5 5  *HSW, HDW, HUW, HAW are word address, HSX, HDX, HUX, HAX are bit address.
6 6  
7 -1. **System data area (HSW): **A special register defined by the system.
8 -1. **Data storage area (HDW/HDX): **Users store user data.
9 -1. **System data area (HUW): **A special register defined by the system.
10 -1. **System Data (HAW)**: System register used for power-off save.
11 -1. **Recipe index area (RPW): **System register used for recipe index.
7 +* **System data area (HSW): **A special register defined by the system.
8 +* **Data storage area (HDW/HDX): **Users store user data.
9 +* **System data area (HUW): **A special register defined by the system.
10 +* **System Data (HAW)**: System register used for power-off save.
11 +* **Recipe index area (RPW): **System register used for recipe index.
12 12  
13 13  HMI internal registers are divided into bit address and word address, which can be accessed in two ways (take HDW as an example).
14 14  
... ... @@ -618,6 +618,174 @@
618 618  * =1: Server connection is OK
619 619  )))
620 620  |=(% style="width: 160px;" %)HSW1761|(% style="width:282px" %)Display 4G network signal strength|(% style="width:452px" %)Signal strength: 0~~31. The greater the value ,the signal is stronger
621 +|=(% style="width: 160px;" %)(((
622 +HSW1762
623 +)))|(% colspan="1" rowspan="13" style="width:282px" %)(((
624 +Note: Valid when Ethernet2 of HMI is plugged into the network cable.
625 +①、When the Ethernet setting is enabled in the project parameters, this register displays the set value.
626 +②. When the Ethernet setting is not enabled in the engineering parameters, the register displays the Ethernet IP automatically acquired by the HMI.
627 +③. When the HMI is not plugged into the network cable, the register will show 0 whether the engineering parameters are set or not.
628 +④.IP related registers can be read and written (only static IP mode can be written).
629 +)))|(% style="width:452px" %)(((
630 +Ethernet2 Local IP address high byte 1
631 +)))
632 +|=(% style="width: 160px;" %)(((
633 +HSW1763
634 +)))|(% style="width:452px" %)(((
635 +Ethernet2 Local IP address high byte 2
636 +)))
637 +|=(% style="width: 160px;" %)(((
638 +HSW1764
639 +)))|(% style="width:452px" %)(((
640 +Ethernet2 Local IP address high byte 3
641 +)))
642 +|=(% style="width: 160px;" %)(((
643 +HSW1765
644 +)))|(% style="width:452px" %)(((
645 +Ethernet2 Local IP address high byte 4
646 +)))
647 +|=(% style="width: 160px;" %)(((
648 +HSW1766
649 +)))|(% style="width:452px" %)(((
650 +Ethernet2 Local mask IP address high byte 1
651 +)))
652 +|=(% style="width: 160px;" %)(((
653 +HSW1767
654 +)))|(% style="width:452px" %)(((
655 +Ethernet2 Local mask IP address high byte 2
656 +)))
657 +|=(% style="width: 160px;" %)(((
658 +HSW1768
659 +)))|(% style="width:452px" %)Ethernet2 Local mask IP address high byte 3
660 +|=(% style="width: 160px;" %)HSW1769|(% style="width:452px" %)Ethernet2 Local mask IP address high byte 4
661 +|=(% style="width: 160px;" %)(((
662 +HSW1770
663 +)))|(% style="width:452px" %)(((
664 +Ethernet2 Local gateway IP address high byte 1
665 +)))
666 +|=(% style="width: 160px;" %)(((
667 +HSW1771
668 +)))|(% style="width:452px" %)(((
669 +Ethernet2 Local gateway IP address high byte 2
670 +)))
671 +|=(% style="width: 160px;" %)(((
672 +HSW1772
673 +)))|(% style="width:452px" %)(((
674 +Ethernet2 Local gateway IP address high byte 3
675 +)))
676 +|=(% style="width: 160px;" %)(((
677 +HSW1773
678 +)))|(% style="width:452px" %)(((
679 +Ethernet2 Local gateway IP address high byte 4
680 +)))
681 +|=(% style="width: 160px;" %)(((
682 +HSW1774
683 +)))|(% style="width:452px" %)(((
