|=(% style="width: 160px;" %)(((
762 +HSW1788
763 +)))|(% style="width:452px" %)(((
764 +Ethernet2 Local DNS2 address high byte 4
765 +)))
766 +|=(% style="width: 160px;" %)(((
767 +HSW1789
768 +)))|(% colspan="1" style="width:282px" %)(((
769 +Display or set the dynamic or static IP mode of Ethernet2
770 +)))|(% style="width:452px" %)(((
771 +HSX1789.0 = 0, Static IP mode
772 +
773 +HSX1789.0 = 1, dynamic IP mode
774 +)))
775 +|=(% style="width: 160px;" %)(((
776 +HSW1790
777 +)))|(% colspan="1" style="width:282px" %)(((
778 +Confirm Ethernet2 IP, subnet mask, gateway, DNS1, DNS2, and dynamic static IP settings
779 +)))|(% style="width:452px" %)(((
780 +~= 1, confirm the setting (i.e., after modifying IP-related information, set this address to 1, representing confirmation of the modification, after which it will be reset to 0)
781 +)))
782 +|=(% style="width: 160px;" %)(((
783 +HSW1791
784 +)))|(% colspan="1" style="width:282px" %)(((
785 +Network status of the Ethernet2 connection server
786 +)))|(% style="width:452px" %)(((
787 +~= 0, connection to the server is abnormal = 1, connection to the server is normal
788 +)))
615 615  |=(% style="width: 160px;" %)HSW1852|(% style="width:282px" %)Control the interval in two consecutive clicks|(% style="width:452px" %)Limit range: 1~~500ms. The default is 100 ms.
616 616  |=(% style="width: 160px;" %)HSW1853|(% style="width:282px" %)File format for exporting data records to USB flash drive or SD card|(% style="width:452px" %)(((
617 617  * =0: db database
... ... @@ -637,14 +637,80 @@
637 637  * =1: download firmware
638 638  * =2: enter the background
639 639  )))
814 +|=(% style="width: 160px;" %)HSW1865|(% style="width:282px" %)Priority connection to the cloud|(% style="width:452px" %)(((
815 +* =0: priority Ethernet
816 +* =1: priority WLAN
817 +* =2: priority 4G
818 +)))
819 +|=(% style="width: 160px;" %)HSW1866|(% style="width:282px" %)Delete the LUa extension module file|(% style="width:452px" %)(((
820 +* =0: delete;
821 +* = Others: do not delete
822 +)))
823 +|=(% style="width: 160px;" %)HSW1867|(% style="width:282px" %)Reset mode|(% style="width:452px" %)(((
824 +Monitor address is set during reset of reset switch, whether to cancel reset,
825 +
826 +* = 0: yes (default);
827 +* = 1: no
828 +)))
829 +|=(% style="width: 160px;" %)HSW1868|(% style="width:282px" %)Double-click or long press the record type table mode|(% style="width:452px" %)(((
830 +Controls whether the button pops up when double-clicking or long pressing on record type table object
831 +
832 +* = 0: yes (default);
833 +* = 1: no
834 +)))
835 +|=(% style="width: 160px;" %)(((
836 +HSW1870
837 +)))|(% style="width:282px" %)(((
838 +Display or set the dynamic or static IP mode of Ethernet1
839 +)))|(% style="width:452px" %)(((
840 +HSX1870.0 = 0, Static IP mode
841 +
842 +HSX1870.0 = 1, dynamic IP mode
843 +)))
844 +|=(% style="width: 160px;" %)(((
845 +HSW1871
846 +)))|(% style="width:282px" %)(((
847 +Confirm the IP, subnet mask, gateway, DNS1, DNS2, and dynamic static IP settings for Ethernet1
848 +)))|(% style="width:452px" %)(((
849 +~= 1, confirm the setting (i.e., after modifying IP-related information, set this address to 1, representing confirmation of the modification, after which it will be reset to 0)
850 +)))
851 +|=(% style="width: 160px;" %)(((
852 +HSW1872
853 +)))|(% colspan="1" rowspan="8" style="width:282px" %)(((
854 +①Display and modify DNS1 and DNS2 of Ethernet1
855 +
856 +②Related registers can be read and written mode (only static IP mode can be written)
