Changes for page 13 HMI Internal Registers
Last modified by Jett on 2025/04/28 16:07
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -339,9 +339,11 @@ 339 339 * HDX882.1=0 SD card doesn't execute storage or storage finished. 340 340 * HDX882.1=1 SD card is reading data, don't remove SD card. 341 341 ))) 342 -|=(% style="width: 160px;" %)HSW884|(% style="width:282px" %)Enter setup screen|(% style="width:452px" %)((( 343 -* = 0: Do not into setup screen 344 -* = 1: Enter setup screen 342 +|=(% style="width: 160px;" %)HSW884|(% style="width:282px" %)Enter the system network configuration interface|(% style="width:452px" %)((( 343 +* =0: Do not enter the network configuration interface 344 +* =1: Enter the system network configuration interface. 345 +** ig series HMI only supports to enter the system interface 346 + 345 345 ))) 346 346 |=(% style="width: 160px;" %)HSW885|(% style="width:282px" %)When the control object hides the address is read failed (communication failure), set the display mode of the object|(% style="width:452px" %)((( 347 347 * = 0: displayed by object setting. ... ... @@ -510,6 +510,10 @@ 510 510 * HSX1502.0=1: Modification comfirmed. Save the data of HSW1450~~HSW1501 to a file for immediate effect. 511 511 * HSX1502.1=1:Modification cancelled. Restore the current data of hSW1450-HSW1501 to the data saved in the file last time. 512 512 ))) 515 +|=(% style="width: 160px;" %)HSW1509|(% style="width:282px" %)Curve width|(% style="width:452px" %)((( 516 +* =0: Use the curve width set by project default. 517 +* =1 to 10: use special register to set curve width. 518 +))) 513 513 |=(% style="width: 160px;" %)HSW1603|(% style="width:282px" %)Number of current unreleased alarms|(% style="width:452px" %)The number of current unreleased alarms in alarm record file. 514 514 |=(% style="width: 160px;" %)HSW1604|(% style="width:282px" %)The auxiliary judgment address when the control bit in the Object Lock fails to be read|(% style="width:452px" %)((( 515 515 * =0: The auxiliary address is invalid. ... ... @@ -637,6 +637,22 @@ 637 637 * =1: download firmware 638 638 * =2: enter the background 639 639 ))) 646 +|=(% style="width: 160px;" %)HSW1866|(% style="width:282px" %)Delete the LUa extension module file|(% style="width:452px" %)((( 647 +* =1, delete; 648 +* = Others, do not delete 649 +))) 650 +|=(% style="width: 160px;" %)HSW1867|(% style="width:282px" %)Reset mode|(% style="width:452px" %)((( 651 +Monitor address is set during reset of reset switch, whether to cancel reset, 652 + 653 +* = 0, yes (default); 654 +* = 1, no 655 +))) 656 +|=(% style="width: 160px;" %)HSW1868|(% style="width:282px" %)Double-click or long press the record type table mode|(% style="width:452px" %)((( 657 +Controls whether the button pops up when double-clicking or long pressing on record type table object 658 + 659 +* = 0, yes (default); 660 +* = 1, no 661 +))) 640 640 |=(% style="width: 160px;" %)HSW10000~~19999|(% style="width:282px" %)Power-down storage area|(% style="width:452px" %)After restart, the data remains 641 641 |=(% style="width: 160px;" %)HSW10035|(% rowspan="13" style="width:282px" %)((( 642 642 **✎Note: **Only valid when the HMI is plugged into the Ethernet cable. ... ... @@ -754,7 +754,7 @@ 754 754 == **Serial port communication configuration** == 755 755 756 756 (% class="table-bordered" %) 757 -|=(% style="width: 102px;" %)Port|=(% style="width: 173px;" %)**Function**|=(% style="width: 122px;" %)**Address**|=(% colspan="2" style="width: 506px;" %)**Description** 779 +|=(% scope="row" style="width: 102px;" %)Port|=(% style="width: 173px;" %)**Function**|=(% style="width: 122px;" %)**Address**|=(% colspan="2" style="width: 506px;" %)**Description** 758 758 |(% colspan="1" rowspan="11" style="width:102px" %)COM1|(% style="width:173px" %)Communication mode|(% style="width:122px" %)HSW10061|(% colspan="2" style="width:506px" %)((( 759 759 * =0: RS232 760 760 * =1: RS485