Changes for page 13 HMI Internal Registers

Last modified by Jett on 2025/04/28 16:07

From version 4.2
edited by Stone Wu
on 2022/08/06 14:08
Change comment: There is no comment for this version
To version 16.1
edited by Hunter
on 2023/01/14 11:08
Change comment: There is no comment for this version

Summary

Details

Page properties
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.Stone
1 +XWiki.Hunter
Content
... ... @@ -4,11 +4,11 @@
4 4  
5 5  *HSW, HDW, HUW, HAW are word address, HSX, HDX, HUX, HAX are bit address.
6 6  
7 -1. **System data area (HSW): **A special register defined by the system.
8 -1. **Data storage area (HDW/HDX): **Users store user data.
9 -1. **System data area (HUW): **A special register defined by the system.
10 -1. **System Data (HAW)**: System register used for power-off save.
11 -1. **Recipe index area (RPW): **System register used for recipe index.
7 +* **System data area (HSW): **A special register defined by the system.
8 +* **Data storage area (HDW/HDX): **Users store user data.
9 +* **System data area (HUW): **A special register defined by the system.
10 +* **System Data (HAW)**: System register used for power-off save.
11 +* **Recipe index area (RPW): **System register used for recipe index.
12 12  
13 13  HMI internal registers are divided into bit address and word address, which can be accessed in two ways (take HDW as an example).
14 14  
... ... @@ -241,8 +241,8 @@
241 241  * =2: HSX521.1=1, delete all trend graph.
242 242  * =4: HSX521.2=1, delete all alarms.
243 243  * =16: HSX521.4=1, delete history XY plot.
244 -* =32: HSX521.5=1, delete data records in SD card or flash dish;(Please make a setting which is saved to flash disk or SD card in project setting).
245 -* =64: HSX521.6=1, delete alarms records in SD card or flash dish; (Please make a setting which is saved to flash disk or SD card in project setting).
244 +* =32: HSX521.5=1, delete data records in SD card or USB flash disk;(Please make a setting which is saved to USB flash disk or SD card in project setting).
245 +* =64: HSX521.6=1, delete alarms records in SD card or USB flash disk; (Please make a setting which is saved to USB flash disk or SD card in project setting).
246 246  )))
247 247  |=(% style="width: 160px;" %)HSW522|(% style="width:282px" %)Copy and paste the alarm/data files in flash to the USB flash disk|(% style="width:452px" %)(((
248 248  * =0: No operation
... ... @@ -342,7 +342,7 @@
342 342  |=(% style="width: 160px;" %)HSW884|(% style="width:282px" %)Enter the system network configuration interface|(% style="width:452px" %)(((
343 343  * =0: Do not enter the network configuration interface
344 344  * =1: Enter the system network configuration interface.
345 -** (ig series HMI only supports to enter the system interface)
345 +** ig series HMI only supports to enter the system interface
346 346  
347 347  )))
348 348  |=(% style="width: 160px;" %)HSW885|(% style="width:282px" %)When the control object hides the address is read failed (communication failure), set the display mode of the object|(% style="width:452px" %)(((
... ... @@ -485,6 +485,8 @@
485 485  * =0, Default value
486 486  * =1, Release the alarm generated before the last power-down when starting up
487 487  )))
488 +|=(% style="width: 160px;" %)HSW1200|(% colspan="1" rowspan="2" style="width:282px" %)TSAP settings for HMI in the Siemens LOGO! 8 protocol(ig series or HMI V2.0)|(% style="width:452px" %)HMI local TSAP, which corresponds to the remote TSAP of PLC
489 +|=(% style="width: 160px;" %)HSW1201|(% style="width:452px" %)HMI remote TSAP, which corresponds to the local TSAP of PLC
488 488  |=(% style="width: 160px;" %)HSW1450|(% style="width:282px" %)Enable objects level password function|(% style="width:452px" %)(((
489 489  * =0, Disable
490 490  * =1, Enable
... ... @@ -512,6 +512,10 @@
512 512  * HSX1502.0=1: Modification comfirmed. Save the data of HSW1450~~HSW1501 to a file for immediate effect.
513 513  * HSX1502.1=1:Modification cancelled. Restore the current data of hSW1450-HSW1501 to the data saved in the file last time.
514 514  )))
517 +|=(% style="width: 160px;" %)HSW1509|(% style="width:282px" %)Curve width|(% style="width:452px" %)(((
518 +* =0: Use the curve width set by project default.
519 +* =1 to 10: use special register to set curve width.
520 +)))
515 515  |=(% style="width: 160px;" %)HSW1603|(% style="width:282px" %)Number of current unreleased alarms|(% style="width:452px" %)The number of current unreleased alarms in alarm record file.
516 516  |=(% style="width: 160px;" %)HSW1604|(% style="width:282px" %)The auxiliary judgment address when the control bit in the Object Lock fails to be read|(% style="width:452px" %)(((
517 517  * =0: The auxiliary address is invalid.
