Changes for page 13 HMI Internal Registers
Last modified by Jett on 2025/04/28 16:07
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Stone1 +XWiki.Bob - Content
-
... ... @@ -4,11 +4,11 @@ 4 4 5 5 *HSW, HDW, HUW, HAW are word address, HSX, HDX, HUX, HAX are bit address. 6 6 7 - 1.**System data area (HSW): **A special register defined by the system.8 - 1.**Data storage area (HDW/HDX): **Users store user data.9 - 1.**System data area (HUW): **A special register defined by the system.10 - 1.**System Data (HAW)**: System register used for power-off save.11 - 1.**Recipe index area (RPW): **System register used for recipe index.7 +* **System data area (HSW): **A special register defined by the system. 8 +* **Data storage area (HDW/HDX): **Users store user data. 9 +* **System data area (HUW): **A special register defined by the system. 10 +* **System Data (HAW)**: System register used for power-off save. 11 +* **Recipe index area (RPW): **System register used for recipe index. 12 12 13 13 HMI internal registers are divided into bit address and word address, which can be accessed in two ways (take HDW as an example). 14 14 ... ... @@ -339,9 +339,11 @@ 339 339 * HDX882.1=0 SD card doesn't execute storage or storage finished. 340 340 * HDX882.1=1 SD card is reading data, don't remove SD card. 341 341 ))) 342 -|=(% style="width: 160px;" %)HSW884|(% style="width:282px" %)Enter setup screen|(% style="width:452px" %)((( 343 -* = 0: Do not into setup screen 344 -* = 1: Enter setup screen 342 +|=(% style="width: 160px;" %)HSW884|(% style="width:282px" %)Enter the system network configuration interface|(% style="width:452px" %)((( 343 +* =0: Do not enter the network configuration interface 344 +* =1: Enter the system network configuration interface. 345 +** ig series HMI only supports to enter the system interface 346 + 345 345 ))) 346 346 |=(% style="width: 160px;" %)HSW885|(% style="width:282px" %)When the control object hides the address is read failed (communication failure), set the display mode of the object|(% style="width:452px" %)((( 347 347 * = 0: displayed by object setting. ... ... @@ -510,6 +510,10 @@ 510 510 * HSX1502.0=1: Modification comfirmed. Save the data of HSW1450~~HSW1501 to a file for immediate effect. 511 511 * HSX1502.1=1:Modification cancelled. Restore the current data of hSW1450-HSW1501 to the data saved in the file last time. 512 512 ))) 515 +|=(% style="width: 160px;" %)HSW1509|(% style="width:282px" %)Curve width|(% style="width:452px" %)((( 516 +* =0: Use the curve width set by project default. 517 +* =1 to 10: use special register to set curve width. 518 +))) 513 513 |=(% style="width: 160px;" %)HSW1603|(% style="width:282px" %)Number of current unreleased alarms|(% style="width:452px" %)The number of current unreleased alarms in alarm record file. 514 514 |=(% style="width: 160px;" %)HSW1604|(% style="width:282px" %)The auxiliary judgment address when the control bit in the Object Lock fails to be read|(% style="width:452px" %)((( 515 515 * =0: The auxiliary address is invalid. ... ... @@ -612,6 +612,174 @@ 612 612 * =1: Server connection is OK 613 613 ))) 614 614 |=(% style="width: 160px;" %)HSW1761|(% style="width:282px" %)Display 4G network signal strength|(% style="width:452px" %)Signal strength: 0~~31. The greater the value ,the signal is stronger 621 +|=(% style="width: 160px;" %)((( 622 +HSW1762 623 +)))|(% colspan="1" rowspan="13" style="width:282px" %)((( 624 +Note: Valid when Ethernet2 of HMI is plugged into the network cable. 625 +①、When the Ethernet setting is enabled in the project parameters, this register displays the set value. 626 +②. When the Ethernet setting is not enabled in the engineering parameters, the register displays the Ethernet IP automatically acquired by the HMI. 627 +③. When the HMI is not plugged into the network cable, the register will show 0 whether the engineering parameters are set or not. 628 +④.IP related registers can be read and written (only static IP mode can be written). 