... ... @@ -4,11 +4,11 @@
4 4  
5 5  *HSW, HDW, HUW, HAW are word address, HSX, HDX, HUX, HAX are bit address.
6 6  
7 -1. **System data area (HSW): **A special register defined by the system.
8 -1. **Data storage area (HDW/HDX): **Users store user data.
9 -1. **System data area (HUW): **A special register defined by the system.
10 -1. **System Data (HAW)**: System register used for power-off save.
11 -1. **Recipe index area (RPW): **System register used for recipe index.
7 +* **System data area (HSW): **A special register defined by the system.
8 +* **Data storage area (HDW/HDX): **Users store user data.
9 +* **System data area (HUW): **A special register defined by the system.
10 +* **System Data (HAW)**: System register used for power-off save.
11 +* **Recipe index area (RPW): **System register used for recipe index.
12 12  
13 13  HMI internal registers are divided into bit address and word address, which can be accessed in two ways (take HDW as an example).
14 14  
... ... @@ -25,6 +25,19 @@
25 25  * The address of the bit address HDX is with a decimal point while word addresses are integers.
26 26  )))
27 27  
28 += Address ranges table =
29 +
30 +|=(% scope="row" style="width: 218px;" %)Address Type\HMI Series|=(% style="width: 228px;" %)General Series|=(% style="width: 200px;" %)i Series/HMI+ models|=(% style="width: 136px;" %)ie Series|=(% style="width: 232px;" %)ig Series
31 +|=(% style="width: 218px;" %)HDW|(% style="width:228px" %)HDW0-HDW299999|HDW0-HDW299999|HDW0-HDW299999|HDW0-HDW299999
32 +|=(% style="width: 218px;" %)HSW|(% style="width:228px" %)HSW0-HSW14999|HSW0-HSW14999|HSW0-HSW14999|HSW0-HSW14999
33 +|=(% style="width: 218px;" %)HAW|(% style="width:228px" %)HAW0-HAW199999|HAW0-HAW199999|HAW0-HAW199999|HAW0-HAW199999
34 +|=(% style="width: 218px;" %)HUW|(% style="width:228px" %)HUW0-HUW1599|HUW0-HUW1599|HUW0-HUW1599|HUW0-HUW1599
35 +|=(% style="width: 218px;" %)HDX|(% style="width:228px" %)HDX0.0-HDX299999.15|HDX0.0-HDX299999.15|HDX0.0-HDX299999.15|HDX0.0-HDX299999.15
36 +|=(% style="width: 218px;" %)HSX|(% style="width:228px" %)HSX0.0-HSX14999.15|HSX0.0-HSX14999.15|HSX0-HSX14999.15|HSX0.0-HSX14999.15
37 +|=(% style="width: 218px;" %)HAX|(% style="width:228px" %)HAX0.0-HAX199999.15|HAX0.0-HAX199999.15|HAX0.0-HAX199999.15|HAX0.0-HAX199999.15
38 +|=(% style="width: 218px;" %)HUX|(% style="width:228px" %)HUX0.0-HUX1599.15|HUX0.0-HUX1599.15|HUX0.0-HUX1599.15|HUX0.0-HUX1599.15
39 +|=(% style="width: 218px;" %)RPW|(% style="width:228px" %) |RPW000000-RPW990450|RPW000000-RPW990450|RPW000000-RPW990450
40 +
28 28  = **Data storage area (HDW/HDX)** =
29 29  
30 30  It is used to save the temporary data of project.
... ... @@ -241,8 +241,8 @@
241 241  * =2: HSX521.1=1, delete all trend graph.
242 242  * =4: HSX521.2=1, delete all alarms.
243 243  * =16: HSX521.4=1, delete history XY plot.
244 -* =32: HSX521.5=1, delete data records in SD card or flash dish;(Please make a setting which is saved to flash disk or SD card in project setting).
245 -* =64: HSX521.6=1, delete alarms records in SD card or flash dish; (Please make a setting which is saved to flash disk or SD card in project setting).
257 +* =32: HSX521.5=1, delete data records in SD card or USB flash disk;(Please make a setting which is saved to USB flash disk or SD card in project setting).
258 +* =64: HSX521.6=1, delete alarms records in SD card or USB flash disk; (Please make a setting which is saved to USB flash disk or SD card in project setting).
