Changes for page 13 HMI Internal Registers
Last modified by Jett on 2025/04/28 16:07
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -339,9 +339,11 @@ 339 339 * HDX882.1=0 SD card doesn't execute storage or storage finished. 340 340 * HDX882.1=1 SD card is reading data, don't remove SD card. 341 341 ))) 342 -|=(% style="width: 160px;" %)HSW884|(% style="width:282px" %)Enter setup screen|(% style="width:452px" %)((( 343 -* = 0: Do not into setup screen 344 -* = 1: Enter setup screen 342 +|=(% style="width: 160px;" %)HSW884|(% style="width:282px" %)Enter the system network configuration interface|(% style="width:452px" %)((( 343 +* =0: Do not enter the network configuration interface 344 +* =1: Enter the system network configuration interface. 345 +** ig series HMI only supports to enter the system interface 346 + 345 345 ))) 346 346 |=(% style="width: 160px;" %)HSW885|(% style="width:282px" %)When the control object hides the address is read failed (communication failure), set the display mode of the object|(% style="width:452px" %)((( 347 347 * = 0: displayed by object setting. ... ... @@ -510,6 +510,10 @@ 510 510 * HSX1502.0=1: Modification comfirmed. Save the data of HSW1450~~HSW1501 to a file for immediate effect. 511 511 * HSX1502.1=1:Modification cancelled. Restore the current data of hSW1450-HSW1501 to the data saved in the file last time. 512 512 ))) 515 +|=(% style="width: 160px;" %)HSW1509|(% style="width:282px" %)Curve width|(% style="width:452px" %)((( 516 +* =0: Use the curve width set by project default. 517 +* =1 to 10: use special register to set curve width. 518 +))) 513 513 |=(% style="width: 160px;" %)HSW1603|(% style="width:282px" %)Number of current unreleased alarms|(% style="width:452px" %)The number of current unreleased alarms in alarm record file. 514 514 |=(% style="width: 160px;" %)HSW1604|(% style="width:282px" %)The auxiliary judgment address when the control bit in the Object Lock fails to be read|(% style="width:452px" %)((( 515 515 * =0: The auxiliary address is invalid. ... ... @@ -1009,7 +1009,7 @@ 1009 1009 == **Communication control** == 1010 1010 1011 1011 (% class="table-bordered" %) 1012 -|(% style="width:135px" %)**Communication No.**|(% style="width:102px" %)**Station No.**|(% style="width:185px" %)**Control bit**|(% style="width:191px" %)**Communication lamp**|(% style="width:271px" %)**Description** 1018 +|=(% style="width: 135px;" %)**Communication No.**|=(% style="width: 102px;" %)**Station No.**|=(% style="width: 185px;" %)**Control bit**|=(% style="width: 191px;" %)**Communication lamp**|=(% style="width: 271px;" %)**Description** 1013 1013 |(% colspan="1" rowspan="16" style="width:135px" %)1|(% style="width:102px" %)0~~15|(% style="width:185px" %)HSX550.0~HSX550.15|(% style="width:191px" %)HSX558.0~HSX558.15|(% rowspan="160" style="width:271px" %)Communication number refers to the number in "Communication Port Configuration". A number provides 256 device station numbers. Each station number corresponds to a communication control bit and a communication indicator bit. Registers HSX550.0 to HSX805.15 are used to control the station numbers from 0 to 127, and registers HSX1150.0 to HSX1405.15 are used to control station numbers 128 to 255. 1014 1014 |(% style="width:102px" %)16~~31|(% style="width:185px" %)HSX551.0~HSX551.15|(% style="width:191px" %)HSX559.0~HSX559.15 1015 1015 |(% style="width:102px" %)32~~47|(% style="width:185px" %)HSX552.0~HSX552.15|(% style="width:191px" %)HSX560.0~HSX560.15