Changes for page 13 HMI Internal Registers
Last modified by Jett on 2025/04/28 16:07
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Stone1 +XWiki.Bob - Content
-
... ... @@ -4,11 +4,11 @@ 4 4 5 5 *HSW, HDW, HUW, HAW are word address, HSX, HDX, HUX, HAX are bit address. 6 6 7 - 1.**System data area (HSW): **A special register defined by the system.8 - 1.**Data storage area (HDW/HDX): **Users store user data.9 - 1.**System data area (HUW): **A special register defined by the system.10 - 1.**System Data (HAW)**: System register used for power-off save.11 - 1.**Recipe index area (RPW): **System register used for recipe index.7 +* **System data area (HSW): **A special register defined by the system. 8 +* **Data storage area (HDW/HDX): **Users store user data. 9 +* **System data area (HUW): **A special register defined by the system. 10 +* **System Data (HAW)**: System register used for power-off save. 11 +* **Recipe index area (RPW): **System register used for recipe index. 12 12 13 13 HMI internal registers are divided into bit address and word address, which can be accessed in two ways (take HDW as an example). 14 14 ... ... @@ -342,7 +342,7 @@ 342 342 |=(% style="width: 160px;" %)HSW884|(% style="width:282px" %)Enter the system network configuration interface|(% style="width:452px" %)((( 343 343 * =0: Do not enter the network configuration interface 344 344 * =1: Enter the system network configuration interface. 345 -** (ig series HMI only supports to enter the system interface)345 +** ig series HMI only supports to enter the system interface 346 346 347 347 ))) 348 348 |=(% style="width: 160px;" %)HSW885|(% style="width:282px" %)When the control object hides the address is read failed (communication failure), set the display mode of the object|(% style="width:452px" %)((( ... ... @@ -512,6 +512,10 @@ 512 512 * HSX1502.0=1: Modification comfirmed. Save the data of HSW1450~~HSW1501 to a file for immediate effect. 513 513 * HSX1502.1=1:Modification cancelled. Restore the current data of hSW1450-HSW1501 to the data saved in the file last time. 514 514 ))) 515 +|=(% style="width: 160px;" %)HSW1509|(% style="width:282px" %)Curve width|(% style="width:452px" %)((( 516 +* =0: Use the curve width set by project default. 517 +* =1 to 10: use special register to set curve width. 518 +))) 515 515 |=(% style="width: 160px;" %)HSW1603|(% style="width:282px" %)Number of current unreleased alarms|(% style="width:452px" %)The number of current unreleased alarms in alarm record file. 516 516 |=(% style="width: 160px;" %)HSW1604|(% style="width:282px" %)The auxiliary judgment address when the control bit in the Object Lock fails to be read|(% style="width:452px" %)((( 517 517 * =0: The auxiliary address is invalid. ... ... @@ -614,6 +614,174 @@ 614 614 * =1: Server connection is OK 615 615 ))) 616 616 |=(% style="width: 160px;" %)HSW1761|(% style="width:282px" %)Display 4G network signal strength|(% style="width:452px" %)Signal strength: 0~~31. The greater the value ,the signal is stronger 621 +|=(% style="width: 160px;" %)((( 622 +HSW1762 623 +)))|(% colspan="1" rowspan="13" style="width:282px" %)((( 624 +Note: Valid when Ethernet2 of HMI is plugged into the network cable. 625 +①、When the Ethernet setting is enabled in the project parameters, this register displays the set value. 626 +②. When the Ethernet setting is not enabled in the engineering parameters, the register displays the Ethernet IP automatically acquired by the HMI. 627 +③. When the HMI is not plugged into the network cable, the register will show 0 whether the engineering parameters are set or not. 628 +④.IP related registers can be read and written (only static IP mode can be written). 