Changes for page 13 HMI Internal Registers

Last modified by Jett on 2025/04/28 16:07

From version 32.1
edited by Mora Zhou
on 2023/11/21 16:20
Change comment: There is no comment for this version
To version 33.1
edited by Mora Zhou
on 2023/11/21 16:25
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -138,10 +138,13 @@
138 138  1. Access as word, and serial number range is from HSW0 to HSW49999. (HSW10000 to HSW19999 are the power-off storage areas)
139 139  1. Access as bit, and serial number range is from HSX0.0 to HSX49999.15.
140 140  
141 +(% class="box infomessage" %)
142 +(((
141 141  **✎Note:**
142 142  
143 143  * HSW / HSX are a system special register, so please check the system special register list during use. Please use the address specified in the table and do not use the address which is not mentioned in the table.
144 144  * To avoid possible device failure, do not immediately power off and reboot when configuring the power-down save address.
147 +)))
145 145  
146 146  (% class="table-bordered" style="width:1024px" %)
147 147  |=(% scope="row" style="width: 160px;" %)**Address**|=(% style="width: 282px;" %)**Function**|=(% style="width: 452px;" %)**Description**
... ... @@ -192,7 +192,10 @@
192 192  
193 193  
194 194  )))|(% style="width:452px" %)(((
198 +(% class="box infomessage" %)
199 +(((
195 195  **✎Note:** If want to read-only or write-only, please enable this settings.
201 +)))
196 196  
197 197  * =0: Read from HMI cache(Default)
198 198  * =1: Read from PLC directly
... ... @@ -303,7 +303,7 @@
303 303  * =2: Ejecting SD card, please waiting…
304 304  * =3: SD card ejected
305 305  )))
306 -|=(% style="width: 160px;" %)HSW550~~849|(% style="width:282px" %)Communication control|(% style="width:452px" %)For communication control and communication lamp (please refer to "[[communication control>>http://13.229.109.52:8080/wiki/pistudio/view/Helps/13.HMI%20internal%20registers/#HCommunicationcontrol]]" sector for detailed)
312 +|=(% style="width: 160px;" %)HSW550~~849|(% style="width:282px" %)Communication control|(% style="width:452px" %)For communication control and communication lamp (please refer to "[[Communication control>>http://13.229.109.52:8080/wiki/pistudio/view/Helps/13.HMI%20internal%20registers/#HCommunicationcontrol]]" sector for detailed)
307 307  |=(% style="width: 160px;" %)HSW850|(% style="width:282px" %)(((
308 308  Network state
309 309  
... ... @@ -352,15 +352,15 @@
352 352  * HDX882.1=1 SD card is reading data, don't remove SD card.
353 353  )))
354 354  |=(% style="width: 160px;" %)HSW884|(% style="width:282px" %)Enter the system network configuration interface|(% style="width:452px" %)(((
355 -* =0: Do not enter the network configuration interface
356 -* =1: Enter the system network configuration interface.
361 +* = 0: Do not enter the network configuration interface
362 +* = 1: Enter the system network configuration interface.
357 357  ** ig series HMI only supports to enter the system interface
358 358  
359 359  )))
360 360  |=(% style="width: 160px;" %)HSW885|(% style="width:282px" %)When the control object hides the address is read failed (communication failure), set the display mode of the object|(% style="width:452px" %)(((
361 361  * = 0: displayed by object setting.
362 -* =1: control address read failure, the address control of all objects is hidden, not displayed.
363 -* =2: control address read failure, the address control of all objects is displayed, not hidden.
368 +* = 1: control address read failure, the address control of all objects is hidden, not displayed.
369 +* = 2: control address read failure, the address control of all objects is displayed, not hidden.
364 364  )))
365 365  |=(% style="width: 160px;" %)HSW893|(% style="width:282px" %)(((
366 366  User Permission Control Address, same as HUW1000 feature, please refer to chapter "[[User Permission>>http://13.229.109.52:8080/wiki/pistudio/view/Helps/08.Basic%20Function/#HUserPermission]]"
... ... @@ -383,7 +383,7 @@
383 383  |=(% style="width: 160px;" %)HSW900|(% style="width:282px" %)Quick update frequency settings for objects|(% style="width:452px" %)(((
384 384  Valid when the object is enabled for "quick update". Default: 5.
385 385  
386 -Range: 1 (fastest) ~~ 50 (slowest)
392 +Range: 1 (fastest) - 50 (slowest)
387 387  )))
388 388  |=(% style="width: 160px;" %)HSW920|(% style="width:282px" %)Static mode Maximum periods|(% style="width:452px" %)Numeric Input/ Display (range: 0-12)
389 389  |=(% style="width: 160px;" %)HSW921 ~~ 924|(% style="width:282px" %)Static mode Admin key|(% style="width:452px" %)Character Input/ Display (length: 8)
... ... @@ -433,8 +433,11 @@
433 433  |=(% style="width: 160px;" %)HSW1070|(% style="width:282px" %)The time interval (seconds) since the last time the screen was clicked|(% style="width:452px" %)(((
434 434  Shows how long the current screen has not been clicked, using a decimal unsigned double word (Numeric Input/ Display).
435 435  
442 +(% class="box infomessage" %)
443 +(((
436 436  **✎Note: **This register is cleared to zero regardless of which user clicks on the screen.
437 437  )))
446 +)))
438 438  |=(% style="width: 160px;" %)HSW1073|(% style="width:282px" %)Corresponding key value from keyboard|(% style="width:452px" %)Display the key value of the currently pressed key, the key value is shown in Table 1 (not updated when the character input display is being input)
439 439  |=(% style="width: 160px;" %)HSW1074|(% style="width:282px" %)Keyboard key status|(% style="width:452px" %)Display the current button status (not updated when the numeric input display is being input)(((
440 440  * =0: key release