246 246  )))
247 247  |=(% style="width: 160px;" %)HSW522|(% style="width:282px" %)Copy and paste the alarm/data files in flash to the USB flash disk|(% style="width:452px" %)(((
248 248  * =0: No operation
... ... @@ -485,6 +485,8 @@
485 485  * =0, Default value
486 486  * =1, Release the alarm generated before the last power-down when starting up
487 487  )))
501 +|=(% style="width: 160px;" %)HSW1200|(% colspan="1" rowspan="2" style="width:282px" %)TSAP settings for HMI in the Siemens LOGO! 8 protocol(ig series or HMI V2.0)|(% style="width:452px" %)HMI local TSAP, which corresponds to the remote TSAP of PLC
502 +|=(% style="width: 160px;" %)HSW1201|(% style="width:452px" %)HMI remote TSAP, which corresponds to the local TSAP of PLC
488 488  |=(% style="width: 160px;" %)HSW1450|(% style="width:282px" %)Enable objects level password function|(% style="width:452px" %)(((
489 489  * =0, Disable
490 490  * =1, Enable
... ... @@ -591,6 +591,9 @@
591 591  * =0: Server connection exception
592 592  * =1: Server connection is OK
593 593  )))
609 +|=(% style="width: 160px;" %)HSW1740|(% style="width:282px" %)Wi-fi signal strength|(% style="width:452px" %)(((
610 +Display the value of Wi-fi signal signal strength, ranges from 0~~100 (Signal strength is automatically obtained only once when HMI is powered on, and it will not be automatically updated. It needs to be used with the HSW1890)
611 +)))
594 594  |=(% style="width: 160px;" %)HSW1741|(% colspan="1" rowspan="12" style="width:282px" %)Related IP register in 4Gnetwork status (It is valid when HMI is connected to 4G)|(% style="width:452px" %)Local IP address high byte 1
595 595  |=(% style="width: 160px;" %)HSW1742|(% style="width:452px" %)Local IP address high byte 2
596 596  |=(% style="width: 160px;" %)HSW1743|(% style="width:452px" %)Local IP address high byte 3
... ... @@ -618,10 +618,180 @@
618 618  * =1: Server connection is OK
619 619  )))
620 620  |=(% style="width: 160px;" %)HSW1761|(% style="width:282px" %)Display 4G network signal strength|(% style="width:452px" %)Signal strength: 0~~31. The greater the value ,the signal is stronger
639 +|=(% style="width: 160px;" %)(((
640 +HSW1762
641 +)))|(% colspan="1" rowspan="13" style="width:282px" %)(((
642 +Note: Valid when Ethernet2 of HMI is plugged into the network cable.
643 +①、When the Ethernet setting is enabled in the project parameters, this register displays the set value.
644 +②. When the Ethernet setting is not enabled in the engineering parameters, the register displays the Ethernet IP automatically acquired by the HMI.
645 +③. When the HMI is not plugged into the network cable, the register will show 0 whether the engineering parameters are set or not.
646 +④.IP related registers can be read and written (only static IP mode can be written).
647 +)))|(% style="width:452px" %)(((
648 +Ethernet2 Local IP address high byte 1
649 +)))
650 +|=(% style="width: 160px;" %)(((
651 +HSW1763
652 +)))|(% style="width:452px" %)(((
653 +Ethernet2 Local IP address high byte 2
654 +)))
655 +|=(% style="width: 160px;" %)(((
656 +HSW1764
657 +)))|(% style="width:452px" %)(((
658 +Ethernet2 Local IP address high byte 3
659 +)))
660 +|=(% style="width: 160px;" %)(((
661 +HSW1765
662 +)))|(% style="width:452px" %)(((
663 +Ethernet2 Local IP address high byte 4
664 +)))
665 +|=(% style="width: 160px;" %)(((
666 +HSW1766
667 +)))|(% style="width:452px" %)(((
668 +Ethernet2 Local mask IP address high byte 1
669 +)))
670 +|=(% style="width: 160px;" %)(((
671 +HSW1767
672 +)))|(% style="width:452px" %)(((
673 +Ethernet2 Local mask IP address high byte 2
674 +)))
675 +|=(% style="width: 160px;" %)(((
676 +HSW1768
677 +)))|(% style="width:452px" %)Ethernet2 Local mask IP address high byte 3
678 +|=(% style="width: 160px;" %)HSW1769|(% style="width:452px" %)Ethernet2 Local mask IP address high byte 4
679 +|=(% style="width: 160px;" %)(((
680 +HSW1770
681 +)))|(% style="width:452px" %)(((
682 +Ethernet2 Local gateway IP address high byte 1
683 +)))
684 +|=(% style="width: 160px;" %)(((
685 +HSW1771
686 +)))|(% style="width:452px" %)(((