684 +Ethernet2 Local Port Address
685 +)))
686 +|=(% style="width: 160px;" %)(((
687 +HSW1775
688 +)))|(% colspan="1" rowspan="6" style="width:282px" %)(((
689 +①Display the MAC code of Ethernet2 NIC
690 +
691 +(hexadecimal display)
692 +
693 +②Read-only mode, not modifiable
694 +)))|(% style="width:452px" %)(((
695 +Ethernet2 Local MAC code high byte 1
696 +)))
697 +|=(% style="width: 160px;" %)(((
698 +HSW1776
699 +)))|(% style="width:452px" %)(((
700 +Ethernet2 Local MAC code high byte 2
701 +)))
702 +|=(% style="width: 160px;" %)(((
703 +HSW1777
704 +)))|(% style="width:452px" %)(((
705 +Ethernet2 Local MAC code high byte 3
706 +)))
707 +|=(% style="width: 160px;" %)(((
708 +HSW1778
709 +)))|(% style="width:452px" %)(((
710 +Ethernet2 Local MAC code high byte 4
711 +)))
712 +|=(% style="width: 160px;" %)(((
713 +HSW1779
714 +)))|(% style="width:452px" %)(((
715 +Ethernet2 Local MAC code high byte 5
716 +)))
717 +|=(% style="width: 160px;" %)(((
718 +HSW1780
719 +)))|(% style="width:452px" %)(((
720 +Ethernet2 Local MAC code high byte 6
721 +)))
722 +|=(% style="width: 160px;" %)(((
723 +HSW1781
724 +)))|(% colspan="1" rowspan="8" style="width:282px" %)(((
725 +①Display and modify DNS1 and DNS2 of Ethernet2
726 +
727 +②Related registers can be read and written mode (only static IP mode can be written)
728 +)))|(% style="width:452px" %)(((
729 +Ethernet2 Local DNS1 address high byte 1
730 +)))
731 +|=(% style="width: 160px;" %)(((
732 +HSW1782
733 +)))|(% style="width:452px" %)(((
734 +Ethernet2 Local DNS1 address high byte 2
735 +)))
736 +|=(% style="width: 160px;" %)(((
737 +HSW1783
738 +)))|(% style="width:452px" %)(((
739 +Ethernet2 Local DNS1 address high byte 3
740 +)))
741 +|=(% style="width: 160px;" %)(((
742 +HSW1784
743 +)))|(% style="width:452px" %)(((
744 +Ethernet2 Local DNS1 address high byte 4
745 +)))
746 +|=(% style="width: 160px;" %)(((
747 +HSW1785
748 +)))|(% style="width:452px" %)(((
749 +Ethernet2 Local DNS2 address high byte 1
750 +)))
751 +|=(% style="width: 160px;" %)(((
752 +HSW1786
753 +)))|(% style="width:452px" %)(((
754 +Ethernet2 Local DNS2 address high byte 2
755 +)))
756 +|=(% style="width: 160px;" %)(((
757 +HSW1787
758 +)))|(% style="width:452px" %)(((
759 +Ethernet2 Local DNS2 address high byte 3
760 +)))
761 +|=(% style="width: 160px;" %)(((
762 +HSW1788
763 +)))|(% style="width:452px" %)(((
764 +Ethernet2 Local DNS2 address high byte 4
765 +)))
766 +|=(% style="width: 160px;" %)(((
767 +HSW1789
768 +)))|(% colspan="1" style="width:282px" %)(((
769 +Display or set the dynamic or static IP mode of Ethernet2
770 +)))|(% style="width:452px" %)(((
771 +HSX1789.0 = 0, Static IP mode
772 +
773 +HSX1789.0 = 1, dynamic IP mode
774 +)))
775 +|=(% style="width: 160px;" %)(((
776 +HSW1790
777 +)))|(% colspan="1" style="width:282px" %)(((
778 +Confirm Ethernet2 IP, subnet mask, gateway, DNS1, DNS2, and dynamic static IP settings
779 +)))|(% style="width:452px" %)(((
780 +~= 1, confirm the setting (i.e., after modifying IP-related information, set this address to 1, representing confirmation of the modification, after which it will be reset to 0)
781 +)))
782 +|=(% style="width: 160px;" %)(((
783 +HSW1791
784 +)))|(% colspan="1" style="width:282px" %)(((
785 +Network status of the Ethernet2 connection server
786 +)))|(% style="width:452px" %)(((
787 +~= 0, connection to the server is abnormal = 1, connection to the server is normal
788 +)))
621 621  |=(% style="width: 160px;" %)HSW1852|(% style="width:282px" %)Control the interval in two consecutive clicks|(% style="width:452px" %)Limit range: 1~~500ms. The default is 100 ms.