... ... @@ -614,6 +614,174 @@
614 614  * =1: Server connection is OK
615 615  )))
616 616  |=(% style="width: 160px;" %)HSW1761|(% style="width:282px" %)Display 4G network signal strength|(% style="width:452px" %)Signal strength: 0~~31. The greater the value ,the signal is stronger
623 +|=(% style="width: 160px;" %)(((
624 +HSW1762
625 +)))|(% colspan="1" rowspan="13" style="width:282px" %)(((
626 +Note: Valid when Ethernet2 of HMI is plugged into the network cable.
627 +①、When the Ethernet setting is enabled in the project parameters, this register displays the set value.
628 +②. When the Ethernet setting is not enabled in the engineering parameters, the register displays the Ethernet IP automatically acquired by the HMI.
629 +③. When the HMI is not plugged into the network cable, the register will show 0 whether the engineering parameters are set or not.
630 +④.IP related registers can be read and written (only static IP mode can be written).
631 +)))|(% style="width:452px" %)(((
632 +Ethernet2 Local IP address high byte 1
633 +)))
634 +|=(% style="width: 160px;" %)(((
635 +HSW1763
636 +)))|(% style="width:452px" %)(((
637 +Ethernet2 Local IP address high byte 2
638 +)))
639 +|=(% style="width: 160px;" %)(((
640 +HSW1764
641 +)))|(% style="width:452px" %)(((
642 +Ethernet2 Local IP address high byte 3
643 +)))
644 +|=(% style="width: 160px;" %)(((
645 +HSW1765
646 +)))|(% style="width:452px" %)(((
647 +Ethernet2 Local IP address high byte 4
648 +)))
649 +|=(% style="width: 160px;" %)(((
650 +HSW1766
651 +)))|(% style="width:452px" %)(((
652 +Ethernet2 Local mask IP address high byte 1
653 +)))
654 +|=(% style="width: 160px;" %)(((
655 +HSW1767
656 +)))|(% style="width:452px" %)(((
657 +Ethernet2 Local mask IP address high byte 2
658 +)))
659 +|=(% style="width: 160px;" %)(((
660 +HSW1768
661 +)))|(% style="width:452px" %)Ethernet2 Local mask IP address high byte 3
662 +|=(% style="width: 160px;" %)HSW1769|(% style="width:452px" %)Ethernet2 Local mask IP address high byte 4
663 +|=(% style="width: 160px;" %)(((
664 +HSW1770
665 +)))|(% style="width:452px" %)(((
666 +Ethernet2 Local gateway IP address high byte 1
667 +)))
668 +|=(% style="width: 160px;" %)(((
669 +HSW1771
670 +)))|(% style="width:452px" %)(((
671 +Ethernet2 Local gateway IP address high byte 2
672 +)))
673 +|=(% style="width: 160px;" %)(((
674 +HSW1772
675 +)))|(% style="width:452px" %)(((
676 +Ethernet2 Local gateway IP address high byte 3
677 +)))
678 +|=(% style="width: 160px;" %)(((
679 +HSW1773
680 +)))|(% style="width:452px" %)(((
681 +Ethernet2 Local gateway IP address high byte 4
682 +)))
683 +|=(% style="width: 160px;" %)(((
684 +HSW1774
685 +)))|(% style="width:452px" %)(((
686 +Ethernet2 Local Port Address
687 +)))
688 +|=(% style="width: 160px;" %)(((
689 +HSW1775
690 +)))|(% colspan="1" rowspan="6" style="width:282px" %)(((
691 +①Display the MAC code of Ethernet2 NIC
692 +
693 +(hexadecimal display)
694 +
695 +②Read-only mode, not modifiable
696 +)))|(% style="width:452px" %)(((
697 +Ethernet2 Local MAC code high byte 1
698 +)))
699 +|=(% style="width: 160px;" %)(((
700 +HSW1776
701 +)))|(% style="width:452px" %)(((
702 +Ethernet2 Local MAC code high byte 2
703 +)))
704 +|=(% style="width: 160px;" %)(((
705 +HSW1777
706 +)))|(% style="width:452px" %)(((
707 +Ethernet2 Local MAC code high byte 3
708 +)))
709 +|=(% style="width: 160px;" %)(((
710 +HSW1778
711 +)))|(% style="width:452px" %)(((
712 +Ethernet2 Local MAC code high byte 4
713 +)))
714 +|=(% style="width: 160px;" %)(((
715 +HSW1779
716 +)))|(% style="width:452px" %)(((
717 +Ethernet2 Local MAC code high byte 5
718 +)))
719 +|=(% style="width: 160px;" %)(((
720 +HSW1780
