Changes for page 13 HMI Internal Registers
Last modified by Jett on 2025/04/28 16:07
Summary
-
Page properties (3 modified, 0 added, 0 removed)
Details
- Page properties
-
- Title
-
... ... @@ -1,1 +1,1 @@ 1 -13 1 +13.HMI Internal Registers - Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. 24542384801 +XWiki.Mora - Content
-
... ... @@ -56,13 +56,10 @@ 56 56 57 57 It is system recipe data power-off save register. The range is from RPW000000 to RPW990450. 58 58 59 -(% class="box infomessage" %) 60 -((( 61 61 **✎Note:** 62 62 63 63 * RPW is power-down retention. The register of this type is able to save the data before the power-down. 64 64 * To avoid possible device failure, do not immediately power off and reboot when configuring the power-down save addre 65 -))) 66 66 67 67 = **Single user data area (HUW/HUX)** = 68 68 ... ... @@ -71,12 +71,9 @@ 71 71 1. Access as word, and serial number range is from HUW0 to HUW1599. 72 72 1. Access as bit, and serial number range is from HUX0.0 to HUX1599.15. 73 73 74 -(% class="box infomessage" %) 75 -((( 76 76 **✎Note:** 77 77 78 78 * HUW/HUX is a system special register, so please check the system special register list during use. Please use the address specified in the table and do not use the address which is not mentioned in the table. 79 -))) 80 80 81 81 (% class="table-bordered" %) 82 82 |=**Special register address**|=**Description**|=**Function** ... ... @@ -138,13 +138,10 @@ 138 138 1. Access as word, and serial number range is from HSW0 to HSW49999. (HSW10000 to HSW19999 are the power-off storage areas) 139 139 1. Access as bit, and serial number range is from HSX0.0 to HSX49999.15. 140 140 141 -(% class="box infomessage" %) 142 -((( 143 143 **✎Note:** 144 144 145 145 * HSW / HSX are a system special register, so please check the system special register list during use. Please use the address specified in the table and do not use the address which is not mentioned in the table. 146 146 * To avoid possible device failure, do not immediately power off and reboot when configuring the power-down save address. 147 -))) 148 148 149 149 (% class="table-bordered" style="width:1024px" %) 150 150 |=(% scope="row" style="width: 160px;" %)**Address**|=(% style="width: 282px;" %)**Function**|=(% style="width: 452px;" %)**Description** ... ... @@ -195,10 +195,7 @@ 195 195 196 196 197 197 )))|(% style="width:452px" %)((( 198 -(% class="box infomessage" %) 199 -((( 200 200 **✎Note:** If want to read-only or write-only, please enable this settings. 201 -))) 202 202 203 203 * =0: Read from HMI cache(Default) 204 204 * =1: Read from PLC directly ... ... @@ -309,7 +309,7 @@ 309 309 * =2: Ejecting SD card, please waiting… 310 310 * =3: SD card ejected 311 311 ))) 312 -|=(% style="width: 160px;" %)HSW550~~849|(% style="width:282px" %)Communication control|(% style="width:452px" %)For communication control and communication lamp (please refer to "[[ Communication control>>https://docs.we-con.com.cn/bin/view/PIStudio/13.HMI%20internal%20registers/#HCommunicationcontrol]]" sector for detailed)300 +|=(% style="width: 160px;" %)HSW550~~849|(% style="width:282px" %)Communication control|(% style="width:452px" %)For communication control and communication lamp (please refer to "[[communication control>>http://13.229.109.52:8080/wiki/pistudio/view/Helps/13.HMI%20internal%20registers/#HCommunicationcontrol]]" sector for detailed) 313 313 |=(% style="width: 160px;" %)HSW850|(% style="width:282px" %)((( 314 314 Network state 315 315 ... ... @@ -358,15 +358,15 @@ 358 358 * HDX882.1=1 SD card is reading data, don't remove SD card. 359 359 ))) 360 360 |=(% style="width: 160px;" %)HSW884|(% style="width:282px" %)Enter the system network configuration interface|(% style="width:452px" %)((( 361 -* = 362 -* = 349 +* =0: Do not enter the network configuration interface 350 +* =1: Enter the system network configuration interface. 