Changes for page 13 HMI Internal Registers

Last modified by Jett on 2025/04/28 16:07

From version 4.2
edited by Stone Wu
on 2022/08/06 14:08
Change comment: There is no comment for this version
To version 12.1
edited by Bob
on 2023/01/07 14:26
Change comment: There is no comment for this version

Summary

Details

Page properties
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.Stone
1 +XWiki.Bob
Content
... ... @@ -4,11 +4,11 @@
4 4  
5 5  *HSW, HDW, HUW, HAW are word address, HSX, HDX, HUX, HAX are bit address.
6 6  
7 -1. **System data area (HSW): **A special register defined by the system.
8 -1. **Data storage area (HDW/HDX): **Users store user data.
9 -1. **System data area (HUW): **A special register defined by the system.
10 -1. **System Data (HAW)**: System register used for power-off save.
11 -1. **Recipe index area (RPW): **System register used for recipe index.
7 +* **System data area (HSW): **A special register defined by the system.
8 +* **Data storage area (HDW/HDX): **Users store user data.
9 +* **System data area (HUW): **A special register defined by the system.
10 +* **System Data (HAW)**: System register used for power-off save.
11 +* **Recipe index area (RPW): **System register used for recipe index.
12 12  
13 13  HMI internal registers are divided into bit address and word address, which can be accessed in two ways (take HDW as an example).
14 14  
... ... @@ -342,7 +342,7 @@
342 342  |=(% style="width: 160px;" %)HSW884|(% style="width:282px" %)Enter the system network configuration interface|(% style="width:452px" %)(((
343 343  * =0: Do not enter the network configuration interface
344 344  * =1: Enter the system network configuration interface.
345 -** (ig series HMI only supports to enter the system interface)
345 +** ig series HMI only supports to enter the system interface
346 346  
347 347  )))
348 348  |=(% style="width: 160px;" %)HSW885|(% style="width:282px" %)When the control object hides the address is read failed (communication failure), set the display mode of the object|(% style="width:452px" %)(((
... ... @@ -512,6 +512,10 @@
512 512  * HSX1502.0=1: Modification comfirmed. Save the data of HSW1450~~HSW1501 to a file for immediate effect.
513 513  * HSX1502.1=1:Modification cancelled. Restore the current data of hSW1450-HSW1501 to the data saved in the file last time.
514 514  )))
515 +|=(% style="width: 160px;" %)HSW1509|(% style="width:282px" %)Curve width|(% style="width:452px" %)(((
516 +* =0: Use the curve width set by project default.
517 +* =1 to 10: use special register to set curve width.
518 +)))
515 515  |=(% style="width: 160px;" %)HSW1603|(% style="width:282px" %)Number of current unreleased alarms|(% style="width:452px" %)The number of current unreleased alarms in alarm record file.
516 516  |=(% style="width: 160px;" %)HSW1604|(% style="width:282px" %)The auxiliary judgment address when the control bit in the Object Lock fails to be read|(% style="width:452px" %)(((
517 517  * =0: The auxiliary address is invalid.
... ... @@ -614,6 +614,174 @@
614 614  * =1: Server connection is OK
615 615  )))
616 616  |=(% style="width: 160px;" %)HSW1761|(% style="width:282px" %)Display 4G network signal strength|(% style="width:452px" %)Signal strength: 0~~31. The greater the value ,the signal is stronger
621 +|=(% style="width: 160px;" %)(((
622 +HSW1762
623 +)))|(% colspan="1" rowspan="13" style="width:282px" %)(((
624 +Note: Valid when Ethernet2 of HMI is plugged into the network cable.
625 +①、When the Ethernet setting is enabled in the project parameters, this register displays the set value.
626 +②. When the Ethernet setting is not enabled in the engineering parameters, the register displays the Ethernet IP automatically acquired by the HMI.
627 +③. When the HMI is not plugged into the network cable, the register will show 0 whether the engineering parameters are set or not.
628 +④.IP related registers can be read and written (only static IP mode can be written).