622 622  |=(% style="width: 160px;" %)HSW1853|(% style="width:282px" %)File format for exporting data records to USB flash drive or SD card|(% style="width:452px" %)(((
623 623  * =0: db database
... ... @@ -643,30 +643,87 @@
643 643  * =1: download firmware
644 644  * =2: enter the background
645 645  )))
814 +|=(% style="width: 160px;" %)HSW1865|(% style="width:282px" %)Priority connection to the cloud|(% style="width:452px" %)(((
815 +* =0: priority Ethernet
816 +* =1: priority WLAN
817 +* =2: priority 4G
818 +)))
646 646  |=(% style="width: 160px;" %)HSW1866|(% style="width:282px" %)Delete the LUa extension module file|(% style="width:452px" %)(((
647 -* =1, delete;
648 -* = Others, do not delete
820 +* =0: delete;
821 +* = Others: do not delete
649 649  )))
650 650  |=(% style="width: 160px;" %)HSW1867|(% style="width:282px" %)Reset mode|(% style="width:452px" %)(((
651 651  Monitor address is set during reset of reset switch, whether to cancel reset,
652 652  
653 -* = 0, yes (default);
654 -* = 1, no
826 +* = 0: yes (default);
827 +* = 1: no
655 655  )))
656 656  |=(% style="width: 160px;" %)HSW1868|(% style="width:282px" %)Double-click or long press the record type table mode|(% style="width:452px" %)(((
657 657  Controls whether the button pops up when double-clicking or long pressing on record type table object
658 658  
659 -* = 0, yes (default);
660 -* = 1, no
832 +* = 0: yes (default);
833 +* = 1: no
661 661  )))
835 +|=(% style="width: 160px;" %)(((
836 +HSW1869
837 +)))|(% style="width:282px" %)(((
838 +Dynamic screensaver countdown
839 +)))|(% style="width:452px" %)(((
840 +Countdown to enter dynamic screensaver effect, unit (S)
841 +)))
842 +|=(% style="width: 160px;" %)(((
843 +HSW1870
844 +)))|(% style="width:282px" %)(((
845 +Display or set the dynamic or static IP mode of Ethernet1
846 +)))|(% style="width:452px" %)(((
847 +HSX1870.0 = 0, Static IP mode
848 +
849 +HSX1870.0 = 1, dynamic IP mode
850 +)))
851 +|=(% style="width: 160px;" %)(((
852 +HSW1871
853 +)))|(% style="width:282px" %)(((
854 +Confirm the IP, subnet mask, gateway, DNS1, DNS2, and dynamic static IP settings for Ethernet1
855 +)))|(% style="width:452px" %)(((
856 +~= 1, confirm the setting (i.e., after modifying IP-related information, set this address to 1, representing confirmation of the modification, after which it will be reset to 0)
857 +)))
858 +|=(% style="width: 160px;" %)(((
859 +HSW1872
860 +)))|(% colspan="1" rowspan="8" style="width:282px" %)(((
861 +①Display and modify DNS1 and DNS2 of Ethernet1
862 +
863 +②Related registers can be read and written mode (only static IP mode can be written)
864 +)))|(% style="width:452px" %)(((
865 +Ethernet1 Local DNS1 address high byte 1
866 +)))
867 +|=(% style="width: 160px;" %)(((
868 +HSW1873
869 +)))|(% style="width:452px" %)Ethernet1 Local DNS1 address high byte 2
870 +|=(% style="width: 160px;" %)(((
871 +HSW1874
872 +)))|(% style="width:452px" %)Ethernet1 Local DNS1 address high byte 3
873 +|=(% style="width: 160px;" %)(((
874 +HSW1875
875 +)))|(% style="width:452px" %)Ethernet1 Local DNS1 address high byte 4
876 +|=(% style="width: 160px;" %)(((
877 +HSW1876
878 +)))|(% style="width:452px" %)Ethernet1 Local DNS2 address high byte 1
879 +|=(% style="width: 160px;" %)(((
880 +HSW1877
881 +)))|(% style="width:452px" %)Ethernet1 Local DNS2 address high byte 2
882 +|=(% style="width: 160px;" %)(((
883 +HSW1878
884 +)))|(% style="width:452px" %)Ethernet1 Local DNS2 address high byte 3
885 +|=(% style="width: 160px;" %)(((
886 +HSW1879
887 +)))|(% style="width:452px" %)Ethernet1 Local DNS2 address high byte 4
662 662  |=(% style="width: 160px;" %)HSW10000~~19999|(% style="width:282px" %)Power-down storage area|(% style="width:452px" %)After restart, the data remains
663 663  |=(% style="width: 160px;" %)HSW10035|(% rowspan="13" style="width:282px" %)(((
664 -**✎Note: **Only valid when the HMI is plugged into the Ethernet cable.
