Changes for page 13 HMI Internal Registers

Last modified by Jett on 2025/04/28 16:07

From version 31.1
edited by Mora Zhou
on 2023/11/21 16:19
Change comment: There is no comment for this version
To version 38.1
edited by Jett
on 2025/04/28 16:06
Change comment: There is no comment for this version

Summary

Details

Page properties
Title
... ... @@ -1,1 +1,1 @@
1 -13.HMI Internal Registers
1 +13 HMI Internal Registers
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.Mora
1 +XWiki.2454238480
Content
... ... @@ -71,9 +71,12 @@
71 71  1. Access as word, and serial number range is from HUW0 to HUW1599.
72 72  1. Access as bit, and serial number range is from HUX0.0 to HUX1599.15.
73 73  
74 +(% class="box infomessage" %)
75 +(((
74 74  **✎Note:**
75 75  
76 76  * HUW/HUX is a system special register, so please check the system special register list during use. Please use the address specified in the table and do not use the address which is not mentioned in the table.
79 +)))
77 77  
78 78  (% class="table-bordered" %)
79 79  |=**Special register address**|=**Description**|=**Function**
... ... @@ -135,10 +135,13 @@
135 135  1. Access as word, and serial number range is from HSW0 to HSW49999. (HSW10000 to HSW19999 are the power-off storage areas)
136 136  1. Access as bit, and serial number range is from HSX0.0 to HSX49999.15.
137 137  
141 +(% class="box infomessage" %)
142 +(((
138 138  **✎Note:**
139 139  
140 140  * HSW / HSX are a system special register, so please check the system special register list during use. Please use the address specified in the table and do not use the address which is not mentioned in the table.
141 141  * To avoid possible device failure, do not immediately power off and reboot when configuring the power-down save address.
147 +)))
142 142  
143 143  (% class="table-bordered" style="width:1024px" %)
144 144  |=(% scope="row" style="width: 160px;" %)**Address**|=(% style="width: 282px;" %)**Function**|=(% style="width: 452px;" %)**Description**
... ... @@ -189,7 +189,10 @@
189 189  
190 190  
191 191  )))|(% style="width:452px" %)(((
198 +(% class="box infomessage" %)
199 +(((
192 192  **✎Note:** If want to read-only or write-only, please enable this settings.
201 +)))
193 193  
194 194  * =0: Read from HMI cache(Default)
195 195  * =1: Read from PLC directly
... ... @@ -300,7 +300,7 @@
300 300  * =2: Ejecting SD card, please waiting…
301 301  * =3: SD card ejected
302 302  )))
303 -|=(% style="width: 160px;" %)HSW550~~849|(% style="width:282px" %)Communication control|(% style="width:452px" %)For communication control and communication lamp (please refer to "[[communication control>>http://13.229.109.52:8080/wiki/pistudio/view/Helps/13.HMI%20internal%20registers/#HCommunicationcontrol]]" sector for detailed)
312 +|=(% style="width: 160px;" %)HSW550~~849|(% style="width:282px" %)Communication control|(% style="width:452px" %)For communication control and communication lamp (please refer to "[[Communication control>>https://docs.we-con.com.cn/bin/view/PIStudio/13.HMI%20internal%20registers/#HCommunicationcontrol]]" sector for detailed)
304 304  |=(% style="width: 160px;" %)HSW850|(% style="width:282px" %)(((
305 305  Network state
306 306  
... ... @@ -349,15 +349,15 @@
349 349  * HDX882.1=1 SD card is reading data, don't remove SD card.
350 350  )))
351 351  |=(% style="width: 160px;" %)HSW884|(% style="width:282px" %)Enter the system network configuration interface|(% style="width:452px" %)(((
352 -* =0: Do not enter the network configuration interface
353 -* =1: Enter the system network configuration interface.
361 +* = 0: Do not enter the network configuration interface
362 +* = 1: Enter the system network configuration interface.
354 354  ** ig series HMI only supports to enter the system interface