629 +)))|(% style="width:452px" %)(((
630 +Ethernet2 Local IP address high byte 1
631 +)))
632 +|=(% style="width: 160px;" %)(((
633 +HSW1763
634 +)))|(% style="width:452px" %)(((
635 +Ethernet2 Local IP address high byte 2
636 +)))
637 +|=(% style="width: 160px;" %)(((
638 +HSW1764
639 +)))|(% style="width:452px" %)(((
640 +Ethernet2 Local IP address high byte 3
641 +)))
642 +|=(% style="width: 160px;" %)(((
643 +HSW1765
644 +)))|(% style="width:452px" %)(((
645 +Ethernet2 Local IP address high byte 4
646 +)))
647 +|=(% style="width: 160px;" %)(((
648 +HSW1766
649 +)))|(% style="width:452px" %)(((
650 +Ethernet2 Local mask IP address high byte 1
651 +)))
652 +|=(% style="width: 160px;" %)(((
653 +HSW1767
654 +)))|(% style="width:452px" %)(((
655 +Ethernet2 Local mask IP address high byte 2
656 +)))
657 +|=(% style="width: 160px;" %)(((
658 +HSW1768
659 +)))|(% style="width:452px" %)Ethernet2 Local mask IP address high byte 3
660 +|=(% style="width: 160px;" %)HSW1769|(% style="width:452px" %)Ethernet2 Local mask IP address high byte 4
661 +|=(% style="width: 160px;" %)(((
662 +HSW1770
663 +)))|(% style="width:452px" %)(((
664 +Ethernet2 Local gateway IP address high byte 1
665 +)))
666 +|=(% style="width: 160px;" %)(((
667 +HSW1771
668 +)))|(% style="width:452px" %)(((
669 +Ethernet2 Local gateway IP address high byte 2
670 +)))
671 +|=(% style="width: 160px;" %)(((
672 +HSW1772
673 +)))|(% style="width:452px" %)(((
674 +Ethernet2 Local gateway IP address high byte 3
675 +)))
676 +|=(% style="width: 160px;" %)(((
677 +HSW1773
678 +)))|(% style="width:452px" %)(((
679 +Ethernet2 Local gateway IP address high byte 4
680 +)))
681 +|=(% style="width: 160px;" %)(((
682 +HSW1774
683 +)))|(% style="width:452px" %)(((
684 +Ethernet2 Local Port Address
685 +)))
686 +|=(% style="width: 160px;" %)(((
687 +HSW1775
688 +)))|(% colspan="1" rowspan="6" style="width:282px" %)(((
689 +①Display the MAC code of Ethernet2 NIC
690 +
691 +(hexadecimal display)
692 +
693 +②Read-only mode, not modifiable
694 +)))|(% style="width:452px" %)(((
695 +Ethernet2 Local MAC code high byte 1
696 +)))
697 +|=(% style="width: 160px;" %)(((
698 +HSW1776
699 +)))|(% style="width:452px" %)(((
700 +Ethernet2 Local MAC code high byte 2
701 +)))
702 +|=(% style="width: 160px;" %)(((
703 +HSW1777
704 +)))|(% style="width:452px" %)(((
705 +Ethernet2 Local MAC code high byte 3
706 +)))
707 +|=(% style="width: 160px;" %)(((
708 +HSW1778
709 +)))|(% style="width:452px" %)(((
710 +Ethernet2 Local MAC code high byte 4
711 +)))
712 +|=(% style="width: 160px;" %)(((
713 +HSW1779
714 +)))|(% style="width:452px" %)(((
715 +Ethernet2 Local MAC code high byte 5
716 +)))
717 +|=(% style="width: 160px;" %)(((
718 +HSW1780
719 +)))|(% style="width:452px" %)(((
720 +Ethernet2 Local MAC code high byte 6
721 +)))
722 +|=(% style="width: 160px;" %)(((
723 +HSW1781
724 +)))|(% colspan="1" rowspan="8" style="width:282px" %)(((
725 +①Display and modify DNS1 and DNS2 of Ethernet2
726 +
727 +②Related registers can be read and written mode (only static IP mode can be written)
728 +)))|(% style="width:452px" %)(((
729 +Ethernet2 Local DNS1 address high byte 1
730 +)))
731 +|=(% style="width: 160px;" %)(((
732 +HSW1782
733 +)))|(% style="width:452px" %)(((
734 +Ethernet2 Local DNS1 address high byte 2
735 +)))
736 +|=(% style="width: 160px;" %)(((
737 +HSW1783
738 +)))|(% style="width:452px" %)(((
739 +Ethernet2 Local DNS1 address high byte 3
740 +)))
741 +|=(% style="width: 160px;" %)(((
742 +HSW1784
743 +)))|(% style="width:452px" %)(((
744 +Ethernet2 Local DNS1 address high byte 4
745 +)))
746 +|=(% style="width: 160px;" %)(((
747 +HSW1785
748 +)))|(% style="width:452px" %)(((
