Changes for page 13 HMI Internal Registers
Last modified by Jett on 2025/04/28 16:07
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -4,11 +4,11 @@ 4 4 5 5 *HSW, HDW, HUW, HAW are word address, HSX, HDX, HUX, HAX are bit address. 6 6 7 - 1.**System data area (HSW): **A special register defined by the system.8 - 1.**Data storage area (HDW/HDX): **Users store user data.9 - 1.**System data area (HUW): **A special register defined by the system.10 - 1.**System Data (HAW)**: System register used for power-off save.11 - 1.**Recipe index area (RPW): **System register used for recipe index.7 +* **System data area (HSW): **A special register defined by the system. 8 +* **Data storage area (HDW/HDX): **Users store user data. 9 +* **System data area (HUW): **A special register defined by the system. 10 +* **System Data (HAW)**: System register used for power-off save. 11 +* **Recipe index area (RPW): **System register used for recipe index. 12 12 13 13 HMI internal registers are divided into bit address and word address, which can be accessed in two ways (take HDW as an example). 14 14 ... ... @@ -342,7 +342,7 @@ 342 342 |=(% style="width: 160px;" %)HSW884|(% style="width:282px" %)Enter the system network configuration interface|(% style="width:452px" %)((( 343 343 * =0: Do not enter the network configuration interface 344 344 * =1: Enter the system network configuration interface. 345 -** (ig series HMI only supports to enter the system interface)345 +** ig series HMI only supports to enter the system interface 346 346 347 347 ))) 348 348 |=(% style="width: 160px;" %)HSW885|(% style="width:282px" %)When the control object hides the address is read failed (communication failure), set the display mode of the object|(% style="width:452px" %)((( ... ... @@ -512,6 +512,10 @@ 512 512 * HSX1502.0=1: Modification comfirmed. Save the data of HSW1450~~HSW1501 to a file for immediate effect. 513 513 * HSX1502.1=1:Modification cancelled. Restore the current data of hSW1450-HSW1501 to the data saved in the file last time. 514 514 ))) 515 +|=(% style="width: 160px;" %)HSW1509|(% style="width:282px" %)Curve width|(% style="width:452px" %)((( 516 +* =0: Use the curve width set by project default. 517 +* =1 to 10: use special register to set curve width. 518 +))) 515 515 |=(% style="width: 160px;" %)HSW1603|(% style="width:282px" %)Number of current unreleased alarms|(% style="width:452px" %)The number of current unreleased alarms in alarm record file. 516 516 |=(% style="width: 160px;" %)HSW1604|(% style="width:282px" %)The auxiliary judgment address when the control bit in the Object Lock fails to be read|(% style="width:452px" %)((( 517 517 * =0: The auxiliary address is invalid. ... ... @@ -639,6 +639,22 @@ 639 639 * =1: download firmware 640 640 * =2: enter the background 641 641 ))) 646 +|=(% style="width: 160px;" %)HSW1866|(% style="width:282px" %)Delete the LUa extension module file|(% style="width:452px" %)((( 647 +* =1, delete; 648 +* = Others, do not delete 649 +))) 650 +|=(% style="width: 160px;" %)HSW1867|(% style="width:282px" %)Reset mode|(% style="width:452px" %)((( 651 +Monitor address is set during reset of reset switch, whether to cancel reset, 652 + 653 +* = 0, yes (default); 654 +* = 1, no 655 +))) 656 +|=(% style="width: 160px;" %)HSW1868|(% style="width:282px" %)Double-click or long press the record type table mode|(% style="width:452px" %)((( 657 +Controls whether the button pops up when double-clicking or long pressing on record type table object 658 + 659 +* = 0, yes (default); 660 +* = 1, no 661 +))) 642 642 |=(% style="width: 160px;" %)HSW10000~~19999|(% style="width:282px" %)Power-down storage area|(% style="width:452px" %)After restart, the data remains 643 643 |=(% style="width: 160px;" %)HSW10035|(% rowspan="13" style="width:282px" %)((( 644 644 **✎Note: **Only valid when the HMI is plugged into the Ethernet cable. ... ... @@ -753,10 +753,10 @@ 753 753 |=(% style="width: 160px;" %)HSW11760|(% style="width:282px" %)Screensaver countdown|(% style="width:452px" %)Display the countdown to enter the Screensaver, unit: second. 