857 +)))|(% style="width:452px" %)(((
858 +Ethernet1 Local DNS1 address high byte 1
859 +)))
860 +|=(% style="width: 160px;" %)(((
861 +HSW1873
862 +)))|(% style="width:452px" %)Ethernet1 Local DNS1 address high byte 2
863 +|=(% style="width: 160px;" %)(((
864 +HSW1874
865 +)))|(% style="width:452px" %)Ethernet1 Local DNS1 address high byte 3
866 +|=(% style="width: 160px;" %)(((
867 +HSW1875
868 +)))|(% style="width:452px" %)Ethernet1 Local DNS1 address high byte 4
869 +|=(% style="width: 160px;" %)(((
870 +HSW1876
871 +)))|(% style="width:452px" %)Ethernet1 Local DNS2 address high byte 1
872 +|=(% style="width: 160px;" %)(((
873 +HSW1877
874 +)))|(% style="width:452px" %)Ethernet1 Local DNS2 address high byte 2
875 +|=(% style="width: 160px;" %)(((
876 +HSW1878
877 +)))|(% style="width:452px" %)Ethernet1 Local DNS2 address high byte 3
878 +|=(% style="width: 160px;" %)(((
879 +HSW1879
880 +)))|(% style="width:452px" %)Ethernet1 Local DNS2 address high byte 4
640 640  |=(% style="width: 160px;" %)HSW10000~~19999|(% style="width:282px" %)Power-down storage area|(% style="width:452px" %)After restart, the data remains
641 641  |=(% style="width: 160px;" %)HSW10035|(% rowspan="13" style="width:282px" %)(((
642 -**✎Note: **Only valid when the HMI is plugged into the Ethernet cable.
643 -
644 -1. If Ethernet settings is enabled in project parameters, this register displays the set value.
645 -1. If Ethernet settings is not enabled in project parameters, IP would automatically obtained IP.
646 -1. If HMI is not connected to the network, the register is displayed as 0 whether the engineering parameters are set.
647 -1. 4. All IP registers of HMI are read-only.
883 +Note: Valid when Ethernet1 of HMI is plugged into the network cable.
884 +①、When the Ethernet setting is enabled in the project parameters, this register displays the set value.
885 +②. When the Ethernet setting is not enabled in the engineering parameters, the register displays the Ethernet IP automatically acquired by the HMI.
886 +③. When the HMI is not plugged into the network cable, the register will show 0 whether the engineering parameters are set or not.
887 +④.IP related registers can be read and written (only static IP mode can be written).
648 648  )))|(% style="width:452px" %)Local IP address high byte 1
649 649  |=(% style="width: 160px;" %)HSW10036|(% style="width:452px" %)Local IP address high byte 2
650 650  |=(% style="width: 160px;" %)HSW10037|(% style="width:452px" %)Local IP address high byte 3
... ... @@ -659,9 +659,11 @@
659 659  |=(% style="width: 160px;" %)HSW10046|(% style="width:452px" %)Local gateway address high byte 4
660 660  |=(% style="width: 160px;" %)HSW10047|(% style="width:452px" %)Local port address
661 661  |=(% style="width: 160px;" %)HSW10048|(% rowspan="6" style="width:282px" %)(((
662 -Displays the MAC code of the current network card
902 +Display the MAC code of Ethernet1 NIC
663 663  
664 -(Hexadecimal display)
904 +(hexadecimal display)
905 +
906 +②Read-only mode, not modifiable
665 665  )))|(% style="width:452px" %)Local MAC code high word 1
666 666  |=(% style="width: 160px;" %)HSW10049|(% style="width:452px" %)Local MAC code high word 2
667 667  |=(% style="width: 160px;" %)HSW10050|(% style="width:452px" %)Local MAC code high word 3
... ... @@ -751,10 +751,10 @@
751 751  |=(% style="width: 160px;" %)HSW11760|(% style="width:282px" %)Screensaver countdown|(% style="width:452px" %)Display the countdown to enter the Screensaver, unit: second.