687 +Ethernet2 Local gateway IP address high byte 2
688 +)))
689 +|=(% style="width: 160px;" %)(((
690 +HSW1772
691 +)))|(% style="width:452px" %)(((
692 +Ethernet2 Local gateway IP address high byte 3
693 +)))
694 +|=(% style="width: 160px;" %)(((
695 +HSW1773
696 +)))|(% style="width:452px" %)(((
697 +Ethernet2 Local gateway IP address high byte 4
698 +)))
699 +|=(% style="width: 160px;" %)(((
700 +HSW1774
701 +)))|(% style="width:452px" %)(((
702 +Ethernet2 Local Port Address
703 +)))
704 +|=(% style="width: 160px;" %)(((
705 +HSW1775
706 +)))|(% colspan="1" rowspan="6" style="width:282px" %)(((
707 +①Display the MAC code of Ethernet2 NIC
708 +
709 +(hexadecimal display)
710 +
711 +②Read-only mode, not modifiable
712 +)))|(% style="width:452px" %)(((
713 +Ethernet2 Local MAC code high byte 1
714 +)))
715 +|=(% style="width: 160px;" %)(((
716 +HSW1776
717 +)))|(% style="width:452px" %)(((
718 +Ethernet2 Local MAC code high byte 2
719 +)))
720 +|=(% style="width: 160px;" %)(((
721 +HSW1777
722 +)))|(% style="width:452px" %)(((
723 +Ethernet2 Local MAC code high byte 3
724 +)))
725 +|=(% style="width: 160px;" %)(((
726 +HSW1778
727 +)))|(% style="width:452px" %)(((
728 +Ethernet2 Local MAC code high byte 4
729 +)))
730 +|=(% style="width: 160px;" %)(((
731 +HSW1779
732 +)))|(% style="width:452px" %)(((
733 +Ethernet2 Local MAC code high byte 5
734 +)))
735 +|=(% style="width: 160px;" %)(((
736 +HSW1780
737 +)))|(% style="width:452px" %)(((
738 +Ethernet2 Local MAC code high byte 6
739 +)))
740 +|=(% style="width: 160px;" %)(((
741 +HSW1781
742 +)))|(% colspan="1" rowspan="8" style="width:282px" %)(((
743 +①Display and modify DNS1 and DNS2 of Ethernet2
744 +
745 +②Related registers can be read and written mode (only static IP mode can be written)
746 +)))|(% style="width:452px" %)(((
747 +Ethernet2 Local DNS1 address high byte 1
748 +)))
749 +|=(% style="width: 160px;" %)(((
750 +HSW1782
751 +)))|(% style="width:452px" %)(((
752 +Ethernet2 Local DNS1 address high byte 2
753 +)))
754 +|=(% style="width: 160px;" %)(((
755 +HSW1783
756 +)))|(% style="width:452px" %)(((
757 +Ethernet2 Local DNS1 address high byte 3
758 +)))
759 +|=(% style="width: 160px;" %)(((
760 +HSW1784
761 +)))|(% style="width:452px" %)(((
762 +Ethernet2 Local DNS1 address high byte 4
763 +)))
764 +|=(% style="width: 160px;" %)(((
765 +HSW1785
766 +)))|(% style="width:452px" %)(((
767 +Ethernet2 Local DNS2 address high byte 1
768 +)))
769 +|=(% style="width: 160px;" %)(((
770 +HSW1786
771 +)))|(% style="width:452px" %)(((
772 +Ethernet2 Local DNS2 address high byte 2
773 +)))
774 +|=(% style="width: 160px;" %)(((
775 +HSW1787
776 +)))|(% style="width:452px" %)(((
777 +Ethernet2 Local DNS2 address high byte 3
778 +)))
779 +|=(% style="width: 160px;" %)(((
780 +HSW1788
781 +)))|(% style="width:452px" %)(((
782 +Ethernet2 Local DNS2 address high byte 4
783 +)))
784 +|=(% style="width: 160px;" %)(((
785 +HSW1789
786 +)))|(% colspan="1" style="width:282px" %)(((
787 +Display or set the dynamic or static IP mode of Ethernet2
788 +)))|(% style="width:452px" %)(((
789 +HSX1789.0 = 0, Static IP mode
790 +
791 +HSX1789.0 = 1, dynamic IP mode
792 +)))
793 +|=(% style="width: 160px;" %)(((
794 +HSW1790
795 +)))|(% colspan="1" style="width:282px" %)(((
796 +Confirm Ethernet2 IP, subnet mask, gateway, DNS1, DNS2, and dynamic static IP settings
797 +)))|(% style="width:452px" %)(((
798 +~= 1, confirm the setting (i.e., after modifying IP-related information, set this address to 1, representing confirmation of the modification, after which it will be reset to 0)
799 +)))
800 +|=(% style="width: 160px;" %)(((
801 +HSW1791
802 +)))|(% colspan="1" style="width:282px" %)(((
803 +Network status of the Ethernet2 connection server
804 +)))|(% style="width:452px" %)(((
805 +~= 0, connection to the server is abnormal = 1, connection to the server is normal
806 +)))
621 621  |=(% style="width: 160px;" %)HSW1852|(% style="width:282px" %)Control the interval in two consecutive clicks|(% style="width:452px" %)Limit range: 1~~500ms. The default is 100 ms.
