Changes for page 13 HMI Internal Registers

Last modified by Jett on 2025/04/28 16:07

From version 4.3
edited by Stone Wu
on 2022/08/06 14:11
Change comment: There is no comment for this version
To version 19.1
edited by Hunter
on 2023/02/18 14:04
Change comment: There is no comment for this version

Summary

Details

Page properties
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.Stone
1 +XWiki.Hunter
Content
... ... @@ -4,11 +4,11 @@
4 4  
5 5  *HSW, HDW, HUW, HAW are word address, HSX, HDX, HUX, HAX are bit address.
6 6  
7 -1. **System data area (HSW): **A special register defined by the system.
8 -1. **Data storage area (HDW/HDX): **Users store user data.
9 -1. **System data area (HUW): **A special register defined by the system.
10 -1. **System Data (HAW)**: System register used for power-off save.
11 -1. **Recipe index area (RPW): **System register used for recipe index.
7 +* **System data area (HSW): **A special register defined by the system.
8 +* **Data storage area (HDW/HDX): **Users store user data.
9 +* **System data area (HUW): **A special register defined by the system.
10 +* **System Data (HAW)**: System register used for power-off save.
11 +* **Recipe index area (RPW): **System register used for recipe index.
12 12  
13 13  HMI internal registers are divided into bit address and word address, which can be accessed in two ways (take HDW as an example).
14 14  
... ... @@ -25,6 +25,19 @@
25 25  * The address of the bit address HDX is with a decimal point while word addresses are integers.
26 26  )))
27 27  
28 += Address ranges table =
29 +
30 +|=(% scope="row" style="width: 218px;" %)Address Type\HMI Series|=(% style="width: 228px;" %)General Series|=(% style="width: 200px;" %)i Series/HMI+ models|=(% style="width: 136px;" %)ie Series|=(% style="width: 232px;" %)ig Series
31 +|=(% style="width: 218px;" %)HDW|(% style="width:228px" %)HDW0-HDW299999|HDW0-HDW299999|HDW0-HDW299999|HDW0-HDW299999
32 +|=(% style="width: 218px;" %)HSW|(% style="width:228px" %)HSW0-HSW14999|HSW0-HSW14999|HSW0-HSW14999|HSW0-HSW14999
33 +|=(% style="width: 218px;" %)HAW|(% style="width:228px" %)HAW0-HAW199999|HAW0-HAW199999|HAW0-HAW199999|HAW0-HAW199999
34 +|=(% style="width: 218px;" %)HUW|(% style="width:228px" %)HUW0-HUW1599|HUW0-HUW1599|HUW0-HUW1599|HUW0-HUW1599
35 +|=(% style="width: 218px;" %)HDX|(% style="width:228px" %)HDX0.0-HDX299999.15|HDX0.0-HDX299999.15|HDX0.0-HDX299999.15|HDX0.0-HDX299999.15
36 +|=(% style="width: 218px;" %)HSX|(% style="width:228px" %)HSX0.0-HSX14999.15|HSX0.0-HSX14999.15|HSX0-HSX14999.15|HSX0.0-HSX14999.15
37 +|=(% style="width: 218px;" %)HAX|(% style="width:228px" %)HAX0.0-HAX199999.15|HAX0.0-HAX199999.15|HAX0.0-HAX199999.15|HAX0.0-HAX199999.15
38 +|=(% style="width: 218px;" %)HUX|(% style="width:228px" %)HUX0.0-HUX1599.15|HUX0.0-HUX1599.15|HUX0.0-HUX1599.15|HUX0.0-HUX1599.15
39 +|=(% style="width: 218px;" %)RPW|(% style="width:228px" %) |RPW000000-RPW990450|RPW000000-RPW990450|RPW000000-RPW990450
40 +
28 28  = **Data storage area (HDW/HDX)** =
29 29  
30 30  It is used to save the temporary data of project.
... ... @@ -241,8 +241,8 @@
241 241  * =2: HSX521.1=1, delete all trend graph.
242 242  * =4: HSX521.2=1, delete all alarms.
243 243  * =16: HSX521.4=1, delete history XY plot.
244 -* =32: HSX521.5=1, delete data records in SD card or flash dish;(Please make a setting which is saved to flash disk or SD card in project setting).
245 -* =64: HSX521.6=1, delete alarms records in SD card or flash dish; (Please make a setting which is saved to flash disk or SD card in project setting).
257 +* =32: HSX521.5=1, delete data records in SD card or USB flash disk;(Please make a setting which is saved to USB flash disk or SD card in project setting).
258 +* =64: HSX521.6=1, delete alarms records in SD card or USB flash disk; (Please make a setting which is saved to USB flash disk or SD card in project setting).