752 752  |=(% style="width: 160px;" %)HSW11761|(% style="width:282px" %)Screensaver screen number|(% style="width:452px" %)Set the screen number for Screensaver
753 753  
754 -== **Serial port communication configuration** ==
996 +== Serial port communication configuration ==
755 755  
756 756  (% class="table-bordered" %)
757 -|=(% style="width: 102px;" %)Port|=(% style="width: 173px;" %)**Function**|=(% style="width: 122px;" %)**Address**|=(% colspan="2" style="width: 506px;" %)**Description**
999 +|=(% scope="row" style="width: 102px;" %)Port|=(% style="width: 173px;" %)**Function**|=(% style="width: 122px;" %)**Address**|=(% colspan="2" style="width: 506px;" %)**Description**
758 758  |(% colspan="1" rowspan="11" style="width:102px" %)COM1|(% style="width:173px" %)Communication mode|(% style="width:122px" %)HSW10061|(% colspan="2" style="width:506px" %)(((
759 759  * =0: RS232
760 760  * =1: RS485
... ... @@ -784,10 +784,22 @@
784 784  * =1: ODD
785 785  * =2: EVEN
786 786  )))
787 -|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10066|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000
788 -|(% style="width:173px" %)reveive timeout|(% style="width:122px" %)HSW10067|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000
789 -|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10068|(% colspan="2" style="width:506px" %)Unit: times. Range: 0~~100
790 -|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10069|(% colspan="2" style="width:506px" %)Unit: s. Range: 0~~300
1029 +|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10066|(% colspan="2" style="width:506px" %)(((
1030 +* Unit: ms.
1031 +* Range: 0 to 30000
1032 +)))
1033 +|(% style="width:173px" %)reveive timeout|(% style="width:122px" %)HSW10067|(% colspan="2" style="width:506px" %)(((
1034 +* Unit: ms.
1035 +* Range: 0 to 30000
1036 +)))
1037 +|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10068|(% colspan="2" style="width:506px" %)(((
1038 +* Unit: times.
1039 +* Range: 0 to 100
1040 +)))
1041 +|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10069|(% colspan="2" style="width:506px" %)(((
1042 +* Unit: s.
1043 +* Range: 0 to 300
1044 +)))
791 791  |(% style="width:173px" %)HMI station number|(% style="width:122px" %)HSW10070|(% colspan="2" style="width:506px" %)
792 792  |(% style="width:173px" %)PLC station number|(% style="width:122px" %)HSW10071|(% colspan="2" style="width:506px" %)
793 793  |(% colspan="1" rowspan="11" style="width:102px" %)COM1-2|(% style="width:173px" %)Communication mode|(% style="width:122px" %)HSW10094|(% colspan="2" style="width:506px" %)(((
... ... @@ -820,10 +820,22 @@
820 820  * =1: ODD
821 821  * =2: EVEN
822 822  )))
823 -|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10099|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000
824 -|(% style="width:173px" %)receive timeout|(% style="width:122px" %)HSW10100|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000
825 -|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10101|(% colspan="2" style="width:506px" %)Unit: times. Range: 0~~100
826 -|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10102|(% colspan="2" style="width:506px" %)Unit: s. Range: 0~~30
1077 +|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10099|(% colspan="2" style="width:506px" %)(((
1078 +* Unit: ms.
1079 +* Range: 0 to 30000
1080 +)))
1081 +|(% style="width:173px" %)receive timeout|(% style="width:122px" %)HSW10100|(% colspan="2" style="width:506px" %)(((
1082 +* Unit: ms.
1083 +* Range: 0 to 30000
1084 +)))
1085 +|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10101|(% colspan="2" style="width:506px" %)(((
1086 +* Unit: times.
1087 +* Range: 0 to 100
1088 +)))
1089 +|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10102|(% colspan="2" style="width:506px" %)(((
1090 +* Unit: s.
1091 +* Range: 0 to 30
1092 +)))
827 827  |(% style="width:173px" %)HMI station number|(% style="width:122px" %)HSW10103|(% colspan="2" style="width:506px" %)
828 828  |(% style="width:173px" %)PLC station number|(% style="width:122px" %)HSW10104|(% colspan="2" style="width:506px" %)
829 829  |(% colspan="1" rowspan="11" style="width:102px" %)COM1-3|(% style="width:173px" %)Communication mode|(% style="width:122px" %)HSW10120|(% colspan="2" style="width:506px" %)(((
... ... @@ -856,10 +856,22 @@
856 856  * =1: ODD
857 857  * =2: EVEN
858 858  )))
859 -|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10125|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000
860 -|(% style="width:173px" %)receive timeout|(% style="width:122px" %)HSW10126|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000
861 -|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10127|(% colspan="2" style="width:506px" %)Unit: times. Range: 0~~100
862 -|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10128|(% colspan="2" style="width:506px" %)Unit: s. Range: 0~~30
1125 +|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10125|(% colspan="2" style="width:506px" %)(((
1126 +* Unit: ms.
