Changes for page 13 HMI Internal Registers
Last modified by Jett on 2025/04/28 16:07
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -56,13 +56,10 @@ 56 56 57 57 It is system recipe data power-off save register. The range is from RPW000000 to RPW990450. 58 58 59 -(% class="box infomessage" %) 60 -((( 61 61 **✎Note:** 62 62 63 63 * RPW is power-down retention. The register of this type is able to save the data before the power-down. 64 64 * To avoid possible device failure, do not immediately power off and reboot when configuring the power-down save addre 65 -))) 66 66 67 67 = **Single user data area (HUW/HUX)** = 68 68 ... ... @@ -71,12 +71,9 @@ 71 71 1. Access as word, and serial number range is from HUW0 to HUW1599. 72 72 1. Access as bit, and serial number range is from HUX0.0 to HUX1599.15. 73 73 74 -(% class="box infomessage" %) 75 -((( 76 76 **✎Note:** 77 77 78 78 * HUW/HUX is a system special register, so please check the system special register list during use. Please use the address specified in the table and do not use the address which is not mentioned in the table. 79 -))) 80 80 81 81 (% class="table-bordered" %) 82 82 |=**Special register address**|=**Description**|=**Function** ... ... @@ -146,8 +146,8 @@ 146 146 (% class="table-bordered" style="width:1024px" %) 147 147 |=(% scope="row" style="width: 160px;" %)**Address**|=(% style="width: 282px;" %)**Function**|=(% style="width: 452px;" %)**Description** 148 148 |=(% style="width: 160px;" %)HSW0|(% style="width:282px" %)Language switch|(% style="width:452px" %)Multiple language could be set in the project, HMI support maximum 8 languages. (Power-down save supported) 149 -|=(% style="width: 160px;" %)HSW1|(% style="width:282px" %)Beep frequency (Only valid in HMI V1.0 System)|(% style="width:452px" %)Frequency range: 0~~4000150 -|=(% style="width: 160px;" %)HSW2|(% style="width:282px" %)Beep volume (Only valid in HMI V1.0 System)|(% style="width:452px" %)Volume range: 0~~80143 +|=(% style="width: 160px;" %)HSW1|(% style="width:282px" %)Beep frequency|(% style="width:452px" %)Frequency range: 0~~4000 144 +|=(% style="width: 160px;" %)HSW2|(% style="width:282px" %)Beep volume|(% style="width:452px" %)Volume range: 0~~80 151 151 |=(% style="width: 160px;" %)HSW3|(% style="width:282px" %)Beep time|(% style="width:452px" %)Unit: ms 152 152 |=(% style="width: 160px;" %)HSW4|(% style="width:282px" %)Beep whether enable or not|(% style="width:452px" %)((( 153 153 * =0: Enable. ... ... @@ -186,7 +186,6 @@ 186 186 * =5: Friday. 187 187 * =6: Saturday. 188 188 ))) 189 -|=(% style="width: 160px;" %)HSW39|(% style="width:282px" %)Beep type(Only valid in HMI V2.0 System)|(% style="width:452px" %)Type range: 1-5, Default is 1. 190 190 |=(% style="width: 160px;" %)HSW134|(% style="width:282px" %)((( 191 191 Whether the Script is read through 192 192 ... ... @@ -1013,7 +1013,6 @@ 1013 1013 * =0: LAN or the external network both OK 1014 1014 * =1: Only LAN access 1015 1015 * =2: Only external network can access 1016 -* =3: Close the functions 1017 1017 ))) 1018 1018 |=(% style="width: 160px;" %)HSW11757|(% style="width:282px" %)Enable the valid date of the dynamic installment password|(% style="width:452px" %)((( 1019 1019 * =0: Disabled