754 754 |=(% style="width: 160px;" %)HSW11761|(% style="width:282px" %)Screensaver screen number|(% style="width:452px" %)Set the screen number for Screensaver 755 755 756 -== **Serial port communication configuration**==776 +== Serial port communication configuration == 757 757 758 758 (% class="table-bordered" %) 759 -|=(% style="width: 102px;" %)Port|=(% style="width: 173px;" %)**Function**|=(% style="width: 122px;" %)**Address**|=(% colspan="2" style="width: 506px;" %)**Description** 779 +|=(% scope="row" style="width: 102px;" %)Port|=(% style="width: 173px;" %)**Function**|=(% style="width: 122px;" %)**Address**|=(% colspan="2" style="width: 506px;" %)**Description** 760 760 |(% colspan="1" rowspan="11" style="width:102px" %)COM1|(% style="width:173px" %)Communication mode|(% style="width:122px" %)HSW10061|(% colspan="2" style="width:506px" %)((( 761 761 * =0: RS232 762 762 * =1: RS485 ... ... @@ -786,10 +786,22 @@ 786 786 * =1: ODD 787 787 * =2: EVEN 788 788 ))) 789 -|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10066|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000 790 -|(% style="width:173px" %)reveive timeout|(% style="width:122px" %)HSW10067|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000 791 -|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10068|(% colspan="2" style="width:506px" %)Unit: times. Range: 0~~100 792 -|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10069|(% colspan="2" style="width:506px" %)Unit: s. Range: 0~~300 809 +|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10066|(% colspan="2" style="width:506px" %)((( 810 +* Unit: ms. 811 +* Range: 0 to 30000 812 +))) 813 +|(% style="width:173px" %)reveive timeout|(% style="width:122px" %)HSW10067|(% colspan="2" style="width:506px" %)((( 814 +* Unit: ms. 815 +* Range: 0 to 30000 816 +))) 817 +|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10068|(% colspan="2" style="width:506px" %)((( 818 +* Unit: times. 819 +* Range: 0 to 100 820 +))) 821 +|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10069|(% colspan="2" style="width:506px" %)((( 822 +* Unit: s. 823 +* Range: 0 to 300 824 +))) 793 793 |(% style="width:173px" %)HMI station number|(% style="width:122px" %)HSW10070|(% colspan="2" style="width:506px" %) 794 794 |(% style="width:173px" %)PLC station number|(% style="width:122px" %)HSW10071|(% colspan="2" style="width:506px" %) 795 795 |(% colspan="1" rowspan="11" style="width:102px" %)COM1-2|(% style="width:173px" %)Communication mode|(% style="width:122px" %)HSW10094|(% colspan="2" style="width:506px" %)((( ... ... @@ -822,10 +822,22 @@ 822 822 * =1: ODD 823 823 * =2: EVEN 824 824 ))) 825 -|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10099|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000 826 -|(% style="width:173px" %)receive timeout|(% style="width:122px" %)HSW10100|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000 827 -|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10101|(% colspan="2" style="width:506px" %)Unit: times. Range: 0~~100 828 -|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10102|(% colspan="2" style="width:506px" %)Unit: s. Range: 0~~30 857 +|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10099|(% colspan="2" style="width:506px" %)((( 858 +* Unit: ms. 859 +* Range: 0 to 30000 860 +))) 861 +|(% style="width:173px" %)receive timeout|(% style="width:122px" %)HSW10100|(% colspan="2" style="width:506px" %)((( 862 +* Unit: ms. 863 +* Range: 0 to 30000 864 +))) 865 +|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10101|(% colspan="2" style="width:506px" %)((( 866 +* Unit: times. 867 +* Range: 0 to 100 868 +))) 869 +|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10102|(% colspan="2" style="width:506px" %)((( 870 +* Unit: s. 871 +* Range: 0 to 30 872 +))) 829 829 |(% style="width:173px" %)HMI station number|(% style="width:122px" %)HSW10103|(% colspan="2" style="width:506px" %) 830 830 |(% style="width:173px" %)PLC station number|(% style="width:122px" %)HSW10104|(% colspan="2" style="width:506px" %) 831 831 |(% colspan="1" rowspan="11" style="width:102px" %)COM1-3|(% style="width:173px" %)Communication mode|(% style="width:122px" %)HSW10120|(% colspan="2" style="width:506px" %)((( ... ... @@ -858,10 +858,22 @@ 858 858 * =1: ODD 859 859 * =2: EVEN 860 860 ))) 861 -|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10125|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000 862 -|(% style="width:173px" %)receive timeout|(% style="width:122px" %)HSW10126|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000 863 -|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10127|(% colspan="2" style="width:506px" %)Unit: times. Range: 0~~100 864 -|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10128|(% colspan="2" style="width:506px" %)Unit: s. Range: 0~~30 905 +|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10125|(% colspan="2" style="width:506px" %)((( 906 +* Unit: ms. 907 +* Range: 0 to 30000 908 +))) 909 +|(% style="width:173px" %)receive timeout|(% style="width:122px" %)HSW10126|(% colspan="2" style="width:506px" %)((( 910 +* Unit: ms. 911 +* Range: 0 to 30000 912 +))) 913 +|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10127|(% colspan="2" style="width:506px" %)((( 914 +* Unit: times. 915 +* Range: 0 to 100 916 +))) 917 +|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10128|(% colspan="2" style="width:506px" %)((( 918 +* Unit: s. 919 +* Range: 0 to 30 920 +))) 865 865 |(% style="width:173px" %)HMI station number|(% style="width:122px" %)HSW10129|(% colspan="2" style="width:506px" %) 866 866 |(% style="width:173px" %)PLC station number|(% style="width:122px" %)HSW10130|(% colspan="2" style="width:506px" %) 867 867 |(% colspan="1" rowspan="11" style="width:102px" %)COM2|(% style="width:173px" %)Communication mode|(% style="width:122px" %)HSW10072|(% colspan="2" style="width:506px" %)((( ... ... @@ -892,10 +892,22 @@ 892 892 * =1: ODD 893 893 * =2: EVEN 894 894 ))) 895 -|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10077|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000 896 -|(% style="width:173px" %)receive timeout|(% style="width:122px" %)HSW10078|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000 897 -|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10079|(% colspan="2" style="width:506px" %)Unit: times. Range: 0~~100 898 -|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10080|(% colspan="2" style="width:506px" %)Unit: s. Range: 0~~30 951 +|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10077|(% colspan="2" style="width:506px" %)((( 952 +* Unit: ms. 953 +* Range: 0 to 30000 954 +))) 955 +|(% style="width:173px" %)receive timeout|(% style="width:122px" %)HSW10078|(% colspan="2" style="width:506px" %)((( 956 +* Unit: ms. 957 +* Range: 0 to 30000 958 +))) 959 +|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10079|(% colspan="2" style="width:506px" %)((( 960 +* Unit: times. 961 +* Range: 0 to 100 962 +))) 963 +|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10080|(% colspan="2" style="width:506px" %)((( 964 +* Unit: s. 965 +* Range: 0 to 30 966 +))) 899 899 |(% style="width:173px" %)HMI station number|(% style="width:122px" %)HSW10081|(% colspan="2" style="width:506px" %) 900 900 |(% style="width:173px" %)PLC station number|(% style="width:122px" %)HSW10082|(% colspan="2" style="width:506px" %) 901 901 |(% colspan="1" rowspan="11" style="width:102px" %)COM2-2|(% style="width:173px" %)Communication mode|(% style="width:122px" %)HSW10105|(% colspan="2" style="width:506px" %)((( ... ... @@ -926,10 +926,22 @@ 926 926 * =1: ODD 927 927 * =2: EVEN 928 928 ))) 929 -|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10110|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000 930 -|(% style="width:173px" %)receive timeout|(% style="width:122px" %)HSW10111|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000 931 -|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10112|(% colspan="2" style="width:506px" %)Unit: times. Range: 0~~100 932 -|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10113|(% colspan="2" style="width:506px" %)Unit: s. Range: 0~~30 997 +|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10110|(% colspan="2" style="width:506px" %)((( 998 +* Unit: ms. 999 +* Range: 0 to 30000 1000 +))) 1001 +|(% style="width:173px" %)receive timeout|(% style="width:122px" %)HSW10111|(% colspan="2" style="width:506px" %)((( 1002 +* Unit: ms. 1003 +* Range: 0 to 30000 1004 +))) 1005 +|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10112|(% colspan="2" style="width:506px" %)((( 1006 +* Unit: times. 