246 246  )))
247 247  |=(% style="width: 160px;" %)HSW522|(% style="width:282px" %)Copy and paste the alarm/data files in flash to the USB flash disk|(% style="width:452px" %)(((
248 248  * =0: No operation
... ... @@ -485,6 +485,8 @@
485 485  * =0, Default value
486 486  * =1, Release the alarm generated before the last power-down when starting up
487 487  )))
501 +|=(% style="width: 160px;" %)HSW1200|(% colspan="1" rowspan="2" style="width:282px" %)TSAP settings for HMI in the Siemens LOGO! 8 protocol(ig series or HMI V2.0)|(% style="width:452px" %)HMI local TSAP, which corresponds to the remote TSAP of PLC
502 +|=(% style="width: 160px;" %)HSW1201|(% style="width:452px" %)HMI remote TSAP, which corresponds to the local TSAP of PLC
488 488  |=(% style="width: 160px;" %)HSW1450|(% style="width:282px" %)Enable objects level password function|(% style="width:452px" %)(((
489 489  * =0, Disable
490 490  * =1, Enable
... ... @@ -591,6 +591,9 @@
591 591  * =0: Server connection exception
592 592  * =1: Server connection is OK
593 593  )))
609 +|=(% style="width: 160px;" %)HSW1740|(% style="width:282px" %)Wi-fi signal strength|(% style="width:452px" %)(((
610 +Display the value of Wi-fi signal signal strength, ranges from 0~~100 (Signal strength is automatically obtained only once when HMI is powered on, and it will not be automatically updated. It needs to be used with the HSW1890)
611 +)))
594 594  |=(% style="width: 160px;" %)HSW1741|(% colspan="1" rowspan="12" style="width:282px" %)Related IP register in 4Gnetwork status (It is valid when HMI is connected to 4G)|(% style="width:452px" %)Local IP address high byte 1
595 595  |=(% style="width: 160px;" %)HSW1742|(% style="width:452px" %)Local IP address high byte 2
596 596  |=(% style="width: 160px;" %)HSW1743|(% style="width:452px" %)Local IP address high byte 3
... ... @@ -618,10 +618,180 @@
618 618  * =1: Server connection is OK
619 619  )))
620 620  |=(% style="width: 160px;" %)HSW1761|(% style="width:282px" %)Display 4G network signal strength|(% style="width:452px" %)Signal strength: 0~~31. The greater the value ,the signal is stronger
639 +|=(% style="width: 160px;" %)(((
640 +HSW1762
641 +)))|(% colspan="1" rowspan="13" style="width:282px" %)(((
642 +Note: Valid when Ethernet2 of HMI is plugged into the network cable.
643 +①、When the Ethernet setting is enabled in the project parameters, this register displays the set value.
644 +②. When the Ethernet setting is not enabled in the engineering parameters, the register displays the Ethernet IP automatically acquired by the HMI.
645 +③. When the HMI is not plugged into the network cable, the register will show 0 whether the engineering parameters are set or not.
646 +④.IP related registers can be read and written (only static IP mode can be written).
647 +)))|(% style="width:452px" %)(((
648 +Ethernet2 Local IP address high byte 1
649 +)))
650 +|=(% style="width: 160px;" %)(((
651 +HSW1763
652 +)))|(% style="width:452px" %)(((
653 +Ethernet2 Local IP address high byte 2
654 +)))
655 +|=(% style="width: 160px;" %)(((
656 +HSW1764
657 +)))|(% style="width:452px" %)(((
658 +Ethernet2 Local IP address high byte 3
659 +)))
660 +|=(% style="width: 160px;" %)(((
661 +HSW1765
662 +)))|(% style="width:452px" %)(((
663 +Ethernet2 Local IP address high byte 4
664 +)))
665 +|=(% style="width: 160px;" %)(((
666 +HSW1766
667 +)))|(% style="width:452px" %)(((
668 +Ethernet2 Local mask IP address high byte 1
669 +)))
670 +|=(% style="width: 160px;" %)(((
671 +HSW1767
672 +)))|(% style="width:452px" %)(((
673 +Ethernet2 Local mask IP address high byte 2
674 +)))
675 +|=(% style="width: 160px;" %)(((
676 +HSW1768
677 +)))|(% style="width:452px" %)Ethernet2 Local mask IP address high byte 3
678 +|=(% style="width: 160px;" %)HSW1769|(% style="width:452px" %)Ethernet2 Local mask IP address high byte 4
679 +|=(% style="width: 160px;" %)(((
680 +HSW1770
681 +)))|(% style="width:452px" %)(((
682 +Ethernet2 Local gateway IP address high byte 1
683 +)))
684 +|=(% style="width: 160px;" %)(((
685 +HSW1771
686 +)))|(% style="width:452px" %)(((