665 -
666 -1. If Ethernet settings is enabled in project parameters, this register displays the set value.
667 -1. If Ethernet settings is not enabled in project parameters, IP would automatically obtained IP.
668 -1. If HMI is not connected to the network, the register is displayed as 0 whether the engineering parameters are set.
669 -1. 4. All IP registers of HMI are read-only.
890 +Note: Valid when Ethernet1 of HMI is plugged into the network cable.
891 +①、When the Ethernet setting is enabled in the project parameters, this register displays the set value.
892 +②. When the Ethernet setting is not enabled in the engineering parameters, the register displays the Ethernet IP automatically acquired by the HMI.
893 +③. When the HMI is not plugged into the network cable, the register will show 0 whether the engineering parameters are set or not.
894 +④.IP related registers can be read and written (only static IP mode can be written).
670 670  )))|(% style="width:452px" %)Local IP address high byte 1
671 671  |=(% style="width: 160px;" %)HSW10036|(% style="width:452px" %)Local IP address high byte 2
672 672  |=(% style="width: 160px;" %)HSW10037|(% style="width:452px" %)Local IP address high byte 3
... ... @@ -681,9 +681,11 @@
681 681  |=(% style="width: 160px;" %)HSW10046|(% style="width:452px" %)Local gateway address high byte 4
682 682  |=(% style="width: 160px;" %)HSW10047|(% style="width:452px" %)Local port address
683 683  |=(% style="width: 160px;" %)HSW10048|(% rowspan="6" style="width:282px" %)(((
684 -Displays the MAC code of the current network card
909 +Display the MAC code of Ethernet1 NIC
685 685  
686 -(Hexadecimal display)
911 +(hexadecimal display)
912 +
913 +②Read-only mode, not modifiable
687 687  )))|(% style="width:452px" %)Local MAC code high word 1
688 688  |=(% style="width: 160px;" %)HSW10049|(% style="width:452px" %)Local MAC code high word 2
689 689  |=(% style="width: 160px;" %)HSW10050|(% style="width:452px" %)Local MAC code high word 3
... ... @@ -772,9 +772,36 @@
772 772  )))
773 773  |=(% style="width: 160px;" %)HSW11760|(% style="width:282px" %)Screensaver countdown|(% style="width:452px" %)Display the countdown to enter the Screensaver, unit: second.