629 +)))|(% style="width:452px" %)((( 630 +Ethernet2 Local IP address high byte 1 631 +))) 632 +|=(% style="width: 160px;" %)((( 633 +HSW1763 634 +)))|(% style="width:452px" %)((( 635 +Ethernet2 Local IP address high byte 2 636 +))) 637 +|=(% style="width: 160px;" %)((( 638 +HSW1764 639 +)))|(% style="width:452px" %)((( 640 +Ethernet2 Local IP address high byte 3 641 +))) 642 +|=(% style="width: 160px;" %)((( 643 +HSW1765 644 +)))|(% style="width:452px" %)((( 645 +Ethernet2 Local IP address high byte 4 646 +))) 647 +|=(% style="width: 160px;" %)((( 648 +HSW1766 649 +)))|(% style="width:452px" %)((( 650 +Ethernet2 Local mask IP address high byte 1 651 +))) 652 +|=(% style="width: 160px;" %)((( 653 +HSW1767 654 +)))|(% style="width:452px" %)((( 655 +Ethernet2 Local mask IP address high byte 2 656 +))) 657 +|=(% style="width: 160px;" %)((( 658 +HSW1768 659 +)))|(% style="width:452px" %)Ethernet2 Local mask IP address high byte 3 660 +|=(% style="width: 160px;" %)HSW1769|(% style="width:452px" %)Ethernet2 Local mask IP address high byte 4 661 +|=(% style="width: 160px;" %)((( 662 +HSW1770 663 +)))|(% style="width:452px" %)((( 664 +Ethernet2 Local gateway IP address high byte 1 665 +))) 666 +|=(% style="width: 160px;" %)((( 667 +HSW1771 668 +)))|(% style="width:452px" %)((( 669 +Ethernet2 Local gateway IP address high byte 2 670 +))) 671 +|=(% style="width: 160px;" %)((( 672 +HSW1772 673 +)))|(% style="width:452px" %)((( 674 +Ethernet2 Local gateway IP address high byte 3 675 +))) 676 +|=(% style="width: 160px;" %)((( 677 +HSW1773 678 +)))|(% style="width:452px" %)((( 679 +Ethernet2 Local gateway IP address high byte 4 680 +))) 681 +|=(% style="width: 160px;" %)((( 682 +HSW1774 683 +)))|(% style="width:452px" %)((( 684 +Ethernet2 Local Port Address 685 +))) 686 +|=(% style="width: 160px;" %)((( 687 +HSW1775 688 +)))|(% colspan="1" rowspan="6" style="width:282px" %)((( 689 +①Display the MAC code of Ethernet2 NIC 690 + 691 +(hexadecimal display) 692 + 693 +②Read-only mode, not modifiable 694 +)))|(% style="width:452px" %)((( 695 +Ethernet2 Local MAC code high byte 1 696 +))) 697 +|=(% style="width: 160px;" %)((( 698 +HSW1776 699 +)))|(% style="width:452px" %)((( 700 +Ethernet2 Local MAC code high byte 2 701 +))) 702 +|=(% style="width: 160px;" %)((( 703 +HSW1777 704 +)))|(% style="width:452px" %)((( 705 +Ethernet2 Local MAC code high byte 3 706 +))) 707 +|=(% style="width: 160px;" %)((( 708 +HSW1778 709 +)))|(% style="width:452px" %)((( 710 +Ethernet2 Local MAC code high byte 4 711 +))) 712 +|=(% style="width: 160px;" %)((( 713 +HSW1779 714 +)))|(% style="width:452px" %)((( 715 +Ethernet2 Local MAC code high byte 5 716 +))) 717 +|=(% style="width: 160px;" %)((( 718 +HSW1780 719 +)))|(% style="width:452px" %)((( 720 +Ethernet2 Local MAC code high byte 6 721 +))) 722 +|=(% style="width: 160px;" %)((( 723 +HSW1781 724 +)))|(% colspan="1" rowspan="8" style="width:282px" %)((( 725 +①Display and modify DNS1 and DNS2 of Ethernet2 726 + 727 +②Related registers can be read and written mode (only static IP mode can be written) 728 +)))|(% style="width:452px" %)((( 729 +Ethernet2 Local DNS1 address high byte 1 730 +))) 731 +|=(% style="width: 160px;" %)((( 732 +HSW1782 733 +)))|(% style="width:452px" %)((( 734 +Ethernet2 Local DNS1 address high byte 2 735 +))) 736 +|=(% style="width: 160px;" %)((( 737 +HSW1783 738 +)))|(% style="width:452px" %)((( 739 +Ethernet2 Local DNS1 address high byte 3 740 +))) 741 +|=(% style="width: 160px;" %)((( 742 +HSW1784 743 +)))|(% style="width:452px" %)((( 744 +Ethernet2 Local DNS1 address high byte 4 745 +))) 746 +|=(% style="width: 160px;" %)((( 747 +HSW1785 748 +)))|(% style="width:452px" %)((( 749 +Ethernet2 Local DNS2 address high byte 1 750 +))) 751 +|=(% style="width: 160px;" %)((( 752 +HSW1786 753 +)))|(% style="width:452px" %)((( 754 +Ethernet2 Local DNS2 address high byte 2 755 +))) 756 +|=(% style="width: 