749 +Ethernet2 Local DNS2 address high byte 1
750 +)))
751 +|=(% style="width: 160px;" %)(((
752 +HSW1786
753 +)))|(% style="width:452px" %)(((
754 +Ethernet2 Local DNS2 address high byte 2
755 +)))
756 +|=(% style="width: 160px;" %)(((
757 +HSW1787
758 +)))|(% style="width:452px" %)(((
759 +Ethernet2 Local DNS2 address high byte 3
760 +)))
761 +|=(% style="width: 160px;" %)(((
762 +HSW1788
763 +)))|(% style="width:452px" %)(((
764 +Ethernet2 Local DNS2 address high byte 4
765 +)))
766 +|=(% style="width: 160px;" %)(((
767 +HSW1789
768 +)))|(% colspan="1" style="width:282px" %)(((
769 +Display or set the dynamic or static IP mode of Ethernet2
770 +)))|(% style="width:452px" %)(((
771 +HSX1789.0 = 0, Static IP mode
772 +
773 +HSX1789.0 = 1, dynamic IP mode
774 +)))
775 +|=(% style="width: 160px;" %)(((
776 +HSW1790
777 +)))|(% colspan="1" style="width:282px" %)(((
778 +Confirm Ethernet2 IP, subnet mask, gateway, DNS1, DNS2, and dynamic static IP settings
779 +)))|(% style="width:452px" %)(((
780 +~= 1, confirm the setting (i.e., after modifying IP-related information, set this address to 1, representing confirmation of the modification, after which it will be reset to 0)
781 +)))
782 +|=(% style="width: 160px;" %)(((
783 +HSW1791
784 +)))|(% colspan="1" style="width:282px" %)(((
785 +Network status of the Ethernet2 connection server
786 +)))|(% style="width:452px" %)(((
787 +~= 0, connection to the server is abnormal = 1, connection to the server is normal
788 +)))
617 617  |=(% style="width: 160px;" %)HSW1852|(% style="width:282px" %)Control the interval in two consecutive clicks|(% style="width:452px" %)Limit range: 1~~500ms. The default is 100 ms.
618 618  |=(% style="width: 160px;" %)HSW1853|(% style="width:282px" %)File format for exporting data records to USB flash drive or SD card|(% style="width:452px" %)(((
619 619  * =0: db database
... ... @@ -639,14 +639,80 @@
639 639  * =1: download firmware
640 640  * =2: enter the background
641 641  )))
814 +|=(% style="width: 160px;" %)HSW1865|(% style="width:282px" %)Priority connection to the cloud|(% style="width:452px" %)(((
815 +* =0: priority Ethernet
816 +* =1: priority WLAN
817 +* =2: priority 4G
818 +)))
819 +|=(% style="width: 160px;" %)HSW1866|(% style="width:282px" %)Delete the LUa extension module file|(% style="width:452px" %)(((
820 +* =0: delete;
821 +* = Others: do not delete
822 +)))
823 +|=(% style="width: 160px;" %)HSW1867|(% style="width:282px" %)Reset mode|(% style="width:452px" %)(((
824 +Monitor address is set during reset of reset switch, whether to cancel reset,
825 +
826 +* = 0: yes (default);
827 +* = 1: no
828 +)))
829 +|=(% style="width: 160px;" %)HSW1868|(% style="width:282px" %)Double-click or long press the record type table mode|(% style="width:452px" %)(((
830 +Controls whether the button pops up when double-clicking or long pressing on record type table object
831 +
832 +* = 0: yes (default);
833 +* = 1: no
834 +)))
835 +|=(% style="width: 160px;" %)(((
836 +HSW1870
837 +)))|(% style="width:282px" %)(((
838 +Display or set the dynamic or static IP mode of Ethernet1
839 +)))|(% style="width:452px" %)(((
840 +HSX1870.0 = 0, Static IP mode
841 +
842 +HSX1870.0 = 1, dynamic IP mode
843 +)))
844 +|=(% style="width: 160px;" %)(((
845 +HSW1871
846 +)))|(% style="width:282px" %)(((
847 +Confirm the IP, subnet mask, gateway, DNS1, DNS2, and dynamic static IP settings for Ethernet1
848 +)))|(% style="width:452px" %)(((
849 +~= 1, confirm the setting (i.e., after modifying IP-related information, set this address to 1, representing confirmation of the modification, after which it will be reset to 0)
850 +)))
851 +|=(% style="width: 160px;" %)(((
852 +HSW1872