774 774  |=(% style="width: 160px;" %)HSW11761|(% style="width:282px" %)Screensaver screen number|(% style="width:452px" %)Set the screen number for Screensaver
1002 +|=(% style="width: 160px;" %)(((
1003 +HSW11762
1004 +)))|(% style="width:282px" %)(((
1005 +Dynamic screensaver control address
1006 +)))|(% style="width:452px" %)(((
1007 +HSX11762.0=0, initialize with project configuration;
775 775  
776 -== **Serial port communication configuration** ==
1009 +HSX11762.0=1, initialize with special register configuration;
777 777  
1011 +HSX11762.1=0, disable dynamic screensaver;
1012 +
1013 +HSX11762.1=1, enable dynamic screensaver
1014 +)))
1015 +|=(% style="width: 160px;" %)(((
1016 +HSW11763
1017 +)))|(% style="width:282px" %)(((
1018 +Waiting time to enter the dynamic screensaver
1019 +)))|(% style="width:452px" %)(((
1020 +Waiting time when the screen is not operated, range 1~~720 minutes
1021 +)))
1022 +|=(% style="width: 160px;" %)(((
1023 +HSW11764
1024 +)))|(% style="width:282px" %)(((
1025 +Animated screensaver animation type
1026 +)))|(% style="width:452px" %)(((
1027 +~=0: Raster,=1: Blinds,=2: Bubble
1028 +)))
1029 +
1030 +== Serial port communication configuration ==
1031 +
778 778  (% class="table-bordered" %)
779 779  |=(% scope="row" style="width: 102px;" %)Port|=(% style="width: 173px;" %)**Function**|=(% style="width: 122px;" %)**Address**|=(% colspan="2" style="width: 506px;" %)**Description**
780 780  |(% colspan="1" rowspan="11" style="width:102px" %)COM1|(% style="width:173px" %)Communication mode|(% style="width:122px" %)HSW10061|(% colspan="2" style="width:506px" %)(((
... ... @@ -806,10 +806,22 @@
806 806  * =1: ODD
807 807  * =2: EVEN
808 808  )))
809 -|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10066|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000
810 -|(% style="width:173px" %)reveive timeout|(% style="width:122px" %)HSW10067|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000
811 -|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10068|(% colspan="2" style="width:506px" %)Unit: times. Range: 0~~100
812 -|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10069|(% colspan="2" style="width:506px" %)Unit: s. Range: 0~~300
1063 +|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10066|(% colspan="2" style="width:506px" %)(((
1064 +* Unit: ms.
1065 +* Range: 0 to 30000
1066 +)))
1067 +|(% style="width:173px" %)reveive timeout|(% style="width:122px" %)HSW10067|(% colspan="2" style="width:506px" %)(((
1068 +* Unit: ms.
1069 +* Range: 0 to 30000
1070 +)))
1071 +|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10068|(% colspan="2" style="width:506px" %)(((
1072 +* Unit: times.
1073 +* Range: 0 to 100
1074 +)))
1075 +|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10069|(% colspan="2" style="width:506px" %)(((
1076 +* Unit: s.
1077 +* Range: 0 to 300
1078 +)))
813 813  |(% style="width:173px" %)HMI station number|(% style="width:122px" %)HSW10070|(% colspan="2" style="width:506px" %)
814 814  |(% style="width:173px" %)PLC station number|(% style="width:122px" %)HSW10071|(% colspan="2" style="width:506px" %)
815 815  |(% colspan="1" rowspan="11" style="width:102px" %)COM1-2|(% style="width:173px" %)Communication mode|(% style="width:122px" %)HSW10094|(% colspan="2" style="width:506px" %)(((
... ... @@ -842,10 +842,22 @@
842 842  * =1: ODD
843 843  * =2: EVEN
844 844  )))
845 -|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10099|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000
846 -|(% style="width:173px" %)receive timeout|(% style="width:122px" %)HSW10100|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000
847 -|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10101|(% colspan="2" style="width:506px" %)Unit: times. Range: 0~~100
848 -|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10102|(% colspan="2" style="width:506px" %)Unit: s. Range: 0~~30
1111 +|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10099|(% colspan="2" style="width:506px" %)(((
1112 +* Unit: ms.
1113 +* Range: 0 to 30000
1114 +)))
1115 +|(% style="width:173px" %)receive timeout|(% style="width:122px" %)HSW10100|(% colspan="2" style="width:506px" %)(((
1116 +* Unit: ms.
1117 +* Range: 0 to 30000
1118 +)))
1119 +|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10101|(% colspan="2" style="width:506px" %)(((
1120 +* Unit: times.
1121 +* Range: 0 to 100
1122 +)))
1123 +|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10102|(% colspan="2" style="width:506px" %)(((
1124 +* Unit: s.