160px;" %)((( 757 +HSW1787 758 +)))|(% style="width:452px" %)((( 759 +Ethernet2 Local DNS2 address high byte 3 760 +))) 761 +|=(% style="width: 160px;" %)((( 762 +HSW1788 763 +)))|(% style="width:452px" %)((( 764 +Ethernet2 Local DNS2 address high byte 4 765 +))) 766 +|=(% style="width: 160px;" %)((( 767 +HSW1789 768 +)))|(% colspan="1" style="width:282px" %)((( 769 +Display or set the dynamic or static IP mode of Ethernet2 770 +)))|(% style="width:452px" %)((( 771 +HSX1789.0 = 0, Static IP mode 772 + 773 +HSX1789.0 = 1, dynamic IP mode 774 +))) 775 +|=(% style="width: 160px;" %)((( 776 +HSW1790 777 +)))|(% colspan="1" style="width:282px" %)((( 778 +Confirm Ethernet2 IP, subnet mask, gateway, DNS1, DNS2, and dynamic static IP settings 779 +)))|(% style="width:452px" %)((( 780 +~= 1, confirm the setting (i.e., after modifying IP-related information, set this address to 1, representing confirmation of the modification, after which it will be reset to 0) 781 +))) 782 +|=(% style="width: 160px;" %)((( 783 +HSW1791 784 +)))|(% colspan="1" style="width:282px" %)((( 785 +Network status of the Ethernet2 connection server 786 +)))|(% style="width:452px" %)((( 787 +~= 0, connection to the server is abnormal = 1, connection to the server is normal 788 +))) 617 617 |=(% style="width: 160px;" %)HSW1852|(% style="width:282px" %)Control the interval in two consecutive clicks|(% style="width:452px" %)Limit range: 1~~500ms. The default is 100 ms. 618 618 |=(% style="width: 160px;" %)HSW1853|(% style="width:282px" %)File format for exporting data records to USB flash drive or SD card|(% style="width:452px" %)((( 619 619 * =0: db database ... ... @@ -639,14 +639,80 @@ 639 639 * =1: download firmware 640 640 * =2: enter the background 641 641 ))) 814 +|=(% style="width: 160px;" %)HSW1865|(% style="width:282px" %)Priority connection to the cloud|(% style="width:452px" %)((( 815 +* =0: priority Ethernet 816 +* =1: priority WLAN 817 +* =2: priority 4G 818 +))) 819 +|=(% style="width: 160px;" %)HSW1866|(% style="width:282px" %)Delete the LUa extension module file|(% style="width:452px" %)((( 820 +* =0: delete; 821 +* = Others: do not delete 822 +))) 823 +|=(% style="width: 160px;" %)HSW1867|(% style="width:282px" %)Reset mode|(% style="width:452px" %)((( 824 +Monitor address is set during reset of reset switch, whether to cancel reset, 825 + 826 +* = 0: yes (default); 827 +* = 1: no 828 +))) 829 +|=(% style="width: 160px;" %)HSW1868|(% style="width:282px" %)Double-click or long press the record type table mode|(% style="width:452px" %)((( 830 +Controls whether the button pops up when double-clicking or long pressing on record type table object 831 + 832 +* = 0: yes (default); 833 +* = 1: no 834 +))) 835 +|=(% style="width: 160px;" %)((( 836 +HSW1870 837 +)))|(% style="width:282px" %)((( 838 +Display or set the dynamic or static IP mode of Ethernet1 839 +)))|(% style="width:452px" %)((( 840 +HSX1870.0 = 0, Static IP mode 841 + 842 +HSX1870.0 = 1, dynamic IP mode 843 +))) 844 +|=(% style="width: 160px;" %)((( 845 +HSW1871 846 +)))|(% style="width:282px" %)((( 847 +Confirm the IP, subnet mask, gateway, DNS1, DNS2, and dynamic static IP settings for Ethernet1 848 +)))|(% style="width:452px" %)((( 849 +~= 1, confirm the setting (i.e., after modifying IP-related information, set this address to 1, representing confirmation of the modification, after which it will be reset to 0) 850 +))) 851 +|=(% style="width: 160px;" %)((( 852 +HSW1872 853 +)))|(% colspan="1" rowspan="8" style="width:282px" %)((( 854 +①Display and modify DNS1 and DNS2 of Ethernet1 855 + 856 +②Related registers can be read and written mode (only static IP mode can be written) 857 +)))|(% style="width:452px" %)((( 858 +Ethernet1 Local DNS1 address high byte 1 859 +))) 860 +|=(% style="width: 