629 +)))|(% style="width:452px" %)((( 630 +Ethernet2 Local IP address high byte 1 631 +))) 632 +|=(% style="width: 160px;" %)((( 633 +HSW1763 634 +)))|(% style="width:452px" %)((( 635 +Ethernet2 Local IP address high byte 2 636 +))) 637 +|=(% style="width: 160px;" %)((( 638 +HSW1764 639 +)))|(% style="width:452px" %)((( 640 +Ethernet2 Local IP address high byte 3 641 +))) 642 +|=(% style="width: 160px;" %)((( 643 +HSW1765 644 +)))|(% style="width:452px" %)((( 645 +Ethernet2 Local IP address high byte 4 646 +))) 647 +|=(% style="width: 160px;" %)((( 648 +HSW1766 649 +)))|(% style="width:452px" %)((( 650 +Ethernet2 Local mask IP address high byte 1 651 +))) 652 +|=(% style="width: 160px;" %)((( 653 +HSW1767 654 +)))|(% style="width:452px" %)((( 655 +Ethernet2 Local mask IP address high byte 2 656 +))) 657 +|=(% style="width: 160px;" %)((( 658 +HSW1768 659 +)))|(% style="width:452px" %)Ethernet2 Local mask IP address high byte 3 660 +|=(% style="width: 160px;" %)HSW1769|(% style="width:452px" %)Ethernet2 Local mask IP address high byte 4 661 +|=(% style="width: 160px;" %)((( 662 +HSW1770 663 +)))|(% style="width:452px" %)((( 664 +Ethernet2 Local gateway IP address high byte 1 665 +))) 666 +|=(% style="width: 160px;" %)((( 667 +HSW1771 668 +)))|(% style="width:452px" %)((( 669 +Ethernet2 Local gateway IP address high byte 2 670 +))) 671 +|=(% style="width: 160px;" %)((( 672 +HSW1772 673 +)))|(% style="width:452px" %)((( 674 +Ethernet2 Local gateway IP address high byte 3 675 +))) 676 +|=(% style="width: 160px;" %)((( 677 +HSW1773 678 +)))|(% style="width:452px" %)((( 679 +Ethernet2 Local gateway IP address high byte 4 680 +))) 681 +|=(% style="width: 160px;" %)((( 682 +HSW1774 683 +)))|(% style="width:452px" %)((( 684 +Ethernet2 Local Port Address 685 +))) 686 +|=(% style="width: 160px;" %)((( 687 +HSW1775 688 +)))|(% colspan="1" rowspan="6" style="width:282px" %)((( 689 +①Display the MAC code of Ethernet2 NIC 690 + 691 +(hexadecimal display) 692 + 693 +②Read-only mode, not modifiable 694 +)))|(% style="width:452px" %)((( 695 +Ethernet2 Local MAC code high byte 1 696 +))) 697 +|=(% style="width: 160px;" %)((( 698 +HSW1776 699 +)))|(% style="width:452px" %)((( 700 +Ethernet2 Local MAC code high byte 2 701 +))) 702 +|=(% style="width: 160px;" %)((( 703 +HSW1777 704 +)))|(% style="width:452px" %)((( 705 +Ethernet2 Local MAC code high byte 3 706 +))) 707 +|=(% style="width: 160px;" %)((( 708 +HSW1778 709 +)))|(% style="width:452px" %)((( 710 +Ethernet2 Local MAC code high byte 4 711 +))) 712 +|=(% style="width: 160px;" %)((( 713 +HSW1779 714 +)))|(% style="width:452px" %)((( 715 +Ethernet2 Local MAC code high byte 5 716 +))) 717 +|=(% style="width: 160px;" %)((( 718 +HSW1780 719 +)))|(% style="width:452px" %)((( 720 +Ethernet2 Local MAC code high byte 6 721 +))) 722 +|=(% style="width: 160px;" %)((( 723 +HSW1781 724 +)))|(% colspan="1" rowspan="8" style="width:282px" %)((( 725 +①Display and modify DNS1 and DNS2 of Ethernet2 726 + 727 +②Related registers can be read and written mode (only static IP mode can be written) 728 +)))|(% style="width:452px" %)((( 729 +Ethernet2 Local DNS1 address high byte 1 730 +))) 731 +|=(% style="width: 160px;" %)((( 732 +HSW1782 733 +)))|(% style="width:452px" %)((( 734 +Ethernet2 Local DNS1 address high byte 2 735 +))) 736 +|=(% style="width: 160px;" %)((( 737 +HSW1783 738 +)))|(% style="width:452px" %)((( 739 +Ethernet2 Local DNS1 address high byte 3 740 +))) 741 +|=(% style="width: 160px;" %)((( 742 +HSW1784 743 +)))|(% style="width:452px" %)((( 744 +Ethernet2 Local DNS1 address high byte 4 745 +))) 746 +|=(% style="width: 160px;" %)((( 747 +HSW1785 748 +)))|(% style="width:452px" %)((( 749 +Ethernet2 Local DNS2 address high byte 1 750 +))) 751 +|=(% style="width: 160px;" %)((( 752 +HSW1786 753 +)))|(% style="width:452px" %)((( 754 +Ethernet2 Local DNS2 address high byte 2 755 +))) 756 +|=(% style="width: 160px;" %)((( 757 +HSW1787 758 +)))|(% style="width:452px" %)((( 759 +Ethernet2 Local DNS2 address high byte 3 760 +))) 761 +|=(% style="width: 160px;" %)((( 762 +HSW1788 763 +)))|(% style="width:452px" %)((( 764 +Ethernet2 Local DNS2 address high byte 4 765 +))) 766 +|=(% style="width: 160px;" %)((( 767 +HSW1789 768 +)))|(% colspan="1" style="width:282px" %)((( 769 +Display or set the dynamic or static IP mode of Ethernet2 770 +)))|(% style="width:452px" %)((( 771 +HSX1789.0 = 0, Static IP mode 772 + 773 +HSX1789.0 = 1, dynamic IP mode 774 +))) 775 +|=(% style="width: 160px;" %)((( 776 +HSW1790 777 +)))|(% colspan="1" style="width:282px" %)((( 778 +Confirm Ethernet2 IP, subnet mask, gateway, DNS1, DNS2, and dynamic static IP settings 779 +)))|(% style="width:452px" %)((( 780 +~= 1, confirm the setting (i.e., after modifying IP-related information, set this address to 1, representing confirmation of the modification, after which it will be reset to 0) 781 +))) 782 +|=(% style="width: 160px;" %)((( 783 +HSW1791 784 +)))|(% colspan="1" style="width:282px" %)((( 785 +Network status of the Ethernet2 connection server 786 +)))|(% style="width:452px" %)((( 787 +~= 0, connection to the server is abnormal = 1, connection to the server is normal 788 +))) 615 615 |=(% style="width: 160px;" %)HSW1852|(% style="width:282px" %)Control the interval in two consecutive clicks|(% style="width:452px" %)Limit range: 1~~500ms. The default is 100 ms. 616 616 |=(% style="width: 160px;" %)HSW1853|(% style="width:282px" %)File format for exporting data records to USB flash drive or SD card|(% style="width:452px" %)((( 617 617 * =0: db database ... ... @@ -637,14 +637,87 @@ 637 637 * =1: download firmware 638 638 * =2: enter the background 639 639 ))) 814 +|=(% style="width: 160px;" %)HSW1865|(% style="width:282px" %)Priority connection to the cloud|(% style="width:452px" %)((( 815 +* =0: priority Ethernet 816 +* =1: priority WLAN 817 +* =2: priority 4G 818 +))) 819 +|=(% style="width: 160px;" %)HSW1866|(% style="width:282px" %)Delete the LUa extension module file|(% style="width:452px" %)((( 820 +* =0: delete; 821 +* = Others: do not delete 822 +))) 823 +|=(% style="width: 160px;" %)HSW1867|(% style="width:282px" %)Reset mode|(% style="width:452px" %)((( 824 +Monitor address is set during reset of reset switch, whether to cancel reset, 825 + 826 +* = 0: yes (default); 827 +* = 1: no 828 +))) 829 +|=(% style="width: 160px;" %)HSW1868|(% style="width:282px" %)Double-click or long press the record type table mode|(% style="width:452px" %)((( 830 +Controls whether the button pops up when double-clicking or long pressing on record type table object 831 + 832 +* = 0: yes (default); 833 +* = 1: no 834 +))) 835 +|=(% style="width: 160px;" %)((( 836 +HSW1869 837 +)))|(% style="width:282px" %)((( 838 +Dynamic screensaver countdown 839 +)))|(% style="width:452px" %)((( 840 +Countdown to enter dynamic screensaver effect, unit (S) 841 +))) 842 +|=(% style="width: 160px;" %)((( 843 +HSW1870 844 +)))|(% style="width:282px" %)((( 845 +Display or set the dynamic or static IP mode of Ethernet1 846 +)))|(% style="width:452px" %)((( 847 +HSX1870.0 = 0, Static IP mode 848 + 849 +HSX1870.0 = 1, dynamic IP mode 850 +))) 851 +|=(% style="width: 160px;" %)((( 852 +HSW1871 853 +)))|(% style="width:282px" %)((( 854 +Confirm the IP, subnet mask, gateway, DNS1, DNS2, and dynamic static IP settings for Ethernet1 855 +)))|(% style="width:452px" %)((( 856 +~= 1, confirm the setting (i.e., after modifying IP-related information, set this address to 1, representing confirmation of the modification, after which it will be reset to 0) 857 +))) 858 +|=(% style="width: 160px;" %)((( 859 +HSW1872 860 +)))|(% colspan="1" rowspan="8" style="width:282px" %)((( 861 +①Display and modify DNS1 and DNS2 of Ethernet1 862 + 863 +②Related registers can be read and written mode (only static IP mode can be written) 864 +)))|(% style="width:452px" %)((( 865 +Ethernet1 Local DNS1 address high byte 1 866 +))) 867 +|=(% style="width: 160px;" %)((( 868 +HSW1873 869 +)))|(% style="width:452px" %)Ethernet1 Local DNS1 address high byte 2 870 +|=(% style="width: 160px;" %)((( 871 +HSW1874 872 +)))|(% style="width:452px" %)Ethernet1 Local DNS1 address high byte 3 873 +|=(% style="width: 160px;" %)((( 874 +HSW1875 875 +)))|(% style="width:452px" %)Ethernet1 Local DNS1 address high byte 4 876 +|=(% style="width: 160px;" %)((( 877 +HSW1876 878 +)))|(% style="width:452px" %)Ethernet1 Local DNS2 address high byte 1 879 +|=(% style="width: 160px;" %)((( 880 +HSW1877 881 +)))|(% style="width:452px" %)Ethernet1 Local DNS2 address high byte 2 882 +|=(% style="width: 160px;" %)((( 883 +HSW1878 884 +)))|(% style="width:452px" %)Ethernet1 Local DNS2 address high byte 3 885 +|=(% style="width: 160px;" %)((( 886 +HSW1879 887 +)))|(% style="width:452px" %)Ethernet1 Local DNS2 address high byte 4 640 640 |=(% style="width: 160px;" %)HSW10000~~19999|(% style="width:282px" %)Power-down storage area|(% style="width:452px" %)After restart, the data remains 641 641 |=(% style="width: 160px;" %)HSW10035|(% rowspan="13" style="width:282px" %)((( 642 -**✎Note: **Only valid when the HMI is plugged into the Ethernet cable. 643 - 644 -1. If Ethernet settings is enabled in project parameters, this register displays the set value. 645 -1. If Ethernet settings is not enabled in project parameters, IP would automatically obtained IP. 646 -1. If HMI is not connected to the network, the register is displayed as 0 whether the engineering parameters are set. 647 -1. 4. All IP registers of HMI are read-only. 890 +Note: Valid when Ethernet1 of HMI is plugged into the network cable. 891 +①、When the Ethernet setting is enabled in the project parameters, this register displays the set value. 892 +②. When the Ethernet setting is not enabled in the engineering parameters, the register displays the Ethernet IP automatically acquired by the HMI. 893 +③. When the HMI is not plugged into the network cable, the register will show 0 whether the engineering parameters are set or not. 894 +④.IP related registers can be read and written (only static IP mode can be written). 648 648 )))|(% style="width:452px" %)Local IP address high byte 1 649 649 |=(% style="width: 160px;" %)HSW10036|(% style="width:452px" %)Local IP address high byte 2 650 650 |=(% style="width: 160px;" %)HSW10037|(% style="width:452px" %)Local IP address high byte 3 ... ... @@ -659,9 +659,11 @@ 659 659 |=(% style="width: 160px;" %)HSW10046|(% style="width:452px" %)Local gateway address high byte 4 660 660 |=(% style="width: 160px;" %)HSW10047|(% style="width:452px" %)Local port address 661 661 |=(% style="width: 160px;" %)HSW10048|(% rowspan="6" style="width:282px" %)((( 662 -Display sthe MAC code of thecurrent networkcard909 +①Display the MAC code of Ethernet1 NIC 663 663 664 -(Hexadecimal display) 911 +(hexadecimal display) 912 + 913 +②Read-only mode, not modifiable 665 665 )))|(% style="width:452px" %)Local MAC code high word 1 666 666 |=(% style="width: 160px;" %)HSW10049|(% style="width:452px" %)Local MAC code high word 2 667 667 |=(% style="width: 160px;" %)HSW10050|(% style="width:452px" %)Local MAC code high word 3 ... ... @@ -750,11 +750,32 @@ 750 750 ))) 751 751 |=(% style="width: 160px;" %)HSW11760|(% style="width:282px" %)Screensaver countdown|(% style="width:452px" %)Display the countdown to enter the Screensaver, unit: second. 