853 +)))|(% colspan="1" rowspan="8" style="width:282px" %)(((
854 +①Display and modify DNS1 and DNS2 of Ethernet1
855 +
856 +②Related registers can be read and written mode (only static IP mode can be written)
857 +)))|(% style="width:452px" %)(((
858 +Ethernet1 Local DNS1 address high byte 1
859 +)))
860 +|=(% style="width: 160px;" %)(((
861 +HSW1873
862 +)))|(% style="width:452px" %)Ethernet1 Local DNS1 address high byte 2
863 +|=(% style="width: 160px;" %)(((
864 +HSW1874
865 +)))|(% style="width:452px" %)Ethernet1 Local DNS1 address high byte 3
866 +|=(% style="width: 160px;" %)(((
867 +HSW1875
868 +)))|(% style="width:452px" %)Ethernet1 Local DNS1 address high byte 4
869 +|=(% style="width: 160px;" %)(((
870 +HSW1876
871 +)))|(% style="width:452px" %)Ethernet1 Local DNS2 address high byte 1
872 +|=(% style="width: 160px;" %)(((
873 +HSW1877
874 +)))|(% style="width:452px" %)Ethernet1 Local DNS2 address high byte 2
875 +|=(% style="width: 160px;" %)(((
876 +HSW1878
877 +)))|(% style="width:452px" %)Ethernet1 Local DNS2 address high byte 3
878 +|=(% style="width: 160px;" %)(((
879 +HSW1879
880 +)))|(% style="width:452px" %)Ethernet1 Local DNS2 address high byte 4
642 642  |=(% style="width: 160px;" %)HSW10000~~19999|(% style="width:282px" %)Power-down storage area|(% style="width:452px" %)After restart, the data remains
643 643  |=(% style="width: 160px;" %)HSW10035|(% rowspan="13" style="width:282px" %)(((
644 -**✎Note: **Only valid when the HMI is plugged into the Ethernet cable.
645 -
646 -1. If Ethernet settings is enabled in project parameters, this register displays the set value.
647 -1. If Ethernet settings is not enabled in project parameters, IP would automatically obtained IP.
648 -1. If HMI is not connected to the network, the register is displayed as 0 whether the engineering parameters are set.
649 -1. 4. All IP registers of HMI are read-only.
883 +Note: Valid when Ethernet1 of HMI is plugged into the network cable.
884 +①、When the Ethernet setting is enabled in the project parameters, this register displays the set value.
885 +②. When the Ethernet setting is not enabled in the engineering parameters, the register displays the Ethernet IP automatically acquired by the HMI.
886 +③. When the HMI is not plugged into the network cable, the register will show 0 whether the engineering parameters are set or not.
887 +④.IP related registers can be read and written (only static IP mode can be written).
650 650  )))|(% style="width:452px" %)Local IP address high byte 1
651 651  |=(% style="width: 160px;" %)HSW10036|(% style="width:452px" %)Local IP address high byte 2
652 652  |=(% style="width: 160px;" %)HSW10037|(% style="width:452px" %)Local IP address high byte 3
... ... @@ -661,9 +661,11 @@
661 661  |=(% style="width: 160px;" %)HSW10046|(% style="width:452px" %)Local gateway address high byte 4
662 662  |=(% style="width: 160px;" %)HSW10047|(% style="width:452px" %)Local port address
663 663  |=(% style="width: 160px;" %)HSW10048|(% rowspan="6" style="width:282px" %)(((
664 -Displays the MAC code of the current network card
902 +Display the MAC code of Ethernet1 NIC
665 665  
666 -(Hexadecimal display)
904 +(hexadecimal display)
905 +
906 +②Read-only mode, not modifiable
667 667  )))|(% style="width:452px" %)Local MAC code high word 1
668 668  |=(% style="width: 160px;" %)HSW10049|(% style="width:452px" %)Local MAC code high word 2
669 669  |=(% style="width: 160px;" %)HSW10050|(% style="width:452px" %)Local MAC code high word 3
... ... @@ -753,10 +753,10 @@
753 753  |=(% style="width: 160px;" %)HSW11760|(% style="width:282px" %)Screensaver countdown|(% style="width:452px" %)Display the countdown to enter the Screensaver, unit: second.