1127 +* Range: 0 to 30000
1128 +)))
1129 +|(% style="width:173px" %)receive timeout|(% style="width:122px" %)HSW10126|(% colspan="2" style="width:506px" %)(((
1130 +* Unit: ms.
1131 +* Range: 0 to 30000
1132 +)))
1133 +|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10127|(% colspan="2" style="width:506px" %)(((
1134 +* Unit: times.
1135 +* Range: 0 to 100
1136 +)))
1137 +|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10128|(% colspan="2" style="width:506px" %)(((
1138 +* Unit: s.
1139 +* Range: 0 to 30
1140 +)))
863 863  |(% style="width:173px" %)HMI station number|(% style="width:122px" %)HSW10129|(% colspan="2" style="width:506px" %)
864 864  |(% style="width:173px" %)PLC station number|(% style="width:122px" %)HSW10130|(% colspan="2" style="width:506px" %)
865 865  |(% colspan="1" rowspan="11" style="width:102px" %)COM2|(% style="width:173px" %)Communication mode|(% style="width:122px" %)HSW10072|(% colspan="2" style="width:506px" %)(((
... ... @@ -890,10 +890,22 @@
890 890  * =1: ODD
891 891  * =2: EVEN
892 892  )))
893 -|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10077|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000
894 -|(% style="width:173px" %)receive timeout|(% style="width:122px" %)HSW10078|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000
895 -|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10079|(% colspan="2" style="width:506px" %)Unit: times. Range: 0~~100
896 -|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10080|(% colspan="2" style="width:506px" %)Unit: s. Range: 0~~30
1171 +|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10077|(% colspan="2" style="width:506px" %)(((
1172 +* Unit: ms.
1173 +* Range: 0 to 30000
1174 +)))
1175 +|(% style="width:173px" %)receive timeout|(% style="width:122px" %)HSW10078|(% colspan="2" style="width:506px" %)(((
1176 +* Unit: ms.
1177 +* Range: 0 to 30000
1178 +)))
1179 +|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10079|(% colspan="2" style="width:506px" %)(((
1180 +* Unit: times.
1181 +* Range: 0 to 100
1182 +)))
1183 +|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10080|(% colspan="2" style="width:506px" %)(((
1184 +* Unit: s.
1185 +* Range: 0 to 30
1186 +)))
897 897  |(% style="width:173px" %)HMI station number|(% style="width:122px" %)HSW10081|(% colspan="2" style="width:506px" %)
898 898  |(% style="width:173px" %)PLC station number|(% style="width:122px" %)HSW10082|(% colspan="2" style="width:506px" %)
899 899  |(% colspan="1" rowspan="11" style="width:102px" %)COM2-2|(% style="width:173px" %)Communication mode|(% style="width:122px" %)HSW10105|(% colspan="2" style="width:506px" %)(((
... ... @@ -924,10 +924,22 @@
924 924  * =1: ODD
925 925  * =2: EVEN
926 926  )))
927 -|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10110|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000
928 -|(% style="width:173px" %)receive timeout|(% style="width:122px" %)HSW10111|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000
929 -|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10112|(% colspan="2" style="width:506px" %)Unit: times. Range: 0~~100
930 -|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10113|(% colspan="2" style="width:506px" %)Unit: s. Range: 0~~30
1217 +|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10110|(% colspan="2" style="width:506px" %)(((
1218 +* Unit: ms.
1219 +* Range: 0 to 30000
1220 +)))
1221 +|(% style="width:173px" %)receive timeout|(% style="width:122px" %)HSW10111|(% colspan="2" style="width:506px" %)(((
1222 +* Unit: ms.
1223 +* Range: 0 to 30000
1224 +)))
1225 +|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10112|(% colspan="2" style="width:506px" %)(((
1226 +* Unit: times.
1227 +* Range: 0 to 100
1228 +)))
1229 +|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10113|(% colspan="2" style="width:506px" %)(((
1230 +* Unit: s.