687 +Ethernet2 Local gateway IP address high byte 2
688 +)))
689 +|=(% style="width: 160px;" %)(((
690 +HSW1772
691 +)))|(% style="width:452px" %)(((
692 +Ethernet2 Local gateway IP address high byte 3
693 +)))
694 +|=(% style="width: 160px;" %)(((
695 +HSW1773
696 +)))|(% style="width:452px" %)(((
697 +Ethernet2 Local gateway IP address high byte 4
698 +)))
699 +|=(% style="width: 160px;" %)(((
700 +HSW1774
701 +)))|(% style="width:452px" %)(((
702 +Ethernet2 Local Port Address
703 +)))
704 +|=(% style="width: 160px;" %)(((
705 +HSW1775
706 +)))|(% colspan="1" rowspan="6" style="width:282px" %)(((
707 +①Display the MAC code of Ethernet2 NIC
708 +
709 +(hexadecimal display)
710 +
711 +②Read-only mode, not modifiable
712 +)))|(% style="width:452px" %)(((
713 +Ethernet2 Local MAC code high byte 1
714 +)))
715 +|=(% style="width: 160px;" %)(((
716 +HSW1776
717 +)))|(% style="width:452px" %)(((
718 +Ethernet2 Local MAC code high byte 2
719 +)))
720 +|=(% style="width: 160px;" %)(((
721 +HSW1777
722 +)))|(% style="width:452px" %)(((
723 +Ethernet2 Local MAC code high byte 3
724 +)))
725 +|=(% style="width: 160px;" %)(((
726 +HSW1778
727 +)))|(% style="width:452px" %)(((
728 +Ethernet2 Local MAC code high byte 4
729 +)))
730 +|=(% style="width: 160px;" %)(((
731 +HSW1779
732 +)))|(% style="width:452px" %)(((
733 +Ethernet2 Local MAC code high byte 5
734 +)))
735 +|=(% style="width: 160px;" %)(((
736 +HSW1780
737 +)))|(% style="width:452px" %)(((
738 +Ethernet2 Local MAC code high byte 6
739 +)))
740 +|=(% style="width: 160px;" %)(((
741 +HSW1781
742 +)))|(% colspan="1" rowspan="8" style="width:282px" %)(((
743 +①Display and modify DNS1 and DNS2 of Ethernet2
744 +
745 +②Related registers can be read and written mode (only static IP mode can be written)
746 +)))|(% style="width:452px" %)(((
747 +Ethernet2 Local DNS1 address high byte 1
748 +)))
749 +|=(% style="width: 160px;" %)(((
750 +HSW1782
751 +)))|(% style="width:452px" %)(((
752 +Ethernet2 Local DNS1 address high byte 2
753 +)))
754 +|=(% style="width: 160px;" %)(((
755 +HSW1783
756 +)))|(% style="width:452px" %)(((
757 +Ethernet2 Local DNS1 address high byte 3
758 +)))
759 +|=(% style="width: 160px;" %)(((
760 +HSW1784
761 +)))|(% style="width:452px" %)(((
762 +Ethernet2 Local DNS1 address high byte 4
763 +)))
764 +|=(% style="width: 160px;" %)(((
765 +HSW1785
766 +)))|(% style="width:452px" %)(((
767 +Ethernet2 Local DNS2 address high byte 1
768 +)))
769 +|=(% style="width: 160px;" %)(((
770 +HSW1786
771 +)))|(% style="width:452px" %)(((
772 +Ethernet2 Local DNS2 address high byte 2
773 +)))
774 +|=(% style="width: 160px;" %)(((
775 +HSW1787
776 +)))|(% style="width:452px" %)(((
777 +Ethernet2 Local DNS2 address high byte 3
778 +)))
779 +|=(% style="width: 160px;" %)(((
780 +HSW1788
781 +)))|(% style="width:452px" %)(((
782 +Ethernet2 Local DNS2 address high byte 4
783 +)))
784 +|=(% style="width: 160px;" %)(((
785 +HSW1789
786 +)))|(% colspan="1" style="width:282px" %)(((
787 +Display or set the dynamic or static IP mode of Ethernet2
788 +)))|(% style="width:452px" %)(((
789 +HSX1789.0 = 0, Static IP mode
790 +
791 +HSX1789.0 = 1, dynamic IP mode
792 +)))
793 +|=(% style="width: 160px;" %)(((
794 +HSW1790
795 +)))|(% colspan="1" style="width:282px" %)(((
796 +Confirm Ethernet2 IP, subnet mask, gateway, DNS1, DNS2, and dynamic static IP settings
797 +)))|(% style="width:452px" %)(((
798 +~= 1, confirm the setting (i.e., after modifying IP-related information, set this address to 1, representing confirmation of the modification, after which it will be reset to 0)
799 +)))
800 +|=(% style="width: 160px;" %)(((
801 +HSW1791
802 +)))|(% colspan="1" style="width:282px" %)(((
803 +Network status of the Ethernet2 connection server
804 +)))|(% style="width:452px" %)(((
805 +~= 0, connection to the server is abnormal = 1, connection to the server is normal
806 +)))
621 621  |=(% style="width: 160px;" %)HSW1852|(% style="width:282px" %)Control the interval in two consecutive clicks|(% style="width:452px" %)Limit range: 1~~500ms. The default is 100 ms.
