Changes for page 13 HMI Internal Registers
Last modified by Jett on 2025/04/28 16:07
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Stone1 +XWiki.Hunter - Content
-
... ... @@ -4,11 +4,11 @@ 4 4 5 5 *HSW, HDW, HUW, HAW are word address, HSX, HDX, HUX, HAX are bit address. 6 6 7 - 1.**System data area (HSW): **A special register defined by the system.8 - 1.**Data storage area (HDW/HDX): **Users store user data.9 - 1.**System data area (HUW): **A special register defined by the system.10 - 1.**System Data (HAW)**: System register used for power-off save.11 - 1.**Recipe index area (RPW): **System register used for recipe index.7 +* **System data area (HSW): **A special register defined by the system. 8 +* **Data storage area (HDW/HDX): **Users store user data. 9 +* **System data area (HUW): **A special register defined by the system. 10 +* **System Data (HAW)**: System register used for power-off save. 11 +* **Recipe index area (RPW): **System register used for recipe index. 12 12 13 13 HMI internal registers are divided into bit address and word address, which can be accessed in two ways (take HDW as an example). 14 14 ... ... @@ -25,6 +25,21 @@ 25 25 * The address of the bit address HDX is with a decimal point while word addresses are integers. 26 26 ))) 27 27 28 +(% class="wikigeneratedid" %) 29 += Address ranges table = 30 + 31 +|=(% scope="row" style="width: 206px;" %)Address Type\HMI Series|=(% style="width: 240px;" %)General Series|=(% style="width: 200px;" %)i Series/HMI+ models|=(% style="width: 136px;" %)ie Series|=(% style="width: 232px;" %)ig Series 32 +|=(% style="width: 206px;" %)HDW|HDW0-HDW299999|HDW0-HDW299999|HDW0-HDW299999|HDW0-HDW299999 33 +|=(% style="width: 206px;" %)HSW|HSW0-HSW14999|HSW0-HSW14999|HSW0-HSW14999|HSW0-HSW14999 34 +|=(% style="width: 206px;" %)HAW|HAW0-HAW199999|HAW0-HAW199999|HAW0-HAW199999|HAW0-HAW199999 35 +|=(% style="width: 206px;" %)HUW|HUW0-HUW1599|HUW0-HUW1599|HUW0-HUW1599|HUW0-HUW1599 36 +|=(% style="width: 206px;" %)HDX|HDX0.0-HDX299999.15|HDX0.0-HDX299999.15|HDX0.0-HDX299999.15|HDX0.0-HDX299999.15 37 +|=(% style="width: 206px;" %)HSX|HSX0.0-HSX14999.15|HSX0.0-HSX14999.15|HSX0-HSX14999.15|HSX0.0-HSX14999.15 38 +|=(% style="width: 206px;" %)HAX|HAX0.0-HAX199999.15|HAX0.0-HAX199999.15|HAX0.0-HAX199999.15|HAX0.0-HAX199999.15 39 +|=(% style="width: 206px;" %)HUX|HUX0.0-HUX1599.15|HUX0.0-HUX1599.15|HUX0.0-HUX1599.15|HUX0.0-HUX1599.15 40 +|=(% style="width: 206px;" %)RPW| |RPW000000-RPW990450|RPW000000-RPW990450|RPW000000-RPW990450 41 +|=(% style="width: 206px;" %) |(% style="width:240px" %) |(% style="width:200px" %) |(% style="width:136px" %) |(% style="width:232px" %) 42 + 28 28 = **Data storage area (HDW/HDX)** = 29 29 30 30 It is used to save the temporary data of project. ... ... @@ -241,8 +241,8 @@ 241 241 * =2: HSX521.1=1, delete all trend graph. 242 242 * =4: HSX521.2=1, delete all alarms. 243 243 * =16: HSX521.4=1, delete history XY plot. 244 -* =32: HSX521.5=1, delete data records in SD card or flash dis h;(Please make a setting which is saved to flash disk or SD card in project setting).245 -* =64: HSX521.6=1, delete alarms records in SD card or flash dis h; (Please make a setting which is saved to flash disk or SD card in project setting).259 +* =32: HSX521.5=1, delete data records in SD card or USB flash disk;(Please make a setting which is saved to USB flash disk or SD card in project setting). 260 +* =64: HSX521.6=1, delete alarms records in SD card or USB flash disk; (Please make a setting which is saved to USB flash disk or SD card in project setting). 