622 622  |=(% style="width: 160px;" %)HSW1853|(% style="width:282px" %)File format for exporting data records to USB flash drive or SD card|(% style="width:452px" %)(((
623 623  * =0: db database
624 624  * =1: CSV
811 +
812 +(Only valid for script function DbToCsvFile)
625 625  )))
626 626  |=(% style="width: 160px;" %)HSW1854|(% style="width:282px" %)High and low word conversion type|(% style="width:452px" %)(((
627 627  * =0: use the old high-low word conversion (default)
... ... @@ -643,30 +643,96 @@
643 643  * =1: download firmware
644 644  * =2: enter the background
645 645  )))
646 -|=(% style="width: 160px;" %)HSW1866|(% style="width:282px" %)Delete the LUa extension module file|(% style="width:452px" %)(((
647 -* =1, delete;
648 -* = Others, do not delete
834 +|=(% style="width: 160px;" %)HSW1865|(% style="width:282px" %)Priority connection to the cloud|(% style="width:452px" %)(((
835 +* =0: priority Ethernet
836 +* =1: priority WLAN
837 +* =2: priority 4G
649 649  )))
839 +|=(% style="width: 160px;" %)HSW1866|(% style="width:282px" %)Delete the Lua extension module file|(% style="width:452px" %)(((
840 +* =0: delete;
841 +* = Others: do not delete
842 +)))
650 650  |=(% style="width: 160px;" %)HSW1867|(% style="width:282px" %)Reset mode|(% style="width:452px" %)(((
651 651  Monitor address is set during reset of reset switch, whether to cancel reset,
652 652  
653 -* = 0, yes (default);
654 -* = 1, no
846 +* = 0: yes (default);
847 +* = 1: no
655 655  )))
656 656  |=(% style="width: 160px;" %)HSW1868|(% style="width:282px" %)Double-click or long press the record type table mode|(% style="width:452px" %)(((
657 657  Controls whether the button pops up when double-clicking or long pressing on record type table object
658 658  
659 -* = 0, yes (default);
660 -* = 1, no
852 +* = 0: yes (default);
853 +* = 1: no
661 661  )))
855 +|=(% style="width: 160px;" %)(((
856 +HSW1869
857 +)))|(% style="width:282px" %)(((
858 +Dynamic screensaver countdown
859 +)))|(% style="width:452px" %)(((
860 +Countdown to enter dynamic screensaver effect, unit (S)
861 +)))
862 +|=(% style="width: 160px;" %)(((
863 +HSW1870
864 +)))|(% style="width:282px" %)(((
865 +Display or set the dynamic or static IP mode of Ethernet1
866 +)))|(% style="width:452px" %)(((
867 +HSX1870.0 = 0, Static IP mode
868 +
869 +HSX1870.0 = 1, dynamic IP mode
870 +)))
871 +|=(% style="width: 160px;" %)(((
872 +HSW1871
873 +)))|(% style="width:282px" %)(((
874 +Confirm the IP, subnet mask, gateway, DNS1, DNS2, and dynamic static IP settings for Ethernet1
875 +)))|(% style="width:452px" %)(((
876 +~= 1, confirm the setting (i.e., after modifying IP-related information, set this address to 1, representing confirmation of the modification, after which it will be reset to 0)
877 +)))
878 +|=(% style="width: 160px;" %)(((
879 +HSW1872
880 +)))|(% colspan="1" rowspan="8" style="width:282px" %)(((
881 +①Display and modify DNS1 and DNS2 of Ethernet1
882 +
883 +②Related registers can be read and written mode (only static IP mode can be written)
884 +)))|(% style="width:452px" %)(((
885 +Ethernet1 Local DNS1 address high byte 1
886 +)))
887 +|=(% style="width: 160px;" %)(((
888 +HSW1873
889 +)))|(% style="width:452px" %)Ethernet1 Local DNS1 address high byte 2
890 +|=(% style="width: 160px;" %)(((
891 +HSW1874
892 +)))|(% style="width:452px" %)Ethernet1 Local DNS1 address high byte 3
893 +|=(% style="width: 160px;" %)(((
894 +HSW1875
895 +)))|(% style="width:452px" %)Ethernet1 Local DNS1 address high byte 4
896 +|=(% style="width: 160px;" %)(((
897 +HSW1876
898 +)))|(% style="width:452px" %)Ethernet1 Local DNS2 address high byte 1
899 +|=(% style="width: 160px;" %)(((
900 +HSW1877
901 +)))|(% style="width:452px" %)Ethernet1 Local DNS2 address high byte 2
902 +|=(% style="width: 160px;" %)(((
903 +HSW1878
904 +)))|(% style="width:452px" %)Ethernet1 Local DNS2 address high byte 3
905 +|=(% style="width: 160px;" %)(((
906 +HSW1879
907 +)))|(% style="width:452px" %)Ethernet1 Local DNS2 address high byte 4
908 +|=(% style="width: 160px;" %)HSW1890|(% colspan="1" style="width:282px" %)Enable refresh current network signal|(% style="width:452px" %)(((
909 +* =1: Refresh the network signal once after triggered (This register will be automatically reset after triggered, only update the signal value once after per 15 seconds, not able to update twice in the short interval)
910 +* =Others: not refresh
911 +)))
912 +|=(% style="width: 160px;" %)HSW1891|(% colspan="1" style="width:282px" %)Enable clear cache for screen data  |(% style="width:452px" %)(((
913 +* =1, not clear screen cache when switch language
914 +* =2, trigger clear cache of all screens for once time
915 +* =3, always clear cache of all screen data
916 +)))
662 662  |=(% style="width: 160px;" %)HSW10000~~19999|(% style="width:282px" %)Power-down storage area|(% style="width:452px" %)After restart, the data remains
663 663  |=(% style="width: 160px;" %)HSW10035|(% rowspan="13" style="width:282px" %)(((
664 -**✎Note: **Only valid when the HMI is plugged into the Ethernet cable.
665 -
666 -1. If Ethernet settings is enabled in project parameters, this register displays the set value.
667 -1. If Ethernet settings is not enabled in project parameters, IP would automatically obtained IP.
668 -1. If HMI is not connected to the network, the register is displayed as 0 whether the engineering parameters are set.
669 -1. 4. All IP registers of HMI are read-only.
919 +Note: Valid when Ethernet1 of HMI is plugged into the network cable.
