Changes for page 13 HMI Internal Registers
Last modified by Jett on 2025/04/28 16:07
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -339,11 +339,9 @@ 339 339 * HDX882.1=0 SD card doesn't execute storage or storage finished. 340 340 * HDX882.1=1 SD card is reading data, don't remove SD card. 341 341 ))) 342 -|=(% style="width: 160px;" %)HSW884|(% style="width:282px" %)Enter the system network configuration interface|(% style="width:452px" %)((( 343 -* =0: Do not enter the network configuration interface 344 -* =1: Enter the system network configuration interface. 345 -** ig series HMI only supports to enter the system interface 346 - 342 +|=(% style="width: 160px;" %)HSW884|(% style="width:282px" %)Enter setup screen|(% style="width:452px" %)((( 343 +* = 0: Do not into setup screen 344 +* = 1: Enter setup screen 347 347 ))) 348 348 |=(% style="width: 160px;" %)HSW885|(% style="width:282px" %)When the control object hides the address is read failed (communication failure), set the display mode of the object|(% style="width:452px" %)((( 349 349 * = 0: displayed by object setting. ... ... @@ -512,10 +512,6 @@ 512 512 * HSX1502.0=1: Modification comfirmed. Save the data of HSW1450~~HSW1501 to a file for immediate effect. 513 513 * HSX1502.1=1:Modification cancelled. Restore the current data of hSW1450-HSW1501 to the data saved in the file last time. 514 514 ))) 515 -|=(% style="width: 160px;" %)HSW1509|(% style="width:282px" %)Curve width|(% style="width:452px" %)((( 516 -* =0: Use the curve width set by project default. 517 -* =1 to 10: use special register to set curve width. 518 -))) 519 519 |=(% style="width: 160px;" %)HSW1603|(% style="width:282px" %)Number of current unreleased alarms|(% style="width:452px" %)The number of current unreleased alarms in alarm record file. 520 520 |=(% style="width: 160px;" %)HSW1604|(% style="width:282px" %)The auxiliary judgment address when the control bit in the Object Lock fails to be read|(% style="width:452px" %)((( 521 521 * =0: The auxiliary address is invalid. ... ... @@ -643,9 +643,6 @@ 643 643 * =1: download firmware 644 644 * =2: enter the background 645 645 ))) 646 -|=(% style="width: 160px;" %)HSW1866|(% style="width:282px" %) |(% style="width:452px" %) 647 -|=(% style="width: 160px;" %)HSW1867|(% style="width:282px" %) |(% style="width:452px" %)Monitor address is set during reset of reset switch, whether to cancel reset, default = 0, yes; = 1, no 648 -|=(% style="width: 160px;" %)HSW1868|(% style="width:282px" %) |(% style="width:452px" %)Controls whether the button pops up when double-clicking or long-clicking on a record-like form widget, default = 0, yes; = 1, no 649 649 |=(% style="width: 160px;" %)HSW10000~~19999|(% style="width:282px" %)Power-down storage area|(% style="width:452px" %)After restart, the data remains 650 650 |=(% style="width: 160px;" %)HSW10035|(% rowspan="13" style="width:282px" %)((( 651 651 **✎Note: **Only valid when the HMI is plugged into the Ethernet cable. ... ... @@ -1018,7 +1018,7 @@ 1018 1018 == **Communication control** == 1019 1019 1020 1020 (% class="table-bordered" %) 1021 -| =(% style="width:;" %)**Communication No.**|=(% style="width:;" %)**Station No.**|=(% style="width:;" %)**Control bit**|=(% style="width:;" %)**Communication lamp**|=(% style="width:;" %)**Description**1012 +|(% style="width:135px" %)**Communication No.**|(% style="width:102px" %)**Station No.**|(% style="width:185px" %)**Control bit**|(% style="width:191px" %)**Communication lamp**|(% style="width:271px" %)**Description** 1022 1022 |(% colspan="1" rowspan="16" style="width:135px" %)1|(% style="width:102px" %)0~~15|(% style="width:185px" %)HSX550.0~HSX550.15|(% style="width:191px" %)HSX558.0~HSX558.15|(% rowspan="160" style="width:271px" %)Communication number refers to the number in "Communication Port Configuration". A number provides 256 device station numbers. Each station number corresponds to a communication control bit and a communication indicator bit. Registers HSX550.0 to HSX805.15 are used to control the station numbers from 0 to 127, and registers HSX1150.0 to HSX1405.15 are used to control station numbers 128 to 255. 1023 1023 |(% style="width:102px" %)16~~31|(% style="width:185px" %)HSX551.0~HSX551.15|(% style="width:191px" %)HSX559.0~HSX559.15 1024 1024 |(% style="width:102px" %)32~~47|(% style="width:185px" %)HSX552.0~HSX552.15|(% style="width:191px" %)HSX560.0~HSX560.15