721 +)))|(% style="width:452px" %)(((
722 +Ethernet2 Local MAC code high byte 6
723 +)))
724 +|=(% style="width: 160px;" %)(((
725 +HSW1781
726 +)))|(% colspan="1" rowspan="8" style="width:282px" %)(((
727 +①Display and modify DNS1 and DNS2 of Ethernet2
728 +
729 +②Related registers can be read and written mode (only static IP mode can be written)
730 +)))|(% style="width:452px" %)(((
731 +Ethernet2 Local DNS1 address high byte 1
732 +)))
733 +|=(% style="width: 160px;" %)(((
734 +HSW1782
735 +)))|(% style="width:452px" %)(((
736 +Ethernet2 Local DNS1 address high byte 2
737 +)))
738 +|=(% style="width: 160px;" %)(((
739 +HSW1783
740 +)))|(% style="width:452px" %)(((
741 +Ethernet2 Local DNS1 address high byte 3
742 +)))
743 +|=(% style="width: 160px;" %)(((
744 +HSW1784
745 +)))|(% style="width:452px" %)(((
746 +Ethernet2 Local DNS1 address high byte 4
747 +)))
748 +|=(% style="width: 160px;" %)(((
749 +HSW1785
750 +)))|(% style="width:452px" %)(((
751 +Ethernet2 Local DNS2 address high byte 1
752 +)))
753 +|=(% style="width: 160px;" %)(((
754 +HSW1786
755 +)))|(% style="width:452px" %)(((
756 +Ethernet2 Local DNS2 address high byte 2
757 +)))
758 +|=(% style="width: 160px;" %)(((
759 +HSW1787
760 +)))|(% style="width:452px" %)(((
761 +Ethernet2 Local DNS2 address high byte 3
762 +)))
763 +|=(% style="width: 160px;" %)(((
764 +HSW1788
765 +)))|(% style="width:452px" %)(((
766 +Ethernet2 Local DNS2 address high byte 4
767 +)))
768 +|=(% style="width: 160px;" %)(((
769 +HSW1789
770 +)))|(% colspan="1" style="width:282px" %)(((
771 +Display or set the dynamic or static IP mode of Ethernet2
772 +)))|(% style="width:452px" %)(((
773 +HSX1789.0 = 0, Static IP mode
774 +
775 +HSX1789.0 = 1, dynamic IP mode
776 +)))
777 +|=(% style="width: 160px;" %)(((
778 +HSW1790
779 +)))|(% colspan="1" style="width:282px" %)(((
780 +Confirm Ethernet2 IP, subnet mask, gateway, DNS1, DNS2, and dynamic static IP settings
781 +)))|(% style="width:452px" %)(((
782 +~= 1, confirm the setting (i.e., after modifying IP-related information, set this address to 1, representing confirmation of the modification, after which it will be reset to 0)
783 +)))
784 +|=(% style="width: 160px;" %)(((
785 +HSW1791
786 +)))|(% colspan="1" style="width:282px" %)(((
787 +Network status of the Ethernet2 connection server
788 +)))|(% style="width:452px" %)(((
789 +~= 0, connection to the server is abnormal = 1, connection to the server is normal
790 +)))
617 617  |=(% style="width: 160px;" %)HSW1852|(% style="width:282px" %)Control the interval in two consecutive clicks|(% style="width:452px" %)Limit range: 1~~500ms. The default is 100 ms.
618 618  |=(% style="width: 160px;" %)HSW1853|(% style="width:282px" %)File format for exporting data records to USB flash drive or SD card|(% style="width:452px" %)(((
619 619  * =0: db database
... ... @@ -639,14 +639,87 @@
639 639  * =1: download firmware
640 640  * =2: enter the background
641 641  )))
816 +|=(% style="width: 160px;" %)HSW1865|(% style="width:282px" %)Priority connection to the cloud|(% style="width:452px" %)(((
817 +* =0: priority Ethernet
818 +* =1: priority WLAN
819 +* =2: priority 4G
820 +)))
821 +|=(% style="width: 160px;" %)HSW1866|(% style="width:282px" %)Delete the LUa extension module file|(% style="width:452px" %)(((
822 +* =0: delete;
823 +* = Others: do not delete
824 +)))
825 +|=(% style="width: 160px;" %)HSW1867|(% style="width:282px" %)Reset mode|(% style="width:452px" %)(((
826 +Monitor address is set during reset of reset switch, whether to cancel reset,
827 +
828 +* = 0: yes (default);
829 +* = 1: no
830 +)))