920 +①、When the Ethernet setting is enabled in the project parameters, this register displays the set value.
921 +②. When the Ethernet setting is not enabled in the engineering parameters, the register displays the Ethernet IP automatically acquired by the HMI.
922 +③. When the HMI is not plugged into the network cable, the register will show 0 whether the engineering parameters are set or not.
923 +④.IP related registers can be read and written (only static IP mode can be written).
670 670  )))|(% style="width:452px" %)Local IP address high byte 1
671 671  |=(% style="width: 160px;" %)HSW10036|(% style="width:452px" %)Local IP address high byte 2
672 672  |=(% style="width: 160px;" %)HSW10037|(% style="width:452px" %)Local IP address high byte 3
... ... @@ -681,9 +681,11 @@
681 681  |=(% style="width: 160px;" %)HSW10046|(% style="width:452px" %)Local gateway address high byte 4
682 682  |=(% style="width: 160px;" %)HSW10047|(% style="width:452px" %)Local port address
683 683  |=(% style="width: 160px;" %)HSW10048|(% rowspan="6" style="width:282px" %)(((
684 -Displays the MAC code of the current network card
938 +Display the MAC code of Ethernet1 NIC
685 685  
686 -(Hexadecimal display)
940 +(hexadecimal display)
941 +
942 +②Read-only mode, not modifiable
687 687  )))|(% style="width:452px" %)Local MAC code high word 1
688 688  |=(% style="width: 160px;" %)HSW10049|(% style="width:452px" %)Local MAC code high word 2
689 689  |=(% style="width: 160px;" %)HSW10050|(% style="width:452px" %)Local MAC code high word 3
... ... @@ -690,7 +690,7 @@
690 690  |=(% style="width: 160px;" %)HSW10051|(% style="width:452px" %)Local MAC code high word 4
691 691  |=(% style="width: 160px;" %)HSW10052|(% style="width:452px" %)Local MAC code high word 5
692 692  |=(% style="width: 160px;" %)HSW10053|(% style="width:452px" %)Local MAC code high word 6
693 -|=(% style="width: 160px;" %)HSW10118|(% colspan="1" rowspan="2" style="width:282px" %)TSAP settings for HMI in the Siemens logo! 8 protocol|(% style="width:452px" %)HMI local TSAP, which corresponds to the remote TSAP of PLC
949 +|=(% style="width: 160px;" %)HSW10118|(% colspan="1" rowspan="2" style="width:282px" %)TSAP settings for HMI in the Siemens LOGO! 8 protocol|(% style="width:452px" %)HMI local TSAP, which corresponds to the remote TSAP of PLC
694 694  |=(% style="width: 160px;" %)HSW10119|(% style="width:452px" %)HMI remote TSAP, which corresponds to the local TSAP of PLC
695 695  |=(% style="width: 160px;" %)HSW10461~~10493|(% style="width:282px" %)Remote access password|(% style="width:452px" %)8-character remote access password
696 696  |=(% style="width: 160px;" %)HSW10494~~10558|(% style="width:282px" %)Machine ID (Read only)|(% style="width:452px" %)Machine ID for remote access (read only 64-bit)
... ... @@ -772,11 +772,38 @@
772 772  )))
773 773  |=(% style="width: 160px;" %)HSW11760|(% style="width:282px" %)Screensaver countdown|(% style="width:452px" %)Display the countdown to enter the Screensaver, unit: second.
774 774  |=(% style="width: 160px;" %)HSW11761|(% style="width:282px" %)Screensaver screen number|(% style="width:452px" %)Set the screen number for Screensaver
1031 +|=(% style="width: 160px;" %)(((
1032 +HSW11762
1033 +)))|(% style="width:282px" %)(((
1034 +Dynamic screensaver control address
1035 +)))|(% style="width:452px" %)(((
1036 +HSX11762.0=0, initialize with project configuration;
775 775  
776 -== **Serial port communication configuration** ==
1038 +HSX11762.0=1, initialize with special register configuration;
777 777  
1040 +HSX11762.1=0, disable dynamic screensaver;
1041 +
1042 +HSX11762.1=1, enable dynamic screensaver
1043 +)))
1044 +|=(% style="width: 160px;" %)(((
1045 +HSW11763
1046 +)))|(% style="width:282px" %)(((
1047 +Waiting time to enter the dynamic screensaver
1048 +)))|(% style="width:452px" %)(((
1049 +Waiting time when the screen is not operated, range 1~~720 minutes
1050 +)))
1051 +|=(% style="width: 160px;" %)(((
1052 +HSW11764
1053 +)))|(% style="width:282px" %)(((
1054 +Animated screensaver animation type
1055 +)))|(% style="width:452px" %)(((
1056 +~=0: Raster,=1: Blinds,=2: Bubble
1057 +)))
1058 +
1059 +== Serial port communication configuration ==
1060 +
778 778  (% class="table-bordered" %)
779 -|=(% style="width: 102px;" %)Port|=(% style="width: 173px;" %)**Function**|=(% style="width: 122px;" %)**Address**|=(% colspan="2" style="width: 506px;" %)**Description**
1062 +|=(% scope="row" style="width: 102px;" %)Port|=(% style="width: 173px;" %)**Function**|=(% style="width: 122px;" %)**Address**|=(% colspan="2" style="width: 506px;" %)**Description**
780 780  |(% colspan="1" rowspan="11" style="width:102px" %)COM1|(% style="width:173px" %)Communication mode|(% style="width:122px" %)HSW10061|(% colspan="2" style="width:506px" %)(((
781 781  * =0: RS232
782 782  * =1: RS485
... ... @@ -806,10 +806,22 @@
806 806  * =1: ODD
807 807  * =2: EVEN
808 808  )))
809 -|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10066|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000
810 -|(% style="width:173px" %)reveive timeout|(% style="width:122px" %)HSW10067|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000
811 -|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10068|(% colspan="2" style="width:506px" %)Unit: times. Range: 0~~100
812 -|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10069|(% colspan="2" style="width:506px" %)Unit: s. Range: 0~~300
1092 +|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10066|(% colspan="2" style="width:506px" %)(((
1093 +* Unit: ms.
