Changes for page 13 HMI Internal Registers
Last modified by Jett on 2025/04/28 16:07
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Title
-
... ... @@ -1,1 +1,1 @@ 1 -1 4HMI Internal Registers1 +13.HMI Internal Registers - Content
-
... ... @@ -71,12 +71,9 @@ 71 71 1. Access as word, and serial number range is from HUW0 to HUW1599. 72 72 1. Access as bit, and serial number range is from HUX0.0 to HUX1599.15. 73 73 74 -(% class="box infomessage" %) 75 -((( 76 76 **✎Note:** 77 77 78 78 * HUW/HUX is a system special register, so please check the system special register list during use. Please use the address specified in the table and do not use the address which is not mentioned in the table. 79 -))) 80 80 81 81 (% class="table-bordered" %) 82 82 |=**Special register address**|=**Description**|=**Function** ... ... @@ -138,13 +138,10 @@ 138 138 1. Access as word, and serial number range is from HSW0 to HSW49999. (HSW10000 to HSW19999 are the power-off storage areas) 139 139 1. Access as bit, and serial number range is from HSX0.0 to HSX49999.15. 140 140 141 -(% class="box infomessage" %) 142 -((( 143 143 **✎Note:** 144 144 145 145 * HSW / HSX are a system special register, so please check the system special register list during use. Please use the address specified in the table and do not use the address which is not mentioned in the table. 146 146 * To avoid possible device failure, do not immediately power off and reboot when configuring the power-down save address. 147 -))) 148 148 149 149 (% class="table-bordered" style="width:1024px" %) 150 150 |=(% scope="row" style="width: 160px;" %)**Address**|=(% style="width: 282px;" %)**Function**|=(% style="width: 452px;" %)**Description** ... ... @@ -195,10 +195,7 @@ 195 195 196 196 197 197 )))|(% style="width:452px" %)((( 198 -(% class="box infomessage" %) 199 -((( 200 200 **✎Note:** If want to read-only or write-only, please enable this settings. 201 -))) 202 202 203 203 * =0: Read from HMI cache(Default) 204 204 * =1: Read from PLC directly ... ... @@ -309,7 +309,7 @@ 309 309 * =2: Ejecting SD card, please waiting… 310 310 * =3: SD card ejected 311 311 ))) 312 -|=(% style="width: 160px;" %)HSW550~~849|(% style="width:282px" %)Communication control|(% style="width:452px" %)For communication control and communication lamp (please refer to "[[ Communication control>>http://13.229.109.52:8080/wiki/pistudio/view/Helps/13.HMI%20internal%20registers/#HCommunicationcontrol]]" sector for detailed)303 +|=(% style="width: 160px;" %)HSW550~~849|(% style="width:282px" %)Communication control|(% style="width:452px" %)For communication control and communication lamp (please refer to "[[communication control>>http://13.229.109.52:8080/wiki/pistudio/view/Helps/13.HMI%20internal%20registers/#HCommunicationcontrol]]" sector for detailed) 313 313 |=(% style="width: 160px;" %)HSW850|(% style="width:282px" %)((( 314 314 Network state 315 315 ... ... @@ -358,15 +358,15 @@ 358 358 * HDX882.1=1 SD card is reading data, don't remove SD card. 359 359 ))) 360 360 |=(% style="width: 160px;" %)HSW884|(% style="width:282px" %)Enter the system network configuration interface|(% style="width:452px" %)((( 361 -* = 362 -* = 352 +* =0: Do not enter the network configuration interface 353 +* =1: Enter the system network configuration interface. 363 363 ** ig series HMI only supports to enter the system interface 364 364 365 365 ))) 366 366 |=(% style="width: 160px;" %)HSW885|(% style="width:282px" %)When the control object hides the address is read failed (communication failure), set the display mode of the object|(% style="width:452px" %)((( 367 367 * = 0: displayed by object setting. 368 -* = 369 -* = 359 +* =1: control address read failure, the address control of all objects is hidden, not displayed. 360 +* =2: control address read failure, the address control of all objects is displayed, not hidden. 370 370 ))) 371 371 |=(% style="width: 160px;" %)HSW893|(% style="width:282px" %)((( 372 372 User Permission Control Address, same as HUW1000 feature, please refer to chapter "[[User Permission>>http://13.229.109.52:8080/wiki/pistudio/view/Helps/08.Basic%20Function/#HUserPermission]]" ... ... @@ -389,7 +389,7 @@ 389 389 |=(% style="width: 160px;" %)HSW900|(% style="width:282px" %)Quick update frequency settings for objects|(% style="width:452px" %)((( 390 390 Valid when the object is enabled for "quick update". Default: 5. 391 391 392 -Range: 1 (fastest) -50 (slowest)383 +Range: 1 (fastest) ~~ 50 (slowest) 393 393 ))) 394 394 |=(% style="width: 160px;" %)HSW920|(% style="width:282px" %)Static mode Maximum periods|(% style="width:452px" %)Numeric Input/ Display (range: 0-12) 395 395 |=(% style="width: 160px;" %)HSW921 ~~ 924|(% style="width:282px" %)Static mode Admin key|(% style="width:452px" %)Character Input/ Display (length: 8) ... ... @@ -439,11 +439,8 @@ 439 439 |=(% style="width: 160px;" %)HSW1070|(% style="width:282px" %)The time interval (seconds) since the last time the screen was clicked|(% style="width:452px" %)((( 440 440 Shows how long the current screen has not been clicked, using a decimal unsigned double word (Numeric Input/ Display). 441 441 442 -(% class="box infomessage" %) 443 -((( 444 444 **✎Note: **This register is cleared to zero regardless of which user clicks on the screen. 445 445 ))) 446 -))) 447 447 |=(% style="width: 160px;" %)HSW1073|(% style="width:282px" %)Corresponding key value from keyboard|(% style="width:452px" %)Display the key value of the currently pressed key, the key value is shown in Table 1 (not updated when the character input display is being input) 448 448 |=(% style="width: 160px;" %)HSW1074|(% style="width:282px" %)Keyboard key status|(% style="width:452px" %)Display the current button status (not updated when the numeric input display is being input)((( 449 449 * =0: key release