160px;" %)((( 861 +HSW1873 862 +)))|(% style="width:452px" %)Ethernet1 Local DNS1 address high byte 2 863 +|=(% style="width: 160px;" %)((( 864 +HSW1874 865 +)))|(% style="width:452px" %)Ethernet1 Local DNS1 address high byte 3 866 +|=(% style="width: 160px;" %)((( 867 +HSW1875 868 +)))|(% style="width:452px" %)Ethernet1 Local DNS1 address high byte 4 869 +|=(% style="width: 160px;" %)((( 870 +HSW1876 871 +)))|(% style="width:452px" %)Ethernet1 Local DNS2 address high byte 1 872 +|=(% style="width: 160px;" %)((( 873 +HSW1877 874 +)))|(% style="width:452px" %)Ethernet1 Local DNS2 address high byte 2 875 +|=(% style="width: 160px;" %)((( 876 +HSW1878 877 +)))|(% style="width:452px" %)Ethernet1 Local DNS2 address high byte 3 878 +|=(% style="width: 160px;" %)((( 879 +HSW1879 880 +)))|(% style="width:452px" %)Ethernet1 Local DNS2 address high byte 4 642 642 |=(% style="width: 160px;" %)HSW10000~~19999|(% style="width:282px" %)Power-down storage area|(% style="width:452px" %)After restart, the data remains 643 643 |=(% style="width: 160px;" %)HSW10035|(% rowspan="13" style="width:282px" %)((( 644 -**✎Note: **Only valid when the HMI is plugged into the Ethernet cable. 645 - 646 -1. If Ethernet settings is enabled in project parameters, this register displays the set value. 647 -1. If Ethernet settings is not enabled in project parameters, IP would automatically obtained IP. 648 -1. If HMI is not connected to the network, the register is displayed as 0 whether the engineering parameters are set. 649 -1. 4. All IP registers of HMI are read-only. 883 +Note: Valid when Ethernet1 of HMI is plugged into the network cable. 884 +①、When the Ethernet setting is enabled in the project parameters, this register displays the set value. 885 +②. When the Ethernet setting is not enabled in the engineering parameters, the register displays the Ethernet IP automatically acquired by the HMI. 886 +③. When the HMI is not plugged into the network cable, the register will show 0 whether the engineering parameters are set or not. 887 +④.IP related registers can be read and written (only static IP mode can be written). 650 650 )))|(% style="width:452px" %)Local IP address high byte 1 651 651 |=(% style="width: 160px;" %)HSW10036|(% style="width:452px" %)Local IP address high byte 2 652 652 |=(% style="width: 160px;" %)HSW10037|(% style="width:452px" %)Local IP address high byte 3 ... ... @@ -661,9 +661,11 @@ 661 661 |=(% style="width: 160px;" %)HSW10046|(% style="width:452px" %)Local gateway address high byte 4 662 662 |=(% style="width: 160px;" %)HSW10047|(% style="width:452px" %)Local port address 663 663 |=(% style="width: 160px;" %)HSW10048|(% rowspan="6" style="width:282px" %)((( 664 -Display sthe MAC code of thecurrent networkcard902 +①Display the MAC code of Ethernet1 NIC 665 665 666 -(Hexadecimal display) 904 +(hexadecimal display) 905 + 906 +②Read-only mode, not modifiable 667 667 )))|(% style="width:452px" %)Local MAC code high word 1 668 668 |=(% style="width: 160px;" %)HSW10049|(% style="width:452px" %)Local MAC code high word 2 669 669 |=(% style="width: 160px;" %)HSW10050|(% style="width:452px" %)Local MAC code high word 3 ... ... @@ -753,10 +753,10 @@ 753 753 |=(% style="width: 160px;" %)HSW11760|(% style="width:282px" %)Screensaver countdown|(% style="width:452px" %)Display the countdown to enter the Screensaver, unit: second. 