Changes for page 13 HMI Internal Registers
Last modified by Jett on 2025/04/28 16:07
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Stone1 +XWiki.Bob - Content
-
... ... @@ -4,11 +4,11 @@ 4 4 5 5 *HSW, HDW, HUW, HAW are word address, HSX, HDX, HUX, HAX are bit address. 6 6 7 - 1.**System data area (HSW): **A special register defined by the system.8 - 1.**Data storage area (HDW/HDX): **Users store user data.9 - 1.**System data area (HUW): **A special register defined by the system.10 - 1.**System Data (HAW)**: System register used for power-off save.11 - 1.**Recipe index area (RPW): **System register used for recipe index.7 +* **System data area (HSW): **A special register defined by the system. 8 +* **Data storage area (HDW/HDX): **Users store user data. 9 +* **System data area (HUW): **A special register defined by the system. 10 +* **System Data (HAW)**: System register used for power-off save. 11 +* **Recipe index area (RPW): **System register used for recipe index. 12 12 13 13 HMI internal registers are divided into bit address and word address, which can be accessed in two ways (take HDW as an example). 14 14 ... ... @@ -618,6 +618,174 @@ 618 618 * =1: Server connection is OK 619 619 ))) 620 620 |=(% style="width: 160px;" %)HSW1761|(% style="width:282px" %)Display 4G network signal strength|(% style="width:452px" %)Signal strength: 0~~31. The greater the value ,the signal is stronger 621 +|=(% style="width: 160px;" %)((( 622 +HSW1762 623 +)))|(% colspan="1" rowspan="13" style="width:282px" %)((( 624 +Note: Valid when Ethernet2 of HMI is plugged into the network cable. 625 +①、When the Ethernet setting is enabled in the project parameters, this register displays the set value. 626 +②. When the Ethernet setting is not enabled in the engineering parameters, the register displays the Ethernet IP automatically acquired by the HMI. 627 +③. When the HMI is not plugged into the network cable, the register will show 0 whether the engineering parameters are set or not. 628 +④.IP related registers can be read and written (only static IP mode can be written). 629 +)))|(% style="width:452px" %)((( 630 +Ethernet2 Local IP address high byte 1 631 +))) 632 +|=(% style="width: 160px;" %)((( 633 +HSW1763 634 +)))|(% style="width:452px" %)((( 635 +Ethernet2 Local IP address high byte 2 636 +))) 637 +|=(% style="width: 160px;" %)((( 638 +HSW1764 639 +)))|(% style="width:452px" %)((( 640 +Ethernet2 Local IP address high byte 3 641 +))) 642 +|=(% style="width: 160px;" %)((( 643 +HSW1765 644 +)))|(% style="width:452px" %)((( 645 +Ethernet2 Local IP address high byte 4 646 +))) 647 +|=(% style="width: 160px;" %)((( 648 +HSW1766 649 +)))|(% style="width:452px" %)((( 650 +Ethernet2 Local mask IP address high byte 1 651 +))) 652 +|=(% style="width: 160px;" %)((( 653 +HSW1767 654 +)))|(% style="width:452px" %)((( 655 +Ethernet2 Local mask IP address high byte 2 656 +))) 657 +|=(% style="width: 160px;" %)((( 658 +HSW1768 659 +)))|(% style="width:452px" %)Ethernet2 Local mask IP address high byte 3 660 +|=(% style="width: 160px;" %)HSW1769|(% style="width:452px" %)Ethernet2 Local mask IP address high byte 4 661 +|=(% style="width: 160px;" %)((( 662 +HSW1770 663 +)))|(% style="width:452px" %)((( 664 +Ethernet2 Local gateway IP address high byte 1 665 +))) 666 +|=(% style="width: 160px;" %)((( 667 +HSW1771 668 +)))|(% style="width:452px" %)((( 669 +Ethernet2 Local gateway IP address high byte 2 670 +))) 671 +|=(% style="width: 160px;" %)((( 672 +HSW1772 673 +)))|(% style="width:452px" %)((( 674 +Ethernet2 Local gateway IP address high byte 3 675 +))) 676 +|=(% style="width: 160px;" %)((( 677 +HSW1773 678 +)))|(% style="width:452px" %)((( 679 +Ethernet2 Local gateway IP address high byte 4 680 +))) 681 +|=(% style="width: 160px;" %)((( 682 +HSW1774 683 +)))|(% style="width:452px" %)((( 684 +Ethernet2 Local Port Address 685 +))) 686 +|=(% style="width: 160px;" %)((( 687 +HSW1775 688 +)))|(% colspan="1" rowspan="6" style="width:282px" %)((( 689 +①Display the MAC code of Ethernet2 NIC 690 + 691 +(hexadecimal display) 692 + 693 +②Read-only mode, not modifiable 694 +)))|(% style="width:452px" %)((( 695 +Ethernet2 Local MAC code high byte 1 696 +))) 697 +|=(% style="width: 160px;" %)((( 698 +HSW1776 699 +)))|(% style="width:452px" %)((( 700 +Ethernet2 Local MAC code high byte 2 701 +))) 702 +|=(% style="width: 160px;" %)((( 703 +HSW1777 704 +)))|(% style="width:452px" %)((( 705 +Ethernet2 Local MAC code high byte 3 706 +))) 707 +|=(% style="width: 160px;" %)((( 708 +HSW1778 709 +)))|(% style="width:452px" %)((( 710 +Ethernet2 Local MAC code high byte 4 711 +))) 712 +|=(% style="width: 160px;" %)((( 713 +HSW1779 714 +)))|(% style="width:452px" %)((( 715 +Ethernet2 Local MAC code high byte 5 716 +))) 717 +|=(% style="width: 160px;" %)((( 718 +HSW1780 719 +)))|(% style="width:452px" %)((( 720 +Ethernet2 Local MAC code high byte 6 721 +))) 722 +|=(% style="width: 160px;" %)((( 723 +HSW1781 724 +)))|(% colspan="1" rowspan="8" style="width:282px" %)((( 725 +①Display and modify DNS1 and DNS2 of Ethernet2 726 + 727 +②Related registers can be read and written mode (only static IP mode can be written) 728 +)))|(% style="width:452px" %)((( 729 +Ethernet2 Local DNS1 address high byte 1 730 +))) 731 +|=(% style="width: 160px;" %)((( 732 +HSW1782 733 +)))|(% style="width:452px" %)((( 734 +Ethernet2 Local DNS1 address high byte 2 735 +))) 736 +|=(% style="width: 160px;" %)((( 737 +HSW1783 738 +)))|(% style="width:452px" %)((( 739 +Ethernet2 Local DNS1 address high byte 3 740 +))) 741 +|=(% style="width: 160px;" %)((( 742 +HSW1784 743 +)))|(% style="width:452px" %)((( 744 +Ethernet2 Local DNS1 address high byte 4 745 +))) 746 +|=(% style="width: 160px;" %)((( 747 +HSW1785 748 +)))|(% style="width:452px" %)((( 749 +Ethernet2 Local DNS2 address high byte 1 750 +))) 751 +|=(% style="width: 160px;" %)((( 752 +HSW1786 753 +)))|(% style="width:452px" %)((( 754 +Ethernet2 Local DNS2 address high byte 2 755 +))) 756 +|=(% style="width: 160px;" %)((( 757 +HSW1787 758 +)))|(% style="width:452px" %)((( 759 +Ethernet2 Local DNS2 address high byte 3 760 +))) 761 +|=(% style="width: 160px;" %)((( 762 +HSW1788 763 +)))|(% style="width:452px" %)((( 764 +Ethernet2 Local DNS2 address high byte 4 765 +))) 766 +|=(% style="width: 160px;" %)((( 767 +HSW1789 768 +)))|(% colspan="1" style="width:282px" %)((( 769 +Display or set the dynamic or static IP mode of Ethernet2 770 +)))|(% style="width:452px" %)((( 771 +HSX1789.0 = 0, Static IP mode 772 + 773 +HSX1789.0 = 1, dynamic IP mode 774 +))) 775 +|=(% style="width: 160px;" %)((( 776 +HSW1790 777 +)))|(% colspan="1" style="width:282px" %)((( 778 +Confirm Ethernet2 IP, subnet mask, gateway, DNS1, DNS2, and dynamic static IP settings 779 +)))|(% style="width:452px" %)((( 780 +~= 1, confirm the setting (i.e., after modifying IP-related information, set this address to 1, representing confirmation of the modification, after which it will be reset to 0) 781 +))) 782 +|=(% style="width: 160px;" %)((( 783 +HSW1791 784 +)))|(% colspan="1" style="width:282px" %)((( 785 +Network status of the Ethernet2 connection server 786 +)))|(% style="width:452px" %)((( 787 +~= 0, connection to the server is abnormal = 1, connection to the server is normal 788 +))) 621 621 |=(% style="width: 160px;" %)HSW1852|(% style="width:282px" %)Control the interval in two consecutive clicks|(% style="width:452px" %)Limit range: 1~~500ms. The default is 100 ms. 622 622 |=(% style="width: 