754 754  |=(% style="width: 160px;" %)HSW11761|(% style="width:282px" %)Screensaver screen number|(% style="width:452px" %)Set the screen number for Screensaver
755 755  
756 -== **Serial port communication configuration** ==
996 +== Serial port communication configuration ==
757 757  
758 758  (% class="table-bordered" %)
759 -|=(% style="width: 102px;" %)Port|=(% style="width: 173px;" %)**Function**|=(% style="width: 122px;" %)**Address**|=(% colspan="2" style="width: 506px;" %)**Description**
999 +|=(% scope="row" style="width: 102px;" %)Port|=(% style="width: 173px;" %)**Function**|=(% style="width: 122px;" %)**Address**|=(% colspan="2" style="width: 506px;" %)**Description**
760 760  |(% colspan="1" rowspan="11" style="width:102px" %)COM1|(% style="width:173px" %)Communication mode|(% style="width:122px" %)HSW10061|(% colspan="2" style="width:506px" %)(((
761 761  * =0: RS232
762 762  * =1: RS485
... ... @@ -786,10 +786,22 @@
786 786  * =1: ODD
787 787  * =2: EVEN
788 788  )))
789 -|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10066|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000
790 -|(% style="width:173px" %)reveive timeout|(% style="width:122px" %)HSW10067|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000
791 -|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10068|(% colspan="2" style="width:506px" %)Unit: times. Range: 0~~100
792 -|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10069|(% colspan="2" style="width:506px" %)Unit: s. Range: 0~~300
1029 +|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10066|(% colspan="2" style="width:506px" %)(((
1030 +* Unit: ms.
1031 +* Range: 0 to 30000
1032 +)))
1033 +|(% style="width:173px" %)reveive timeout|(% style="width:122px" %)HSW10067|(% colspan="2" style="width:506px" %)(((
1034 +* Unit: ms.
1035 +* Range: 0 to 30000
1036 +)))
1037 +|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10068|(% colspan="2" style="width:506px" %)(((
1038 +* Unit: times.
1039 +* Range: 0 to 100
1040 +)))
1041 +|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10069|(% colspan="2" style="width:506px" %)(((
1042 +* Unit: s.
1043 +* Range: 0 to 300
1044 +)))
793 793  |(% style="width:173px" %)HMI station number|(% style="width:122px" %)HSW10070|(% colspan="2" style="width:506px" %)
794 794  |(% style="width:173px" %)PLC station number|(% style="width:122px" %)HSW10071|(% colspan="2" style="width:506px" %)
795 795  |(% colspan="1" rowspan="11" style="width:102px" %)COM1-2|(% style="width:173px" %)Communication mode|(% style="width:122px" %)HSW10094|(% colspan="2" style="width:506px" %)(((
... ... @@ -822,10 +822,22 @@
822 822  * =1: ODD
823 823  * =2: EVEN
824 824  )))
825 -|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10099|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000
826 -|(% style="width:173px" %)receive timeout|(% style="width:122px" %)HSW10100|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000
827 -|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10101|(% colspan="2" style="width:506px" %)Unit: times. Range: 0~~100
828 -|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10102|(% colspan="2" style="width:506px" %)Unit: s. Range: 0~~30
1077 +|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10099|(% colspan="2" style="width:506px" %)(((
1078 +* Unit: ms.
1079 +* Range: 0 to 30000
1080 +)))
1081 +|(% style="width:173px" %)receive timeout|(% style="width:122px" %)HSW10100|(% colspan="2" style="width:506px" %)(((
1082 +* Unit: ms.
1083 +* Range: 0 to 30000
1084 +)))
1085 +|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10101|(% colspan="2" style="width:506px" %)(((
1086 +* Unit: times.