831 +|=(% style="width: 160px;" %)HSW1868|(% style="width:282px" %)Double-click or long press the record type table mode|(% style="width:452px" %)(((
832 +Controls whether the button pops up when double-clicking or long pressing on record type table object
833 +
834 +* = 0: yes (default);
835 +* = 1: no
836 +)))
837 +|=(% style="width: 160px;" %)(((
838 +HSW1869
839 +)))|(% style="width:282px" %)(((
840 +Dynamic screensaver countdown
841 +)))|(% style="width:452px" %)(((
842 +Countdown to enter dynamic screensaver effect, unit (S)
843 +)))
844 +|=(% style="width: 160px;" %)(((
845 +HSW1870
846 +)))|(% style="width:282px" %)(((
847 +Display or set the dynamic or static IP mode of Ethernet1
848 +)))|(% style="width:452px" %)(((
849 +HSX1870.0 = 0, Static IP mode
850 +
851 +HSX1870.0 = 1, dynamic IP mode
852 +)))
853 +|=(% style="width: 160px;" %)(((
854 +HSW1871
855 +)))|(% style="width:282px" %)(((
856 +Confirm the IP, subnet mask, gateway, DNS1, DNS2, and dynamic static IP settings for Ethernet1
857 +)))|(% style="width:452px" %)(((
858 +~= 1, confirm the setting (i.e., after modifying IP-related information, set this address to 1, representing confirmation of the modification, after which it will be reset to 0)
859 +)))
860 +|=(% style="width: 160px;" %)(((
861 +HSW1872
862 +)))|(% colspan="1" rowspan="8" style="width:282px" %)(((
863 +①Display and modify DNS1 and DNS2 of Ethernet1
864 +
865 +②Related registers can be read and written mode (only static IP mode can be written)
866 +)))|(% style="width:452px" %)(((
867 +Ethernet1 Local DNS1 address high byte 1
868 +)))
869 +|=(% style="width: 160px;" %)(((
870 +HSW1873
871 +)))|(% style="width:452px" %)Ethernet1 Local DNS1 address high byte 2
872 +|=(% style="width: 160px;" %)(((
873 +HSW1874
874 +)))|(% style="width:452px" %)Ethernet1 Local DNS1 address high byte 3
875 +|=(% style="width: 160px;" %)(((
876 +HSW1875
877 +)))|(% style="width:452px" %)Ethernet1 Local DNS1 address high byte 4
878 +|=(% style="width: 160px;" %)(((
879 +HSW1876
880 +)))|(% style="width:452px" %)Ethernet1 Local DNS2 address high byte 1
881 +|=(% style="width: 160px;" %)(((
882 +HSW1877
883 +)))|(% style="width:452px" %)Ethernet1 Local DNS2 address high byte 2
884 +|=(% style="width: 160px;" %)(((
885 +HSW1878
886 +)))|(% style="width:452px" %)Ethernet1 Local DNS2 address high byte 3
887 +|=(% style="width: 160px;" %)(((
888 +HSW1879
889 +)))|(% style="width:452px" %)Ethernet1 Local DNS2 address high byte 4
642 642  |=(% style="width: 160px;" %)HSW10000~~19999|(% style="width:282px" %)Power-down storage area|(% style="width:452px" %)After restart, the data remains
643 643  |=(% style="width: 160px;" %)HSW10035|(% rowspan="13" style="width:282px" %)(((
644 -**✎Note: **Only valid when the HMI is plugged into the Ethernet cable.
645 -
646 -1. If Ethernet settings is enabled in project parameters, this register displays the set value.
647 -1. If Ethernet settings is not enabled in project parameters, IP would automatically obtained IP.
648 -1. If HMI is not connected to the network, the register is displayed as 0 whether the engineering parameters are set.
649 -1. 4. All IP registers of HMI are read-only.
892 +Note: Valid when Ethernet1 of HMI is plugged into the network cable.
893 +①、When the Ethernet setting is enabled in the project parameters, this register displays the set value.
894 +②. When the Ethernet setting is not enabled in the engineering parameters, the register displays the Ethernet IP automatically acquired by the HMI.
895 +③. When the HMI is not plugged into the network cable, the register will show 0 whether the engineering parameters are set or not.
896 +④.IP related registers can be read and written (only static IP mode can be written).