160px;" %)HSW1853|(% style="width:282px" %)File format for exporting data records to USB flash drive or SD card|(% style="width:452px" %)((( 623 623 * =0: db database ... ... @@ -643,14 +643,87 @@ 643 643 * =1: download firmware 644 644 * =2: enter the background 645 645 ))) 814 +|=(% style="width: 160px;" %)HSW1865|(% style="width:282px" %)Priority connection to the cloud|(% style="width:452px" %)((( 815 +* =0: priority Ethernet 816 +* =1: priority WLAN 817 +* =2: priority 4G 818 +))) 819 +|=(% style="width: 160px;" %)HSW1866|(% style="width:282px" %)Delete the LUa extension module file|(% style="width:452px" %)((( 820 +* =0: delete; 821 +* = Others: do not delete 822 +))) 823 +|=(% style="width: 160px;" %)HSW1867|(% style="width:282px" %)Reset mode|(% style="width:452px" %)((( 824 +Monitor address is set during reset of reset switch, whether to cancel reset, 825 + 826 +* = 0: yes (default); 827 +* = 1: no 828 +))) 829 +|=(% style="width: 160px;" %)HSW1868|(% style="width:282px" %)Double-click or long press the record type table mode|(% style="width:452px" %)((( 830 +Controls whether the button pops up when double-clicking or long pressing on record type table object 831 + 832 +* = 0: yes (default); 833 +* = 1: no 834 +))) 835 +|=(% style="width: 160px;" %)((( 836 +HSW1869 837 +)))|(% style="width:282px" %)((( 838 +Dynamic screensaver countdown 839 +)))|(% style="width:452px" %)((( 840 +Countdown to enter dynamic screensaver effect, unit (S) 841 +))) 842 +|=(% style="width: 160px;" %)((( 843 +HSW1870 844 +)))|(% style="width:282px" %)((( 845 +Display or set the dynamic or static IP mode of Ethernet1 846 +)))|(% style="width:452px" %)((( 847 +HSX1870.0 = 0, Static IP mode 848 + 849 +HSX1870.0 = 1, dynamic IP mode 850 +))) 851 +|=(% style="width: 160px;" %)((( 852 +HSW1871 853 +)))|(% style="width:282px" %)((( 854 +Confirm the IP, subnet mask, gateway, DNS1, DNS2, and dynamic static IP settings for Ethernet1 855 +)))|(% style="width:452px" %)((( 856 +~= 1, confirm the setting (i.e., after modifying IP-related information, set this address to 1, representing confirmation of the modification, after which it will be reset to 0) 857 +))) 858 +|=(% style="width: 160px;" %)((( 859 +HSW1872 860 +)))|(% colspan="1" rowspan="8" style="width:282px" %)((( 861 +①Display and modify DNS1 and DNS2 of Ethernet1 862 + 863 +②Related registers can be read and written mode (only static IP mode can be written) 864 +)))|(% style="width:452px" %)((( 865 +Ethernet1 Local DNS1 address high byte 1 866 +))) 867 +|=(% style="width: 160px;" %)((( 868 +HSW1873 869 +)))|(% style="width:452px" %)Ethernet1 Local DNS1 address high byte 2 870 +|=(% style="width: 160px;" %)((( 871 +HSW1874 872 +)))|(% style="width:452px" %)Ethernet1 Local DNS1 address high byte 3 873 +|=(% style="width: 160px;" %)((( 874 +HSW1875 875 +)))|(% style="width:452px" %)Ethernet1 Local DNS1 address high byte 4 876 +|=(% style="width: 160px;" %)((( 877 +HSW1876 878 +)))|(% style="width:452px" %)Ethernet1 Local DNS2 address high byte 1 879 +|=(% style="width: 160px;" %)((( 880 +HSW1877 881 +)))|(% style="width:452px" %)Ethernet1 Local DNS2 address high byte 2 882 +|=(% style="width: 160px;" %)((( 883 +HSW1878 884 +)))|(% style="width:452px" %)Ethernet1 Local DNS2 address high byte 3 885 +|=(% style="width: 160px;" %)((( 886 +HSW1879 887 +)))|(% style="width:452px" %)Ethernet1 Local DNS2 address high byte 4 646 646 |=(% style="width: 160px;" %)HSW10000~~19999|(% style="width:282px" %)Power-down storage area|(% style="width:452px" %)After restart, the data remains 647 647 |=(% style="width: 160px;" %)HSW10035|(% rowspan="13" style="width:282px" %)((( 648 -**✎Note: **Only valid when the HMI is plugged into the Ethernet cable. 