... ... @@ -138,10 +138,13 @@
138 138  1. Access as word, and serial number range is from HSW0 to HSW49999. (HSW10000 to HSW19999 are the power-off storage areas)
139 139  1. Access as bit, and serial number range is from HSX0.0 to HSX49999.15.
140 140  
141 +(% class="box infomessage" %)
142 +(((
141 141  **✎Note:**
142 142  
143 143  * HSW / HSX are a system special register, so please check the system special register list during use. Please use the address specified in the table and do not use the address which is not mentioned in the table.
144 144  * To avoid possible device failure, do not immediately power off and reboot when configuring the power-down save address.
147 +)))
145 145  
146 146  (% class="table-bordered" style="width:1024px" %)
147 147  |=(% scope="row" style="width: 160px;" %)**Address**|=(% style="width: 282px;" %)**Function**|=(% style="width: 452px;" %)**Description**
... ... @@ -192,7 +192,10 @@
192 192  
193 193  
194 194  )))|(% style="width:452px" %)(((
198 +(% class="box infomessage" %)
199 +(((
195 195  **✎Note:** If want to read-only or write-only, please enable this settings.
201 +)))
196 196  
197 197  * =0: Read from HMI cache(Default)
198 198  * =1: Read from PLC directly
... ... @@ -303,7 +303,7 @@
303 303  * =2: Ejecting SD card, please waiting…
304 304  * =3: SD card ejected
305 305  )))
306 -|=(% style="width: 160px;" %)HSW550~~849|(% style="width:282px" %)Communication control|(% style="width:452px" %)For communication control and communication lamp (please refer to "[[communication control>>http://13.229.109.52:8080/wiki/pistudio/view/Helps/13.HMI%20internal%20registers/#HCommunicationcontrol]]" sector for detailed)
312 +|=(% style="width: 160px;" %)HSW550~~849|(% style="width:282px" %)Communication control|(% style="width:452px" %)For communication control and communication lamp (please refer to "[[Communication control>>https://docs.we-con.com.cn/bin/view/PIStudio/13.HMI%20internal%20registers/#HCommunicationcontrol]]" sector for detailed)
307 307  |=(% style="width: 160px;" %)HSW850|(% style="width:282px" %)(((
308 308  Network state
309 309  
... ... @@ -352,15 +352,15 @@
352 352  * HDX882.1=1 SD card is reading data, don't remove SD card.
353 353  )))
354 354  |=(% style="width: 160px;" %)HSW884|(% style="width:282px" %)Enter the system network configuration interface|(% style="width:452px" %)(((
355 -* =0: Do not enter the network configuration interface
356 -* =1: Enter the system network configuration interface.
361 +* = 0: Do not enter the network configuration interface
362 +* = 1: Enter the system network configuration interface.
357 357  ** ig series HMI only supports to enter the system interface
358 358  
359 359  )))
360 360  |=(% style="width: 160px;" %)HSW885|(% style="width:282px" %)When the control object hides the address is read failed (communication failure), set the display mode of the object|(% style="width:452px" %)(((
361 361  * = 0: displayed by object setting.
362 -* =1: control address read failure, the address control of all objects is hidden, not displayed.
363 -* =2: control address read failure, the address control of all objects is displayed, not hidden.
368 +* = 1: control address read failure, the address control of all objects is hidden, not displayed.
369 +* = 2: control address read failure, the address control of all objects is displayed, not hidden.
364 364  )))
365 365  |=(% style="width: 160px;" %)HSW893|(% style="width:282px" %)(((
366 366  User Permission Control Address, same as HUW1000 feature, please refer to chapter "[[User Permission>>http://13.229.109.52:8080/wiki/pistudio/view/Helps/08.Basic%20Function/#HUserPermission]]"
... ... @@ -383,7 +383,7 @@
383 383  |=(% style="width: 160px;" %)HSW900|(% style="width:282px" %)Quick update frequency settings for objects|(% style="width:452px" %)(((
384 384  Valid when the object is enabled for "quick update". Default: 5.
385 385  
386 -Range: 1 (fastest) ~~ 50 (slowest)
392 +Range: 1 (fastest) - 50 (slowest)
387 387  )))
388 388  |=(% style="width: 160px;" %)HSW920|(% style="width:282px" %)Static mode Maximum periods|(% style="width:452px" %)Numeric Input/ Display (range: 0-12)
389 389  |=(% style="width: 160px;" %)HSW921 ~~ 924|(% style="width:282px" %)Static mode Admin key|(% style="width:452px" %)Character Input/ Display (length: 8)
... ... @@ -433,8 +433,11 @@
433 433  |=(% style="width: 160px;" %)HSW1070|(% style="width:282px" %)The time interval (seconds) since the last time the screen was clicked|(% style="width:452px" %)(((
434 434  Shows how long the current screen has not been clicked, using a decimal unsigned double word (Numeric Input/ Display).
435 435  
442 +(% class="box infomessage" %)
443 +(((
436 436  **✎Note: **This register is cleared to zero regardless of which user clicks on the screen.