363 363 ** ig series HMI only supports to enter the system interface 364 364 365 365 ))) 366 366 |=(% style="width: 160px;" %)HSW885|(% style="width:282px" %)When the control object hides the address is read failed (communication failure), set the display mode of the object|(% style="width:452px" %)((( 367 367 * = 0: displayed by object setting. 368 -* = 369 -* = 356 +* =1: control address read failure, the address control of all objects is hidden, not displayed. 357 +* =2: control address read failure, the address control of all objects is displayed, not hidden. 370 370 ))) 371 371 |=(% style="width: 160px;" %)HSW893|(% style="width:282px" %)((( 372 372 User Permission Control Address, same as HUW1000 feature, please refer to chapter "[[User Permission>>http://13.229.109.52:8080/wiki/pistudio/view/Helps/08.Basic%20Function/#HUserPermission]]" ... ... @@ -389,7 +389,7 @@ 389 389 |=(% style="width: 160px;" %)HSW900|(% style="width:282px" %)Quick update frequency settings for objects|(% style="width:452px" %)((( 390 390 Valid when the object is enabled for "quick update". Default: 5. 391 391 392 -Range: 1 (fastest) -50 (slowest)380 +Range: 1 (fastest) ~~ 50 (slowest) 393 393 ))) 394 394 |=(% style="width: 160px;" %)HSW920|(% style="width:282px" %)Static mode Maximum periods|(% style="width:452px" %)Numeric Input/ Display (range: 0-12) 395 395 |=(% style="width: 160px;" %)HSW921 ~~ 924|(% style="width:282px" %)Static mode Admin key|(% style="width:452px" %)Character Input/ Display (length: 8) ... ... @@ -439,11 +439,8 @@ 439 439 |=(% style="width: 160px;" %)HSW1070|(% style="width:282px" %)The time interval (seconds) since the last time the screen was clicked|(% style="width:452px" %)((( 440 440 Shows how long the current screen has not been clicked, using a decimal unsigned double word (Numeric Input/ Display). 441 441 442 -(% class="box infomessage" %) 443 -((( 444 444 **✎Note: **This register is cleared to zero regardless of which user clicks on the screen. 445 445 ))) 446 -))) 447 447 |=(% style="width: 160px;" %)HSW1073|(% style="width:282px" %)Corresponding key value from keyboard|(% style="width:452px" %)Display the key value of the currently pressed key, the key value is shown in Table 1 (not updated when the character input display is being input) 448 448 |=(% style="width: 160px;" %)HSW1074|(% style="width:282px" %)Keyboard key status|(% style="width:452px" %)Display the current button status (not updated when the numeric input display is being input)((( 449 449 * =0: key release ... ... @@ -922,41 +922,6 @@ 922 922 * =2, trigger clear cache of all screens for once time 923 923 * =3, always clear cache of all screen data 924 924 ))) 925 -|=(% style="width: 160px;" %)HSW1892|(% colspan="1" style="width:282px" %)Keyboard key polling interval setting|(% style="width:452px" %)((( 926 -~=0,50ms; 927 - 928 -~=1,40ms; 929 - 930 -~=2,30ms; 931 - 932 -~=3,20ms; 933 - 934 -~=4,10ms; 935 -))) 936 -|=(% style="width: 160px;" %)HSW1893|(% colspan="1" style="width:282px" %)Cursor mode switch|(% style="width:452px" %)((( 937 -~=0, default free mode; 938 - 939 -~=1, selected box mode; 940 - 941 -~=2, selected gray mode; 942 - 943 -~=3, mouse selected mode; 944 -))) 945 -|=(% style="width: 160px;" %)HSW1894|(% colspan="1" style="width:282px" %)Enable a specific serial keyboard|(% style="width:452px" %)((( 946 -~=1 Enable; 947 - 948 -~=Other, not enabled; 949 - 950 -Note: Only valid for initialization, recommended to use in background initialization script; 951 -))) 952 -|=(% style="width: 160px;" %)HSW1895|(% colspan="1" style="width:282px" %)Controls whether keyboard keys are effective in certain situations|(% style="width:452px" %)((( 