Changes for page 13 HMI Internal Registers
Last modified by Jett on 2025/04/28 16:07
From version 4.3
edited by Stone Wu
on 2022/08/06 14:11
on 2022/08/06 14:11
Change comment:
There is no comment for this version
To version 11.1
edited by Theodore Xu
on 2022/12/16 10:14
on 2022/12/16 10:14
Change comment:
There is no comment for this version
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Stone1 +XWiki.AiXia - Content
-
... ... @@ -4,11 +4,11 @@ 4 4 5 5 *HSW, HDW, HUW, HAW are word address, HSX, HDX, HUX, HAX are bit address. 6 6 7 - 1.**System data area (HSW): **A special register defined by the system.8 - 1.**Data storage area (HDW/HDX): **Users store user data.9 - 1.**System data area (HUW): **A special register defined by the system.10 - 1.**System Data (HAW)**: System register used for power-off save.11 - 1.**Recipe index area (RPW): **System register used for recipe index.7 +* **System data area (HSW): **A special register defined by the system. 8 +* **Data storage area (HDW/HDX): **Users store user data. 9 +* **System data area (HUW): **A special register defined by the system. 10 +* **System Data (HAW)**: System register used for power-off save. 11 +* **Recipe index area (RPW): **System register used for recipe index. 12 12 13 13 HMI internal registers are divided into bit address and word address, which can be accessed in two ways (take HDW as an example). 14 14 ... ... @@ -643,6 +643,27 @@ 643 643 * =1: download firmware 644 644 * =2: enter the background 645 645 ))) 646 +|=(% style="width: 160px;" %)HSW1865|(% style="width:282px" %)Priority connection to the cloud|(% style="width:452px" %)((( 647 +* =0: priority Ethernet 648 +* =1: priority WLAN 649 +* =2: priority 4G 650 +))) 651 +|=(% style="width: 160px;" %)HSW1866|(% style="width:282px" %)Delete the LUa extension module file|(% style="width:452px" %)((( 652 +* =0: delete; 653 +* = Others: do not delete 654 +))) 655 +|=(% style="width: 160px;" %)HSW1867|(% style="width:282px" %)Reset mode|(% style="width:452px" %)((( 656 +Monitor address is set during reset of reset switch, whether to cancel reset, 657 + 658 +* = 0: yes (default); 659 +* = 1: no 660 +))) 661 +|=(% style="width: 160px;" %)HSW1868|(% style="width:282px" %)Double-click or long press the record type table mode|(% style="width:452px" %)((( 662 +Controls whether the button pops up when double-clicking or long pressing on record type table object 663 + 664 +* = 0: yes (default); 665 +* = 1: no 666 +))) 646 646 |=(% style="width: 160px;" %)HSW10000~~19999|(% style="width:282px" %)Power-down storage area|(% style="width:452px" %)After restart, the data remains 647 647 |=(% style="width: 160px;" %)HSW10035|(% rowspan="13" style="width:282px" %)((( 648 648 **✎Note: **Only valid when the HMI is plugged into the Ethernet cable. ... ... @@ -757,10 +757,10 @@ 757 757 |=(% style="width: 160px;" %)HSW11760|(% style="width:282px" %)Screensaver countdown|(% style="width:452px" %)Display the countdown to enter the Screensaver, unit: second. 758 758 |=(% style="width: 160px;" %)HSW11761|(% style="width:282px" %)Screensaver screen number|(% style="width:452px" %)Set the screen number for Screensaver 759 759 760 -== **Serial port communication configuration**==781 +== Serial port communication configuration == 761 761 762 762 (% class="table-bordered" %) 763 -|=(% style="width: 102px;" %)Port|=(% style="width: 173px;" %)**Function**|=(% style="width: 122px;" %)**Address**|=(% colspan="2" style="width: 506px;" %)**Description** 784 +|=(% scope="row" style="width: 102px;" %)Port|=(% style="width: 173px;" %)**Function**|=(% style="width: 122px;" %)**Address**|=(% colspan="2" style="width: 506px;" %)**Description** 764 764 |(% colspan="1" rowspan="11" style="width:102px" %)COM1|(% style="width:173px" %)Communication mode|(% style="width:122px" %)HSW10061|(% colspan="2" style="width:506px" %)((( 765 765 * =0: RS232 766 766 * =1: RS485 ... ... @@ -790,10 +790,22 @@ 790 790 * =1: ODD 791 791 * =2: EVEN 792 792 ))) 793 -|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10066|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000 794 -|(% style="width:173px" %)reveive timeout|(% style="width:122px" %)HSW10067|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000 795 -|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10068|(% colspan="2" style="width:506px" %)Unit: times. Range: 0~~100 796 -|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10069|(% colspan="2" style="width:506px" %)Unit: s. Range: 0~~300 814 +|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10066|(% colspan="2" style="width:506px" %)((( 815 +* Unit: ms. 816 +* Range: 0 to 30000 817 +))) 818 +|(% style="width:173px" %)reveive timeout|(% style="width:122px" %)HSW10067|(% colspan="2" style="width:506px" %)((( 819 +* Unit: ms. 820 +* Range: 0 to 30000 821 +))) 822 +|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10068|(% colspan="2" style="width:506px" %)((( 823 +* Unit: times. 824 +* Range: 0 to 100 825 +))) 826 +|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10069|(% colspan="2" style="width:506px" %)((( 827 +* Unit: s. 828 +* Range: 0 to 300 829 +))) 797 797 |(% style="width:173px" %)HMI station number|(% style="width:122px" %)HSW10070|(% colspan="2" style="width:506px" %) 798 798 |(% style="width:173px" %)PLC station number|(% style="width:122px" %)HSW10071|(% colspan="2" style="width:506px" %) 799 799 |(% colspan="1" rowspan="11" style="width:102px" %)COM1-2|(% style="width:173px" %)Communication mode|(% style="width:122px" %)HSW10094|(% colspan="2" style="width:506px" %)((( ... ... @@ -826,10 +826,22 @@ 826 826 * =1: ODD 827 827 * =2: EVEN 828 828 ))) 829 -|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10099|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000 830 -|(% style="width:173px" %)receive timeout|(% style="width:122px" %)HSW10100|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000 831 -|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10101|(% colspan="2" style="width:506px" %)Unit: times. Range: 0~~100 832 -|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10102|(% colspan="2" style="width:506px" %)Unit: s. Range: 0~~30 862 +|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10099|(% colspan="2" style="width:506px" %)((( 863 +* Unit: ms. 864 +* Range: 0 to 30000 865 +))) 866 +|(% style="width:173px" %)receive timeout|(% style="width:122px" %)HSW10100|(% colspan="2" style="width:506px" %)((( 867 +* Unit: ms. 868 +* Range: 0 to 30000 869 +))) 870 +|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10101|(% colspan="2" style="width:506px" %)((( 871 +* Unit: times. 872 +* Range: 0 to 100 873 +))) 874 +|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10102|(% colspan="2" style="width:506px" %)((( 875 +* Unit: s. 876 +* Range: 0 to 30 877 +))) 833 833 |(% style="width:173px" %)HMI station number|(% style="width:122px" %)HSW10103|(% colspan="2" style="width:506px" %) 834 834 |(% style="width:173px" %)PLC station number|(% style="width:122px" %)HSW10104|(% colspan="2" style="width:506px" %) 835 835 |(% colspan="1" rowspan="11" style="width:102px" %)COM1-3|(% style="width:173px" %)Communication mode|(% style="width:122px" %)HSW10120|(% colspan="2" style="width:506px" %)((( ... ... @@ -862,10 +862,22 @@ 862 862 * =1: ODD 863 863 * =2: EVEN 864 864 ))) 865 -|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10125|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000 