1125 +* Range: 0 to 30
1126 +)))
849 849  |(% style="width:173px" %)HMI station number|(% style="width:122px" %)HSW10103|(% colspan="2" style="width:506px" %)
850 850  |(% style="width:173px" %)PLC station number|(% style="width:122px" %)HSW10104|(% colspan="2" style="width:506px" %)
851 851  |(% colspan="1" rowspan="11" style="width:102px" %)COM1-3|(% style="width:173px" %)Communication mode|(% style="width:122px" %)HSW10120|(% colspan="2" style="width:506px" %)(((
... ... @@ -878,10 +878,22 @@
878 878  * =1: ODD
879 879  * =2: EVEN
880 880  )))
881 -|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10125|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000
882 -|(% style="width:173px" %)receive timeout|(% style="width:122px" %)HSW10126|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000
883 -|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10127|(% colspan="2" style="width:506px" %)Unit: times. Range: 0~~100
884 -|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10128|(% colspan="2" style="width:506px" %)Unit: s. Range: 0~~30
1159 +|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10125|(% colspan="2" style="width:506px" %)(((
1160 +* Unit: ms.
1161 +* Range: 0 to 30000
1162 +)))
1163 +|(% style="width:173px" %)receive timeout|(% style="width:122px" %)HSW10126|(% colspan="2" style="width:506px" %)(((
1164 +* Unit: ms.
1165 +* Range: 0 to 30000
1166 +)))
1167 +|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10127|(% colspan="2" style="width:506px" %)(((
1168 +* Unit: times.
1169 +* Range: 0 to 100
1170 +)))
1171 +|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10128|(% colspan="2" style="width:506px" %)(((
1172 +* Unit: s.
1173 +* Range: 0 to 30
1174 +)))
885 885  |(% style="width:173px" %)HMI station number|(% style="width:122px" %)HSW10129|(% colspan="2" style="width:506px" %)
886 886  |(% style="width:173px" %)PLC station number|(% style="width:122px" %)HSW10130|(% colspan="2" style="width:506px" %)
887 887  |(% colspan="1" rowspan="11" style="width:102px" %)COM2|(% style="width:173px" %)Communication mode|(% style="width:122px" %)HSW10072|(% colspan="2" style="width:506px" %)(((
... ... @@ -912,10 +912,22 @@
912 912  * =1: ODD
913 913  * =2: EVEN
914 914  )))
915 -|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10077|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000
916 -|(% style="width:173px" %)receive timeout|(% style="width:122px" %)HSW10078|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000
917 -|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10079|(% colspan="2" style="width:506px" %)Unit: times. Range: 0~~100
918 -|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10080|(% colspan="2" style="width:506px" %)Unit: s. Range: 0~~30
1205 +|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10077|(% colspan="2" style="width:506px" %)(((
1206 +* Unit: ms.
1207 +* Range: 0 to 30000
1208 +)))
1209 +|(% style="width:173px" %)receive timeout|(% style="width:122px" %)HSW10078|(% colspan="2" style="width:506px" %)(((
1210 +* Unit: ms.
1211 +* Range: 0 to 30000
1212 +)))
1213 +|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10079|(% colspan="2" style="width:506px" %)(((
1214 +* Unit: times.
1215 +* Range: 0 to 100
1216 +)))
1217 +|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10080|(% colspan="2" style="width:506px" %)(((
1218 +* Unit: s.
1219 +* Range: 0 to 30
1220 +)))
919 919  |(% style="width:173px" %)HMI station number|(% style="width:122px" %)HSW10081|(% colspan="2" style="width:506px" %)
920 920  |(% style="width:173px" %)PLC station number|(% style="width:122px" %)HSW10082|(% colspan="2" style="width:506px" %)
921 921  |(% colspan="1" rowspan="11" style="width:102px" %)COM2-2|(% style="width:173px" %)Communication mode|(% style="width:122px" %)HSW10105|(% colspan="2" style="width:506px" %)(((
... ... @@ -946,10 +946,22 @@
946 946  * =1: ODD
947 947  * =2: EVEN
948 948  )))
949 -|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10110|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000
950 -|(% style="width:173px" %)receive timeout|(% style="width:122px" %)HSW10111|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000
951 -|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10112|(% colspan="2" style="width:506px" %)Unit: times. Range: 0~~100
952 -|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10113|(% colspan="2" style="width:506px" %)Unit: s. Range: 0~~30
1251 +|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10110|(% colspan="2" style="width:506px" %)(((
1252 +* Unit: ms.