1231 +* Range: 0 to 30
1232 +)))
931 931  |(% style="width:173px" %)HMI station number|(% style="width:122px" %)HSW10114|(% colspan="2" style="width:506px" %)
932 932  |(% style="width:173px" %)PLC station number|(% style="width:122px" %)HSW10115|(% colspan="2" style="width:506px" %)
933 933  |(% colspan="1" rowspan="11" style="width:102px" %)COM3|(% style="width:173px" %)Communication mode|(% style="width:122px" %)HSW10083|(% colspan="2" style="width:506px" %)(((
... ... @@ -957,29 +957,48 @@
957 957  * =1: ODD
958 958  * =2: EVEN
959 959  )))
960 -|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10088|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000
961 -|(% style="width:173px" %)receive timeout|(% style="width:122px" %)HSW10089|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000
962 -|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10090|(% colspan="2" style="width:506px" %)Unit: times. Range: 0~~100
963 -|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10091|(% colspan="2" style="width:506px" %)Unit: s. Range: 0~~30
1262 +|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10088|(% colspan="2" style="width:506px" %)(((
1263 +* Unit: ms.
1264 +* Range: 0 to 30000
1265 +)))
1266 +|(% style="width:173px" %)receive timeout|(% style="width:122px" %)HSW10089|(% colspan="2" style="width:506px" %)(((
1267 +* Unit: ms.
1268 +* Range: 0 to 30000
1269 +)))
1270 +|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10090|(% colspan="2" style="width:506px" %)(((
1271 +* Unit: times.
1272 +* Range: 0 to 100
1273 +)))
1274 +|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10091|(% colspan="2" style="width:506px" %)(((
1275 +* Unit: s.
1276 +* Range: 0 to 30
1277 +)))
964 964  |(% style="width:173px" %)HMI station number|(% style="width:122px" %)HSW10092|(% colspan="2" style="width:506px" %)
965 965  |(% style="width:173px" %)PLC station number|(% style="width:122px" %)HSW10093|(% colspan="2" style="width:506px" %)
966 966  |(% colspan="1" rowspan="2" style="width:102px" %)CAN port|(% style="width:173px" %)CAN1 baud rate|(% style="width:122px" %)HSW010116|(% style="width:299px" %)(((
967 -Unit: K, the baud rate must be an integer, for example, when the baud rate required is 250000, just enter 250.
1281 +Unit: K, the baud rate must be an integer.
1282 +
1283 +For example, when the baud rate required is 250000, just enter 250.
968 968  )))|(% colspan="1" rowspan="2" style="width:218px" %)**✎Note: **If baud rate has been modified,please wait 5 seconds,then restart the HMI to take effect.
969 -|(% style="width:173px" %)CAN2 baud rate|(% style="width:122px" %)HSW010117|(% style="width:299px" %)Unit: K, the baud rate must be an integer, for example, when the baud rate required is 250000, just enter 250.
1285 +|(% style="width:173px" %)CAN2 baud rate|(% style="width:122px" %)HSW010117|(% style="width:299px" %)(((
1286 +Unit: K, the baud rate must be an integer.
970 970  
971 -== **Ethernet communication configuration** ==
1288 +For example, when the baud rate required is 250000, just enter 250.
1289 +)))
972 972  
1291 +== Ethernet communication configuration ==
1292 +
973 973  (% class="table-bordered" %)
974 -|=(% style="width: 40px;" %)**No.**|=(% style="width: 295px;" %)**Function**|=(% style="width: 220px;" %)**Address**|=(% style="width: 336px;" %)**Description**
1294 +|(% style="width:40px" %)**No.**|(% style="width:295px" %)**Function**|(% style="width:220px" %)**Address**|(% style="width:336px" %)**Description**
975 975  |(% rowspan="7" style="width:40px" %)1|(% colspan="1" rowspan="7" style="width:295px" %)Ethernet parameter configuration for communication number 1 in list. Configure those addresses according to connected device. After configuration, wait for 5 seconds and restart the HMI.|(% style="width:220px" %)HSW11004|(% style="width:336px" %)Device IP address high word 1
976 976  |(% style="width:220px" %)HSW11005|(% style="width:336px" %)Device IP address high word 2