650 650  )))|(% style="width:452px" %)Local IP address high byte 1
651 651  |=(% style="width: 160px;" %)HSW10036|(% style="width:452px" %)Local IP address high byte 2
652 652  |=(% style="width: 160px;" %)HSW10037|(% style="width:452px" %)Local IP address high byte 3
... ... @@ -661,9 +661,11 @@
661 661  |=(% style="width: 160px;" %)HSW10046|(% style="width:452px" %)Local gateway address high byte 4
662 662  |=(% style="width: 160px;" %)HSW10047|(% style="width:452px" %)Local port address
663 663  |=(% style="width: 160px;" %)HSW10048|(% rowspan="6" style="width:282px" %)(((
664 -Displays the MAC code of the current network card
911 +Display the MAC code of Ethernet1 NIC
665 665  
666 -(Hexadecimal display)
913 +(hexadecimal display)
914 +
915 +②Read-only mode, not modifiable
667 667  )))|(% style="width:452px" %)Local MAC code high word 1
668 668  |=(% style="width: 160px;" %)HSW10049|(% style="width:452px" %)Local MAC code high word 2
669 669  |=(% style="width: 160px;" %)HSW10050|(% style="width:452px" %)Local MAC code high word 3
... ... @@ -670,7 +670,7 @@
670 670  |=(% style="width: 160px;" %)HSW10051|(% style="width:452px" %)Local MAC code high word 4
671 671  |=(% style="width: 160px;" %)HSW10052|(% style="width:452px" %)Local MAC code high word 5
672 672  |=(% style="width: 160px;" %)HSW10053|(% style="width:452px" %)Local MAC code high word 6
673 -|=(% style="width: 160px;" %)HSW10118|(% colspan="1" rowspan="2" style="width:282px" %)TSAP settings for HMI in the Siemens logo! 8 protocol|(% style="width:452px" %)HMI local TSAP, which corresponds to the remote TSAP of PLC
922 +|=(% style="width: 160px;" %)HSW10118|(% colspan="1" rowspan="2" style="width:282px" %)TSAP settings for HMI in the Siemens LOGO! 8 protocol|(% style="width:452px" %)HMI local TSAP, which corresponds to the remote TSAP of PLC
674 674  |=(% style="width: 160px;" %)HSW10119|(% style="width:452px" %)HMI remote TSAP, which corresponds to the local TSAP of PLC
675 675  |=(% style="width: 160px;" %)HSW10461~~10493|(% style="width:282px" %)Remote access password|(% style="width:452px" %)8-character remote access password
676 676  |=(% style="width: 160px;" %)HSW10494~~10558|(% style="width:282px" %)Machine ID (Read only)|(% style="width:452px" %)Machine ID for remote access (read only 64-bit)
... ... @@ -752,11 +752,38 @@
752 752  )))
753 753  |=(% style="width: 160px;" %)HSW11760|(% style="width:282px" %)Screensaver countdown|(% style="width:452px" %)Display the countdown to enter the Screensaver, unit: second.
754 754  |=(% style="width: 160px;" %)HSW11761|(% style="width:282px" %)Screensaver screen number|(% style="width:452px" %)Set the screen number for Screensaver
1004 +|=(% style="width: 160px;" %)(((
1005 +HSW11762
1006 +)))|(% style="width:282px" %)(((
1007 +Dynamic screensaver control address
1008 +)))|(% style="width:452px" %)(((
1009 +HSX11762.0=0, initialize with project configuration;
755 755  
756 -== **Serial port communication configuration** ==
1011 +HSX11762.0=1, initialize with special register configuration;
757 757  
1013 +HSX11762.1=0, disable dynamic screensaver;
1014 +
1015 +HSX11762.1=1, enable dynamic screensaver
1016 +)))
1017 +|=(% style="width: 160px;" %)(((
1018 +HSW11763
1019 +)))|(% style="width:282px" %)(((
1020 +Waiting time to enter the dynamic screensaver
1021 +)))|(% style="width:452px" %)(((
1022 +Waiting time when the screen is not operated, range 1~~720 minutes
1023 +)))
1024 +|=(% style="width: 160px;" %)(((
1025 +HSW11764
1026 +)))|(% style="width:282px" %)(((
1027 +Animated screensaver animation type
1028 +)))|(% style="width:452px" %)(((
1029 +~=0: Raster,=1: Blinds,=2: Bubble
1030 +)))
1031 +
1032 +== Serial port communication configuration ==
1033 +
758 758  (% class="table-bordered" %)
759 -|=(% style="width: 102px;" %)Port|=(% style="width: 173px;" %)**Function**|=(% style="width: 122px;" %)**Address**|=(% colspan="2" style="width: 506px;" %)**Description**
1035 +|=(% scope="row" style="width: 102px;" %)Port|=(% style="width: 173px;" %)**Function**|=(% style="width: 122px;" %)**Address**|=(% colspan="2" style="width: 506px;" %)**Description**
760 760  |(% colspan="1" rowspan="11" style="width:102px" %)COM1|(% style="width:173px" %)Communication mode|(% style="width:122px" %)HSW10061|(% colspan="2" style="width:506px" %)(((
761 761  * =0: RS232
762 762  * =1: RS485
... ... @@ -786,10 +786,22 @@
786 786  * =1: ODD
787 787  * =2: EVEN
788 788  )))
789 -|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10066|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000
790 -|(% style="width:173px" %)reveive timeout|(% style="width:122px" %)HSW10067|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000
791 -|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10068|(% colspan="2" style="width:506px" %)Unit: times. Range: 0~~100
792 -|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10069|(% colspan="2" style="width:506px" %)Unit: s. Range: 0~~300
1065 +|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10066|(% colspan="2" style="width:506px" %)(((
1066 +* Unit: ms.
1067 +* Range: 0 to 30000
1068 +)))
1069 +|(% style="width:173px" %)reveive timeout|(% style="width:122px" %)HSW10067|(% colspan="2" style="width:506px" %)(((
1070 +* Unit: ms.