622 622  |=(% style="width: 160px;" %)HSW1853|(% style="width:282px" %)File format for exporting data records to USB flash drive or SD card|(% style="width:452px" %)(((
623 623  * =0: db database
624 624  * =1: CSV
811 +
812 +(Only valid for script function DbToCsvFile)
625 625  )))
626 626  |=(% style="width: 160px;" %)HSW1854|(% style="width:282px" %)High and low word conversion type|(% style="width:452px" %)(((
627 627  * =0: use the old high-low word conversion (default)
... ... @@ -643,14 +643,96 @@
643 643  * =1: download firmware
644 644  * =2: enter the background
645 645  )))
834 +|=(% style="width: 160px;" %)HSW1865|(% style="width:282px" %)Priority connection to the cloud|(% style="width:452px" %)(((
835 +* =0: priority Ethernet
836 +* =1: priority WLAN
837 +* =2: priority 4G
838 +)))
839 +|=(% style="width: 160px;" %)HSW1866|(% style="width:282px" %)Delete the Lua extension module file|(% style="width:452px" %)(((
840 +* =0: delete;
841 +* = Others: do not delete
842 +)))
843 +|=(% style="width: 160px;" %)HSW1867|(% style="width:282px" %)Reset mode|(% style="width:452px" %)(((
844 +Monitor address is set during reset of reset switch, whether to cancel reset,
845 +
846 +* = 0: yes (default);
847 +* = 1: no
848 +)))
849 +|=(% style="width: 160px;" %)HSW1868|(% style="width:282px" %)Double-click or long press the record type table mode|(% style="width:452px" %)(((
850 +Controls whether the button pops up when double-clicking or long pressing on record type table object
851 +
852 +* = 0: yes (default);
853 +* = 1: no
854 +)))
855 +|=(% style="width: 160px;" %)(((
856 +HSW1869
857 +)))|(% style="width:282px" %)(((
858 +Dynamic screensaver countdown
859 +)))|(% style="width:452px" %)(((
860 +Countdown to enter dynamic screensaver effect, unit (S)
861 +)))
862 +|=(% style="width: 160px;" %)(((
863 +HSW1870
864 +)))|(% style="width:282px" %)(((
865 +Display or set the dynamic or static IP mode of Ethernet1
866 +)))|(% style="width:452px" %)(((
867 +HSX1870.0 = 0, Static IP mode
868 +
869 +HSX1870.0 = 1, dynamic IP mode
870 +)))
871 +|=(% style="width: 160px;" %)(((
872 +HSW1871
873 +)))|(% style="width:282px" %)(((
874 +Confirm the IP, subnet mask, gateway, DNS1, DNS2, and dynamic static IP settings for Ethernet1
875 +)))|(% style="width:452px" %)(((
876 +~= 1, confirm the setting (i.e., after modifying IP-related information, set this address to 1, representing confirmation of the modification, after which it will be reset to 0)
877 +)))
878 +|=(% style="width: 160px;" %)(((
879 +HSW1872
880 +)))|(% colspan="1" rowspan="8" style="width:282px" %)(((
881 +①Display and modify DNS1 and DNS2 of Ethernet1
882 +
883 +②Related registers can be read and written mode (only static IP mode can be written)
884 +)))|(% style="width:452px" %)(((
885 +Ethernet1 Local DNS1 address high byte 1
886 +)))
887 +|=(% style="width: 160px;" %)(((
888 +HSW1873
889 +)))|(% style="width:452px" %)Ethernet1 Local DNS1 address high byte 2
890 +|=(% style="width: 160px;" %)(((
891 +HSW1874
892 +)))|(% style="width:452px" %)Ethernet1 Local DNS1 address high byte 3
893 +|=(% style="width: 160px;" %)(((
894 +HSW1875
895 +)))|(% style="width:452px" %)Ethernet1 Local DNS1 address high byte 4
896 +|=(% style="width: 160px;" %)(((
897 +HSW1876
898 +)))|(% style="width:452px" %)Ethernet1 Local DNS2 address high byte 1
899 +|=(% style="width: 160px;" %)(((
900 +HSW1877
901 +)))|(% style="width:452px" %)Ethernet1 Local DNS2 address high byte 2
902 +|=(% style="width: 160px;" %)(((
903 +HSW1878
904 +)))|(% style="width:452px" %)Ethernet1 Local DNS2 address high byte 3
905 +|=(% style="width: 160px;" %)(((
906 +HSW1879
907 +)))|(% style="width:452px" %)Ethernet1 Local DNS2 address high byte 4
908 +|=(% style="width: 160px;" %)HSW1890|(% colspan="1" style="width:282px" %)Enable refresh current network signal|(% style="width:452px" %)(((
909 +* =1: Refresh the network signal once after triggered (This register will be automatically reset after triggered, only update the signal value once after per 15 seconds, not able to update twice in the short interval)
910 +* =Others: not refresh
911 +)))
912 +|=(% style="width: 160px;" %)HSW1891|(% colspan="1" style="width:282px" %)Enable clear cache for screen data  |(% style="width:452px" %)(((
913 +* =1, not clear screen cache when switch language
914 +* =2, trigger clear cache of all screens for once time
915 +* =3, always clear cache of all screen data
916 +)))
646 646  |=(% style="width: 160px;" %)HSW10000~~19999|(% style="width:282px" %)Power-down storage area|(% style="width:452px" %)After restart, the data remains
647 647  |=(% style="width: 160px;" %)HSW10035|(% rowspan="13" style="width:282px" %)(((
648 -**✎Note: **Only valid when the HMI is plugged into the Ethernet cable.
649 -
650 -1. If Ethernet settings is enabled in project parameters, this register displays the set value.
651 -1. If Ethernet settings is not enabled in project parameters, IP would automatically obtained IP.
652 -1. If HMI is not connected to the network, the register is displayed as 0 whether the engineering parameters are set.
653 -1. 4. All IP registers of HMI are read-only.
919 +Note: Valid when Ethernet1 of HMI is plugged into the network cable.
920 +①、When the Ethernet setting is enabled in the project parameters, this register displays the set value.
921 +②. When the Ethernet setting is not enabled in the engineering parameters, the register displays the Ethernet IP automatically acquired by the HMI.
