Changes for page 13 HMI Internal Registers

Last modified by Jett on 2025/04/28 16:07

From version 4.6
edited by Stone Wu
on 2022/08/06 14:21
Change comment: There is no comment for this version
To version 3.1
edited by Stone Wu
on 2022/08/03 10:03
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -339,11 +339,9 @@
339 339  * HDX882.1=0 SD card doesn't execute storage or storage finished.
340 340  * HDX882.1=1 SD card is reading data, don't remove SD card.
341 341  )))
342 -|=(% style="width: 160px;" %)HSW884|(% style="width:282px" %)Enter the system network configuration interface|(% style="width:452px" %)(((
343 -* =0: Do not enter the network configuration interface
344 -* =1: Enter the system network configuration interface.
345 -** ig series HMI only supports to enter the system interface
346 -
342 +|=(% style="width: 160px;" %)HSW884|(% style="width:282px" %)Enter setup screen|(% style="width:452px" %)(((
343 +* = 0: Do not into setup screen
344 +* = 1: Enter setup screen
347 347  )))
348 348  |=(% style="width: 160px;" %)HSW885|(% style="width:282px" %)When the control object hides the address is read failed (communication failure), set the display mode of the object|(% style="width:452px" %)(((
349 349  * = 0: displayed by object setting.
... ... @@ -512,10 +512,6 @@
512 512  * HSX1502.0=1: Modification comfirmed. Save the data of HSW1450~~HSW1501 to a file for immediate effect.
513 513  * HSX1502.1=1:Modification cancelled. Restore the current data of hSW1450-HSW1501 to the data saved in the file last time.
514 514  )))
515 -|=(% style="width: 160px;" %)HSW1509|(% style="width:282px" %)Curve width|(% style="width:452px" %)(((
516 -* =0: Use the curve width set by project default.
517 -* =1 to 10: use special register to set curve width.
518 -)))
519 519  |=(% style="width: 160px;" %)HSW1603|(% style="width:282px" %)Number of current unreleased alarms|(% style="width:452px" %)The number of current unreleased alarms in alarm record file.
520 520  |=(% style="width: 160px;" %)HSW1604|(% style="width:282px" %)The auxiliary judgment address when the control bit in the Object Lock fails to be read|(% style="width:452px" %)(((
521 521  * =0: The auxiliary address is invalid.
... ... @@ -643,22 +643,6 @@
643 643  * =1: download firmware
644 644  * =2: enter the background
645 645  )))
646 -|=(% style="width: 160px;" %)HSW1866|(% style="width:282px" %)Delete the LUa extension module file|(% style="width:452px" %)(((
647 -* =1, delete;
648 -* = Others, do not delete
649 -)))
650 -|=(% style="width: 160px;" %)HSW1867|(% style="width:282px" %)Reset mode|(% style="width:452px" %)(((
651 -Monitor address is set during reset of reset switch, whether to cancel reset,
652 -
653 -* = 0, yes (default);
654 -* = 1, no
655 -)))
656 -|=(% style="width: 160px;" %)HSW1868|(% style="width:282px" %)Double-click or long press the record type table mode|(% style="width:452px" %)(((
657 -Controls whether the button pops up when double-clicking or long pressing on record type table object
658 -
659 -* = 0, yes (default);
660 -* = 1, no
661 -)))
662 662  |=(% style="width: 160px;" %)HSW10000~~19999|(% style="width:282px" %)Power-down storage area|(% style="width:452px" %)After restart, the data remains
663 663  |=(% style="width: 160px;" %)HSW10035|(% rowspan="13" style="width:282px" %)(((
664 664  **✎Note: **Only valid when the HMI is plugged into the Ethernet cable.
... ... @@ -1031,7 +1031,7 @@
1031 1031  == **Communication control** ==
1032 1032  
1033 1033  (% class="table-bordered" %)
1034 -|=(% style="width: 135px;" %)**Communication No.**|=(% style="width: 102px;" %)**Station No.**|=(% style="width: 185px;" %)**Control bit**|=(% style="width: 191px;" %)**Communication lamp**|=(% style="width: 271px;" %)**Description**
1012 +|(% style="width:135px" %)**Communication No.**|(% style="width:102px" %)**Station No.**|(% style="width:185px" %)**Control bit**|(% style="width:191px" %)**Communication lamp**|(% style="width:271px" %)**Description**
1035 1035  |(% colspan="1" rowspan="16" style="width:135px" %)1|(% style="width:102px" %)0~~15|(% style="width:185px" %)HSX550.0~HSX550.15|(% style="width:191px" %)HSX558.0~HSX558.15|(% rowspan="160" style="width:271px" %)Communication number refers to the number in "Communication Port Configuration". A number provides 256 device station numbers. Each station number corresponds to a communication control bit and a communication indicator bit. Registers HSX550.0 to HSX805.15 are used to control the station numbers from 0 to 127, and registers HSX1150.0 to HSX1405.15 are used to control station numbers 128 to 255.
1036 1036  |(% style="width:102px" %)16~~31|(% style="width:185px" %)HSX551.0~HSX551.15|(% style="width:191px" %)HSX559.0~HSX559.15
1037 1037  |(% style="width:102px" %)32~~47|(% style="width:185px" %)HSX552.0~HSX552.15|(% style="width:191px" %)HSX560.0~HSX560.15