1071 +* Range: 0 to 30000
1072 +)))
1073 +|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10068|(% colspan="2" style="width:506px" %)(((
1074 +* Unit: times.
1075 +* Range: 0 to 100
1076 +)))
1077 +|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10069|(% colspan="2" style="width:506px" %)(((
1078 +* Unit: s.
1079 +* Range: 0 to 300
1080 +)))
793 793  |(% style="width:173px" %)HMI station number|(% style="width:122px" %)HSW10070|(% colspan="2" style="width:506px" %)
794 794  |(% style="width:173px" %)PLC station number|(% style="width:122px" %)HSW10071|(% colspan="2" style="width:506px" %)
795 795  |(% colspan="1" rowspan="11" style="width:102px" %)COM1-2|(% style="width:173px" %)Communication mode|(% style="width:122px" %)HSW10094|(% colspan="2" style="width:506px" %)(((
... ... @@ -822,10 +822,22 @@
822 822  * =1: ODD
823 823  * =2: EVEN
824 824  )))
825 -|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10099|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000
826 -|(% style="width:173px" %)receive timeout|(% style="width:122px" %)HSW10100|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000
827 -|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10101|(% colspan="2" style="width:506px" %)Unit: times. Range: 0~~100
828 -|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10102|(% colspan="2" style="width:506px" %)Unit: s. Range: 0~~30
1113 +|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10099|(% colspan="2" style="width:506px" %)(((
1114 +* Unit: ms.
1115 +* Range: 0 to 30000
1116 +)))
1117 +|(% style="width:173px" %)receive timeout|(% style="width:122px" %)HSW10100|(% colspan="2" style="width:506px" %)(((
1118 +* Unit: ms.
1119 +* Range: 0 to 30000
1120 +)))
1121 +|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10101|(% colspan="2" style="width:506px" %)(((
1122 +* Unit: times.
1123 +* Range: 0 to 100
1124 +)))
1125 +|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10102|(% colspan="2" style="width:506px" %)(((
1126 +* Unit: s.
1127 +* Range: 0 to 30
1128 +)))
829 829  |(% style="width:173px" %)HMI station number|(% style="width:122px" %)HSW10103|(% colspan="2" style="width:506px" %)
830 830  |(% style="width:173px" %)PLC station number|(% style="width:122px" %)HSW10104|(% colspan="2" style="width:506px" %)
831 831  |(% colspan="1" rowspan="11" style="width:102px" %)COM1-3|(% style="width:173px" %)Communication mode|(% style="width:122px" %)HSW10120|(% colspan="2" style="width:506px" %)(((
... ... @@ -858,10 +858,22 @@
858 858  * =1: ODD
859 859  * =2: EVEN
860 860  )))
861 -|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10125|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000
862 -|(% style="width:173px" %)receive timeout|(% style="width:122px" %)HSW10126|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000
863 -|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10127|(% colspan="2" style="width:506px" %)Unit: times. Range: 0~~100
864 -|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10128|(% colspan="2" style="width:506px" %)Unit: s. Range: 0~~30
1161 +|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10125|(% colspan="2" style="width:506px" %)(((
1162 +* Unit: ms.
1163 +* Range: 0 to 30000
1164 +)))
1165 +|(% style="width:173px" %)receive timeout|(% style="width:122px" %)HSW10126|(% colspan="2" style="width:506px" %)(((
1166 +* Unit: ms.
1167 +* Range: 0 to 30000
1168 +)))
1169 +|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10127|(% colspan="2" style="width:506px" %)(((
1170 +* Unit: times.
1171 +* Range: 0 to 100
1172 +)))
1173 +|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10128|(% colspan="2" style="width:506px" %)(((
1174 +* Unit: s.
1175 +* Range: 0 to 30
1176 +)))
865 865  |(% style="width:173px" %)HMI station number|(% style="width:122px" %)HSW10129|(% colspan="2" style="width:506px" %)
866 866  |(% style="width:173px" %)PLC station number|(% style="width:122px" %)HSW10130|(% colspan="2" style="width:506px" %)
867 867  |(% colspan="1" rowspan="11" style="width:102px" %)COM2|(% style="width:173px" %)Communication mode|(% style="width:122px" %)HSW10072|(% colspan="2" style="width:506px" %)(((
... ... @@ -892,10 +892,22 @@
892 892  * =1: ODD
893 893  * =2: EVEN
894 894  )))
895 -|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10077|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000
896 -|(% style="width:173px" %)receive timeout|(% style="width:122px" %)HSW10078|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000
897 -|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10079|(% colspan="2" style="width:506px" %)Unit: times. Range: 0~~100
898 -|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10080|(% colspan="2" style="width:506px" %)Unit: s. Range: 0~~30
1207 +|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10077|(% colspan="2" style="width:506px" %)(((
1208 +* Unit: ms.
1209 +* Range: 0 to 30000
1210 +)))
1211 +|(% style="width:173px" %)receive timeout|(% style="width:122px" %)HSW10078|(% colspan="2" style="width:506px" %)(((
1212 +* Unit: ms.