977 977  |(% style="width:220px" %)HSW11006|(% style="width:336px" %)Device IP address high word 3
978 978  |(% style="width:220px" %)HSW11007|(% style="width:336px" %)Device IP address high word 4
979 979  |(% style="width:220px" %)HSW11008|(% style="width:336px" %)Device Port number
980 -|(% style="width:220px" %)HSW11009|=(% style="width: 336px;" %)(((
981 -* =2 TCP
982 -* =3 UDP
1300 +|(% style="width:220px" %)HSW11009|(% style="width:336px" %)(((
1301 +~=2 TCP
1302 +
1303 +~=3 UDP
983 983  )))
984 984  |(% style="width:220px" %)HSW11010|(% style="width:336px" %)Reserved
985 985  |(% rowspan="7" style="width:40px" %)2|(% colspan="1" rowspan="7" style="width:295px" %)Ethernet parameter configuration for communication number 2 in list. Configure those addresses according to connected device. After configuration, wait for 5 seconds and restart the HMI.|(% style="width:220px" %)HSW11011|(% style="width:336px" %)Device IP address high word 1
... ... @@ -987,9 +987,10 @@
987 987  |(% style="width:220px" %)HSW11013|(% style="width:336px" %)Device IP address high word 3
988 988  |(% style="width:220px" %)HSW11014|(% style="width:336px" %)Device IP address high word 4
989 989  |(% style="width:220px" %)HSW11015|(% style="width:336px" %)Device Port number
990 -|(% style="width:220px" %)HSW11016|=(% style="width: 336px;" %)(((
991 -* =2 TCP
992 -* =3 UDP
1311 +|(% style="width:220px" %)HSW11016|(% style="width:336px" %)(((
1312 +~=2 TCP
1313 +
1314 +~=3 UDP
993 993  )))
994 994  |(% style="width:220px" %)HSW11017|(% style="width:336px" %)Reserved
995 995  |(% style="width:40px" %)…|(% style="width:295px" %) |(% style="width:220px" %)…|(% style="width:336px" %)…
... ... @@ -998,7 +998,11 @@
998 998  |(% style="width:220px" %)HSW11223|(% style="width:336px" %)Device IP address high word 3
999 999  |(% style="width:220px" %)HSW11224|(% style="width:336px" %)Device IP address high word 4
1000 1000  |(% style="width:220px" %)HSW11225|(% style="width:336px" %)Device Port number
1001 -|(% style="width:220px" %)HSW11226|=(% style="width: 336px;" %)2 TCP; =3 UDP
1323 +|(% style="width:220px" %)HSW11226|(% style="width:336px" %)(((
1324 +~=2 TCP;
1325 +
1326 +~=3 UDP
1327 +)))
1002 1002  |(% style="width:220px" %)HSW11227|(% style="width:336px" %)Reserved
1003 1003  
1004 1004  (% class="box infomessage" %)
... ... @@ -1006,10 +1006,10 @@
1006 1006  **✎Note:** The number of Ethernet connections supported by different HMI series varies.
1007 1007  )))
1008 1008  
1009 -== **Communication control** ==
1335 +== Communication control ==
1010 1010  
1011 1011  (% class="table-bordered" %)
1012 -|(% style="width:135px" %)**Communication No.**|(% style="width:102px" %)**Station No.**|(% style="width:185px" %)**Control bit**|(% style="width:191px" %)**Communication lamp**|(% style="width:271px" %)**Description**
1338 +|=(% style="width: 135px;" %)**Communication No.**|=(% style="width: 102px;" %)**Station No.**|=(% style="width: 185px;" %)**Control bit**|=(% style="width: 191px;" %)**Communication lamp**|=(% style="width: 271px;" %)**Description**
1013 1013  |(% colspan="1" rowspan="16" style="width:135px" %)1|(% style="width:102px" %)0~~15|(% style="width:185px" %)HSX550.0~HSX550.15|(% style="width:191px" %)HSX558.0~HSX558.15|(% rowspan="160" style="width:271px" %)Communication number refers to the number in "Communication Port Configuration". A number provides 256 device station numbers. Each station number corresponds to a communication control bit and a communication indicator bit. Registers HSX550.0 to HSX805.15 are used to control the station numbers from 0 to 127, and registers HSX1150.0 to HSX1405.15 are used to control station numbers 128 to 255.
1014 1014  |(% style="width:102px" %)16~~31|(% style="width:185px" %)HSX551.0~HSX551.15|(% style="width:191px" %)HSX559.0~HSX559.15
1015 1015  |(% style="width:102px" %)32~~47|(% style="width:185px" %)HSX552.0~HSX552.15|(% style="width:191px" %)HSX560.0~HSX560.15