Changes for page 13 HMI Internal Registers
Last modified by Jett on 2025/04/28 16:07
Summary
-
Page properties (3 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 1 removed)
Details
- Page properties
-
- Title
-
... ... @@ -1,1 +1,1 @@ 1 -1 3.HMIInternalRegisters1 +12 HMI internal registers - Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Mora1 +XWiki.Hunter - Content
-
... ... @@ -25,10 +25,20 @@ 25 25 * The address of the bit address HDX is with a decimal point while word addresses are integers. 26 26 ))) 27 27 28 +(% class="wikigeneratedid" %) 28 28 = Address ranges table = 29 29 30 -(% style="text-align:center" %) 31 -[[image:6.png]] 31 +|=(% scope="row" style="width: 206px;" %)Address Type\HMI Series|=(% style="width: 240px;" %)General Series|=(% style="width: 200px;" %)i Series/HMI+ models|=(% style="width: 136px;" %)ie Series|=(% style="width: 232px;" %)ig Series 32 +|=(% style="width: 206px;" %)HDW|HDW0-HDW299999|HDW0-HDW299999|HDW0-HDW299999|HDW0-HDW299999 33 +|=(% style="width: 206px;" %)HSW|HSW0-HSW14999|HSW0-HSW14999|HSW0-HSW14999|HSW0-HSW14999 34 +|=(% style="width: 206px;" %)HAW|HAW0-HAW199999|HAW0-HAW199999|HAW0-HAW199999|HAW0-HAW199999 35 +|=(% style="width: 206px;" %)HUW|HUW0-HUW1599|HUW0-HUW1599|HUW0-HUW1599|HUW0-HUW1599 36 +|=(% style="width: 206px;" %)HDX|HDX0.0-HDX299999.15|HDX0.0-HDX299999.15|HDX0.0-HDX299999.15|HDX0.0-HDX299999.15 37 +|=(% style="width: 206px;" %)HSX|HSX0.0-HSX14999.15|HSX0.0-HSX14999.15|HSX0-HSX14999.15|HSX0.0-HSX14999.15 38 +|=(% style="width: 206px;" %)HAX|HAX0.0-HAX199999.15|HAX0.0-HAX199999.15|HAX0.0-HAX199999.15|HAX0.0-HAX199999.15 39 +|=(% style="width: 206px;" %)HUX|HUX0.0-HUX1599.15|HUX0.0-HUX1599.15|HUX0.0-HUX1599.15|HUX0.0-HUX1599.15 40 +|=(% style="width: 206px;" %)RPW| |RPW000000-RPW990450|RPW000000-RPW990450|RPW000000-RPW990450 41 +|=(% style="width: 206px;" %) |(% style="width:240px" %) |(% style="width:200px" %) |(% style="width:136px" %) |(% style="width:232px" %) 32 32 33 33 = **Data storage area (HDW/HDX)** = 34 34 ... ... @@ -56,20 +56,17 @@ 56 56 57 57 It is system recipe data power-off save register. The range is from RPW000000 to RPW990450. 58 58 59 -(% class="box infomessage" %) 60 -((( 61 61 **✎Note:** 62 62 63 63 * RPW is power-down retention. The register of this type is able to save the data before the power-down. 64 64 * To avoid possible device failure, do not immediately power off and reboot when configuring the power-down save addre 65 -))) 66 66 67 67 = **Single user data area (HUW/HUX)** = 68 68 69 69 It is used for system special registers (reserved by system). 70 70 71 -1. Access as word, and serial number range is from HUW0 to HUW1 599.72 -1. Access as bit, and serial number range is from HUX0.0 to HUX1 599.15.78 +1. Access as word, and serial number range is from HUW0 to HUW199999. 79 +1. Access as bit, and serial number range is from HUX0.0 to HUX199999.15. 73 73 74 74 **✎Note:** 75 75 ... ... @@ -143,8 +143,8 @@ 143 143 (% class="table-bordered" style="width:1024px" %) 144 144 |=(% scope="row" style="width: 160px;" %)**Address**|=(% style="width: 282px;" %)**Function**|=(% style="width: 452px;" %)**Description** 145 145 |=(% style="width: 160px;" %)HSW0|(% style="width:282px" %)Language switch|(% style="width:452px" %)Multiple language could be set in the project, HMI support maximum 8 languages. (Power-down save supported) 146 -|=(% style="width: 160px;" %)HSW1|(% style="width:282px" %)Beep frequency (Only valid in HMI V1.0 System)|(% style="width:452px" %)Frequency range: 0~~4000147 -|=(% style="width: 160px;" %)HSW2|(% style="width:282px" %)Beep volume (Only valid in HMI V1.0 System)|(% style="width:452px" %)Volume range: 0~~80153 +|=(% style="width: 160px;" %)HSW1|(% style="width:282px" %)Beep frequency|(% style="width:452px" %)Frequency range: 0~~4000 154 +|=(% style="width: 160px;" %)HSW2|(% style="width:282px" %)Beep volume|(% style="width:452px" %)Volume