1253 +* Range: 0 to 30000
1254 +)))
1255 +|(% style="width:173px" %)receive timeout|(% style="width:122px" %)HSW10111|(% colspan="2" style="width:506px" %)(((
1256 +* Unit: ms.
1257 +* Range: 0 to 30000
1258 +)))
1259 +|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10112|(% colspan="2" style="width:506px" %)(((
1260 +* Unit: times.
1261 +* Range: 0 to 100
1262 +)))
1263 +|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10113|(% colspan="2" style="width:506px" %)(((
1264 +* Unit: s.
1265 +* Range: 0 to 30
1266 +)))
953 953  |(% style="width:173px" %)HMI station number|(% style="width:122px" %)HSW10114|(% colspan="2" style="width:506px" %)
954 954  |(% style="width:173px" %)PLC station number|(% style="width:122px" %)HSW10115|(% colspan="2" style="width:506px" %)
955 955  |(% colspan="1" rowspan="11" style="width:102px" %)COM3|(% style="width:173px" %)Communication mode|(% style="width:122px" %)HSW10083|(% colspan="2" style="width:506px" %)(((
... ... @@ -979,29 +979,48 @@
979 979  * =1: ODD
980 980  * =2: EVEN
981 981  )))
982 -|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10088|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000
983 -|(% style="width:173px" %)receive timeout|(% style="width:122px" %)HSW10089|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000
984 -|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10090|(% colspan="2" style="width:506px" %)Unit: times. Range: 0~~100
985 -|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10091|(% colspan="2" style="width:506px" %)Unit: s. Range: 0~~30
1296 +|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10088|(% colspan="2" style="width:506px" %)(((
1297 +* Unit: ms.
1298 +* Range: 0 to 30000
1299 +)))
1300 +|(% style="width:173px" %)receive timeout|(% style="width:122px" %)HSW10089|(% colspan="2" style="width:506px" %)(((
1301 +* Unit: ms.
1302 +* Range: 0 to 30000
1303 +)))
1304 +|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10090|(% colspan="2" style="width:506px" %)(((
1305 +* Unit: times.
1306 +* Range: 0 to 100
1307 +)))
1308 +|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10091|(% colspan="2" style="width:506px" %)(((
1309 +* Unit: s.
1310 +* Range: 0 to 30
1311 +)))
986 986  |(% style="width:173px" %)HMI station number|(% style="width:122px" %)HSW10092|(% colspan="2" style="width:506px" %)
987 987  |(% style="width:173px" %)PLC station number|(% style="width:122px" %)HSW10093|(% colspan="2" style="width:506px" %)
988 988  |(% colspan="1" rowspan="2" style="width:102px" %)CAN port|(% style="width:173px" %)CAN1 baud rate|(% style="width:122px" %)HSW010116|(% style="width:299px" %)(((
989 -Unit: K, the baud rate must be an integer, for example, when the baud rate required is 250000, just enter 250.
1315 +Unit: K, the baud rate must be an integer.
1316 +
1317 +For example, when the baud rate required is 250000, just enter 250.
990 990  )))|(% colspan="1" rowspan="2" style="width:218px" %)**✎Note: **If baud rate has been modified,please wait 5 seconds,then restart the HMI to take effect.
991 -|(% style="width:173px" %)CAN2 baud rate|(% style="width:122px" %)HSW010117|(% style="width:299px" %)Unit: K, the baud rate must be an integer, for example, when the baud rate required is 250000, just enter 250.
1319 +|(% style="width:173px" %)CAN2 baud rate|(% style="width:122px" %)HSW010117|(% style="width:299px" %)(((
1320 +Unit: K, the baud rate must be an integer.
992 992  
993 -== **Ethernet communication configuration** ==
1322 +For example, when the baud rate required is 250000, just enter 250.