1087 +* Range: 0 to 100
1088 +)))
1089 +|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10102|(% colspan="2" style="width:506px" %)(((
1090 +* Unit: s.
1091 +* Range: 0 to 30
1092 +)))
829 829  |(% style="width:173px" %)HMI station number|(% style="width:122px" %)HSW10103|(% colspan="2" style="width:506px" %)
830 830  |(% style="width:173px" %)PLC station number|(% style="width:122px" %)HSW10104|(% colspan="2" style="width:506px" %)
831 831  |(% colspan="1" rowspan="11" style="width:102px" %)COM1-3|(% style="width:173px" %)Communication mode|(% style="width:122px" %)HSW10120|(% colspan="2" style="width:506px" %)(((
... ... @@ -858,10 +858,22 @@
858 858  * =1: ODD
859 859  * =2: EVEN
860 860  )))
861 -|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10125|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000
862 -|(% style="width:173px" %)receive timeout|(% style="width:122px" %)HSW10126|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000
863 -|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10127|(% colspan="2" style="width:506px" %)Unit: times. Range: 0~~100
864 -|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10128|(% colspan="2" style="width:506px" %)Unit: s. Range: 0~~30
1125 +|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10125|(% colspan="2" style="width:506px" %)(((
1126 +* Unit: ms.
1127 +* Range: 0 to 30000
1128 +)))
1129 +|(% style="width:173px" %)receive timeout|(% style="width:122px" %)HSW10126|(% colspan="2" style="width:506px" %)(((
1130 +* Unit: ms.
1131 +* Range: 0 to 30000
1132 +)))
1133 +|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10127|(% colspan="2" style="width:506px" %)(((
1134 +* Unit: times.
1135 +* Range: 0 to 100
1136 +)))
1137 +|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10128|(% colspan="2" style="width:506px" %)(((
1138 +* Unit: s.
1139 +* Range: 0 to 30
1140 +)))
865 865  |(% style="width:173px" %)HMI station number|(% style="width:122px" %)HSW10129|(% colspan="2" style="width:506px" %)
866 866  |(% style="width:173px" %)PLC station number|(% style="width:122px" %)HSW10130|(% colspan="2" style="width:506px" %)
867 867  |(% colspan="1" rowspan="11" style="width:102px" %)COM2|(% style="width:173px" %)Communication mode|(% style="width:122px" %)HSW10072|(% colspan="2" style="width:506px" %)(((
... ... @@ -892,10 +892,22 @@
892 892  * =1: ODD
893 893  * =2: EVEN
894 894  )))
895 -|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10077|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000
896 -|(% style="width:173px" %)receive timeout|(% style="width:122px" %)HSW10078|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000
897 -|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10079|(% colspan="2" style="width:506px" %)Unit: times. Range: 0~~100
898 -|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10080|(% colspan="2" style="width:506px" %)Unit: s. Range: 0~~30
1171 +|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10077|(% colspan="2" style="width:506px" %)(((
1172 +* Unit: ms.
1173 +* Range: 0 to 30000
1174 +)))
1175 +|(% style="width:173px" %)receive timeout|(% style="width:122px" %)HSW10078|(% colspan="2" style="width:506px" %)(((
1176 +* Unit: ms.
1177 +* Range: 0 to 30000
1178 +)))
1179 +|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10079|(% colspan="2" style="width:506px" %)(((
1180 +* Unit: times.
1181 +* Range: 0 to 100
1182 +)))
1183 +|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10080|(% colspan="2" style="width:506px" %)(((
1184 +* Unit: s.
1185 +* Range: 0 to 30
1186 +)))
899 899  |(% style="width:173px" %)HMI station number|(% style="width:122px" %)HSW10081|(% colspan="2" style="width:506px" %)
900 900  |(% style="width:173px" %)PLC station number|(% style="width:122px" %)HSW10082|(% colspan="2" style="width:506px" %)
901 901  |(% colspan="1" rowspan="11" style="width:102px" %)COM2-2|(% style="width:173px" %)Communication mode|(% style="width:122px" %)HSW10105|(% colspan="2" style="width:506px" %)(((
... ... @@ -926,10 +926,22 @@
926 926  * =1: ODD
927 927  * =2: EVEN
928 928  )))
929 -|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10110|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000
930 -|(% style="width:173px" %)receive timeout|(% style="width:122px" %)HSW10111|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000
931 -|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10112|(% colspan="2" style="width:506px" %)Unit: times. Range: 0~~100
932 -|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10113|(% colspan="2" style="width:506px" %)Unit: s. Range: 0~~30
1217 +|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10110|(% colspan="2" style="width:506px" %)(((
1218 +* Unit: ms.