922 +③. When the HMI is not plugged into the network cable, the register will show 0 whether the engineering parameters are set or not.
923 +④.IP related registers can be read and written (only static IP mode can be written).
654 654  )))|(% style="width:452px" %)Local IP address high byte 1
655 655  |=(% style="width: 160px;" %)HSW10036|(% style="width:452px" %)Local IP address high byte 2
656 656  |=(% style="width: 160px;" %)HSW10037|(% style="width:452px" %)Local IP address high byte 3
... ... @@ -665,9 +665,11 @@
665 665  |=(% style="width: 160px;" %)HSW10046|(% style="width:452px" %)Local gateway address high byte 4
666 666  |=(% style="width: 160px;" %)HSW10047|(% style="width:452px" %)Local port address
667 667  |=(% style="width: 160px;" %)HSW10048|(% rowspan="6" style="width:282px" %)(((
668 -Displays the MAC code of the current network card
938 +Display the MAC code of Ethernet1 NIC
669 669  
670 -(Hexadecimal display)
940 +(hexadecimal display)
941 +
942 +②Read-only mode, not modifiable
671 671  )))|(% style="width:452px" %)Local MAC code high word 1
672 672  |=(% style="width: 160px;" %)HSW10049|(% style="width:452px" %)Local MAC code high word 2
673 673  |=(% style="width: 160px;" %)HSW10050|(% style="width:452px" %)Local MAC code high word 3
... ... @@ -674,7 +674,7 @@
674 674  |=(% style="width: 160px;" %)HSW10051|(% style="width:452px" %)Local MAC code high word 4
675 675  |=(% style="width: 160px;" %)HSW10052|(% style="width:452px" %)Local MAC code high word 5
676 676  |=(% style="width: 160px;" %)HSW10053|(% style="width:452px" %)Local MAC code high word 6
677 -|=(% style="width: 160px;" %)HSW10118|(% colspan="1" rowspan="2" style="width:282px" %)TSAP settings for HMI in the Siemens logo! 8 protocol|(% style="width:452px" %)HMI local TSAP, which corresponds to the remote TSAP of PLC
949 +|=(% style="width: 160px;" %)HSW10118|(% colspan="1" rowspan="2" style="width:282px" %)TSAP settings for HMI in the Siemens LOGO! 8 protocol|(% style="width:452px" %)HMI local TSAP, which corresponds to the remote TSAP of PLC
678 678  |=(% style="width: 160px;" %)HSW10119|(% style="width:452px" %)HMI remote TSAP, which corresponds to the local TSAP of PLC
679 679  |=(% style="width: 160px;" %)HSW10461~~10493|(% style="width:282px" %)Remote access password|(% style="width:452px" %)8-character remote access password
680 680  |=(% style="width: 160px;" %)HSW10494~~10558|(% style="width:282px" %)Machine ID (Read only)|(% style="width:452px" %)Machine ID for remote access (read only 64-bit)
... ... @@ -756,11 +756,38 @@
756 756  )))
757 757  |=(% style="width: 160px;" %)HSW11760|(% style="width:282px" %)Screensaver countdown|(% style="width:452px" %)Display the countdown to enter the Screensaver, unit: second.
758 758  |=(% style="width: 160px;" %)HSW11761|(% style="width:282px" %)Screensaver screen number|(% style="width:452px" %)Set the screen number for Screensaver
1031 +|=(% style="width: 160px;" %)(((
1032 +HSW11762
1033 +)))|(% style="width:282px" %)(((
1034 +Dynamic screensaver control address
1035 +)))|(% style="width:452px" %)(((
1036 +HSX11762.0=0, initialize with project configuration;
759 759  
760 -== **Serial port communication configuration** ==
1038 +HSX11762.0=1, initialize with special register configuration;
761 761  
1040 +HSX11762.1=0, disable dynamic screensaver;
1041 +
1042 +HSX11762.1=1, enable dynamic screensaver
1043 +)))
1044 +|=(% style="width: 160px;" %)(((
1045 +HSW11763
1046 +)))|(% style="width:282px" %)(((
1047 +Waiting time to enter the dynamic screensaver
1048 +)))|(% style="width:452px" %)(((
1049 +Waiting time when the screen is not operated, range 1~~720 minutes
1050 +)))
1051 +|=(% style="width: 160px;" %)(((
1052 +HSW11764
1053 +)))|(% style="width:282px" %)(((
1054 +Animated screensaver animation type
1055 +)))|(% style="width:452px" %)(((
1056 +~=0: Raster,=1: Blinds,=2: Bubble
1057 +)))
1058 +
1059 +== Serial port communication configuration ==
1060 +
762 762  (% class="table-bordered" %)
763 -|=(% style="width: 102px;" %)Port|=(% style="width: 173px;" %)**Function**|=(% style="width: 122px;" %)**Address**|=(% colspan="2" style="width: 506px;" %)**Description**
1062 +|=(% scope="row" style="width: 102px;" %)Port|=(% style="width: 173px;" %)**Function**|=(% style="width: 122px;" %)**Address**|=(% colspan="2" style="width: 506px;" %)**Description**
764 764  |(% colspan="1" rowspan="11" style="width:102px" %)COM1|(% style="width:173px" %)Communication mode|(% style="width:122px" %)HSW10061|(% colspan="2" style="width:506px" %)(((
765 765  * =0: RS232
766 766  * =1: RS485
... ... @@ -790,10 +790,22 @@
790 790  * =1: ODD
791 791  * =2: EVEN
792 792  )))
793 -|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10066|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000
794 -|(% style="width:173px" %)reveive timeout|(% style="width:122px" %)HSW10067|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000
795 -|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10068|(% colspan="2" style="width:506px" %)Unit: times. Range: 0~~100
796 -|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10069|(% colspan="2" style="width:506px" %)Unit: s. Range: 0~~300
1092 +|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10066|(% colspan="2" style="width:506px" %)(((
1093 +* Unit: ms.