866 -|(% style="width:173px" %)receive timeout|(% style="width:122px" %)HSW10126|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000 867 -|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10127|(% colspan="2" style="width:506px" %)Unit: times. Range: 0~~100 868 -|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10128|(% colspan="2" style="width:506px" %)Unit: s. Range: 0~~30 910 +|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10125|(% colspan="2" style="width:506px" %)((( 911 +* Unit: ms. 912 +* Range: 0 to 30000 913 +))) 914 +|(% style="width:173px" %)receive timeout|(% style="width:122px" %)HSW10126|(% colspan="2" style="width:506px" %)((( 915 +* Unit: ms. 916 +* Range: 0 to 30000 917 +))) 918 +|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10127|(% colspan="2" style="width:506px" %)((( 919 +* Unit: times. 920 +* Range: 0 to 100 921 +))) 922 +|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10128|(% colspan="2" style="width:506px" %)((( 923 +* Unit: s. 924 +* Range: 0 to 30 925 +))) 869 869 |(% style="width:173px" %)HMI station number|(% style="width:122px" %)HSW10129|(% colspan="2" style="width:506px" %) 870 870 |(% style="width:173px" %)PLC station number|(% style="width:122px" %)HSW10130|(% colspan="2" style="width:506px" %) 871 871 |(% colspan="1" rowspan="11" style="width:102px" %)COM2|(% style="width:173px" %)Communication mode|(% style="width:122px" %)HSW10072|(% colspan="2" style="width:506px" %)((( ... ... @@ -896,10 +896,22 @@ 896 896 * =1: ODD 897 897 * =2: EVEN 898 898 ))) 899 -|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10077|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000 900 -|(% style="width:173px" %)receive timeout|(% style="width:122px" %)HSW10078|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000 901 -|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10079|(% colspan="2" style="width:506px" %)Unit: times. Range: 0~~100 902 -|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10080|(% colspan="2" style="width:506px" %)Unit: s. Range: 0~~30 956 +|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10077|(% colspan="2" style="width:506px" %)((( 957 +* Unit: ms. 958 +* Range: 0 to 30000 959 +))) 960 +|(% style="width:173px" %)receive timeout|(% style="width:122px" %)HSW10078|(% colspan="2" style="width:506px" %)((( 961 +* Unit: ms. 962 +* Range: 0 to 30000 963 +))) 964 +|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10079|(% colspan="2" style="width:506px" %)((( 965 +* Unit: times. 966 +* Range: 0 to 100 967 +))) 968 +|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10080|(% colspan="2" style="width:506px" %)((( 969 +* Unit: s. 970 +* Range: 0 to 30 971 +))) 903 903 |(% style="width:173px" %)HMI station number|(% style="width:122px" %)HSW10081|(% colspan="2" style="width:506px" %) 904 904 |(% style="width:173px" %)PLC station number|(% style="width:122px" %)HSW10082|(% colspan="2" style="width:506px" %) 905 905 |(% colspan="1" rowspan="11" style="width:102px" %)COM2-2|(% style="width:173px" %)Communication mode|(% style="width:122px" %)HSW10105|(% colspan="2" style="width:506px" %)((( ... ... @@ -930,10 +930,22 @@ 930 930 * =1: ODD 931 931 * =2: EVEN 932 932 ))) 933 -|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10110|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000 934 -|(% style="width:173px" %)receive timeout|(% style="width:122px" %)HSW10111|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000 935 -|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10112|(% colspan="2" style="width:506px" %)Unit: times. Range: 0~~100 936 -|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10113|(% colspan="2" style="width:506px" %)Unit: s. Range: 0~~30 1002 +|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10110|(% colspan="2" style="width:506px" %)((( 1003 +* Unit: ms. 1004 +* Range: 0 to 30000 1005 +))) 1006 +|(% style="width:173px" %)receive timeout|(% style="width:122px" %)HSW10111|(% colspan="2" style="width:506px" %)((( 1007 +* Unit: ms. 1008 +* Range: 0 to 30000 1009 +))) 1010 +|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10112|(% colspan="2" style="width:506px" %)((( 1011 +* Unit: times. 