1094 +* Range: 0 to 30000
1095 +)))
1096 +|(% style="width:173px" %)reveive timeout|(% style="width:122px" %)HSW10067|(% colspan="2" style="width:506px" %)(((
1097 +* Unit: ms.
1098 +* Range: 0 to 30000
1099 +)))
1100 +|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10068|(% colspan="2" style="width:506px" %)(((
1101 +* Unit: times.
1102 +* Range: 0 to 100
1103 +)))
1104 +|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10069|(% colspan="2" style="width:506px" %)(((
1105 +* Unit: s.
1106 +* Range: 0 to 300
1107 +)))
813 813  |(% style="width:173px" %)HMI station number|(% style="width:122px" %)HSW10070|(% colspan="2" style="width:506px" %)
814 814  |(% style="width:173px" %)PLC station number|(% style="width:122px" %)HSW10071|(% colspan="2" style="width:506px" %)
815 815  |(% colspan="1" rowspan="11" style="width:102px" %)COM1-2|(% style="width:173px" %)Communication mode|(% style="width:122px" %)HSW10094|(% colspan="2" style="width:506px" %)(((
... ... @@ -842,10 +842,22 @@
842 842  * =1: ODD
843 843  * =2: EVEN
844 844  )))
845 -|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10099|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000
846 -|(% style="width:173px" %)receive timeout|(% style="width:122px" %)HSW10100|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000
847 -|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10101|(% colspan="2" style="width:506px" %)Unit: times. Range: 0~~100
848 -|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10102|(% colspan="2" style="width:506px" %)Unit: s. Range: 0~~30
1140 +|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10099|(% colspan="2" style="width:506px" %)(((
1141 +* Unit: ms.
1142 +* Range: 0 to 30000
1143 +)))
1144 +|(% style="width:173px" %)receive timeout|(% style="width:122px" %)HSW10100|(% colspan="2" style="width:506px" %)(((
1145 +* Unit: ms.
1146 +* Range: 0 to 30000
1147 +)))
1148 +|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10101|(% colspan="2" style="width:506px" %)(((
1149 +* Unit: times.
1150 +* Range: 0 to 100
1151 +)))
1152 +|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10102|(% colspan="2" style="width:506px" %)(((
1153 +* Unit: s.
1154 +* Range: 0 to 30
1155 +)))
849 849  |(% style="width:173px" %)HMI station number|(% style="width:122px" %)HSW10103|(% colspan="2" style="width:506px" %)
850 850  |(% style="width:173px" %)PLC station number|(% style="width:122px" %)HSW10104|(% colspan="2" style="width:506px" %)
851 851  |(% colspan="1" rowspan="11" style="width:102px" %)COM1-3|(% style="width:173px" %)Communication mode|(% style="width:122px" %)HSW10120|(% colspan="2" style="width:506px" %)(((
... ... @@ -878,10 +878,22 @@
878 878  * =1: ODD
879 879  * =2: EVEN
880 880  )))
881 -|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10125|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000
882 -|(% style="width:173px" %)receive timeout|(% style="width:122px" %)HSW10126|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000
883 -|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10127|(% colspan="2" style="width:506px" %)Unit: times. Range: 0~~100
884 -|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10128|(% colspan="2" style="width:506px" %)Unit: s. Range: 0~~30
1188 +|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10125|(% colspan="2" style="width:506px" %)(((
1189 +* Unit: ms.
1190 +* Range: 0 to 30000
1191 +)))
1192 +|(% style="width:173px" %)receive timeout|(% style="width:122px" %)HSW10126|(% colspan="2" style="width:506px" %)(((
1193 +* Unit: ms.
1194 +* Range: 0 to 30000
1195 +)))
1196 +|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10127|(% colspan="2" style="width:506px" %)(((
1197 +* Unit: times.
1198 +* Range: 0 to 100
1199 +)))
1200 +|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10128|(% colspan="2" style="width:506px" %)(((
1201 +* Unit: s.