1213 +* Range: 0 to 30000
1214 +)))
1215 +|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10079|(% colspan="2" style="width:506px" %)(((
1216 +* Unit: times.
1217 +* Range: 0 to 100
1218 +)))
1219 +|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10080|(% colspan="2" style="width:506px" %)(((
1220 +* Unit: s.
1221 +* Range: 0 to 30
1222 +)))
899 899  |(% style="width:173px" %)HMI station number|(% style="width:122px" %)HSW10081|(% colspan="2" style="width:506px" %)
900 900  |(% style="width:173px" %)PLC station number|(% style="width:122px" %)HSW10082|(% colspan="2" style="width:506px" %)
901 901  |(% colspan="1" rowspan="11" style="width:102px" %)COM2-2|(% style="width:173px" %)Communication mode|(% style="width:122px" %)HSW10105|(% colspan="2" style="width:506px" %)(((
... ... @@ -926,10 +926,22 @@
926 926  * =1: ODD
927 927  * =2: EVEN
928 928  )))
929 -|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10110|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000
930 -|(% style="width:173px" %)receive timeout|(% style="width:122px" %)HSW10111|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000
931 -|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10112|(% colspan="2" style="width:506px" %)Unit: times. Range: 0~~100
932 -|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10113|(% colspan="2" style="width:506px" %)Unit: s. Range: 0~~30
1253 +|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10110|(% colspan="2" style="width:506px" %)(((
1254 +* Unit: ms.
1255 +* Range: 0 to 30000
1256 +)))
1257 +|(% style="width:173px" %)receive timeout|(% style="width:122px" %)HSW10111|(% colspan="2" style="width:506px" %)(((
1258 +* Unit: ms.
1259 +* Range: 0 to 30000
1260 +)))
1261 +|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10112|(% colspan="2" style="width:506px" %)(((
1262 +* Unit: times.
1263 +* Range: 0 to 100
1264 +)))
1265 +|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10113|(% colspan="2" style="width:506px" %)(((
1266 +* Unit: s.
1267 +* Range: 0 to 30
1268 +)))
933 933  |(% style="width:173px" %)HMI station number|(% style="width:122px" %)HSW10114|(% colspan="2" style="width:506px" %)
934 934  |(% style="width:173px" %)PLC station number|(% style="width:122px" %)HSW10115|(% colspan="2" style="width:506px" %)
935 935  |(% colspan="1" rowspan="11" style="width:102px" %)COM3|(% style="width:173px" %)Communication mode|(% style="width:122px" %)HSW10083|(% colspan="2" style="width:506px" %)(((
... ... @@ -959,29 +959,48 @@
959 959  * =1: ODD
960 960  * =2: EVEN
961 961  )))
962 -|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10088|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000
963 -|(% style="width:173px" %)receive timeout|(% style="width:122px" %)HSW10089|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000
964 -|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10090|(% colspan="2" style="width:506px" %)Unit: times. Range: 0~~100
965 -|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10091|(% colspan="2" style="width:506px" %)Unit: s. Range: 0~~30
1298 +|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10088|(% colspan="2" style="width:506px" %)(((
1299 +* Unit: ms.
1300 +* Range: 0 to 30000
1301 +)))
1302 +|(% style="width:173px" %)receive timeout|(% style="width:122px" %)HSW10089|(% colspan="2" style="width:506px" %)(((
1303 +* Unit: ms.
1304 +* Range: 0 to 30000
1305 +)))
1306 +|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10090|(% colspan="2" style="width:506px" %)(((
1307 +* Unit: times.
1308 +* Range: 0 to 100
1309 +)))
1310 +|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10091|(% colspan="2" style="width:506px" %)(((
1311 +* Unit: s.
1312 +* Range: 0 to 30
1313 +)))
966 966  |(% style="width:173px" %)HMI station number|(% style="width:122px" %)HSW10092|(% colspan="2" style="width:506px" %)
967 967  |(% style="width:173px" %)PLC station number|(% style="width:122px" %)HSW10093|(% colspan="2" style="width:506px" %)
968 968  |(% colspan="1" rowspan="2" style="width:102px" %)CAN port|(% style="width:173px" %)CAN1 baud rate|(% style="width:122px" %)HSW010116|(% style="width:299px" %)(((
969 -Unit: K, the baud rate must be an integer, for example, when the baud rate required is 250000, just enter 250.
1317 +Unit: K, the baud rate must be an integer.
1318 +
1319 +For example, when the baud rate required is 250000, just enter 250.
970 970  )))|(% colspan="1" rowspan="2" style="width:218px" %)**✎Note: **If baud rate has been modified,please wait 5 seconds,then restart the HMI to take effect.
971 -|(% style="width:173px" %)CAN2 baud rate|(% style="width:122px" %)HSW010117|(% style="width:299px" %)Unit: K, the baud rate must be an integer, for example, when the baud rate required is 250000, just enter 250.