649 - 650 -1. If Ethernet settings is enabled in project parameters, this register displays the set value. 651 -1. If Ethernet settings is not enabled in project parameters, IP would automatically obtained IP. 652 -1. If HMI is not connected to the network, the register is displayed as 0 whether the engineering parameters are set. 653 -1. 4. All IP registers of HMI are read-only. 890 +Note: Valid when Ethernet1 of HMI is plugged into the network cable. 891 +①、When the Ethernet setting is enabled in the project parameters, this register displays the set value. 892 +②. When the Ethernet setting is not enabled in the engineering parameters, the register displays the Ethernet IP automatically acquired by the HMI. 893 +③. When the HMI is not plugged into the network cable, the register will show 0 whether the engineering parameters are set or not. 894 +④.IP related registers can be read and written (only static IP mode can be written). 654 654 )))|(% style="width:452px" %)Local IP address high byte 1 655 655 |=(% style="width: 160px;" %)HSW10036|(% style="width:452px" %)Local IP address high byte 2 656 656 |=(% style="width: 160px;" %)HSW10037|(% style="width:452px" %)Local IP address high byte 3 ... ... @@ -665,9 +665,11 @@ 665 665 |=(% style="width: 160px;" %)HSW10046|(% style="width:452px" %)Local gateway address high byte 4 666 666 |=(% style="width: 160px;" %)HSW10047|(% style="width:452px" %)Local port address 667 667 |=(% style="width: 160px;" %)HSW10048|(% rowspan="6" style="width:282px" %)((( 668 -Display sthe MAC code of thecurrent networkcard909 +①Display the MAC code of Ethernet1 NIC 669 669 670 -(Hexadecimal display) 911 +(hexadecimal display) 912 + 913 +②Read-only mode, not modifiable 671 671 )))|(% style="width:452px" %)Local MAC code high word 1 672 672 |=(% style="width: 160px;" %)HSW10049|(% style="width:452px" %)Local MAC code high word 2 673 673 |=(% style="width: 160px;" %)HSW10050|(% style="width:452px" %)Local MAC code high word 3 ... ... @@ -756,11 +756,32 @@ 756 756 ))) 757 757 |=(% style="width: 160px;" %)HSW11760|(% style="width:282px" %)Screensaver countdown|(% style="width:452px" %)Display the countdown to enter the Screensaver, unit: second. 758 758 |=(% style="width: 160px;" %)HSW11761|(% style="width:282px" %)Screensaver screen number|(% style="width:452px" %)Set the screen number for Screensaver 1002 +|=(% style="width: 160px;" %)((( 1003 +HSW11762 1004 +)))|(% style="width:282px" %)((( 1005 +Dynamic screensaver control address 1006 +)))|(% style="width:452px" %)((( 1007 +HSX11762.0: =0, initialize with project configuration; =1, initialize with special register configuration; HSX11762.1: =0, disable dynamic screensaver; =1, enable dynamic screensaver 1008 +))) 1009 +|=(% style="width: 160px;" %)((( 1010 +HSW11763 1011 +)))|(% style="width:282px" %)((( 1012 +Waiting time to enter the dynamic screensaver 1013 +)))|(% style="width:452px" %)((( 1014 +Waiting time when the screen is not operated, range 1~~720 minutes 1015 +))) 1016 +|=(% style="width: 160px;" %)((( 1017 +HSW11764 1018 +)))|(% style="width:282px" %)((( 1019 +Animated screensaver animation type 1020 +)))|(% style="width:452px" %)((( 1021 +~=0:lattice,=1:shutter,=2:bubble 1022 +))) 759 759 760 -== **Serial port communication configuration**==1024 +== Serial port communication configuration == 761 761 762 762 (% class="table-bordered" %) 763 -|=(% style="width: 102px;" %)Port|=(% style="width: 173px;" %)**Function**|=(% style="width: 122px;" %)**Address**|=(% colspan="2" style="width: 506px;" %)**Description** 1027 +|=(% scope="row" style="width: 102px;" %)Port|=(% style="width: 173px;" %)**Function**|=(% style="width: 122px;" %)**Address**|=(% colspan="2" style="width: 506px;" %)**Description** 