1202 +* Range: 0 to 30
1203 +)))
885 885  |(% style="width:173px" %)HMI station number|(% style="width:122px" %)HSW10129|(% colspan="2" style="width:506px" %)
886 886  |(% style="width:173px" %)PLC station number|(% style="width:122px" %)HSW10130|(% colspan="2" style="width:506px" %)
887 887  |(% colspan="1" rowspan="11" style="width:102px" %)COM2|(% style="width:173px" %)Communication mode|(% style="width:122px" %)HSW10072|(% colspan="2" style="width:506px" %)(((
... ... @@ -912,10 +912,22 @@
912 912  * =1: ODD
913 913  * =2: EVEN
914 914  )))
915 -|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10077|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000
916 -|(% style="width:173px" %)receive timeout|(% style="width:122px" %)HSW10078|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000
917 -|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10079|(% colspan="2" style="width:506px" %)Unit: times. Range: 0~~100
918 -|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10080|(% colspan="2" style="width:506px" %)Unit: s. Range: 0~~30
1234 +|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10077|(% colspan="2" style="width:506px" %)(((
1235 +* Unit: ms.
1236 +* Range: 0 to 30000
1237 +)))
1238 +|(% style="width:173px" %)receive timeout|(% style="width:122px" %)HSW10078|(% colspan="2" style="width:506px" %)(((
1239 +* Unit: ms.
1240 +* Range: 0 to 30000
1241 +)))
1242 +|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10079|(% colspan="2" style="width:506px" %)(((
1243 +* Unit: times.
1244 +* Range: 0 to 100
1245 +)))
1246 +|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10080|(% colspan="2" style="width:506px" %)(((
1247 +* Unit: s.
1248 +* Range: 0 to 30
1249 +)))
919 919  |(% style="width:173px" %)HMI station number|(% style="width:122px" %)HSW10081|(% colspan="2" style="width:506px" %)
920 920  |(% style="width:173px" %)PLC station number|(% style="width:122px" %)HSW10082|(% colspan="2" style="width:506px" %)
921 921  |(% colspan="1" rowspan="11" style="width:102px" %)COM2-2|(% style="width:173px" %)Communication mode|(% style="width:122px" %)HSW10105|(% colspan="2" style="width:506px" %)(((
... ... @@ -946,10 +946,22 @@
946 946  * =1: ODD
947 947  * =2: EVEN
948 948  )))
949 -|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10110|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000
950 -|(% style="width:173px" %)receive timeout|(% style="width:122px" %)HSW10111|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000
951 -|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10112|(% colspan="2" style="width:506px" %)Unit: times. Range: 0~~100
952 -|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10113|(% colspan="2" style="width:506px" %)Unit: s. Range: 0~~30
1280 +|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10110|(% colspan="2" style="width:506px" %)(((
1281 +* Unit: ms.
1282 +* Range: 0 to 30000
1283 +)))
1284 +|(% style="width:173px" %)receive timeout|(% style="width:122px" %)HSW10111|(% colspan="2" style="width:506px" %)(((
1285 +* Unit: ms.
1286 +* Range: 0 to 30000
1287 +)))
1288 +|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10112|(% colspan="2" style="width:506px" %)(((
1289 +* Unit: times.
1290 +* Range: 0 to 100
1291 +)))
1292 +|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10113|(% colspan="2" style="width:506px" %)(((
1293 +* Unit: s.
1294 +* Range: 0 to 30
1295 +)))
953 953  |(% style="width:173px" %)HMI station number|(% style="width:122px" %)HSW10114|(% colspan="2" style="width:506px" %)
954 954  |(% style="width:173px" %)PLC station number|(% style="width:122px" %)HSW10115|(% colspan="2" style="width:506px" %)
955 955  |(% colspan="1" rowspan="11" style="width:102px" %)COM3|(% style="width:173px" %)Communication mode|(% style="width:122px" %)HSW10083|(% colspan="2" style="width:506px" %)(((
... ... @@ -979,29 +979,48 @@
979 979  * =1: ODD
980 980  * =2: EVEN
981 981  )))
982 -|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10088|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000
983 -|(% style="width:173px" %)receive timeout|(% style="width:122px" %)HSW10089|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000
984 -|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10090|(% colspan="2" style="width:506px" %)Unit: times. Range: 0~~100
985 -|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10091|(% colspan="2" style="width:506px" %)Unit: s. Range: 0~~30
1325 +|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10088|(% colspan="2" style="width:506px" %)(((
1326 +* Unit: ms.
1327 +* Range: 0 to 30000
1328 +)))
1329 +|(% style="width:173px" %)receive timeout|(% style="width:122px" %)HSW10089|(% colspan="2" style="width:506px" %)(((
1330 +* Unit: ms.
1331 +* Range: 0 to 30000
1332 +)))
1333 +|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10090|(% colspan="2" style="width:506px" %)(((
1334 +* Unit: times.
1335 +* Range: 0 to 100
1336 +)))
1337 +|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10091|(% colspan="2" style="width:506px" %)(((
1338 +* Unit: s.
1339 +* Range: 0 to 30
1340 +)))
986 986  |(% style="width:173px" %)HMI station number|(% style="width:122px" %)HSW10092|(% colspan="2" style="width:506px" %)
987 987  |(% style="width:173px" %)PLC station number|(% style="width:122px" %)HSW10093|(% colspan="2" style="width:506px" %)
988 988  |(% colspan="1" rowspan="2" style="width:102px" %)CAN port|(% style="width:173px" %)CAN1 baud rate|(% style="width:122px" %)HSW010116|(% style="width:299px" %)(((
989 -Unit: K, the baud rate must be an integer, for example, when the baud rate required is 250000, just enter 250.