752 752 |=(% style="width: 160px;" %)HSW11761|(% style="width:282px" %)Screensaver screen number|(% style="width:452px" %)Set the screen number for Screensaver 1002 +|=(% style="width: 160px;" %)((( 1003 +HSW11762 1004 +)))|(% style="width:282px" %)((( 1005 +Dynamic screensaver control address 1006 +)))|(% style="width:452px" %)((( 1007 +HSX11762.0: =0, initialize with project configuration; =1, initialize with special register configuration; HSX11762.1: =0, disable dynamic screensaver; =1, enable dynamic screensaver 1008 +))) 1009 +|=(% style="width: 160px;" %)((( 1010 +HSW11763 1011 +)))|(% style="width:282px" %)((( 1012 +Waiting time to enter the dynamic screensaver 1013 +)))|(% style="width:452px" %)((( 1014 +Waiting time when the screen is not operated, range 1~~720 minutes 1015 +))) 1016 +|=(% style="width: 160px;" %)((( 1017 +HSW11764 1018 +)))|(% style="width:282px" %)((( 1019 +Animated screensaver animation type 1020 +)))|(% style="width:452px" %)((( 1021 +~=0:lattice,=1:shutter,=2:bubble 1022 +))) 753 753 754 -== **Serial port communication configuration**==1024 +== Serial port communication configuration == 755 755 756 756 (% class="table-bordered" %) 757 -|=(% style="width: 102px;" %)Port|=(% style="width: 173px;" %)**Function**|=(% style="width: 122px;" %)**Address**|=(% colspan="2" style="width: 506px;" %)**Description** 1027 +|=(% scope="row" style="width: 102px;" %)Port|=(% style="width: 173px;" %)**Function**|=(% style="width: 122px;" %)**Address**|=(% colspan="2" style="width: 506px;" %)**Description** 758 758 |(% colspan="1" rowspan="11" style="width:102px" %)COM1|(% style="width:173px" %)Communication mode|(% style="width:122px" %)HSW10061|(% colspan="2" style="width:506px" %)((( 759 759 * =0: RS232 760 760 * =1: RS485 ... ... @@ -784,10 +784,22 @@ 784 784 * =1: ODD 785 785 * =2: EVEN 786 786 ))) 787 -|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10066|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000 788 -|(% style="width:173px" %)reveive timeout|(% style="width:122px" %)HSW10067|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000 789 -|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10068|(% colspan="2" style="width:506px" %)Unit: times. Range: 0~~100 790 -|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10069|(% colspan="2" style="width:506px" %)Unit: s. Range: 0~~300 1057 +|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10066|(% colspan="2" style="width:506px" %)((( 1058 +* Unit: ms. 1059 +* Range: 0 to 30000 1060 +))) 1061 +|(% style="width:173px" %)reveive timeout|(% style="width:122px" %)HSW10067|(% colspan="2" style="width:506px" %)((( 1062 +* Unit: ms. 1063 +* Range: 0 to 30000 1064 +))) 1065 +|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10068|(% colspan="2" style="width:506px" %)((( 1066 +* Unit: times. 1067 +* Range: 0 to 100 1068 +))) 1069 +|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10069|(% colspan="2" style="width:506px" %)((( 1070 +* Unit: s. 1071 +* Range: 0 to 300 1072 +))) 791 791 |(% style="width:173px" %)HMI station number|(% style="width:122px" %)HSW10070|(% colspan="2" style="width:506px" %) 792 792 |(% style="width:173px" %)PLC station number|(% style="width:122px" %)HSW10071|(% colspan="2" style="width:506px" %) 793 793 |(% colspan="1" rowspan="11" style="width:102px" %)COM1-2|(% style="width:173px" %)Communication mode|(% style="width:122px" %)HSW10094|(% colspan="2" style="width:506px" %)((( ... ... @@ -820,10 +820,22 @@ 820 820 * =1: ODD 821 821 * =2: EVEN 822 822 ))) 823 -|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10099|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000 824 -|(% style="width:173px" %)receive timeout|(% style="width:122px" %)HSW10100|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000 825 -|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10101|(% colspan="2" style="width:506px" %)Unit: times. Range: 0~~100 826 -|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10102|(% colspan="2" style="width:506px" %)Unit: s. Range: 0~~30 1105 +|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10099|(% colspan="2" style="width:506px" %)((( 1106 +* Unit: ms. 1107 +* Range: 0 to 30000 1108 +))) 1109 +|(% style="width:173px" %)receive timeout|(% style="width:122px" %)HSW10100|(% colspan="2" style="width:506px" %)((( 1110 +* Unit: ms. 1111 +* Range: 0 to 30000 1112 +))) 1113 +|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10101|(% colspan="2" style="width:506px" %)((( 1114 +* Unit: times. 