Changes for page 13 HMI Internal Registers
Last modified by Jett on 2025/04/28 16:07
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -342,7 +342,7 @@ 342 342 |=(% style="width: 160px;" %)HSW884|(% style="width:282px" %)Enter the system network configuration interface|(% style="width:452px" %)((( 343 343 * =0: Do not enter the network configuration interface 344 344 * =1: Enter the system network configuration interface. 345 -** ig series HMI only supports to enter the system interface 345 +** (ig series HMI only supports to enter the system interface) 346 346 347 347 ))) 348 348 |=(% style="width: 160px;" %)HSW885|(% style="width:282px" %)When the control object hides the address is read failed (communication failure), set the display mode of the object|(% style="width:452px" %)((( ... ... @@ -512,10 +512,6 @@ 512 512 * HSX1502.0=1: Modification comfirmed. Save the data of HSW1450~~HSW1501 to a file for immediate effect. 513 513 * HSX1502.1=1:Modification cancelled. Restore the current data of hSW1450-HSW1501 to the data saved in the file last time. 514 514 ))) 515 -|=(% style="width: 160px;" %)HSW1509|(% style="width:282px" %)Curve width|(% style="width:452px" %)((( 516 -* =0: Use the curve width set by project default. 517 -* =1 to 10: use special register to set curve width. 518 -))) 519 519 |=(% style="width: 160px;" %)HSW1603|(% style="width:282px" %)Number of current unreleased alarms|(% style="width:452px" %)The number of current unreleased alarms in alarm record file. 520 520 |=(% style="width: 160px;" %)HSW1604|(% style="width:282px" %)The auxiliary judgment address when the control bit in the Object Lock fails to be read|(% style="width:452px" %)((( 521 521 * =0: The auxiliary address is invalid. ... ... @@ -643,9 +643,6 @@ 643 643 * =1: download firmware 644 644 * =2: enter the background 645 645 ))) 646 -|=(% style="width: 160px;" %)HSW1866|(% style="width:282px" %)Delete the LUa extension module file|(% style="width:452px" %)=1, delete; = Others, do not delete 647 -|=(% style="width: 160px;" %)HSW1867|(% style="width:282px" %) |(% style="width:452px" %)Monitor address is set during reset of reset switch, whether to cancel reset, default = 0, yes; = 1, no 648 -|=(% style="width: 160px;" %)HSW1868|(% style="width:282px" %)Double-click or long press the record type table mode|(% style="width:452px" %)Controls whether the button pops up when double-clicking or long-clicking on a record-like form widget, default = 0, yes; = 1, no 649 649 |=(% style="width: 160px;" %)HSW10000~~19999|(% style="width:282px" %)Power-down storage area|(% style="width:452px" %)After restart, the data remains 650 650 |=(% style="width: 160px;" %)HSW10035|(% rowspan="13" style="width:282px" %)((( 651 651 **✎Note: **Only valid when the HMI is plugged into the Ethernet cable.