1007 +* Range: 0 to 100 1008 +))) 1009 +|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10113|(% colspan="2" style="width:506px" %)((( 1010 +* Unit: s. 1011 +* Range: 0 to 30 1012 +))) 933 933 |(% style="width:173px" %)HMI station number|(% style="width:122px" %)HSW10114|(% colspan="2" style="width:506px" %) 934 934 |(% style="width:173px" %)PLC station number|(% style="width:122px" %)HSW10115|(% colspan="2" style="width:506px" %) 935 935 |(% colspan="1" rowspan="11" style="width:102px" %)COM3|(% style="width:173px" %)Communication mode|(% style="width:122px" %)HSW10083|(% colspan="2" style="width:506px" %)((( ... ... @@ -959,19 +959,37 @@ 959 959 * =1: ODD 960 960 * =2: EVEN 961 961 ))) 962 -|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10088|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000 963 -|(% style="width:173px" %)receive timeout|(% style="width:122px" %)HSW10089|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000 964 -|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10090|(% colspan="2" style="width:506px" %)Unit: times. Range: 0~~100 965 -|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10091|(% colspan="2" style="width:506px" %)Unit: s. Range: 0~~30 1042 +|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10088|(% colspan="2" style="width:506px" %)((( 1043 +* Unit: ms. 1044 +* Range: 0 to 30000 1045 +))) 1046 +|(% style="width:173px" %)receive timeout|(% style="width:122px" %)HSW10089|(% colspan="2" style="width:506px" %)((( 1047 +* Unit: ms. 1048 +* Range: 0 to 30000 1049 +))) 1050 +|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10090|(% colspan="2" style="width:506px" %)((( 1051 +* Unit: times. 1052 +* Range: 0 to 100 1053 +))) 1054 +|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10091|(% colspan="2" style="width:506px" %)((( 1055 +* Unit: s. 1056 +* Range: 0 to 30 1057 +))) 966 966 |(% style="width:173px" %)HMI station number|(% style="width:122px" %)HSW10092|(% colspan="2" style="width:506px" %) 967 967 |(% style="width:173px" %)PLC station number|(% style="width:122px" %)HSW10093|(% colspan="2" style="width:506px" %) 968 968 |(% colspan="1" rowspan="2" style="width:102px" %)CAN port|(% style="width:173px" %)CAN1 baud rate|(% style="width:122px" %)HSW010116|(% style="width:299px" %)((( 969 -Unit: K, the baud rate must be an integer, for example, when the baud rate required is 250000, just enter 250. 1061 +Unit: K, the baud rate must be an integer. 1062 + 1063 +For example, when the baud rate required is 250000, just enter 250. 970 970 )))|(% colspan="1" rowspan="2" style="width:218px" %)**✎Note: **If baud rate has been modified,please wait 5 seconds,then restart the HMI to take effect. 971 -|(% style="width:173px" %)CAN2 baud rate|(% style="width:122px" %)HSW010117|(% style="width:299px" %)Unit: K, the baud rate must be an integer, for example, when the baud rate required is 250000, just enter 250. 1065 +|(% style="width:173px" %)CAN2 baud rate|(% style="width:122px" %)HSW010117|(% style="width:299px" %)((( 1066 +Unit: K, the baud rate must be an integer. 972 972 973 -== **Ethernet communication configuration** == 1068 +For example, when the baud rate required is 250000, just enter 250. 1069 +))) 974 974 1071 +== Ethernet communication configuration == 1072 + 975 975 (% class="table-bordered" %) 976 976 |=(% style="width: 40px;" %)**No.**|=(% style="width: 295px;" %)**Function**|=(% style="width: 220px;" %)**Address**|=(% style="width: 336px;" %)**Description** 977 977 |(% rowspan="7" style="width:40px" %)1|(% colspan="1" rowspan="7" style="width:295px" %)Ethernet parameter configuration for communication number 1 in list. Configure those addresses according to connected device. After configuration, wait for 5 seconds and restart the HMI.|(% style="width:220px" %)HSW11004|(% style="width:336px" %)Device IP address high word 1 ... ... @@ -1008,7 +1008,7 @@ 1008 1008 **✎Note:** The number of Ethernet connections supported by different HMI series varies. 1009 1009 ))) 1010 1010 1011 -== **Communication control**==1109 +== Communication control == 1012 1012 1013 1013 (% class="table-bordered" %) 1014 1014 |=(% style="width: 135px;" %)**Communication No.**|=(% style="width: 102px;" %)**Station No.**|=(% style="width: 185px;" %)**Control bit**|=(% style="width: 191px;" %)**Communication lamp**|=(% style="width: 271px;" %)**Description**