754 754 |=(% style="width: 160px;" %)HSW11761|(% style="width:282px" %)Screensaver screen number|(% style="width:452px" %)Set the screen number for Screensaver 755 755 756 -== **Serial port communication configuration**==996 +== Serial port communication configuration == 757 757 758 758 (% class="table-bordered" %) 759 -|=(% style="width: 102px;" %)Port|=(% style="width: 173px;" %)**Function**|=(% style="width: 122px;" %)**Address**|=(% colspan="2" style="width: 506px;" %)**Description** 999 +|=(% scope="row" style="width: 102px;" %)Port|=(% style="width: 173px;" %)**Function**|=(% style="width: 122px;" %)**Address**|=(% colspan="2" style="width: 506px;" %)**Description** 760 760 |(% colspan="1" rowspan="11" style="width:102px" %)COM1|(% style="width:173px" %)Communication mode|(% style="width:122px" %)HSW10061|(% colspan="2" style="width:506px" %)((( 761 761 * =0: RS232 762 762 * =1: RS485 ... ... @@ -786,10 +786,22 @@ 786 786 * =1: ODD 787 787 * =2: EVEN 788 788 ))) 789 -|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10066|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000 790 -|(% style="width:173px" %)reveive timeout|(% style="width:122px" %)HSW10067|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000 791 -|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10068|(% colspan="2" style="width:506px" %)Unit: times. Range: 0~~100 792 -|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10069|(% colspan="2" style="width:506px" %)Unit: s. Range: 0~~300 1029 +|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10066|(% colspan="2" style="width:506px" %)((( 1030 +* Unit: ms. 1031 +* Range: 0 to 30000 1032 +))) 1033 +|(% style="width:173px" %)reveive timeout|(% style="width:122px" %)HSW10067|(% colspan="2" style="width:506px" %)((( 1034 +* Unit: ms. 1035 +* Range: 0 to 30000 1036 +))) 1037 +|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10068|(% colspan="2" style="width:506px" %)((( 1038 +* Unit: times. 1039 +* Range: 0 to 100 1040 +))) 1041 +|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10069|(% colspan="2" style="width:506px" %)((( 1042 +* Unit: s. 1043 +* Range: 0 to 300 1044 +))) 793 793 |(% style="width:173px" %)HMI station number|(% style="width:122px" %)HSW10070|(% colspan="2" style="width:506px" %) 794 794 |(% style="width:173px" %)PLC station number|(% style="width:122px" %)HSW10071|(% colspan="2" style="width:506px" %) 795 795 |(% colspan="1" rowspan="11" style="width:102px" %)COM1-2|(% style="width:173px" %)Communication mode|(% style="width:122px" %)HSW10094|(% colspan="2" style="width:506px" %)((( ... ... @@ -822,10 +822,22 @@ 822 822 * =1: ODD 823 823 * =2: EVEN 824 824 ))) 825 -|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10099|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000 826 -|(% style="width:173px" %)receive timeout|(% style="width:122px" %)HSW10100|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000 827 -|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10101|(% colspan="2" style="width:506px" %)Unit: times. Range: 0~~100 828 -|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10102|(% colspan="2" style="width:506px" %)Unit: s. Range: 0~~30 1077 +|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10099|(% colspan="2" style="width:506px" %)((( 1078 +* Unit: ms. 1079 +* Range: 0 to 30000 1080 +))) 1081 +|(% style="width:173px" %)receive timeout|(% style="width:122px" %)HSW10100|(% colspan="2" style="width:506px" %)((( 1082 +* Unit: ms. 1083 +* Range: 0 to 30000 1084 +))) 1085 +|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10101|(% colspan="2" style="width:506px" %)((( 1086 +* Unit: times. 1087 +* Range: 0 to 100 1088 +))) 1089 +|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10102|(% colspan="2" style="width:506px" %)((( 1090 +* Unit: s. 1091 +* Range: 0 to 30 1092 +))) 829 829 |(% style="width:173px" %)HMI station number|(% style="width:122px" %)HSW10103|(% colspan="2" style="width:506px" %) 830 830 |(% style="width:173px" %)PLC station number|(% style="width:122px" %)HSW10104|(% colspan="2" style="width:506px" %) 831 831 |(% colspan="1" rowspan="11" style="width:102px" %)COM1-3|(% style="width:173px" %)Communication