Changes for page 13 HMI Internal Registers
Last modified by Jett on 2025/04/28 16:07
Summary
-
Page properties (3 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 1 removed)
Details
- Page properties
-
- Title
-
... ... @@ -1,1 +1,1 @@ 1 -1 3.HMIInternalRegisters1 +12 HMI internal registers - Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Mora1 +XWiki.Hunter - Content
-
... ... @@ -27,8 +27,17 @@ 27 27 28 28 = Address ranges table = 29 29 30 -(% style="text-align:center" %) 31 -[[image:6.png]] 30 +(% cellpadding="10" %) 31 +|=(% scope="row" style="width: 218px;" %)Address Type\HMI Series|=(% style="width: 228px;" %)General Series|=(% style="width: 200px;" %)i /HMI+ Series|=(% style="width: 136px;" %)ie Series|=(% style="width: 232px;" %)ig Series 32 +|=(% style="width: 218px;" %)HDW|(% style="width:228px" %)HDW0-HDW299999|HDW0-HDW299999|HDW0-HDW299999|HDW0-HDW299999 33 +|=(% style="width: 218px;" %)HSW|(% style="width:228px" %)HSW0-HSW14999|HSW0-HSW14999|HSW0-HSW14999|HSW0-HSW14999 34 +|=(% style="width: 218px;" %)HAW|(% style="width:228px" %)HAW0-HAW199999|HAW0-HAW199999|HAW0-HAW199999|HAW0-HAW199999 35 +|=(% style="width: 218px;" %)HUW|(% style="width:228px" %)HUW0-HUW1599|HUW0-HUW1599|HUW0-HUW1599|HUW0-HUW1599 36 +|=(% style="width: 218px;" %)HDX|(% style="width:228px" %)HDX0.0-HDX299999.15|HDX0.0-HDX299999.15|HDX0.0-HDX299999.15|HDX0.0-HDX299999.15 37 +|=(% style="width: 218px;" %)HSX|(% style="width:228px" %)HSX0.0-HSX14999.15|HSX0.0-HSX14999.15|HSX0-HSX14999.15|HSX0.0-HSX14999.15 38 +|=(% style="width: 218px;" %)HAX|(% style="width:228px" %)HAX0.0-HAX199999.15|HAX0.0-HAX199999.15|HAX0.0-HAX199999.15|HAX0.0-HAX199999.15 39 +|=(% style="width: 218px;" %)HUX|(% style="width:228px" %)HUX0.0-HUX1599.15|HUX0.0-HUX1599.15|HUX0.0-HUX1599.15|HUX0.0-HUX1599.15 40 +|=(% style="width: 218px;" %)RPW|(% style="width:228px" %) |RPW000000-RPW990450|RPW000000-RPW990450|RPW000000-RPW990450 32 32 33 33 = **Data storage area (HDW/HDX)** = 34 34 ... ... @@ -56,13 +56,10 @@ 56 56 57 57 It is system recipe data power-off save register. The range is from RPW000000 to RPW990450. 58 58 59 -(% class="box infomessage" %) 60 -((( 61 61 **✎Note:** 62 62 63 63 * RPW is power-down retention. The register of this type is able to save the data before the power-down. 64 64 * To avoid possible device failure, do not immediately power off and reboot when configuring the power-down save addre 65 -))) 66 66 67 67 = **Single user data area (HUW/HUX)** = 68 68 ... ... @@ -143,8 +143,8 @@ 143 143 (% class="table-bordered" style="width:1024px" %) 144 144 |=(% scope="row" style="width: 160px;" %)**Address**|=(% style="width: 282px;" %)**Function**|=(% style="width: 452px;" %)**Description** 145 145 |=(% style="width: 160px;" %)HSW0|(% style="width:282px" %)Language switch|(% style="width:452px" %)Multiple language could be set in the project, HMI support maximum 8 languages. (Power-down save supported) 146 -|=(% style="width: 160px;" %)HSW1|(% style="width:282px" %)Beep frequency (Only valid in HMI V1.0 System)|(% style="width:452px" %)Frequency range: 0~~4000147 -|=(% style="width: 160px;" %)HSW2|(% style="width:282px" %)Beep volume (Only valid in HMI V1.0 System)|(% style="width:452px" %)Volume range: 0~~80152 +|=(% style="width: 160px;" %)HSW1|(% style="width:282px" %)Beep frequency|(% style="width:452px" %)Frequency range: 0~~4000 153 +|=(% style="width: 160px;" %)HSW2|(% style="width:282px" %)Beep volume|(% style="width:452px" %)Volume range: 0~~80 148 148 |=(% style="width: 160px;" %)HSW3|(% style="width:282px" %)Beep time|(% style="width:452px" %)Unit: ms 149 149 |=(% style="width: 160px;" %)HSW4|(% style="width:282px" %)Beep whether enable or not|(% style="width:452px" %)((( 150 150 * =0: Enable. ... ... @@ -183,7 +183,6 @@ 183 183 * =5: Friday. 184 184 * =6: Saturday. 185 185 ))) 186 -|=(% style="width: 160px;" %)HSW39|(% style="width:282px" %)Beep type(Only valid in HMI V2.0 System)|(% style="width:452px" %)Type range: 1-5, Default is 1. 187 187 |=(% style="width: 160px;" %)HSW134|(% style="width:282px" %)((( 188 188 Whether the Script is read through 189 189 ... ... @@ -1010,7 +1010,6 @@ 1010 1010 * =0: LAN or the external network both OK 1011 1011 * =1: Only LAN access 1012 1012 * =2: Only external network can access 1013 -* =3: Close the functions 1014 1014 ))) 1015 1015 |=(% style="width: 160px;" %)HSW11757|(% style="width:282px" %)Enable the valid date of the dynamic installment password|(% style="width:452px" %)((( 1016 1016 * =0: Disabled
- 6.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Mora - Size
-
... ... @@ -1,1 +1,0 @@ 1 -20.1 KB - Content