246 246 ))) 247 247 |=(% style="width: 160px;" %)HSW522|(% style="width:282px" %)Copy and paste the alarm/data files in flash to the USB flash disk|(% style="width:452px" %)((( 248 248 * =0: No operation ... ... @@ -485,6 +485,8 @@ 485 485 * =0, Default value 486 486 * =1, Release the alarm generated before the last power-down when starting up 487 487 ))) 503 +|=(% style="width: 160px;" %)HSW1200|(% colspan="1" rowspan="2" style="width:282px" %)TSAP settings for HMI in the Siemens LOGO! 8 protocol(ig series or HMI V2.0)|(% style="width:452px" %)HMI local TSAP, which corresponds to the remote TSAP of PLC 504 +|=(% style="width: 160px;" %)HSW1201|(% style="width:452px" %)HMI remote TSAP, which corresponds to the local TSAP of PLC 488 488 |=(% style="width: 160px;" %)HSW1450|(% style="width:282px" %)Enable objects level password function|(% style="width:452px" %)((( 489 489 * =0, Disable 490 490 * =1, Enable ... ... @@ -591,6 +591,9 @@ 591 591 * =0: Server connection exception 592 592 * =1: Server connection is OK 593 593 ))) 611 +|=(% style="width: 160px;" %)HSW1740|(% style="width:282px" %)Wi-fi signal strength|(% style="width:452px" %)((( 612 +Display the value of Wi-fi signal signal strength, ranges from 0~~100 (Signal strength is automatically obtained only once when HMI is powered on, and it will not be automatically updated. It needs to be used with the HSW1890) 613 +))) 594 594 |=(% style="width: 160px;" %)HSW1741|(% colspan="1" rowspan="12" style="width:282px" %)Related IP register in 4Gnetwork status (It is valid when HMI is connected to 4G)|(% style="width:452px" %)Local IP address high byte 1 595 595 |=(% style="width: 160px;" %)HSW1742|(% style="width:452px" %)Local IP address high byte 2 596 596 |=(% style="width: 160px;" %)HSW1743|(% style="width:452px" %)Local IP address high byte 3 ... ... @@ -618,10 +618,180 @@ 618 618 * =1: Server connection is OK 619 619 ))) 620 620 |=(% style="width: 160px;" %)HSW1761|(% style="width:282px" %)Display 4G network signal strength|(% style="width:452px" %)Signal strength: 0~~31. The greater the value ,the signal is stronger 641 +|=(% style="width: 160px;" %)((( 642 +HSW1762 643 +)))|(% colspan="1" rowspan="13" style="width:282px" %)((( 644 +Note: Valid when Ethernet2 of HMI is plugged into the network cable. 645 +①、When the Ethernet setting is enabled in the project parameters, this register displays the set value. 646 +②. When the Ethernet setting is not enabled in the engineering parameters, the register displays the Ethernet IP automatically acquired by the HMI. 647 +③. When the HMI is not plugged into the network cable, the register will show 0 whether the engineering parameters are set or not. 648 +④.IP related registers can be read and written (only static IP mode can be written). 649 +)))|(% style="width:452px" %)((( 650 +Ethernet2 Local IP address high byte 1 651 +))) 652 +|=(% style="width: 160px;" %)((( 653 +HSW1763 654 +)))|(% style="width:452px" %)((( 655 +Ethernet2 Local IP address high byte 2 656 +))) 657 +|=(% style="width: 160px;" %)((( 658 +HSW1764 659 +)))|(% style="width:452px" %)((( 660 +Ethernet2 Local IP address high byte 3 661 +))) 662 +|=(% style="width: 160px;" %)((( 663 +HSW1765 664 +)))|(% style="width:452px" %)((( 665 +Ethernet2 Local IP address high byte 4 666 +))) 667 +|=(% style="width: 160px;" %)((( 668 +HSW1766 669 +)))|(% style="width:452px" %)((( 670 +Ethernet2 Local mask IP address high byte 1 671 +))) 672 +|=(% style="width: 160px;" %)((( 673 +HSW1767 674 +)))|(% style="width:452px" %)((( 675 +Ethernet2 Local mask IP address high byte 2 676 +))) 677 +|=(% style="width: 160px;" %)((( 678 +HSW1768 679 +)))|(% style="width:452px" %)Ethernet2 Local mask IP address high byte 3 680 +|=(% style="width: 160px;" %)HSW1769|(% style="width:452px" %)Ethernet2 Local mask IP address high byte 4 681 +|=(% style="width: 160px;" %)((( 682 +HSW1770 683 +)))|(% style="width:452px" %)((( 684 +Ethernet2 Local gateway IP address high byte 1 685 +))) 686 +|=(% style="width: 160px;" %)((( 687 +HSW1771 688 +)))|(% style="width:452px" %)((( 689 +Ethernet2 Local gateway IP address high byte 2 690 +))) 691 +|=(% style="width: 160px;" %)((( 692 +HSW1772 693 +)))|(% style="width:452px" %)((( 694 +Ethernet2 Local gateway IP address high byte 3 695 +))) 696 +|=(% style="width: 160px;" %)((( 697 +HSW1773 698 +)))|(% style="width:452px" %)((( 699 +Ethernet2 Local gateway IP address high byte 4 700 +))) 701 +|=(% style="width: 160px;" %)((( 702 +HSW1774 703 +)))|(% style="width:452px" %)((( 704 +Ethernet2 Local Port Address 705 +))) 706 +|=(% style="width: 160px;" %)((( 707 +HSW1775 708 +)))|(% colspan="1" rowspan="6" style="width:282px" %)((( 709 +①Display the MAC code of Ethernet2 NIC 710 + 711 +(hexadecimal display) 712 + 713 +②Read-only mode, not modifiable 714 +)))|(% style="width:452px" %)((( 715 +Ethernet2 Local MAC code high byte 1 716 +))) 717 +|=(% style="width: 160px;" %)((( 718 +HSW1776 719 +)))|(% style="width:452px" %)((( 720 +Ethernet2 Local MAC code high byte 2 721 +))) 722 +|=(% style="width: 160px;" %)((( 723 +HSW1777 724 +)))|(% style="width:452px" %)((( 725 +Ethernet2 Local MAC code high byte 3 726 +))) 727 +|=(% style="width: 160px;" %)((( 728 +HSW1778 729 +)))|(% style="width:452px" %)((( 730 +Ethernet2 Local MAC code high byte 4 731 +))) 732 +|=(% style="width: 160px;" %)((( 733 +HSW1779 734 +)))|(% style="width:452px" %)((( 735 +Ethernet2 Local MAC code high byte 5 736 +))) 737 +|=(% style="width: 160px;" %)((( 738 +HSW1780 739 +)))|(% style="width:452px" %)((( 740 +Ethernet2 Local MAC code high byte 6 741 +))) 742 +|=(% style="width: 160px;" %)((( 743 +HSW1781 744 +)))|(% colspan="1" rowspan="8" style="width:282px" %)((( 745 +①Display and modify DNS1 and DNS2 of Ethernet2 746 + 747 +②Related registers can be read and written mode (only static IP mode can be written) 748 +)))|(% style="width:452px" %)((( 749 +Ethernet2 Local DNS1 address high byte 1 750 +))) 751 +|=(% style="width: 160px;" %)((( 752 +HSW1782 753 +)))|(% style="width:452px" %)((( 754 +Ethernet2 Local DNS1 address high byte 2 755 +))) 756 +|=(% style="width: 160px;" %)((( 757 +HSW1783 758 +)))|(% style="width:452px" %)((( 759 +Ethernet2 Local DNS1 address high byte 3 760 +))) 761 +|=(% style="width: 160px;" %)((( 762 +HSW1784 763 +)))|(% style="width:452px" %)((( 764 +Ethernet2 Local DNS1 address high byte 4 765 +))) 766 +|=(% style="width: 160px;" %)((( 767 +HSW1785 768 +)))|(% style="width:452px" %)((( 769 +Ethernet2 Local DNS2 address high byte 1 770 +))) 771 +|=(% style="width: 160px;" %)((( 772 +HSW1786 773 +)))|(% style="width:452px" %)((( 774 +Ethernet2 Local DNS2 address high byte 2 775 +))) 776 +|=(% style="width: 160px;" %)((( 777 +HSW1787 778 +)))|(% style="width:452px" %)((( 779 +Ethernet2 Local DNS2 address high byte 3 780 +))) 781 +|=(% style="width: 160px;" %)((( 782 +HSW1788 783 +)))|(% style="width:452px" %)((( 784 +Ethernet2 Local DNS2 address high byte 4 785 +))) 786 +|=(% style="width: 160px;" %)((( 787 +HSW1789 788 +)))|(% colspan="1" style="width:282px" %)((( 789 +Display or set the dynamic or static IP mode of Ethernet2 790 +)))|(% style="width:452px" %)((( 791 +HSX1789.0 = 0, Static IP mode 792 + 793 +HSX1789.0 = 1, dynamic IP mode 794 +))) 795 +|=(% style="width: 160px;" %)((( 796 +HSW1790 797 +)))|(% colspan="1" style="width:282px" %)((( 798 +Confirm Ethernet2 IP, subnet