1094 +* Range: 0 to 30000
1095 +)))
1096 +|(% style="width:173px" %)reveive timeout|(% style="width:122px" %)HSW10067|(% colspan="2" style="width:506px" %)(((
1097 +* Unit: ms.
1098 +* Range: 0 to 30000
1099 +)))
1100 +|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10068|(% colspan="2" style="width:506px" %)(((
1101 +* Unit: times.
1102 +* Range: 0 to 100
1103 +)))
1104 +|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10069|(% colspan="2" style="width:506px" %)(((
1105 +* Unit: s.
1106 +* Range: 0 to 300
1107 +)))
797 797  |(% style="width:173px" %)HMI station number|(% style="width:122px" %)HSW10070|(% colspan="2" style="width:506px" %)
798 798  |(% style="width:173px" %)PLC station number|(% style="width:122px" %)HSW10071|(% colspan="2" style="width:506px" %)
799 799  |(% colspan="1" rowspan="11" style="width:102px" %)COM1-2|(% style="width:173px" %)Communication mode|(% style="width:122px" %)HSW10094|(% colspan="2" style="width:506px" %)(((
... ... @@ -826,10 +826,22 @@
826 826  * =1: ODD
827 827  * =2: EVEN
828 828  )))
829 -|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10099|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000
830 -|(% style="width:173px" %)receive timeout|(% style="width:122px" %)HSW10100|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000
831 -|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10101|(% colspan="2" style="width:506px" %)Unit: times. Range: 0~~100
832 -|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10102|(% colspan="2" style="width:506px" %)Unit: s. Range: 0~~30
1140 +|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10099|(% colspan="2" style="width:506px" %)(((
1141 +* Unit: ms.
1142 +* Range: 0 to 30000
1143 +)))
1144 +|(% style="width:173px" %)receive timeout|(% style="width:122px" %)HSW10100|(% colspan="2" style="width:506px" %)(((
1145 +* Unit: ms.
1146 +* Range: 0 to 30000
1147 +)))
1148 +|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10101|(% colspan="2" style="width:506px" %)(((
1149 +* Unit: times.
1150 +* Range: 0 to 100
1151 +)))
1152 +|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10102|(% colspan="2" style="width:506px" %)(((
1153 +* Unit: s.
1154 +* Range: 0 to 30
1155 +)))
833 833  |(% style="width:173px" %)HMI station number|(% style="width:122px" %)HSW10103|(% colspan="2" style="width:506px" %)
834 834  |(% style="width:173px" %)PLC station number|(% style="width:122px" %)HSW10104|(% colspan="2" style="width:506px" %)
835 835  |(% colspan="1" rowspan="11" style="width:102px" %)COM1-3|(% style="width:173px" %)Communication mode|(% style="width:122px" %)HSW10120|(% colspan="2" style="width:506px" %)(((
... ... @@ -862,10 +862,22 @@
862 862  * =1: ODD
863 863  * =2: EVEN
864 864  )))
865 -|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10125|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000
866 -|(% style="width:173px" %)receive timeout|(% style="width:122px" %)HSW10126|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000
867 -|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10127|(% colspan="2" style="width:506px" %)Unit: times. Range: 0~~100
868 -|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10128|(% colspan="2" style="width:506px" %)Unit: s. Range: 0~~30
1188 +|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10125|(% colspan="2" style="width:506px" %)(((
1189 +* Unit: ms.
1190 +* Range: 0 to 30000
1191 +)))
1192 +|(% style="width:173px" %)receive timeout|(% style="width:122px" %)HSW10126|(% colspan="2" style="width:506px" %)(((
1193 +* Unit: ms.
1194 +* Range: 0 to 30000
1195 +)))
1196 +|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10127|(% colspan="2" style="width:506px" %)(((
1197 +* Unit: times.
1198 +* Range: 0 to 100
1199 +)))
1200 +|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10128|(% colspan="2" style="width:506px" %)(((
1201 +* Unit: s.