1219 +* Range: 0 to 30000
1220 +)))
1221 +|(% style="width:173px" %)receive timeout|(% style="width:122px" %)HSW10111|(% colspan="2" style="width:506px" %)(((
1222 +* Unit: ms.
1223 +* Range: 0 to 30000
1224 +)))
1225 +|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10112|(% colspan="2" style="width:506px" %)(((
1226 +* Unit: times.
1227 +* Range: 0 to 100
1228 +)))
1229 +|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10113|(% colspan="2" style="width:506px" %)(((
1230 +* Unit: s.
1231 +* Range: 0 to 30
1232 +)))
933 933  |(% style="width:173px" %)HMI station number|(% style="width:122px" %)HSW10114|(% colspan="2" style="width:506px" %)
934 934  |(% style="width:173px" %)PLC station number|(% style="width:122px" %)HSW10115|(% colspan="2" style="width:506px" %)
935 935  |(% colspan="1" rowspan="11" style="width:102px" %)COM3|(% style="width:173px" %)Communication mode|(% style="width:122px" %)HSW10083|(% colspan="2" style="width:506px" %)(((
... ... @@ -959,29 +959,48 @@
959 959  * =1: ODD
960 960  * =2: EVEN
961 961  )))
962 -|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10088|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000
963 -|(% style="width:173px" %)receive timeout|(% style="width:122px" %)HSW10089|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000
964 -|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10090|(% colspan="2" style="width:506px" %)Unit: times. Range: 0~~100
965 -|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10091|(% colspan="2" style="width:506px" %)Unit: s. Range: 0~~30
1262 +|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10088|(% colspan="2" style="width:506px" %)(((
1263 +* Unit: ms.
1264 +* Range: 0 to 30000
1265 +)))
1266 +|(% style="width:173px" %)receive timeout|(% style="width:122px" %)HSW10089|(% colspan="2" style="width:506px" %)(((
1267 +* Unit: ms.
1268 +* Range: 0 to 30000
1269 +)))
1270 +|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10090|(% colspan="2" style="width:506px" %)(((
1271 +* Unit: times.
1272 +* Range: 0 to 100
1273 +)))
1274 +|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10091|(% colspan="2" style="width:506px" %)(((
1275 +* Unit: s.
1276 +* Range: 0 to 30
1277 +)))
966 966  |(% style="width:173px" %)HMI station number|(% style="width:122px" %)HSW10092|(% colspan="2" style="width:506px" %)
967 967  |(% style="width:173px" %)PLC station number|(% style="width:122px" %)HSW10093|(% colspan="2" style="width:506px" %)
968 968  |(% colspan="1" rowspan="2" style="width:102px" %)CAN port|(% style="width:173px" %)CAN1 baud rate|(% style="width:122px" %)HSW010116|(% style="width:299px" %)(((
969 -Unit: K, the baud rate must be an integer, for example, when the baud rate required is 250000, just enter 250.
1281 +Unit: K, the baud rate must be an integer.
1282 +
1283 +For example, when the baud rate required is 250000, just enter 250.
970 970  )))|(% colspan="1" rowspan="2" style="width:218px" %)**✎Note: **If baud rate has been modified,please wait 5 seconds,then restart the HMI to take effect.
971 -|(% style="width:173px" %)CAN2 baud rate|(% style="width:122px" %)HSW010117|(% style="width:299px" %)Unit: K, the baud rate must be an integer, for example, when the baud rate required is 250000, just enter 250.
1285 +|(% style="width:173px" %)CAN2 baud rate|(% style="width:122px" %)HSW010117|(% style="width:299px" %)(((
1286 +Unit: K, the baud rate must be an integer.
972 972  
973 -== **Ethernet communication configuration** ==
1288 +For example, when the baud rate required is 250000, just enter 250.