1012 +* Range: 0 to 100 1013 +))) 1014 +|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10113|(% colspan="2" style="width:506px" %)((( 1015 +* Unit: s. 1016 +* Range: 0 to 30 1017 +))) 937 937 |(% style="width:173px" %)HMI station number|(% style="width:122px" %)HSW10114|(% colspan="2" style="width:506px" %) 938 938 |(% style="width:173px" %)PLC station number|(% style="width:122px" %)HSW10115|(% colspan="2" style="width:506px" %) 939 939 |(% colspan="1" rowspan="11" style="width:102px" %)COM3|(% style="width:173px" %)Communication mode|(% style="width:122px" %)HSW10083|(% colspan="2" style="width:506px" %)((( ... ... @@ -963,29 +963,48 @@ 963 963 * =1: ODD 964 964 * =2: EVEN 965 965 ))) 966 -|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10088|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000 967 -|(% style="width:173px" %)receive timeout|(% style="width:122px" %)HSW10089|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000 968 -|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10090|(% colspan="2" style="width:506px" %)Unit: times. Range: 0~~100 969 -|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10091|(% colspan="2" style="width:506px" %)Unit: s. Range: 0~~30 1047 +|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10088|(% colspan="2" style="width:506px" %)((( 1048 +* Unit: ms. 1049 +* Range: 0 to 30000 1050 +))) 1051 +|(% style="width:173px" %)receive timeout|(% style="width:122px" %)HSW10089|(% colspan="2" style="width:506px" %)((( 1052 +* Unit: ms. 1053 +* Range: 0 to 30000 1054 +))) 1055 +|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10090|(% colspan="2" style="width:506px" %)((( 1056 +* Unit: times. 1057 +* Range: 0 to 100 1058 +))) 1059 +|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10091|(% colspan="2" style="width:506px" %)((( 1060 +* Unit: s. 1061 +* Range: 0 to 30 1062 +))) 970 970 |(% style="width:173px" %)HMI station number|(% style="width:122px" %)HSW10092|(% colspan="2" style="width:506px" %) 971 971 |(% style="width:173px" %)PLC station number|(% style="width:122px" %)HSW10093|(% colspan="2" style="width:506px" %) 972 972 |(% colspan="1" rowspan="2" style="width:102px" %)CAN port|(% style="width:173px" %)CAN1 baud rate|(% style="width:122px" %)HSW010116|(% style="width:299px" %)((( 973 -Unit: K, the baud rate must be an integer, for example, when the baud rate required is 250000, just enter 250. 1066 +Unit: K, the baud rate must be an integer. 1067 + 1068 +For example, when the baud rate required is 250000, just enter 250. 974 974 )))|(% colspan="1" rowspan="2" style="width:218px" %)**✎Note: **If baud rate has been modified,please wait 5 seconds,then restart the HMI to take effect. 975 -|(% style="width:173px" %)CAN2 baud rate|(% style="width:122px" %)HSW010117|(% style="width:299px" %)Unit: K, the baud rate must be an integer, for example, when the baud rate required is 250000, just enter 250. 1070 +|(% style="width:173px" %)CAN2 baud rate|(% style="width:122px" %)HSW010117|(% style="width:299px" %)((( 1071 +Unit: K, the baud rate must be an integer. 976 976 977 -== **Ethernet communication configuration** == 1073 +For example, when the baud rate required is 250000, just enter 250. 