range: 0~~80 148 148 |=(% style="width: 160px;" %)HSW3|(% style="width:282px" %)Beep time|(% style="width:452px" %)Unit: ms 149 149 |=(% style="width: 160px;" %)HSW4|(% style="width:282px" %)Beep whether enable or not|(% style="width:452px" %)((( 150 150 * =0: Enable. ... ... @@ -158,7 +158,7 @@ 158 158 ))) 159 159 |=(% style="width: 160px;" %)HSW6~~HSW7|(% style="width:282px" %)Number of alarms|(% style="width:452px" %)The number of alarm (it also includes the records of alarm confirmed) 160 160 |=(% style="width: 160px;" %)HSW8|(% style="width:282px" %)Number of unconfirmed history alarm|(% style="width:452px" %)The number of unconfirmed history alarm 161 -|=(% style="width: 160px;" %)HSW9|(% style="width:282px" %)Time out prompt|(% style="width:452px" %)(((168 +|=(% style="width: 160px;" %)HSW9|(% style="width:282px" %)Time out tip|(% style="width:452px" %)((( 162 162 * =0: Enable 163 163 * =1: Disable 164 164 ))) ... ... @@ -183,7 +183,6 @@ 183 183 * =5: Friday. 184 184 * =6: Saturday. 185 185 ))) 186 -|=(% style="width: 160px;" %)HSW39|(% style="width:282px" %)Beep type(Only valid in HMI V2.0 System)|(% style="width:452px" %)Type range: 1-5, Default is 1. 187 187 |=(% style="width: 160px;" %)HSW134|(% style="width:282px" %)((( 188 188 Whether the Script is read through 189 189 ... ... @@ -459,7 +459,7 @@ 459 459 Address mapping polling cycle, effective range: 40~~1000ms, default: 300ms. 460 460 461 461 * When the set value is greater than 1000, the value is 1000. 462 -* When the set value is lower than40, it changes to the default value 300468 +* When the set value is greater than 1000, it changes to the default value 300 463 463 ))) 464 464 |=(% style="width: 160px;" %)HSW1087|(% style="width:282px" %)Control write interval in address mapping|(% style="width:452px" %)((( 465 465 After reading data to the device for N times, Perform an address mapping write operation. N is the interval value. The effective range: 0~~5, and default is 2. ... ... @@ -913,10 +913,10 @@ 913 913 |=(% style="width: 160px;" %)HSW10000~~19999|(% style="width:282px" %)Power-down storage area|(% style="width:452px" %)After restart, the data remains 914 914 |=(% style="width: 160px;" %)HSW10035|(% rowspan="13" style="width:282px" %)((( 915 915 Note: Valid when Ethernet1 of HMI is plugged into the network cable. 916 -① 917 -② When the Ethernet setting is not enabled in the engineering parameters, the register displays the Ethernet IP automatically acquired by the HMI. 918 -③ When the HMI is not plugged into the network cable, the register will show 0 whether the engineering parameters are set or not. 919 -④ 922 +①、When the Ethernet setting is enabled in the project parameters, this register displays the set value. 923 +②. When the Ethernet setting is not enabled in the engineering parameters, the register displays the Ethernet IP automatically acquired by the HMI. 924 +③. When the HMI is not plugged into the network cable, the register will show 0 whether the engineering parameters are set or not. 925 +④.IP related registers can be read and written (only static IP mode can be written). 920 920 )))|(% style="width:452px" %)Local IP address high byte 1 921 921 |=(% style="width: 160px;" %)HSW10036|(% style="width:452px" %)Local IP address high byte 2 922 922 |=(% style="width: 160px;" %)HSW10037|(% style="width:452px" %)Local IP address high byte 3 ... ... @@ -1010,7 +1010,6 @@ 1010 1010 * =0: LAN or the external network both OK 1011 1011 * =1: Only LAN access 1012 1012 * =2: Only external network can access 1013 -* =3: Close the functions 1014 1014 ))) 1015 1015 |=(% style="width: 160px;" %)HSW11757|(% style="width:282px" %)Enable the valid date of the dynamic installment password|(% style="width:452px" %)((( 1016 1016 * =0: Disabled
- 6.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Mora - Size
-
... ... @@ -1,1 +1,0 @@ 1 -20.1 KB - Content