355 355  
356 356  )))
357 357  |=(% style="width: 160px;" %)HSW885|(% style="width:282px" %)When the control object hides the address is read failed (communication failure), set the display mode of the object|(% style="width:452px" %)(((
358 358  * = 0: displayed by object setting.
359 -* =1: control address read failure, the address control of all objects is hidden, not displayed.
360 -* =2: control address read failure, the address control of all objects is displayed, not hidden.
368 +* = 1: control address read failure, the address control of all objects is hidden, not displayed.
369 +* = 2: control address read failure, the address control of all objects is displayed, not hidden.
361 361  )))
362 362  |=(% style="width: 160px;" %)HSW893|(% style="width:282px" %)(((
363 363  User Permission Control Address, same as HUW1000 feature, please refer to chapter "[[User Permission>>http://13.229.109.52:8080/wiki/pistudio/view/Helps/08.Basic%20Function/#HUserPermission]]"
... ... @@ -380,7 +380,7 @@
380 380  |=(% style="width: 160px;" %)HSW900|(% style="width:282px" %)Quick update frequency settings for objects|(% style="width:452px" %)(((
381 381  Valid when the object is enabled for "quick update". Default: 5.
382 382  
383 -Range: 1 (fastest) ~~ 50 (slowest)
392 +Range: 1 (fastest) - 50 (slowest)
384 384  )))
385 385  |=(% style="width: 160px;" %)HSW920|(% style="width:282px" %)Static mode Maximum periods|(% style="width:452px" %)Numeric Input/ Display (range: 0-12)
386 386  |=(% style="width: 160px;" %)HSW921 ~~ 924|(% style="width:282px" %)Static mode Admin key|(% style="width:452px" %)Character Input/ Display (length: 8)
... ... @@ -430,8 +430,11 @@
430 430  |=(% style="width: 160px;" %)HSW1070|(% style="width:282px" %)The time interval (seconds) since the last time the screen was clicked|(% style="width:452px" %)(((
431 431  Shows how long the current screen has not been clicked, using a decimal unsigned double word (Numeric Input/ Display).
432 432  
442 +(% class="box infomessage" %)
443 +(((
433 433  **✎Note: **This register is cleared to zero regardless of which user clicks on the screen.
434 434  )))
446 +)))
435 435  |=(% style="width: 160px;" %)HSW1073|(% style="width:282px" %)Corresponding key value from keyboard|(% style="width:452px" %)Display the key value of the currently pressed key, the key value is shown in Table 1 (not updated when the character input display is being input)
436 436  |=(% style="width: 160px;" %)HSW1074|(% style="width:282px" %)Keyboard key status|(% style="width:452px" %)Display the current button status (not updated when the numeric input display is being input)(((
437 437  * =0: key release
... ... @@ -910,6 +910,41 @@
910 910  * =2, trigger clear cache of all screens for once time
911 911  * =3, always clear cache of all screen data
912 912  )))
925 +|=(% style="width: 160px;" %)HSW1892|(% colspan="1" style="width:282px" %)Keyboard key polling interval setting|(% style="width:452px" %)(((
926 +~=0,50ms;
927 +
928 +~=1,40ms;
929 +
930 +~=2,30ms;
931 +
932 +~=3,20ms;
933 +
934 +~=4,10ms;
935 +)))
936 +|=(% style="width: 160px;" %)HSW1893|(% colspan="1" style="width:282px" %)Cursor mode switch|(% style="width:452px" %)(((
937 +~=0, default free mode;
938 +
939 +~=1, selected box mode;
940 +
941 +~=2, selected gray mode;
942 +
943 +~=3, mouse selected mode;
944 +)))
945 +|=(% style="width: 160px;" %)HSW1894|(% colspan="1" style="width:282px" %)Enable a specific serial keyboard|(% style="width:452px" %)(((
946 +~=1 Enable;
947 +
948 +~=Other, not enabled;
949 +
950 +Note: Only valid for initialization, recommended to use in background initialization script;
951 +)))
952 +|=(% style="width: 160px;" %)HSW1895|(% colspan="1" style="width:282px" %)Controls whether keyboard keys are effective in certain situations|(% style="width:452px" %)(((