1202 +* Range: 0 to 30
1203 +)))
869 869  |(% style="width:173px" %)HMI station number|(% style="width:122px" %)HSW10129|(% colspan="2" style="width:506px" %)
870 870  |(% style="width:173px" %)PLC station number|(% style="width:122px" %)HSW10130|(% colspan="2" style="width:506px" %)
871 871  |(% colspan="1" rowspan="11" style="width:102px" %)COM2|(% style="width:173px" %)Communication mode|(% style="width:122px" %)HSW10072|(% colspan="2" style="width:506px" %)(((
... ... @@ -896,10 +896,22 @@
896 896  * =1: ODD
897 897  * =2: EVEN
898 898  )))
899 -|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10077|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000
900 -|(% style="width:173px" %)receive timeout|(% style="width:122px" %)HSW10078|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000
901 -|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10079|(% colspan="2" style="width:506px" %)Unit: times. Range: 0~~100
902 -|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10080|(% colspan="2" style="width:506px" %)Unit: s. Range: 0~~30
1234 +|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10077|(% colspan="2" style="width:506px" %)(((
1235 +* Unit: ms.
1236 +* Range: 0 to 30000
1237 +)))
1238 +|(% style="width:173px" %)receive timeout|(% style="width:122px" %)HSW10078|(% colspan="2" style="width:506px" %)(((
1239 +* Unit: ms.
1240 +* Range: 0 to 30000
1241 +)))
1242 +|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10079|(% colspan="2" style="width:506px" %)(((
1243 +* Unit: times.
1244 +* Range: 0 to 100
1245 +)))
1246 +|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10080|(% colspan="2" style="width:506px" %)(((
1247 +* Unit: s.
1248 +* Range: 0 to 30
1249 +)))
903 903  |(% style="width:173px" %)HMI station number|(% style="width:122px" %)HSW10081|(% colspan="2" style="width:506px" %)
904 904  |(% style="width:173px" %)PLC station number|(% style="width:122px" %)HSW10082|(% colspan="2" style="width:506px" %)
905 905  |(% colspan="1" rowspan="11" style="width:102px" %)COM2-2|(% style="width:173px" %)Communication mode|(% style="width:122px" %)HSW10105|(% colspan="2" style="width:506px" %)(((
... ... @@ -930,10 +930,22 @@
930 930  * =1: ODD
931 931  * =2: EVEN
932 932  )))
933 -|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10110|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000
934 -|(% style="width:173px" %)receive timeout|(% style="width:122px" %)HSW10111|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000
935 -|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10112|(% colspan="2" style="width:506px" %)Unit: times. Range: 0~~100
936 -|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10113|(% colspan="2" style="width:506px" %)Unit: s. Range: 0~~30
1280 +|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10110|(% colspan="2" style="width:506px" %)(((
1281 +* Unit: ms.
1282 +* Range: 0 to 30000
1283 +)))
1284 +|(% style="width:173px" %)receive timeout|(% style="width:122px" %)HSW10111|(% colspan="2" style="width:506px" %)(((
1285 +* Unit: ms.
1286 +* Range: 0 to 30000
1287 +)))
1288 +|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10112|(% colspan="2" style="width:506px" %)(((
1289 +* Unit: times.
1290 +* Range: 0 to 100
1291 +)))
1292 +|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10113|(% colspan="2" style="width:506px" %)(((
1293 +* Unit: s.
1294 +* Range: 0 to 30
1295 +)))
937 937  |(% style="width:173px" %)HMI station number|(% style="width:122px" %)HSW10114|(% colspan="2" style="width:506px" %)
938 938  |(% style="width:173px" %)PLC station number|(% style="width:122px" %)HSW10115|(% colspan="2" style="width:506px" %)
939 939  |(% colspan="1" rowspan="11" style="width:102px" %)COM3|(% style="width:173px" %)Communication mode|(% style="width:122px" %)HSW10083|(% colspan="2" style="width:506px" %)(((
... ... @@ -963,29 +963,48 @@
963 963  * =1: ODD
964 964  * =2: EVEN
965 965  )))
966 -|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10088|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000
967 -|(% style="width:173px" %)receive timeout|(% style="width:122px" %)HSW10089|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000
968 -|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10090|(% colspan="2" style="width:506px" %)Unit: times. Range: 0~~100
969 -|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10091|(% colspan="2" style="width:506px" %)Unit: s. Range: 0~~30
1325 +|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10088|(% colspan="2" style="width:506px" %)(((
1326 +* Unit: ms.
1327 +* Range: 0 to 30000
1328 +)))
1329 +|(% style="width:173px" %)receive timeout|(% style="width:122px" %)HSW10089|(% colspan="2" style="width:506px" %)(((
1330 +* Unit: ms.
1331 +* Range: 0 to 30000
1332 +)))
1333 +|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10090|(% colspan="2" style="width:506px" %)(((
1334 +* Unit: times.
1335 +* Range: 0 to 100
1336 +)))
1337 +|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10091|(% colspan="2" style="width:506px" %)(((
1338 +* Unit: s.
1339 +* Range: 0 to 30
1340 +)))
970 970  |(% style="width:173px" %)HMI station number|(% style="width:122px" %)HSW10092|(% colspan="2" style="width:506px" %)
971 971  |(% style="width:173px" %)PLC station number|(% style="width:122px" %)HSW10093|(% colspan="2" style="width:506px" %)
972 972  |(% colspan="1" rowspan="2" style="width:102px" %)CAN port|(% style="width:173px" %)CAN1 baud rate|(% style="width:122px" %)HSW010116|(% style="width:299px" %)(((
973 -Unit: K, the baud rate must be an integer, for example, when the baud rate required is 250000, just enter 250.
1344 +Unit: K, the baud rate must be an integer.