mode|(% style="width:122px" %)HSW10120|(% colspan="2" style="width:506px" %)((( ... ... @@ -858,10 +858,22 @@ 858 858 * =1: ODD 859 859 * =2: EVEN 860 860 ))) 861 -|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10125|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000 862 -|(% style="width:173px" %)receive timeout|(% style="width:122px" %)HSW10126|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000 863 -|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10127|(% colspan="2" style="width:506px" %)Unit: times. Range: 0~~100 864 -|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10128|(% colspan="2" style="width:506px" %)Unit: s. Range: 0~~30 1125 +|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10125|(% colspan="2" style="width:506px" %)((( 1126 +* Unit: ms. 1127 +* Range: 0 to 30000 1128 +))) 1129 +|(% style="width:173px" %)receive timeout|(% style="width:122px" %)HSW10126|(% colspan="2" style="width:506px" %)((( 1130 +* Unit: ms. 1131 +* Range: 0 to 30000 1132 +))) 1133 +|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10127|(% colspan="2" style="width:506px" %)((( 1134 +* Unit: times. 1135 +* Range: 0 to 100 1136 +))) 1137 +|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10128|(% colspan="2" style="width:506px" %)((( 1138 +* Unit: s. 1139 +* Range: 0 to 30 1140 +))) 865 865 |(% style="width:173px" %)HMI station number|(% style="width:122px" %)HSW10129|(% colspan="2" style="width:506px" %) 866 866 |(% style="width:173px" %)PLC station number|(% style="width:122px" %)HSW10130|(% colspan="2" style="width:506px" %) 867 867 |(% colspan="1" rowspan="11" style="width:102px" %)COM2|(% style="width:173px" %)Communication mode|(% style="width:122px" %)HSW10072|(% colspan="2" style="width:506px" %)((( ... ... @@ -892,10 +892,22 @@ 892 892 * =1: ODD 893 893 * =2: EVEN 894 894 ))) 895 -|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10077|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000 896 -|(% style="width:173px" %)receive timeout|(% style="width:122px" %)HSW10078|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000 897 -|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10079|(% colspan="2" style="width:506px" %)Unit: times. Range: 0~~100 898 -|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10080|(% colspan="2" style="width:506px" %)Unit: s. Range: 0~~30 1171 +|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10077|(% colspan="2" style="width:506px" %)((( 1172 +* Unit: ms. 1173 +* Range: 0 to 30000 1174 +))) 1175 +|(% style="width:173px" %)receive timeout|(% style="width:122px" %)HSW10078|(% colspan="2" style="width:506px" %)((( 1176 +* Unit: ms. 1177 +* Range: 0 to 30000 1178 +))) 1179 +|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10079|(% colspan="2" style="width:506px" %)((( 1180 +* Unit: times. 1181 +* Range: 0 to 100 1182 +))) 1183 +|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10080|(% colspan="2" style="width:506px" %)((( 1184 +* Unit: s. 1185 +* Range: 0 to 30 1186 +))) 899 899 |(% style="width:173px" %)HMI station number|(% style="width:122px" %)HSW10081|(% colspan="2" style="width:506px" %) 900 900 |(% style="width:173px" %)PLC station number|(% style="width:122px" %)HSW10082|(% colspan="2" style="width:506px" %) 901 901 |(% colspan="1" rowspan="11" style="width:102px" %)COM2-2|(% style="width:173px" %)Communication mode|(% style="width:122px" %)HSW10105|(% colspan="2" style="width:506px" %)((( ... ... @@ -926,10 +926,22 @@ 926 926 * =1: ODD 927 927 * =2: EVEN 928 928 ))) 929 -|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10110|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000 930 -|(% style="width:173px" %)receive timeout|(% style="width:122px" %)HSW10111|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000 931 -|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10112|(% colspan="2" style="width:506px" %)Unit: times. Range: 0~~100 932 -|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10113|(% colspan="2" style="width:506px" %)Unit: s. Range: 0~~30 1217 +|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10110|(% colspan="2" style="width:506px" %)((( 1218 +* Unit: ms. 1219 +* Range: 0 to 30000 1220 +))) 1221 +|(% style="width:173px" %)receive timeout|(% style="width:122px" %)HSW10111|(% colspan="2" style="width:506px" %)((( 1222 +* Unit: ms. 1223 +* Range: 0 to 30000 1224 +))) 1225 +|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10112|(% colspan="2" style="width:506px" %)((( 1226 +* Unit: times. 1227 +* Range: 0 to 100 1228 +))) 1229 +|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10113|(% colspan="2" style="width:506px" %)((( 1230 +* Unit: s. 1231 +* Range: 0 to 30 1232 +))) 933 933 |(% style="width:173px" %)HMI station number|(% style="width:122px" %)HSW10114|(% colspan="2" style="width:506px" %) 934 934 |(% style="width:173px" %)PLC station number|(% style="width:122px" %)HSW10115|(% colspan="2" style="width:506px" %) 935 935 |(% colspan="1" rowspan="11" style="width:102px" %)COM3|(% style="width:173px" %)Communication mode|(% style="width:122px" %)HSW10083|(% colspan="2" style="width:506px" %)((( ... ... @@ -959,29 +959,48 @@ 959 959 * =1: ODD 960 960 * =2: EVEN 961 961 ))) 962 -|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10088|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000 963 -|(% style="width:173px" %)receive timeout|(% style="width:122px" %)HSW10089|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000 964 -|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10090|(% colspan="2" style="width:506px" %)Unit: times. Range: 0~~100 965 -|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10091|(% colspan="2" style="width:506px" %)Unit: s. Range: 0~~30 1262 +|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10088|(% colspan="2" style="width:506px" %)((( 1263 +* Unit: ms. 1264 +* Range: 0 to 30000 1265 +))) 1266 +|(% style="width:173px" %)receive timeout|(% style="width:122px" %)HSW10089|(% colspan="2" style="width:506px" %)((( 1267 +* Unit: ms. 1268 +* Range: 0 to 30000 1269 +))) 1270 +|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10090|(% colspan="2" style="width:506px" %)((( 1271 +* Unit: times. 1272 +* Range: 0 to 100 1273 +))) 1274 +|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10091|(% colspan="2" style="width:506px" %)((( 1275 +* Unit: s. 1276 +* Range: 0 to 30 1277 +))) 966 966 |(% style="width:173px" %)HMI station number|(% style="width:122px" %)HSW10092|(% colspan="2" style="width:506px" %) 967 967 |(% style="width:173px" %)PLC station number|(% style="width:122px" %)HSW10093|(% colspan="2" style="width:506px" %) 968 968 |(% colspan="1" rowspan="2" style="width:102px" %)CAN port|(% style="width:173px" %)CAN1 baud rate|(% style="width:122px" %)HSW010116|(% style="width:299px" %)((( 969 -Unit: K, the baud rate must be an integer, for example, when the baud rate required is 250000, just enter 250. 1281 +Unit: K, the baud rate must be an integer. 1282 + 1283 +For example, when the baud rate required is 250000, just enter 250. 970 970 )))|(% colspan="1" rowspan="2" style="width:218px" %)**✎Note: **If baud rate has been modified,please wait 5 seconds,then restart the HMI to take effect. 971 -|(% style="width:173px" %)CAN2 baud rate|(% style="width:122px" %)HSW010117|(% style="width:299px" %)Unit: K, the baud rate must be an integer, for example, when the baud rate required is 250000, just enter 250. 1285 +|(% style="width:173px" %)CAN2 baud rate|(% style="width:122px" %)HSW010117|(% style="width:299px" %)((( 1286 +Unit: K, the baud rate must be an integer. 