1321 +|(% style="width:173px" %)CAN2 baud rate|(% style="width:122px" %)HSW010117|(% style="width:299px" %)(((
1322 +Unit: K, the baud rate must be an integer.
972 972  
973 -== **Ethernet communication configuration** ==
1324 +For example, when the baud rate required is 250000, just enter 250.
1325 +)))
974 974  
1327 +== Ethernet communication configuration ==
1328 +
975 975  (% class="table-bordered" %)
976 -|=(% style="width: 40px;" %)**No.**|=(% style="width: 295px;" %)**Function**|=(% style="width: 220px;" %)**Address**|=(% style="width: 336px;" %)**Description**
1330 +|(% style="width:40px" %)**No.**|(% style="width:295px" %)**Function**|(% style="width:220px" %)**Address**|(% style="width:336px" %)**Description**
977 977  |(% rowspan="7" style="width:40px" %)1|(% colspan="1" rowspan="7" style="width:295px" %)Ethernet parameter configuration for communication number 1 in list. Configure those addresses according to connected device. After configuration, wait for 5 seconds and restart the HMI.|(% style="width:220px" %)HSW11004|(% style="width:336px" %)Device IP address high word 1
978 978  |(% style="width:220px" %)HSW11005|(% style="width:336px" %)Device IP address high word 2
979 979  |(% style="width:220px" %)HSW11006|(% style="width:336px" %)Device IP address high word 3
980 980  |(% style="width:220px" %)HSW11007|(% style="width:336px" %)Device IP address high word 4
981 981  |(% style="width:220px" %)HSW11008|(% style="width:336px" %)Device Port number
982 -|(% style="width:220px" %)HSW11009|=(% style="width: 336px;" %)(((
983 -* =2 TCP
984 -* =3 UDP
1336 +|(% style="width:220px" %)HSW11009|(% style="width:336px" %)(((
1337 +~=2 TCP
1338 +
1339 +~=3 UDP
985 985  )))
986 986  |(% style="width:220px" %)HSW11010|(% style="width:336px" %)Reserved
987 987  |(% rowspan="7" style="width:40px" %)2|(% colspan="1" rowspan="7" style="width:295px" %)Ethernet parameter configuration for communication number 2 in list. Configure those addresses according to connected device. After configuration, wait for 5 seconds and restart the HMI.|(% style="width:220px" %)HSW11011|(% style="width:336px" %)Device IP address high word 1
... ... @@ -989,9 +989,10 @@
989 989  |(% style="width:220px" %)HSW11013|(% style="width:336px" %)Device IP address high word 3
990 990  |(% style="width:220px" %)HSW11014|(% style="width:336px" %)Device IP address high word 4
991 991  |(% style="width:220px" %)HSW11015|(% style="width:336px" %)Device Port number
992 -|(% style="width:220px" %)HSW11016|=(% style="width: 336px;" %)(((
993 -* =2 TCP
994 -* =3 UDP
1347 +|(% style="width:220px" %)HSW11016|(% style="width:336px" %)(((
1348 +~=2 TCP
1349 +
1350 +~=3 UDP
995 995  )))
996 996  |(% style="width:220px" %)HSW11017|(% style="width:336px" %)Reserved
997 997  |(% style="width:40px" %)…|(% style="width:295px" %) |(% style="width:220px" %)…|(% style="width:336px" %)…
... ... @@ -1000,7 +1000,11 @@
1000 1000  |(% style="width:220px" %)HSW11223|(% style="width:336px" %)Device IP address high word 3
1001 1001  |(% style="width:220px" %)HSW11224|(% style="width:336px" %)Device IP address high word 4
1002 1002  |(% style="width:220px" %)HSW11225|(% style="width:336px" %)Device Port number
1003 -|(% style="width:220px" %)HSW11226|=(% style="width: 336px;" %)2 TCP; =3 UDP
1359 +|(% style="width:220px" %)HSW11226|(% style="width:336px" %)(((
1360 +~=2 TCP;
1361 +
1362 +~=3 UDP
1363 +)))
1004 1004  |(% style="width:220px" %)HSW11227|(% style="width:336px" %)Reserved
1005 1005  
1006 1006  (% class="box infomessage" %)
... ... @@ -1008,7 +1008,7 @@
1008 1008  **✎Note:** The number of Ethernet connections supported by different HMI series varies.
1009 1009  )))
1010 1010  
1011 -== **Communication control** ==
1371 +== Communication control ==
1012 1012  
1013 1013  (% class="table-bordered" %)
1014 1014  |=(% style="width: 135px;" %)**Communication No.**|=(% style="width: 102px;" %)**Station No.**|=(% style="width: 185px;" %)**Control bit**|=(% style="width: 191px;" %)**Communication lamp**|=(% style="width: 271px;" %)**Description**