953 -~=0, by default, the key trigger does not take effect when the screen is off or in screen saver mode; 954 - 955 -~=1, HSX1895.0=1, the key trigger will also take effect when the screen is off; 956 - 957 -~=2, HSX1895.1=1, the key trigger will also take effect in screen saver mode; 958 -))) 959 -|=(% style="width: 160px;" %)HSW1903|(% colspan="1" style="width:282px" %)Check the network cable connection status|(% style="width:452px" %)If a network cable is detected, it is set to 1; if no network cable is detected, it is set to 0 960 960 |=(% style="width: 160px;" %)HSW10000~~19999|(% style="width:282px" %)Power-down storage area|(% style="width:452px" %)After restart, the data remains 961 961 |=(% style="width: 160px;" %)HSW10035|(% rowspan="13" style="width:282px" %)((( 962 962 Note: Valid when Ethernet1 of HMI is plugged into the network cable. ... ... @@ -1028,7 +1028,7 @@ 1028 1028 |=(% style="width: 160px;" %)HSW10606|(% style="width:282px" %)Printer instruction type|(% style="width:452px" %)((( 1029 1029 * =1: Graphic print type 1030 1030 * =2: Dot density printing type 1031 -* =3 (Default value): special for EPSON printer981 +* =3: special for EPSON printer 1032 1032 ))) 1033 1033 |=(% style="width: 160px;" %)HSW10607|(% style="width:282px" %)Printer paper cutting function|(% style="width:452px" %)((( 1034 1034 * =1: Enable ... ... @@ -1039,7 +1039,7 @@ 1039 1039 * =2: Center alignment 1040 1040 * =3: Right alignment 1041 1041 ))) 1042 -|=(% style="width: 160px;" %)HSW1061 1|(% style="width:282px" %)Set weconcloud server|(% style="width:452px" %)(((992 +|=(% style="width: 160px;" %)HSW10610|(% style="width:282px" %)Set weconcloud server|(% style="width:452px" %)((( 1043 1043 * =0: Select the server configured in "Project Settings" 1044 1044 * =1: select Server 1 1045 1045 * =2: select Server 2 ... ... @@ -1049,12 +1049,6 @@ 1049 1049 * =1: English 1050 1050 * =2: Chinese 1051 1051 ))) 1052 -|=(% style="width: 160px;" %)HSW11752|(% style="width:282px" %)Traffic monitoring control|(% style="width:452px" %)= 1: Enable the flow monitoring function 1053 -~= Other: Disable the flow monitoring function 1054 -|=(% style="width: 160px;" %)HSW11753|(% style="width:282px" %)Traffic monitoring network card type|(% style="width:452px" %)= 0: Ethernet card 1055 -~= 1: 4G 1056 -~= 2: Wi-Fi 1057 -|=(% style="width: 160px;" %)HSW11754-11755|(% style="width:282px" %)Historical traffic consumption|(% style="width:452px" %)The total traffic consumed historically (bytes) [value is an integer] 1058 1058 |=(% style="width: 160px;" %)HSW11756|(% style="width:282px" %)((( 1059 1059 Access permission restrictions 1060 1060 ... ... @@ -1105,17 +1105,7 @@ 1105 1105 )))|(% style="width:452px" %)((( 1106 1106 ~=0: Raster,=1: Blinds,=2: Bubble 1107 1107 ))) 1108 -|=(% style="width: 160px;" %)HSW11767|(% style="width:282px" %)Remote screen display adaptation mode switching|(% style="width:452px" %)=0, default mode, remote full-screen zoom display for horizontal screen projects, remote proportional zoom display for vertical screen projects; 1109 -~=1, full-screen zoom display; 1110 -~=2, proportional zoom display according to screen size ratio; 1111 -~=3, no zoom display according to screen pixels; 1112 -|=(% style="width: 160px;" %)HSW11773|(% style="width:282px" %)Automatically log out user control address|(% style="width:452px" %)=3: that is, HSX11773.0=1, HSX11773.1=1, based on the configuration in the address, enable automatic user logout. 1113 -|=(% style="width: 160px;" %)HSW11774|(% style="width:282px" %)Automatic user logout interval|(% style="width:452px" %)((( 1114 -Range: 1 to 255 1115 1115 1116 -Unit: Minutes 1117 -))) 1118 - 1119 1119 == Serial port communication configuration == 1120 1120 1121 1121 (% class="table-bordered" %)