1344 +Unit: K, the baud rate must be an integer.
1345 +
1346 +For example, when the baud rate required is 250000, just enter 250.
990 990  )))|(% colspan="1" rowspan="2" style="width:218px" %)**✎Note: **If baud rate has been modified,please wait 5 seconds,then restart the HMI to take effect.
991 -|(% style="width:173px" %)CAN2 baud rate|(% style="width:122px" %)HSW010117|(% style="width:299px" %)Unit: K, the baud rate must be an integer, for example, when the baud rate required is 250000, just enter 250.
1348 +|(% style="width:173px" %)CAN2 baud rate|(% style="width:122px" %)HSW010117|(% style="width:299px" %)(((
1349 +Unit: K, the baud rate must be an integer.
992 992  
993 -== **Ethernet communication configuration** ==
1351 +For example, when the baud rate required is 250000, just enter 250.
1352 +)))
994 994  
1354 +== Ethernet communication configuration ==
1355 +
995 995  (% class="table-bordered" %)
996 -|=(% style="width: 40px;" %)**No.**|=(% style="width: 295px;" %)**Function**|=(% style="width: 220px;" %)**Address**|=(% style="width: 336px;" %)**Description**
1357 +|(% style="width:40px" %)**No.**|(% style="width:295px" %)**Function**|(% style="width:220px" %)**Address**|(% style="width:336px" %)**Description**
997 997  |(% rowspan="7" style="width:40px" %)1|(% colspan="1" rowspan="7" style="width:295px" %)Ethernet parameter configuration for communication number 1 in list. Configure those addresses according to connected device. After configuration, wait for 5 seconds and restart the HMI.|(% style="width:220px" %)HSW11004|(% style="width:336px" %)Device IP address high word 1
998 998  |(% style="width:220px" %)HSW11005|(% style="width:336px" %)Device IP address high word 2
999 999  |(% style="width:220px" %)HSW11006|(% style="width:336px" %)Device IP address high word 3
1000 1000  |(% style="width:220px" %)HSW11007|(% style="width:336px" %)Device IP address high word 4
1001 1001  |(% style="width:220px" %)HSW11008|(% style="width:336px" %)Device Port number
1002 -|(% style="width:220px" %)HSW11009|=(% style="width: 336px;" %)(((
1003 -* =2 TCP
1004 -* =3 UDP
1363 +|(% style="width:220px" %)HSW11009|(% style="width:336px" %)(((
1364 +~=2 TCP
1365 +
1366 +~=3 UDP
1005 1005  )))
1006 1006  |(% style="width:220px" %)HSW11010|(% style="width:336px" %)Reserved
1007 1007  |(% rowspan="7" style="width:40px" %)2|(% colspan="1" rowspan="7" style="width:295px" %)Ethernet parameter configuration for communication number 2 in list. Configure those addresses according to connected device. After configuration, wait for 5 seconds and restart the HMI.|(% style="width:220px" %)HSW11011|(% style="width:336px" %)Device IP address high word 1
... ... @@ -1009,9 +1009,10 @@
1009 1009  |(% style="width:220px" %)HSW11013|(% style="width:336px" %)Device IP address high word 3
1010 1010  |(% style="width:220px" %)HSW11014|(% style="width:336px" %)Device IP address high word 4
1011 1011  |(% style="width:220px" %)HSW11015|(% style="width:336px" %)Device Port number
1012 -|(% style="width:220px" %)HSW11016|=(% style="width: 336px;" %)(((
1013 -* =2 TCP
1014 -* =3 UDP
1374 +|(% style="width:220px" %)HSW11016|(% style="width:336px" %)(((
1375 +~=2 TCP
1376 +
1377 +~=3 UDP
1015 1015  )))
1016 1016  |(% style="width:220px" %)HSW11017|(% style="width:336px" %)Reserved
1017 1017  |(% style="width:40px" %)…|(% style="width:295px" %) |(% style="width:220px" %)…|(% style="width:336px" %)…
... ... @@ -1020,7 +1020,11 @@
1020 1020  |(% style="width:220px" %)HSW11223|(% style="width:336px" %)Device IP address high word 3
1021 1021  |(% style="width:220px" %)HSW11224|(% style="width:336px" %)Device IP address high word 4
1022 1022  |(% style="width:220px" %)HSW11225|(% style="width:336px" %)Device Port number
1023 -|(% style="width:220px" %)HSW11226|=(% style="width: 336px;" %)2 TCP; =3 UDP
1386 +|(% style="width:220px" %)HSW11226|(% style="width:336px" %)(((
1387 +~=2 TCP;
1388 +
1389 +~=3 UDP
1390 +)))
1024 1024  |(% style="width:220px" %)HSW11227|(% style="width:336px" %)Reserved
1025 1025  
1026 1026  (% class="box infomessage" %)
... ... @@ -1028,7 +1028,7 @@
1028 1028  **✎Note:** The number of Ethernet connections supported by different HMI series varies.