1115 +* Range: 0 to 100 1116 +))) 1117 +|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10102|(% colspan="2" style="width:506px" %)((( 1118 +* Unit: s. 1119 +* Range: 0 to 30 1120 +))) 827 827 |(% style="width:173px" %)HMI station number|(% style="width:122px" %)HSW10103|(% colspan="2" style="width:506px" %) 828 828 |(% style="width:173px" %)PLC station number|(% style="width:122px" %)HSW10104|(% colspan="2" style="width:506px" %) 829 829 |(% colspan="1" rowspan="11" style="width:102px" %)COM1-3|(% style="width:173px" %)Communication mode|(% style="width:122px" %)HSW10120|(% colspan="2" style="width:506px" %)((( ... ... @@ -856,10 +856,22 @@ 856 856 * =1: ODD 857 857 * =2: EVEN 858 858 ))) 859 -|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10125|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000 860 -|(% style="width:173px" %)receive timeout|(% style="width:122px" %)HSW10126|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000 861 -|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10127|(% colspan="2" style="width:506px" %)Unit: times. Range: 0~~100 862 -|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10128|(% colspan="2" style="width:506px" %)Unit: s. Range: 0~~30 1153 +|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10125|(% colspan="2" style="width:506px" %)((( 1154 +* Unit: ms. 1155 +* Range: 0 to 30000 1156 +))) 1157 +|(% style="width:173px" %)receive timeout|(% style="width:122px" %)HSW10126|(% colspan="2" style="width:506px" %)((( 1158 +* Unit: ms. 1159 +* Range: 0 to 30000 1160 +))) 1161 +|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10127|(% colspan="2" style="width:506px" %)((( 1162 +* Unit: times. 1163 +* Range: 0 to 100 1164 +))) 1165 +|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10128|(% colspan="2" style="width:506px" %)((( 1166 +* Unit: s. 1167 +* Range: 0 to 30 1168 +))) 863 863 |(% style="width:173px" %)HMI station number|(% style="width:122px" %)HSW10129|(% colspan="2" style="width:506px" %) 864 864 |(% style="width:173px" %)PLC station number|(% style="width:122px" %)HSW10130|(% colspan="2" style="width:506px" %) 865 865 |(% colspan="1" rowspan="11" style="width:102px" %)COM2|(% style="width:173px" %)Communication mode|(% style="width:122px" %)HSW10072|(% colspan="2" style="width:506px" %)((( ... ... @@ -890,10 +890,22 @@ 890 890 * =1: ODD 891 891 * =2: EVEN 892 892 ))) 893 -|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10077|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000 894 -|(% style="width:173px" %)receive timeout|(% style="width:122px" %)HSW10078|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000 895 -|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10079|(% colspan="2" style="width:506px" %)Unit: times. Range: 0~~100 896 -|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10080|(% colspan="2" style="width:506px" %)Unit: s. Range: 0~~30 1199 +|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10077|(% colspan="2" style="width:506px" %)((( 1200 +* Unit: ms. 1201 +* Range: 0 to 30000 1202 +))) 1203 +|(% style="width:173px" %)receive timeout|(% style="width:122px" %)HSW10078|(% colspan="2" style="width:506px" %)((( 1204 +* Unit: ms. 1205 +* Range: 0 to 30000 1206 +))) 1207 +|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10079|(% colspan="2" style="width:506px" %)((( 1208 +* Unit: times. 1209 +* Range: 0 to 100 1210 +))) 1211 +|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10080|(% colspan="2" style="width:506px" %)((( 1212 +* Unit: s. 1213 +* Range: 0 to 30 1214 +))) 897 897 |(% style="width:173px" %)HMI station number|(% style="width:122px" %)HSW10081|(% colspan="2" style="width:506px" %) 898 898 |(% style="width:173px" %)PLC station number|(% style="width:122px" %)HSW10082|(% colspan="2" style="width:506px" %) 899 899 |(% colspan="1" rowspan="11" style="width:102px" %)COM2-2|(% style="width:173px" %)Communication mode|(% style="width:122px" %)HSW10105|(% colspan="2" style="width:506px" %)((( ... ... @@ -924,10 +924,22 @@ 924 924 * =1: ODD 925 925 * =2: EVEN 926 926 ))) 927 -|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10110|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000 928 -|(% style="width:173px" %)receive timeout|(% style="width:122px" %)HSW10111|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000 929 -|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10112|(% colspan="2" style="width:506px" %)Unit: times. Range: 0~~100 930 -|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10113|(% colspan="2" style="width:506px" %)Unit: s. Range: 0~~30 1245 +|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10110|(% colspan="2" style="width:506px" %)((( 1246 +* Unit: ms. 1247 +* Range: 0 to 30000 1248 +))) 1249 +|(% style="width:173px" %)receive timeout|(% style="width:122px" %)HSW10111|(% colspan="2" style="width:506px" %)((( 1250 +* Unit: ms. 1251 +* Range: 0 to 30000 1252 +))) 1253 +|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10112|(% colspan="2" style="width:506px" %)((( 1254 +* Unit: times. 1255 +* Range: 0 to 100 1256 +))) 1257 +|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10113|(% colspan="2" style="width:506px" %)((( 1258 +* Unit: s. 1259 +* Range: 0 to 30 1260 +))) 931 931 |(% style="width:173px" %)HMI station number|(% style="width:122px" %)HSW10114|(% colspan="2" style="width:506px" %) 932 932 |(% style="width:173px" %)PLC station number|(% style="width:122px" %)HSW10115|(% colspan="2" style="width:506px" %) 933 933 |(% colspan="1" rowspan="11" style="width:102px" %)COM3|(% style="width:173px" %)Communication mode|(% style="width:122px" %)HSW10083|(% colspan="2" style="width:506px" %)((( ... ... @@ -957,29 +957,48 @@ 957 957 * =1: ODD 958 958 * =2: EVEN 959 959 ))) 960 -|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10088|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000 961 -|(% style="width:173px" %)receive timeout|(% style="width:122px" %)HSW10089|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000 962 -|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10090|(% colspan="2" style="width:506px" %)Unit: times. Range: 0~~100 963 -|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10091|(% colspan="2" style="width:506px" %)Unit: s. Range: 0~~30 1290 +|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10088|(% colspan="2" style="width:506px" %)((( 1291 +* Unit: ms. 1292 +* Range: 0 to 30000 1293 +))) 1294 +|(% style="width:173px" %)receive timeout|(% style="width:122px" %)HSW10089|(% colspan="2" style="width:506px" %)((( 1295 +* Unit: ms. 1296 +* Range: 0 to 30000 1297 +))) 1298 +|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10090|(% colspan="2" style="width:506px" %)((( 1299 +* Unit: times. 1300 +* Range: 0 to 100 1301 +))) 1302 +|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10091|(% colspan="2" style="width:506px" %)((( 1303 +* Unit: s. 1304 +* Range: 0 to 30 1305 +))) 964 964 |(% style="width:173px" %)HMI station number|(% style="width:122px" %)HSW10092|(% colspan="2" style="width:506px" %) 965 965 |(% style="width:173px" %)PLC station number|(% style="width:122px" %)HSW10093|(% colspan="2" style="width:506px" %) 966 966 |(% colspan="1" rowspan="2" style="width:102px" %)CAN port|(% style="width:173px" %)CAN1 baud rate|(% style="width:122px" %)HSW010116|(% style="width:299px" %)((( 967 -Unit: K, the baud rate must be an integer, for example, when the baud rate required is 250000, just enter 250. 1309 +Unit: K, the baud rate must be an integer. 1310 + 1311 +For example, when the baud rate required is 250000, just enter 250. 968 968 )))|(% colspan="1" rowspan="2" style="width:218px" %)**✎Note: **If baud rate has been modified,please wait 5 seconds,then restart the HMI to take effect. 969 -|(% style="width:173px" %)CAN2 baud rate|(% style="width:122px" %)HSW010117|(% style="width:299px" %)Unit: K, the baud rate must be an integer, for example, when the baud rate required is 250000, just enter 250. 