953 +~=0, by default, the key trigger does not take effect when the screen is off or in screen saver mode;
954 +
955 +~=1, HSX1895.0=1, the key trigger will also take effect when the screen is off;
956 +
957 +~=2, HSX1895.1=1, the key trigger will also take effect in screen saver mode;
958 +)))
959 +|=(% style="width: 160px;" %)HSW1903|(% colspan="1" style="width:282px" %)Check the network cable connection status|(% style="width:452px" %)If a network cable is detected, it is set to 1; if no network cable is detected, it is set to 0
913 913  |=(% style="width: 160px;" %)HSW10000~~19999|(% style="width:282px" %)Power-down storage area|(% style="width:452px" %)After restart, the data remains
914 914  |=(% style="width: 160px;" %)HSW10035|(% rowspan="13" style="width:282px" %)(((
915 915  Note: Valid when Ethernet1 of HMI is plugged into the network cable.
... ... @@ -981,7 +981,7 @@
981 981  |=(% style="width: 160px;" %)HSW10606|(% style="width:282px" %)Printer instruction type|(% style="width:452px" %)(((
982 982  * =1: Graphic print type
983 983  * =2: Dot density printing type
984 -* =3: special for EPSON printer
1031 +* =3(Default value): special for EPSON printer
985 985  )))
986 986  |=(% style="width: 160px;" %)HSW10607|(% style="width:282px" %)Printer paper cutting function|(% style="width:452px" %)(((
987 987  * =1: Enable
... ... @@ -992,7 +992,7 @@
992 992  * =2: Center alignment
993 993  * =3: Right alignment
994 994  )))
995 -|=(% style="width: 160px;" %)HSW10610|(% style="width:282px" %)Set weconcloud server|(% style="width:452px" %)(((
1042 +|=(% style="width: 160px;" %)HSW10611|(% style="width:282px" %)Set weconcloud server|(% style="width:452px" %)(((
996 996  * =0: Select the server configured in "Project Settings"
997 997  * =1: select Server 1
998 998  * =2: select Server 2
... ... @@ -1002,6 +1002,12 @@
1002 1002  * =1: English
1003 1003  * =2: Chinese
1004 1004  )))
1052 +|=(% style="width: 160px;" %)HSW11752|(% style="width:282px" %)Traffic monitoring control|(% style="width:452px" %)= 1: Enable the flow monitoring function
1053 +~= Other: Disable the flow monitoring function
1054 +|=(% style="width: 160px;" %)HSW11753|(% style="width:282px" %)Traffic monitoring network card type|(% style="width:452px" %)= 0: Ethernet card
1055 +~= 1: 4G
1056 +~= 2: Wi-Fi
1057 +|=(% style="width: 160px;" %)HSW11754-11755|(% style="width:282px" %)Historical traffic consumption|(% style="width:452px" %)The total traffic consumed historically (bytes) [value is an integer]
1005 1005  |=(% style="width: 160px;" %)HSW11756|(% style="width:282px" %)(((
1006 1006  Access permission restrictions
1007 1007  
... ... @@ -1052,7 +1052,17 @@
1052 1052  )))|(% style="width:452px" %)(((
1053 1053  ~=0: Raster,=1: Blinds,=2: Bubble
1054 1054  )))
1108 +|=(% style="width: 160px;" %)HSW11767|(% style="width:282px" %)Remote screen display adaptation mode switching|(% style="width:452px" %)=0, default mode, remote full-screen zoom display for horizontal screen projects, remote proportional zoom display for vertical screen projects;
1109 +~=1, full-screen zoom display;
1110 +~=2, proportional zoom display according to screen size ratio;
1111 +~=3, no zoom display according to screen pixels;
1112 +|=(% style="width: 160px;" %)HSW11773|(% style="width:282px" %)Automatically log out user control address|(% style="width:452px" %)=3: that is, HSX11773.0=1, HSX11773.1=1, based on the configuration in the address, enable automatic user logout.
1113 +|=(% style="width: 160px;" %)HSW11774|(% style="width:282px" %)Automatic user logout interval|(% style="width:452px" %)(((
1114 +Range: 1 to 255
1055 1055  
1116 +Unit: Minutes
1117 +)))
1118 +
1056 1056  == Serial port communication configuration ==
1057 1057  