1289 +)))
974 974  
1291 +== Ethernet communication configuration ==
1292 +
975 975  (% class="table-bordered" %)
976 -|=(% style="width: 40px;" %)**No.**|=(% style="width: 295px;" %)**Function**|=(% style="width: 220px;" %)**Address**|=(% style="width: 336px;" %)**Description**
1294 +|(% style="width:40px" %)**No.**|(% style="width:295px" %)**Function**|(% style="width:220px" %)**Address**|(% style="width:336px" %)**Description**
977 977  |(% rowspan="7" style="width:40px" %)1|(% colspan="1" rowspan="7" style="width:295px" %)Ethernet parameter configuration for communication number 1 in list. Configure those addresses according to connected device. After configuration, wait for 5 seconds and restart the HMI.|(% style="width:220px" %)HSW11004|(% style="width:336px" %)Device IP address high word 1
978 978  |(% style="width:220px" %)HSW11005|(% style="width:336px" %)Device IP address high word 2
979 979  |(% style="width:220px" %)HSW11006|(% style="width:336px" %)Device IP address high word 3
980 980  |(% style="width:220px" %)HSW11007|(% style="width:336px" %)Device IP address high word 4
981 981  |(% style="width:220px" %)HSW11008|(% style="width:336px" %)Device Port number
982 -|(% style="width:220px" %)HSW11009|=(% style="width: 336px;" %)(((
983 -* =2 TCP
984 -* =3 UDP
1300 +|(% style="width:220px" %)HSW11009|(% style="width:336px" %)(((
1301 +~=2 TCP
1302 +
1303 +~=3 UDP
985 985  )))
986 986  |(% style="width:220px" %)HSW11010|(% style="width:336px" %)Reserved
987 987  |(% rowspan="7" style="width:40px" %)2|(% colspan="1" rowspan="7" style="width:295px" %)Ethernet parameter configuration for communication number 2 in list. Configure those addresses according to connected device. After configuration, wait for 5 seconds and restart the HMI.|(% style="width:220px" %)HSW11011|(% style="width:336px" %)Device IP address high word 1
... ... @@ -989,9 +989,10 @@
989 989  |(% style="width:220px" %)HSW11013|(% style="width:336px" %)Device IP address high word 3
990 990  |(% style="width:220px" %)HSW11014|(% style="width:336px" %)Device IP address high word 4
991 991  |(% style="width:220px" %)HSW11015|(% style="width:336px" %)Device Port number
992 -|(% style="width:220px" %)HSW11016|=(% style="width: 336px;" %)(((
993 -* =2 TCP
994 -* =3 UDP
1311 +|(% style="width:220px" %)HSW11016|(% style="width:336px" %)(((
1312 +~=2 TCP
1313 +
1314 +~=3 UDP
995 995  )))
996 996  |(% style="width:220px" %)HSW11017|(% style="width:336px" %)Reserved
997 997  |(% style="width:40px" %)…|(% style="width:295px" %) |(% style="width:220px" %)…|(% style="width:336px" %)…
... ... @@ -1000,7 +1000,11 @@
1000 1000  |(% style="width:220px" %)HSW11223|(% style="width:336px" %)Device IP address high word 3
1001 1001  |(% style="width:220px" %)HSW11224|(% style="width:336px" %)Device IP address high word 4
1002 1002  |(% style="width:220px" %)HSW11225|(% style="width:336px" %)Device Port number
1003 -|(% style="width:220px" %)HSW11226|=(% style="width: 336px;" %)2 TCP; =3 UDP
1323 +|(% style="width:220px" %)HSW11226|(% style="width:336px" %)(((
1324 +~=2 TCP;
1325 +
1326 +~=3 UDP
1327 +)))
1004 1004  |(% style="width:220px" %)HSW11227|(% style="width:336px" %)Reserved
1005 1005  
1006 1006  (% class="box infomessage" %)
... ... @@ -1008,7 +1008,7 @@
1008 1008  **✎Note:** The number of Ethernet connections supported by different HMI series varies.
1009 1009  )))
1010 1010  
1011 -== **Communication control** ==
1335 +== Communication control ==
1012 1012  
1013 1013  (% class="table-bordered" %)
1014 1014  |=(% style="width: 135px;" %)**Communication No.**|=(% style="width: 102px;" %)**Station No.**|=(% style="width: 185px;" %)**Control bit**|=(% style="width: 191px;" %)**Communication lamp**|=(% style="width: 271px;" %)**Description**