1313 +|(% style="width:173px" %)CAN2 baud rate|(% style="width:122px" %)HSW010117|(% style="width:299px" %)((( 1314 +Unit: K, the baud rate must be an integer. 970 970 971 -== **Ethernet communication configuration** == 1316 +For example, when the baud rate required is 250000, just enter 250. 1317 +))) 972 972 1319 +== Ethernet communication configuration == 1320 + 973 973 (% class="table-bordered" %) 974 -| =(% style="width:;" %)**No.**|=(% style="width:;" %)**Function**|=(% style="width:;" %)**Address**|=(% style="width:;" %)**Description**1322 +|(% style="width:40px" %)**No.**|(% style="width:295px" %)**Function**|(% style="width:220px" %)**Address**|(% style="width:336px" %)**Description** 975 975 |(% rowspan="7" style="width:40px" %)1|(% colspan="1" rowspan="7" style="width:295px" %)Ethernet parameter configuration for communication number 1 in list. Configure those addresses according to connected device. After configuration, wait for 5 seconds and restart the HMI.|(% style="width:220px" %)HSW11004|(% style="width:336px" %)Device IP address high word 1 976 976 |(% style="width:220px" %)HSW11005|(% style="width:336px" %)Device IP address high word 2 977 977 |(% style="width:220px" %)HSW11006|(% style="width:336px" %)Device IP address high word 3 978 978 |(% style="width:220px" %)HSW11007|(% style="width:336px" %)Device IP address high word 4 979 979 |(% style="width:220px" %)HSW11008|(% style="width:336px" %)Device Port number 980 -|(% style="width:220px" %)HSW11009|=(% style="width: 336px;" %)((( 981 -* =2 TCP 982 -* =3 UDP 1328 +|(% style="width:220px" %)HSW11009|(% style="width:336px" %)((( 1329 +~=2 TCP 1330 + 1331 +~=3 UDP 983 983 ))) 984 984 |(% style="width:220px" %)HSW11010|(% style="width:336px" %)Reserved 985 985 |(% rowspan="7" style="width:40px" %)2|(% colspan="1" rowspan="7" style="width:295px" %)Ethernet parameter configuration for communication number 2 in list. Configure those addresses according to connected device. After configuration, wait for 5 seconds and restart the HMI.|(% style="width:220px" %)HSW11011|(% style="width:336px" %)Device IP address high word 1 ... ... @@ -987,9 +987,10 @@ 987 987 |(% style="width:220px" %)HSW11013|(% style="width:336px" %)Device IP address high word 3 988 988 |(% style="width:220px" %)HSW11014|(% style="width:336px" %)Device IP address high word 4 989 989 |(% style="width:220px" %)HSW11015|(% style="width:336px" %)Device Port number 990 -|(% style="width:220px" %)HSW11016|=(% style="width: 336px;" %)((( 991 -* =2 TCP 992 -* =3 UDP 1339 +|(% style="width:220px" %)HSW11016|(% style="width:336px" %)((( 1340 +~=2 TCP 1341 + 1342 +~=3 UDP 993 993 ))) 994 994 |(% style="width:220px" %)HSW11017|(% style="width:336px" %)Reserved 995 995 |(% style="width:40px" %)…|(% style="width:295px" %) |(% style="width:220px" %)…|(% style="width:336px" %)… ... ... @@ -998,7 +998,11 @@ 998 998 |(% style="width:220px" %)HSW11223|(% style="width:336px" %)Device IP address high word 3 999 999 |(% style="width:220px" %)HSW11224|(% style="width:336px" %)Device IP address high word 4 1000 1000 |(% style="width:220px" %)HSW11225|(% style="width:336px" %)Device Port number 1001 -|(% style="width:220px" %)HSW11226|=(% style="width: 336px;" %)2 TCP; =3 UDP 1351 +|(% style="width:220px" %)HSW11226|(% style="width:336px" %)((( 1352 +~=2 TCP; 1353 + 1354 +~=3 UDP 1355 +))) 1002 1002 |(% style="width:220px" %)HSW11227|(% style="width:336px" %)Reserved 1003 1003 1004 1004 (% class="box infomessage" %) ... ... @@ -1006,7 +1006,7 @@ 1006 1006 **✎Note:** The number of Ethernet connections supported by different HMI series varies. 1007 1007 ))) 1008 1008 1009 -== **Communication control**==1363 +== Communication control == 1010 1010 1011 1011 (% class="table-bordered" %) 1012 1012 |=(% style="width: 135px;" %)**Communication No.**|=(% style="width: 102px;" %)**Station No.**|=(% style="width: 185px;" %)**Control bit**|=(% style="width: 191px;" %)**Communication lamp**|=(% style="width: 271px;" %)**Description**