972 972 973 -== **Ethernet communication configuration** == 1288 +For example, when the baud rate required is 250000, just enter 250. 1289 +))) 974 974 1291 +== Ethernet communication configuration == 1292 + 975 975 (% class="table-bordered" %) 976 -| =(% style="width:;" %)**No.**|=(% style="width:;" %)**Function**|=(% style="width:;" %)**Address**|=(% style="width:;" %)**Description**1294 +|(% style="width:40px" %)**No.**|(% style="width:295px" %)**Function**|(% style="width:220px" %)**Address**|(% style="width:336px" %)**Description** 977 977 |(% rowspan="7" style="width:40px" %)1|(% colspan="1" rowspan="7" style="width:295px" %)Ethernet parameter configuration for communication number 1 in list. Configure those addresses according to connected device. After configuration, wait for 5 seconds and restart the HMI.|(% style="width:220px" %)HSW11004|(% style="width:336px" %)Device IP address high word 1 978 978 |(% style="width:220px" %)HSW11005|(% style="width:336px" %)Device IP address high word 2 979 979 |(% style="width:220px" %)HSW11006|(% style="width:336px" %)Device IP address high word 3 980 980 |(% style="width:220px" %)HSW11007|(% style="width:336px" %)Device IP address high word 4 981 981 |(% style="width:220px" %)HSW11008|(% style="width:336px" %)Device Port number 982 -|(% style="width:220px" %)HSW11009|=(% style="width: 336px;" %)((( 983 -* =2 TCP 984 -* =3 UDP 1300 +|(% style="width:220px" %)HSW11009|(% style="width:336px" %)((( 1301 +~=2 TCP 1302 + 1303 +~=3 UDP 985 985 ))) 986 986 |(% style="width:220px" %)HSW11010|(% style="width:336px" %)Reserved 987 987 |(% rowspan="7" style="width:40px" %)2|(% colspan="1" rowspan="7" style="width:295px" %)Ethernet parameter configuration for communication number 2 in list. Configure those addresses according to connected device. After configuration, wait for 5 seconds and restart the HMI.|(% style="width:220px" %)HSW11011|(% style="width:336px" %)Device IP address high word 1 ... ... @@ -989,9 +989,10 @@ 989 989 |(% style="width:220px" %)HSW11013|(% style="width:336px" %)Device IP address high word 3 990 990 |(% style="width:220px" %)HSW11014|(% style="width:336px" %)Device IP address high word 4 991 991 |(% style="width:220px" %)HSW11015|(% style="width:336px" %)Device Port number 992 -|(% style="width:220px" %)HSW11016|=(% style="width: 336px;" %)((( 993 -* =2 TCP 994 -* =3 UDP 1311 +|(% style="width:220px" %)HSW11016|(% style="width:336px" %)((( 1312 +~=2 TCP 1313 + 1314 +~=3 UDP 995 995 ))) 996 996 |(% style="width:220px" %)HSW11017|(% style="width:336px" %)Reserved 997 997 |(% style="width:40px" %)…|(% style="width:295px" %) |(% style="width:220px" %)…|(% style="width:336px" %)… ... ... @@ -1000,7 +1000,11 @@ 1000 1000 |(% style="width:220px" %)HSW11223|(% style="width:336px" %)Device IP address high word 3 1001 1001 |(% style="width:220px" %)HSW11224|(% style="width:336px" %)Device IP address high word 4 1002 1002 |(% style="width:220px" %)HSW11225|(% style="width:336px" %)Device Port number 1003 -|(% style="width:220px" %)HSW11226|=(% style="width: 336px;" %)2 TCP; =3 UDP 1323 +|(% style="width:220px" %)HSW11226|(% style="width:336px" %)((( 1324 +~=2 TCP; 1325 + 1326 +~=3 UDP 1327 +))) 1004 1004 |(% style="width:220px" %)HSW11227|(% style="width:336px" %)Reserved 1005 1005 1006 1006 (% class="box infomessage" %) ... ... @@ -1008,7 +1008,7 @@ 1008 1008 **✎Note:** The number of Ethernet connections supported by different HMI series varies. 1009 1009 ))) 1010 1010 1011 -== **Communication control**==1335 +== Communication control == 1012 1012 1013 1013 (% class="table-bordered" %) 1014 1014 |=(% style="width: 135px;" %)**Communication No.**|=(% style="width: 102px;" %)**Station No.**|=(% style="width: 185px;" %)**Control bit**|=(% style="width: 191px;" %)**Communication lamp**|=(% style="width: 271px;" %)**Description**