764 764 |(% colspan="1" rowspan="11" style="width:102px" %)COM1|(% style="width:173px" %)Communication mode|(% style="width:122px" %)HSW10061|(% colspan="2" style="width:506px" %)((( 765 765 * =0: RS232 766 766 * =1: RS485 ... ... @@ -790,10 +790,22 @@ 790 790 * =1: ODD 791 791 * =2: EVEN 792 792 ))) 793 -|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10066|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000 794 -|(% style="width:173px" %)reveive timeout|(% style="width:122px" %)HSW10067|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000 795 -|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10068|(% colspan="2" style="width:506px" %)Unit: times. Range: 0~~100 796 -|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10069|(% colspan="2" style="width:506px" %)Unit: s. Range: 0~~300 1057 +|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10066|(% colspan="2" style="width:506px" %)((( 1058 +* Unit: ms. 1059 +* Range: 0 to 30000 1060 +))) 1061 +|(% style="width:173px" %)reveive timeout|(% style="width:122px" %)HSW10067|(% colspan="2" style="width:506px" %)((( 1062 +* Unit: ms. 1063 +* Range: 0 to 30000 1064 +))) 1065 +|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10068|(% colspan="2" style="width:506px" %)((( 1066 +* Unit: times. 1067 +* Range: 0 to 100 1068 +))) 1069 +|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10069|(% colspan="2" style="width:506px" %)((( 1070 +* Unit: s. 1071 +* Range: 0 to 300 1072 +))) 797 797 |(% style="width:173px" %)HMI station number|(% style="width:122px" %)HSW10070|(% colspan="2" style="width:506px" %) 798 798 |(% style="width:173px" %)PLC station number|(% style="width:122px" %)HSW10071|(% colspan="2" style="width:506px" %) 799 799 |(% colspan="1" rowspan="11" style="width:102px" %)COM1-2|(% style="width:173px" %)Communication mode|(% style="width:122px" %)HSW10094|(% colspan="2" style="width:506px" %)((( ... ... @@ -826,10 +826,22 @@ 826 826 * =1: ODD 827 827 * =2: EVEN 828 828 ))) 829 -|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10099|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000 830 -|(% style="width:173px" %)receive timeout|(% style="width:122px" %)HSW10100|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000 831 -|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10101|(% colspan="2" style="width:506px" %)Unit: times. Range: 0~~100 832 -|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10102|(% colspan="2" style="width:506px" %)Unit: s. Range: 0~~30 1105 +|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10099|(% colspan="2" style="width:506px" %)((( 1106 +* Unit: ms. 1107 +* Range: 0 to 30000 1108 +))) 1109 +|(% style="width:173px" %)receive timeout|(% style="width:122px" %)HSW10100|(% colspan="2" style="width:506px" %)((( 1110 +* Unit: ms. 1111 +* Range: 0 to 30000 1112 +))) 1113 +|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10101|(% colspan="2" style="width:506px" %)((( 1114 +* Unit: times. 1115 +* Range: 0 to 100 1116 +))) 1117 +|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10102|(% colspan="2" style="width:506px" %)((( 1118 +* Unit: s. 1119 +* Range: 0 to 30 1120 +))) 833 833 |(% style="width:173px" %)HMI station number|(% style="width:122px" %)HSW10103|(% colspan="2" style="width:506px" %) 834 834 |(% style="width:173px" %)PLC station number|(% style="width:122px" %)HSW10104|(% colspan="2" style="width:506px" %) 835 835 |(% colspan="1" rowspan="11" style="width:102px" %)COM1-3|(% style="width:173px" %)Communication mode|(% style="width:122px" %)HSW10120|(% colspan="2" style="width:506px" %)((( ... ... @@ -862,10 +862,22 @@ 862 862 * =1: ODD 863 863 * =2: EVEN 864 864 ))) 865 -|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10125|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000 866 -|(% style="width:173px" %)receive timeout|(% style="width:122px" %)HSW10126|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000 867 -|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10127|(% colspan="2" style="width:506px" %)Unit: times. Range: 0~~100 868 -|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10128|(% colspan="2" style="width:506px" %)Unit: s. Range: 0~~30 1153 +|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10125|(% colspan="2" style="width:506px" %)((( 1154 +* Unit: ms. 1155 +* Range: 0 to 30000 1156 +))) 1157 +|(% style="width:173px" %)receive timeout|(% style="width:122px" %)HSW10126|(% colspan="2" style="width:506px" %)((( 1158 +* Unit: ms. 1159 +* Range: 0 to 30000 1160 +))) 1161 +|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10127|(% colspan="2" style="width:506px" %)((( 1162 +* Unit: times. 1163 +* Range: 0 to 100 1164 +))) 1165 +|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10128|(% colspan="2" style="width:506px" %)((( 1166 +* Unit: s. 1167 +* Range: 0 to 30 1168 +))) 869 869 |(% style="width:173px" %)HMI station number|(% style="width:122px" %)HSW10129|(% colspan="2" style="width:506px" %) 870 870 |(% style="width:173px" %)PLC station number|(% style="width:122px" %)HSW10130|(% colspan="2" style="width:506px" %) 871 871 |(% colspan="1" rowspan="11" style="width:102px" %)COM2|(% style="width:173px" %)Communication mode|(% style="width:122px" %)HSW10072|(% colspan="2" style="width:506px" %)((( ... ... @@ -896,10 +896,22 @@ 896 896 * =1: ODD 897 897 * =2: EVEN 898 898 ))) 899 -|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10077|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000 900 -|(% style="width:173px" %)receive timeout|(% style="width:122px" %)HSW10078|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000 901 -|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10079|(% colspan="2" style="width:506px" %)Unit: times. Range: 0~~100 902 -|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10080|(% colspan="2" style="width:506px" %)Unit: s. Range: 0~~30 1199 +|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10077|(% colspan="2" style="width:506px" %)((( 1200 +* Unit: ms. 1201 +* Range: 0 to 30000 1202 +))) 1203 +|(% style="width:173px" %)receive timeout|(% style="width:122px" %)HSW10078|(% colspan="2" style="width:506px" %)((( 1204 +* Unit: ms. 1205 +* Range: 0 to 30000 1206 +))) 1207 +|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10079|(% colspan="2" style="width:506px" %)((( 1208 +* Unit: times. 1209 +* Range: 0 to 100 1210 +))) 1211 +|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10080|(% colspan="2" style="width:506px" %)((( 1212 +* Unit: s. 1213 +* Range: 0 to 30 1214 +))) 903 903 |(% style="width:173px" %)HMI station number|(% style="width:122px" %)HSW10081|(% colspan="2" style="width:506px" %) 904 904 |(% style="width:173px" %)PLC station number|(% style="width:122px" %)HSW10082|(% colspan="2" style="width:506px" %) 905 905 |(% colspan="1" rowspan="11" style="width:102px" %)COM2-2|(% style="width:173px" %)Communication mode|(% style="width:122px" %)HSW10105|(% colspan="2" style="width:506px" %)((( ... ... @@ -930,10 +930,22 @@ 930 930 * =1: ODD 931 931 * =2: EVEN 932 932 ))) 933 -|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10110|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000 934 -|(% style="width:173px" %)receive timeout|(% style="width:122px" %)HSW10111|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000 935 -|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10112|(% colspan="2" style="width:506px" %)Unit: times. Range: 0~~100 936 -|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10113|(% colspan="2" style="width:506px" %)Unit: s. Range: 0~~30 1245 +|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10110|(% colspan="2" style="width:506px" %)((( 1246 +* Unit: ms. 1247 +* Range: 0 to 30000 1248 +))) 1249 +|(% style="width:173px" %)receive timeout|(% style="width:122px" %)HSW10111|(% colspan="2" style="width:506px" %)((( 1250 +* Unit: ms. 1251 +* Range: 0 to 30000 1252 +))) 1253 +|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10112|(% colspan="2" style="width:506px" %)((( 1254 +* Unit: times. 