1345 +
1346 +For example, when the baud rate required is 250000, just enter 250.
974 974  )))|(% colspan="1" rowspan="2" style="width:218px" %)**✎Note: **If baud rate has been modified,please wait 5 seconds,then restart the HMI to take effect.
975 -|(% style="width:173px" %)CAN2 baud rate|(% style="width:122px" %)HSW010117|(% style="width:299px" %)Unit: K, the baud rate must be an integer, for example, when the baud rate required is 250000, just enter 250.
1348 +|(% style="width:173px" %)CAN2 baud rate|(% style="width:122px" %)HSW010117|(% style="width:299px" %)(((
1349 +Unit: K, the baud rate must be an integer.
976 976  
977 -== **Ethernet communication configuration** ==
1351 +For example, when the baud rate required is 250000, just enter 250.
1352 +)))
978 978  
1354 +== Ethernet communication configuration ==
1355 +
979 979  (% class="table-bordered" %)
980 -|=(% style="width: 40px;" %)**No.**|=(% style="width: 295px;" %)**Function**|=(% style="width: 220px;" %)**Address**|=(% style="width: 336px;" %)**Description**
1357 +|(% style="width:40px" %)**No.**|(% style="width:295px" %)**Function**|(% style="width:220px" %)**Address**|(% style="width:336px" %)**Description**
981 981  |(% rowspan="7" style="width:40px" %)1|(% colspan="1" rowspan="7" style="width:295px" %)Ethernet parameter configuration for communication number 1 in list. Configure those addresses according to connected device. After configuration, wait for 5 seconds and restart the HMI.|(% style="width:220px" %)HSW11004|(% style="width:336px" %)Device IP address high word 1
982 982  |(% style="width:220px" %)HSW11005|(% style="width:336px" %)Device IP address high word 2
983 983  |(% style="width:220px" %)HSW11006|(% style="width:336px" %)Device IP address high word 3
984 984  |(% style="width:220px" %)HSW11007|(% style="width:336px" %)Device IP address high word 4
985 985  |(% style="width:220px" %)HSW11008|(% style="width:336px" %)Device Port number
986 -|(% style="width:220px" %)HSW11009|=(% style="width: 336px;" %)(((
987 -* =2 TCP
988 -* =3 UDP
1363 +|(% style="width:220px" %)HSW11009|(% style="width:336px" %)(((
1364 +~=2 TCP
1365 +
1366 +~=3 UDP
989 989  )))
990 990  |(% style="width:220px" %)HSW11010|(% style="width:336px" %)Reserved
991 991  |(% rowspan="7" style="width:40px" %)2|(% colspan="1" rowspan="7" style="width:295px" %)Ethernet parameter configuration for communication number 2 in list. Configure those addresses according to connected device. After configuration, wait for 5 seconds and restart the HMI.|(% style="width:220px" %)HSW11011|(% style="width:336px" %)Device IP address high word 1
... ... @@ -993,9 +993,10 @@
993 993  |(% style="width:220px" %)HSW11013|(% style="width:336px" %)Device IP address high word 3
994 994  |(% style="width:220px" %)HSW11014|(% style="width:336px" %)Device IP address high word 4
995 995  |(% style="width:220px" %)HSW11015|(% style="width:336px" %)Device Port number
996 -|(% style="width:220px" %)HSW11016|=(% style="width: 336px;" %)(((
997 -* =2 TCP
998 -* =3 UDP
1374 +|(% style="width:220px" %)HSW11016|(% style="width:336px" %)(((
1375 +~=2 TCP
1376 +
1377 +~=3 UDP
999 999  )))
1000 1000  |(% style="width:220px" %)HSW11017|(% style="width:336px" %)Reserved
1001 1001  |(% style="width:40px" %)…|(% style="width:295px" %) |(% style="width:220px" %)…|(% style="width:336px" %)…
... ... @@ -1004,7 +1004,11 @@
1004 1004  |(% style="width:220px" %)HSW11223|(% style="width:336px" %)Device IP address high word 3
1005 1005  |(% style="width:220px" %)HSW11224|(% style="width:336px" %)Device IP address high word 4
1006 1006  |(% style="width:220px" %)HSW11225|(% style="width:336px" %)Device Port number
1007 -|(% style="width:220px" %)HSW11226|=(% style="width: 336px;" %)2 TCP; =3 UDP
1386 +|(% style="width:220px" %)HSW11226|(% style="width:336px" %)(((
1387 +~=2 TCP;
1388 +
1389 +~=3 UDP
1390 +)))
1008 1008  |(% style="width:220px" %)HSW11227|(% style="width:336px" %)Reserved
1009 1009  
1010 1010  (% class="box infomessage" %)
... ... @@ -1012,7 +1012,7 @@
1012 1012  **✎Note:** The number of Ethernet connections supported by different HMI series varies.
1013 1013  )))
1014 1014  
1015 -== **Communication control** ==
1398 +== Communication control ==
1016 1016  
1017 1017  (% class="table-bordered" %)
1018 1018  |=(% style="width: 135px;" %)**Communication No.**|=(% style="width: 102px;" %)**Station No.**|=(% style="width: 185px;" %)**Control bit**|=(% style="width: 191px;" %)**Communication lamp**|=(% style="width: 271px;" %)**Description**