1323 +)))
994 994  
1325 +== Ethernet communication configuration ==
1326 +
995 995  (% class="table-bordered" %)
996 -|=(% style="width: 40px;" %)**No.**|=(% style="width: 295px;" %)**Function**|=(% style="width: 220px;" %)**Address**|=(% style="width: 336px;" %)**Description**
1328 +|(% style="width:40px" %)**No.**|(% style="width:295px" %)**Function**|(% style="width:220px" %)**Address**|(% style="width:336px" %)**Description**
997 997  |(% rowspan="7" style="width:40px" %)1|(% colspan="1" rowspan="7" style="width:295px" %)Ethernet parameter configuration for communication number 1 in list. Configure those addresses according to connected device. After configuration, wait for 5 seconds and restart the HMI.|(% style="width:220px" %)HSW11004|(% style="width:336px" %)Device IP address high word 1
998 998  |(% style="width:220px" %)HSW11005|(% style="width:336px" %)Device IP address high word 2
999 999  |(% style="width:220px" %)HSW11006|(% style="width:336px" %)Device IP address high word 3
1000 1000  |(% style="width:220px" %)HSW11007|(% style="width:336px" %)Device IP address high word 4
1001 1001  |(% style="width:220px" %)HSW11008|(% style="width:336px" %)Device Port number
1002 -|(% style="width:220px" %)HSW11009|=(% style="width: 336px;" %)(((
1003 -* =2 TCP
1004 -* =3 UDP
1334 +|(% style="width:220px" %)HSW11009|(% style="width:336px" %)(((
1335 +~=2 TCP
1336 +
1337 +~=3 UDP
1005 1005  )))
1006 1006  |(% style="width:220px" %)HSW11010|(% style="width:336px" %)Reserved
1007 1007  |(% rowspan="7" style="width:40px" %)2|(% colspan="1" rowspan="7" style="width:295px" %)Ethernet parameter configuration for communication number 2 in list. Configure those addresses according to connected device. After configuration, wait for 5 seconds and restart the HMI.|(% style="width:220px" %)HSW11011|(% style="width:336px" %)Device IP address high word 1
... ... @@ -1009,9 +1009,10 @@
1009 1009  |(% style="width:220px" %)HSW11013|(% style="width:336px" %)Device IP address high word 3
1010 1010  |(% style="width:220px" %)HSW11014|(% style="width:336px" %)Device IP address high word 4
1011 1011  |(% style="width:220px" %)HSW11015|(% style="width:336px" %)Device Port number
1012 -|(% style="width:220px" %)HSW11016|=(% style="width: 336px;" %)(((
1013 -* =2 TCP
1014 -* =3 UDP
1345 +|(% style="width:220px" %)HSW11016|(% style="width:336px" %)(((
1346 +~=2 TCP
1347 +
1348 +~=3 UDP
1015 1015  )))
1016 1016  |(% style="width:220px" %)HSW11017|(% style="width:336px" %)Reserved
1017 1017  |(% style="width:40px" %)…|(% style="width:295px" %) |(% style="width:220px" %)…|(% style="width:336px" %)…
... ... @@ -1020,7 +1020,11 @@
1020 1020  |(% style="width:220px" %)HSW11223|(% style="width:336px" %)Device IP address high word 3
1021 1021  |(% style="width:220px" %)HSW11224|(% style="width:336px" %)Device IP address high word 4
1022 1022  |(% style="width:220px" %)HSW11225|(% style="width:336px" %)Device Port number
1023 -|(% style="width:220px" %)HSW11226|=(% style="width: 336px;" %)2 TCP; =3 UDP
1357 +|(% style="width:220px" %)HSW11226|(% style="width:336px" %)(((
1358 +~=2 TCP;
1359 +
1360 +~=3 UDP
1361 +)))
1024 1024  |(% style="width:220px" %)HSW11227|(% style="width:336px" %)Reserved
1025 1025  
1026 1026  (% class="box infomessage" %)
... ... @@ -1028,7 +1028,7 @@
1028 1028  **✎Note:** The number of Ethernet connections supported by different HMI series varies.
1029 1029  )))
1030 1030  
1031 -== **Communication control** ==
1369 +== Communication control ==
1032 1032  
1033 1033  (% class="table-bordered" %)
1034 1034  |=(% style="width: 135px;" %)**Communication No.**|=(% style="width: 102px;" %)**Station No.**|=(% style="width: 185px;" %)**Control bit**|=(% style="width: 191px;" %)**Communication lamp**|=(% style="width: 271px;" %)**Description**