1255 +* Range: 0 to 100 1256 +))) 1257 +|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10113|(% colspan="2" style="width:506px" %)((( 1258 +* Unit: s. 1259 +* Range: 0 to 30 1260 +))) 937 937 |(% style="width:173px" %)HMI station number|(% style="width:122px" %)HSW10114|(% colspan="2" style="width:506px" %) 938 938 |(% style="width:173px" %)PLC station number|(% style="width:122px" %)HSW10115|(% colspan="2" style="width:506px" %) 939 939 |(% colspan="1" rowspan="11" style="width:102px" %)COM3|(% style="width:173px" %)Communication mode|(% style="width:122px" %)HSW10083|(% colspan="2" style="width:506px" %)((( ... ... @@ -963,29 +963,48 @@ 963 963 * =1: ODD 964 964 * =2: EVEN 965 965 ))) 966 -|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10088|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000 967 -|(% style="width:173px" %)receive timeout|(% style="width:122px" %)HSW10089|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000 968 -|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10090|(% colspan="2" style="width:506px" %)Unit: times. Range: 0~~100 969 -|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10091|(% colspan="2" style="width:506px" %)Unit: s. Range: 0~~30 1290 +|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10088|(% colspan="2" style="width:506px" %)((( 1291 +* Unit: ms. 1292 +* Range: 0 to 30000 1293 +))) 1294 +|(% style="width:173px" %)receive timeout|(% style="width:122px" %)HSW10089|(% colspan="2" style="width:506px" %)((( 1295 +* Unit: ms. 1296 +* Range: 0 to 30000 1297 +))) 1298 +|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10090|(% colspan="2" style="width:506px" %)((( 1299 +* Unit: times. 1300 +* Range: 0 to 100 1301 +))) 1302 +|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10091|(% colspan="2" style="width:506px" %)((( 1303 +* Unit: s. 1304 +* Range: 0 to 30 1305 +))) 970 970 |(% style="width:173px" %)HMI station number|(% style="width:122px" %)HSW10092|(% colspan="2" style="width:506px" %) 971 971 |(% style="width:173px" %)PLC station number|(% style="width:122px" %)HSW10093|(% colspan="2" style="width:506px" %) 972 972 |(% colspan="1" rowspan="2" style="width:102px" %)CAN port|(% style="width:173px" %)CAN1 baud rate|(% style="width:122px" %)HSW010116|(% style="width:299px" %)((( 973 -Unit: K, the baud rate must be an integer, for example, when the baud rate required is 250000, just enter 250. 1309 +Unit: K, the baud rate must be an integer. 1310 + 1311 +For example, when the baud rate required is 250000, just enter 250. 974 974 )))|(% colspan="1" rowspan="2" style="width:218px" %)**✎Note: **If baud rate has been modified,please wait 5 seconds,then restart the HMI to take effect. 975 -|(% style="width:173px" %)CAN2 baud rate|(% style="width:122px" %)HSW010117|(% style="width:299px" %)Unit: K, the baud rate must be an integer, for example, when the baud rate required is 250000, just enter 250. 1313 +|(% style="width:173px" %)CAN2 baud rate|(% style="width:122px" %)HSW010117|(% style="width:299px" %)((( 1314 +Unit: K, the baud rate must be an integer. 976 976 977 -== **Ethernet communication configuration** == 1316 +For example, when the baud rate required is 250000, just enter 250. 