1074 +))) 978 978 1076 +== Ethernet communication configuration == 1077 + 979 979 (% class="table-bordered" %) 980 -| =(% style="width:;" %)**No.**|=(% style="width:;" %)**Function**|=(% style="width:;" %)**Address**|=(% style="width:;" %)**Description**1079 +|(% style="width:40px" %)**No.**|(% style="width:295px" %)**Function**|(% style="width:220px" %)**Address**|(% style="width:336px" %)**Description** 981 981 |(% rowspan="7" style="width:40px" %)1|(% colspan="1" rowspan="7" style="width:295px" %)Ethernet parameter configuration for communication number 1 in list. Configure those addresses according to connected device. After configuration, wait for 5 seconds and restart the HMI.|(% style="width:220px" %)HSW11004|(% style="width:336px" %)Device IP address high word 1 982 982 |(% style="width:220px" %)HSW11005|(% style="width:336px" %)Device IP address high word 2 983 983 |(% style="width:220px" %)HSW11006|(% style="width:336px" %)Device IP address high word 3 984 984 |(% style="width:220px" %)HSW11007|(% style="width:336px" %)Device IP address high word 4 985 985 |(% style="width:220px" %)HSW11008|(% style="width:336px" %)Device Port number 986 -|(% style="width:220px" %)HSW11009|=(% style="width: 336px;" %)((( 987 -* =2 TCP 988 -* =3 UDP 1085 +|(% style="width:220px" %)HSW11009|(% style="width:336px" %)((( 1086 +~=2 TCP 1087 + 1088 +~=3 UDP 989 989 ))) 990 990 |(% style="width:220px" %)HSW11010|(% style="width:336px" %)Reserved 991 991 |(% rowspan="7" style="width:40px" %)2|(% colspan="1" rowspan="7" style="width:295px" %)Ethernet parameter configuration for communication number 2 in list. Configure those addresses according to connected device. After configuration, wait for 5 seconds and restart the HMI.|(% style="width:220px" %)HSW11011|(% style="width:336px" %)Device IP address high word 1 ... ... @@ -993,9 +993,10 @@ 993 993 |(% style="width:220px" %)HSW11013|(% style="width:336px" %)Device IP address high word 3 994 994 |(% style="width:220px" %)HSW11014|(% style="width:336px" %)Device IP address high word 4 995 995 |(% style="width:220px" %)HSW11015|(% style="width:336px" %)Device Port number 996 -|(% style="width:220px" %)HSW11016|=(% style="width: 336px;" %)((( 997 -* =2 TCP 998 -* =3 UDP 1096 +|(% style="width:220px" %)HSW11016|(% style="width:336px" %)((( 1097 +~=2 TCP 1098 + 1099 +~=3 UDP 999 999 ))) 1000 1000 |(% style="width:220px" %)HSW11017|(% style="width:336px" %)Reserved 1001 1001 |(% style="width:40px" %)…|(% style="width:295px" %) |(% style="width:220px" %)…|(% style="width:336px" %)… ... ... @@ -1004,7 +1004,11 @@ 1004 1004 |(% style="width:220px" %)HSW11223|(% style="width:336px" %)Device IP address high word 3 1005 1005 |(% style="width:220px" %)HSW11224|(% style="width:336px" %)Device IP address high word 4 1006 1006 |(% style="width:220px" %)HSW11225|(% style="width:336px" %)Device Port number 1007 -|(% style="width:220px" %)HSW11226|=(% style="width: 336px;" %)2 TCP; =3 UDP 1108 +|(% style="width:220px" %)HSW11226|(% style="width:336px" %)((( 1109 +~=2 TCP; 1110 + 1111 +~=3 UDP 1112 +))) 1008 1008 |(% style="width:220px" %)HSW11227|(% style="width:336px" %)Reserved 1009 1009 1010 1010 (% class="box infomessage" %) ... ... @@ -1012,7 +1012,7 @@ 1012 1012 **✎Note:** The number of Ethernet connections supported by different HMI series varies. 1013 1013 ))) 1014 1014 1015 -== **Communication control**==1120 +== Communication control == 1016 1016 1017 1017 (% class="table-bordered" %) 1018 1018 |=(% style="width: 135px;" %)**Communication No.**|=(% style="width: 102px;" %)**Station No.**|=(% style="width: 185px;" %)**Control bit**|=(% style="width: 191px;" %)**Communication lamp**|=(% style="width: 271px;" %)**Description**