Changes for page 13 HMI Internal Registers
Last modified by Jett on 2025/04/28 16:07
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -56,10 +56,13 @@ 56 56 57 57 It is system recipe data power-off save register. The range is from RPW000000 to RPW990450. 58 58 59 +(% class="box infomessage" %) 60 +((( 59 59 **✎Note:** 60 60 61 61 * RPW is power-down retention. The register of this type is able to save the data before the power-down. 62 62 * To avoid possible device failure, do not immediately power off and reboot when configuring the power-down save addre 65 +))) 63 63 64 64 = **Single user data area (HUW/HUX)** = 65 65 ... ... @@ -68,9 +68,12 @@ 68 68 1. Access as word, and serial number range is from HUW0 to HUW1599. 69 69 1. Access as bit, and serial number range is from HUX0.0 to HUX1599.15. 70 70 74 +(% class="box infomessage" %) 75 +((( 71 71 **✎Note:** 72 72 73 73 * HUW/HUX is a system special register, so please check the system special register list during use. Please use the address specified in the table and do not use the address which is not mentioned in the table. 79 +))) 74 74 75 75 (% class="table-bordered" %) 76 76 |=**Special register address**|=**Description**|=**Function** ... ... @@ -132,10 +132,13 @@ 132 132 1. Access as word, and serial number range is from HSW0 to HSW49999. (HSW10000 to HSW19999 are the power-off storage areas) 133 133 1. Access as bit, and serial number range is from HSX0.0 to HSX49999.15. 134 134 141 +(% class="box infomessage" %) 142 +((( 135 135 **✎Note:** 136 136 137 137 * HSW / HSX are a system special register, so please check the system special register list during use. Please use the address specified in the table and do not use the address which is not mentioned in the table. 138 138 * To avoid possible device failure, do not immediately power off and reboot when configuring the power-down save address. 147 +))) 139 139 140 140 (% class="table-bordered" style="width:1024px" %) 141 141 |=(% scope="row" style="width: 160px;" %)**Address**|=(% style="width: 282px;" %)**Function**|=(% style="width: 452px;" %)**Description** ... ... @@ -186,7 +186,10 @@ 186 186 187 187 188 188 )))|(% style="width:452px" %)((( 198 +(% class="box infomessage" %) 199 +((( 189 189 **✎Note:** If want to read-only or write-only, please enable this settings. 201 +))) 190 190 191 191 * =0: Read from HMI cache(Default) 192 192 * =1: Read from PLC directly ... ... @@ -297,7 +297,7 @@ 297 297 * =2: Ejecting SD card, please waiting… 298 298 * =3: SD card ejected 299 299 ))) 300 -|=(% style="width: 160px;" %)HSW550~~849|(% style="width:282px" %)Communication control|(% style="width:452px" %)For communication control and communication lamp (please refer to "[[ communication control>>http://13.229.109.52:8080/wiki/pistudio/view/Helps/13.HMI%20internal%20registers/#HCommunicationcontrol]]" sector for detailed)312 +|=(% style="width: 160px;" %)HSW550~~849|(% style="width:282px" %)Communication control|(% style="width:452px" %)For communication control and communication lamp (please refer to "[[Communication control>>http://13.229.109.52:8080/wiki/pistudio/view/Helps/13.HMI%20internal%20registers/#HCommunicationcontrol]]" sector for detailed) 301 301 |=(% style="width: 160px;" %)HSW850|(% style="width:282px" %)((( 302 302 Network state 303 303 ... ... @@ -346,15 +346,15 @@ 346 346 * HDX882.1=1 SD card is reading data, don't remove SD card. 347 347 ))) 348 348 |=(% style="width: 160px;" %)HSW884|(% style="width:282px" %)Enter the system network configuration interface|(% style="width:452px" %)((( 349 -* =0: Do not enter the network configuration interface 350 -* =1: Enter the system network configuration interface. 361 +* = 0: Do not enter the network configuration interface 362 +* = 1: Enter the system network configuration interface. 351 351 ** ig series HMI only supports to enter the system interface 352 352 353 353 ))) 354 354 |=(% style="width: 160px;" %)HSW885|(% style="width:282px" %)When the control object hides the address is read failed (communication failure), set the display mode of the object|(% style="width:452px" %)((( 355 355 * = 0: displayed by object setting. 356 -* =1: control address read failure, the address control of all objects is hidden, not displayed. 357 -* =2: control address read failure, the address control of all objects is displayed, not hidden. 368 +* = 1: control address read failure, the address control of all objects is hidden, not displayed. 369 +* = 2: control address read failure, the address control of all objects is displayed, not hidden. 358 358 ))) 359 359 |=(% style="width: 160px;" %)HSW893|(% style="width:282px" %)((( 360 360 User Permission Control Address, same as HUW1000 feature, please refer to chapter "[[User Permission>>http://13.229.109.52:8080/wiki/pistudio/view/Helps/08.Basic%20Function/#HUserPermission]]" ... ... @@ -377,7 +377,7 @@ 377 377 |=(% style="width: 160px;" %)HSW900|(% style="width:282px" %)Quick update frequency settings for objects|(% style="width:452px" %)((( 378 378 Valid when the object is enabled for "quick update". Default: 5. 379 379 380 -Range: 1 (fastest) ~~50 (slowest)392 +Range: 1 (fastest) - 50 (slowest) 381 381 ))) 382 382 |=(% style="width: 160px;" %)HSW920|(% style="width:282px" %)Static mode Maximum periods|(% style="width:452px" %)Numeric Input/ Display (range: 0-12) 383 383 |=(% style="width: 160px;" %)HSW921 ~~ 924|(% style="width:282px" %)Static mode Admin key|(% style="width:452px" %)Character Input/ Display (length: 8) ... ... @@ -427,8 +427,11 @@ 427 427 |=(% style="width: 160px;" %)HSW1070|(% style="width:282px" %)The time interval (seconds) since the last time the screen was clicked|(% style="width:452px" %)((( 428 428 Shows how long the current screen has not been clicked, using a decimal unsigned double word (Numeric Input/ Display). 429 429 442 +(% class="box infomessage" %) 443 +((( 430 430 **✎Note: **This register is cleared to zero regardless of which user clicks on the screen. 431 431 ))) 446 +))) 432 432 |=(% style="width: 160px;" %)HSW1073|(% style="width:282px" %)Corresponding key value from keyboard|(% style="width:452px" %)Display the key value of the currently pressed key, the key value is shown in Table 1 (not updated when the character input display is being input) 433 433 |=(% style="width: 160px;" %)HSW1074|(% style="width:282px" %)Keyboard key status|(% style="width:452px" %)Display the current button status (not updated when the numeric input display is being input)((( 434 434 * =0: key release