1317 +))) 978 978 1319 +== Ethernet communication configuration == 1320 + 979 979 (% class="table-bordered" %) 980 -| =(% style="width:;" %)**No.**|=(% style="width:;" %)**Function**|=(% style="width:;" %)**Address**|=(% style="width:;" %)**Description**1322 +|(% style="width:40px" %)**No.**|(% style="width:295px" %)**Function**|(% style="width:220px" %)**Address**|(% style="width:336px" %)**Description** 981 981 |(% rowspan="7" style="width:40px" %)1|(% colspan="1" rowspan="7" style="width:295px" %)Ethernet parameter configuration for communication number 1 in list. Configure those addresses according to connected device. After configuration, wait for 5 seconds and restart the HMI.|(% style="width:220px" %)HSW11004|(% style="width:336px" %)Device IP address high word 1 982 982 |(% style="width:220px" %)HSW11005|(% style="width:336px" %)Device IP address high word 2 983 983 |(% style="width:220px" %)HSW11006|(% style="width:336px" %)Device IP address high word 3 984 984 |(% style="width:220px" %)HSW11007|(% style="width:336px" %)Device IP address high word 4 985 985 |(% style="width:220px" %)HSW11008|(% style="width:336px" %)Device Port number 986 -|(% style="width:220px" %)HSW11009|=(% style="width: 336px;" %)((( 987 -* =2 TCP 988 -* =3 UDP 1328 +|(% style="width:220px" %)HSW11009|(% style="width:336px" %)((( 1329 +~=2 TCP 1330 + 1331 +~=3 UDP 989 989 ))) 990 990 |(% style="width:220px" %)HSW11010|(% style="width:336px" %)Reserved 991 991 |(% rowspan="7" style="width:40px" %)2|(% colspan="1" rowspan="7" style="width:295px" %)Ethernet parameter configuration for communication number 2 in list. Configure those addresses according to connected device. After configuration, wait for 5 seconds and restart the HMI.|(% style="width:220px" %)HSW11011|(% style="width:336px" %)Device IP address high word 1 ... ... @@ -993,9 +993,10 @@ 993 993 |(% style="width:220px" %)HSW11013|(% style="width:336px" %)Device IP address high word 3 994 994 |(% style="width:220px" %)HSW11014|(% style="width:336px" %)Device IP address high word 4 995 995 |(% style="width:220px" %)HSW11015|(% style="width:336px" %)Device Port number 996 -|(% style="width:220px" %)HSW11016|=(% style="width: 336px;" %)((( 997 -* =2 TCP 998 -* =3 UDP 1339 +|(% style="width:220px" %)HSW11016|(% style="width:336px" %)((( 1340 +~=2 TCP 1341 + 1342 +~=3 UDP 999 999 ))) 1000 1000 |(% style="width:220px" %)HSW11017|(% style="width:336px" %)Reserved 1001 1001 |(% style="width:40px" %)…|(% style="width:295px" %) |(% style="width:220px" %)…|(% style="width:336px" %)… ... ... @@ -1004,7 +1004,11 @@ 1004 1004 |(% style="width:220px" %)HSW11223|(% style="width:336px" %)Device IP address high word 3 1005 1005 |(% style="width:220px" %)HSW11224|(% style="width:336px" %)Device IP address high word 4 1006 1006 |(% style="width:220px" %)HSW11225|(% style="width:336px" %)Device Port number 1007 -|(% style="width:220px" %)HSW11226|=(% style="width: 336px;" %)2 TCP; =3 UDP 1351 +|(% style="width:220px" %)HSW11226|(% style="width:336px" %)((( 1352 +~=2 TCP; 1353 + 1354 +~=3 UDP 1355 +))) 1008 1008 |(% style="width:220px" %)HSW11227|(% style="width:336px" %)Reserved 1009 1009 1010 1010 (% class="box infomessage" %) ... ... @@ -1012,7 +1012,7 @@ 1012 1012 **✎Note:** The number of Ethernet connections supported by different HMI series varies. 1013 1013 ))) 1014 1014 1015 -== **Communication control**==1363 +== Communication control == 1016 1016 1017 1017 (% class="table-bordered" %) 1018 1018 |=(% style="width: 135px;" %)**Communication No.**|=(% style="width: 102px;" %)**Station No.**|=(% style="width: 185px;" %)**Control bit**|=(% style="width: 191px;" %)**Communication lamp**|=(% style="width: 271px;" %)**Description**