437 437  )))
446 +)))
438 438  |=(% style="width: 160px;" %)HSW1073|(% style="width:282px" %)Corresponding key value from keyboard|(% style="width:452px" %)Display the key value of the currently pressed key, the key value is shown in Table 1 (not updated when the character input display is being input)
439 439  |=(% style="width: 160px;" %)HSW1074|(% style="width:282px" %)Keyboard key status|(% style="width:452px" %)Display the current button status (not updated when the numeric input display is being input)(((
440 440  * =0: key release
... ... @@ -913,6 +913,41 @@
913 913  * =2, trigger clear cache of all screens for once time
914 914  * =3, always clear cache of all screen data
915 915  )))
925 +|=(% style="width: 160px;" %)HSW1892|(% colspan="1" style="width:282px" %)Keyboard key polling interval setting|(% style="width:452px" %)(((
926 +~=0,50ms;
927 +
928 +~=1,40ms;
929 +
930 +~=2,30ms;
931 +
932 +~=3,20ms;
933 +
934 +~=4,10ms;
935 +)))
936 +|=(% style="width: 160px;" %)HSW1893|(% colspan="1" style="width:282px" %)Cursor mode switch|(% style="width:452px" %)(((
937 +~=0, default free mode;
938 +
939 +~=1, selected box mode;
940 +
941 +~=2, selected gray mode;
942 +
943 +~=3, mouse selected mode;
944 +)))
945 +|=(% style="width: 160px;" %)HSW1894|(% colspan="1" style="width:282px" %)Enable a specific serial keyboard|(% style="width:452px" %)(((
946 +~=1 Enable;
947 +
948 +~=Other, not enabled;
949 +
950 +Note: Only valid for initialization, recommended to use in background initialization script;
951 +)))
952 +|=(% style="width: 160px;" %)HSW1895|(% colspan="1" style="width:282px" %)Controls whether keyboard keys are effective in certain situations|(% style="width:452px" %)(((
953 +~=0, by default, the key trigger does not take effect when the screen is off or in screen saver mode;
954 +
955 +~=1, HSX1895.0=1, the key trigger will also take effect when the screen is off;
956 +
957 +~=2, HSX1895.1=1, the key trigger will also take effect in screen saver mode;
958 +)))
959 +|=(% style="width: 160px;" %)HSW1903|(% colspan="1" style="width:282px" %)Check the network cable connection status|(% style="width:452px" %)If a network cable is detected, it is set to 1; if no network cable is detected, it is set to 0
916 916  |=(% style="width: 160px;" %)HSW10000~~19999|(% style="width:282px" %)Power-down storage area|(% style="width:452px" %)After restart, the data remains
917 917  |=(% style="width: 160px;" %)HSW10035|(% rowspan="13" style="width:282px" %)(((
918 918  Note: Valid when Ethernet1 of HMI is plugged into the network cable.
... ... @@ -984,7 +984,7 @@
984 984  |=(% style="width: 160px;" %)HSW10606|(% style="width:282px" %)Printer instruction type|(% style="width:452px" %)(((
985 985  * =1: Graphic print type
986 986  * =2: Dot density printing type
987 -* =3: special for EPSON printer
1031 +* =3(Default value): special for EPSON printer
988 988  )))
989 989  |=(% style="width: 160px;" %)HSW10607|(% style="width:282px" %)Printer paper cutting function|(% style="width:452px" %)(((
990 990  * =1: Enable
... ... @@ -995,7 +995,7 @@
995 995  * =2: Center alignment
996 996  * =3: Right alignment
997 997  )))
998 -|=(% style="width: 160px;" %)HSW10610|(% style="width:282px" %)Set weconcloud server|(% style="width:452px" %)(((
1042 +|=(% style="width: 160px;" %)HSW10611|(% style="width:282px" %)Set weconcloud server|(% style="width:452px" %)(((
999 999  * =0: Select the server configured in "Project Settings"
1000 1000  * =1: select Server 1
1001 1001  * =2: select Server 2
... ... @@ -1005,6 +1005,12 @@
1005 1005  * =1: English
1006 1006  * =2: Chinese
1007 1007  )))
1052 +|=(% style="width: 160px;" %)HSW11752|(% style="width:282px" %)Traffic monitoring control|(% style="width:452px" %)= 1: Enable the flow monitoring function
1053 +~= Other: Disable the flow monitoring function
1054 +|=(% style="width: 160px;" %)HSW11753|(% style="width:282px" %)Traffic monitoring network card type|(% style="width:452px" %)= 0: Ethernet card
1055 +~= 1: 4G
1056 +~= 2: Wi-Fi
1057 +|=(% style="width: 160px;" %)HSW11754-11755|(% style="width:282px" %)Historical traffic consumption|(% style="width:452px" %)The total traffic consumed historically (bytes) [value is an integer]
1008 1008  |=(% style="width: 160px;" %)HSW11756|(% style="width:282px" %)(((
1009 1009  Access permission restrictions
1010 1010  
... ... @@ -1055,7 +1055,17 @@
1055 1055  )))|(% style="width:452px" %)(((
1056 1056  ~=0: Raster,=1: Blinds,=2: Bubble
1057 1057  )))
1108 +|=(% style="width: 160px;" %)HSW11767|(% style="width:282px" %)Remote screen display adaptation mode switching|(% style="width:452px" %)=0, default mode, remote full-screen zoom display for horizontal screen projects, remote proportional zoom display for vertical screen projects;
1109 +~=1, full-screen zoom display;
1110 +~=2, proportional zoom display according to screen size ratio;
1111 +~=3, no zoom display according to screen pixels;
1112 +|=(% style="width: 160px;" %)HSW11773|(% style="width:282px" %)Automatically log out user control address|(% style="width:452px" %)=3: that is, HSX11773.0=1, HSX11773.1=1, based on the configuration in the address, enable automatic user logout.
1113 +|=(% style="width: 160px;" %)HSW11774|(% style="width:282px" %)Automatic user logout interval|(% style="width:452px" %)(((
1114 +Range: 1 to 255
1058 1058  
1116 +Unit: Minutes
1117 +)))
1118 +
1059 1059  == Serial port communication configuration ==
1060 1060  
1061 1061  (% class="table-bordered" %)