mask, gateway, DNS1, DNS2, and dynamic static IP settings 799 +)))|(% style="width:452px" %)((( 800 +~= 1, confirm the setting (i.e., after modifying IP-related information, set this address to 1, representing confirmation of the modification, after which it will be reset to 0) 801 +))) 802 +|=(% style="width: 160px;" %)((( 803 +HSW1791 804 +)))|(% colspan="1" style="width:282px" %)((( 805 +Network status of the Ethernet2 connection server 806 +)))|(% style="width:452px" %)((( 807 +~= 0, connection to the server is abnormal = 1, connection to the server is normal 808 +))) 621 621 |=(% style="width: 160px;" %)HSW1852|(% style="width:282px" %)Control the interval in two consecutive clicks|(% style="width:452px" %)Limit range: 1~~500ms. The default is 100 ms. 622 622 |=(% style="width: 160px;" %)HSW1853|(% style="width:282px" %)File format for exporting data records to USB flash drive or SD card|(% style="width:452px" %)((( 623 623 * =0: db database 624 624 * =1: CSV 813 + 814 +(Only valid for script function DbToCsvFile) 625 625 ))) 626 626 |=(% style="width: 160px;" %)HSW1854|(% style="width:282px" %)High and low word conversion type|(% style="width:452px" %)((( 627 627 * =0: use the old high-low word conversion (default) ... ... @@ -643,30 +643,96 @@ 643 643 * =1: download firmware 644 644 * =2: enter the background 645 645 ))) 646 -|=(% style="width: 160px;" %)HSW1866|(% style="width:282px" %)Delete the LUa extension module file|(% style="width:452px" %)((( 647 -* =1, delete; 648 -* = Others, do not delete 836 +|=(% style="width: 160px;" %)HSW1865|(% style="width:282px" %)Priority connection to the cloud|(% style="width:452px" %)((( 837 +* =0: priority Ethernet 838 +* =1: priority WLAN 839 +* =2: priority 4G 649 649 ))) 841 +|=(% style="width: 160px;" %)HSW1866|(% style="width:282px" %)Delete the Lua extension module file|(% style="width:452px" %)((( 842 +* =0: delete; 843 +* = Others: do not delete 844 +))) 650 650 |=(% style="width: 160px;" %)HSW1867|(% style="width:282px" %)Reset mode|(% style="width:452px" %)((( 651 651 Monitor address is set during reset of reset switch, whether to cancel reset, 652 652 653 -* = 0 ,yes (default);654 -* = 1 ,no848 +* = 0: yes (default); 849 +* = 1: no 655 655 ))) 656 656 |=(% style="width: 160px;" %)HSW1868|(% style="width:282px" %)Double-click or long press the record type table mode|(% style="width:452px" %)((( 657 657 Controls whether the button pops up when double-clicking or long pressing on record type table object 658 658 659 -* = 0 ,yes (default);660 -* = 1 ,no854 +* = 0: yes (default); 855 +* = 1: no 661 661 ))) 857 +|=(% style="width: 160px;" %)((( 858 +HSW1869 859 +)))|(% style="width:282px" %)((( 860 +Dynamic screensaver countdown 861 +)))|(% style="width:452px" %)((( 862 +Countdown to enter dynamic screensaver effect, unit (S) 863 +))) 864 +|=(% style="width: 160px;" %)((( 865 +HSW1870 866 +)))|(% style="width:282px" %)((( 867 +Display or set the dynamic or static IP mode of Ethernet1 868 +)))|(% style="width:452px" %)((( 869 +HSX1870.0 = 0, Static IP mode 870 + 871 +HSX1870.0 = 1, dynamic IP mode 872 +))) 873 +|=(% style="width: 160px;" %)((( 874 +HSW1871 875 +)))|(% style="width:282px" %)((( 876 +Confirm the IP, subnet mask, gateway, DNS1, DNS2, and dynamic static IP settings for Ethernet1 877 +)))|(% style="width:452px" %)((( 878 +~= 1, confirm the setting (i.e., after modifying IP-related information, set this address to 1, representing confirmation of the modification, after which it will be reset to 0) 879 +))) 880 +|=(% style="width: 160px;" %)((( 881 +HSW1872 882 +)))|(% colspan="1" rowspan="8" style="width:282px" %)((( 883 +①Display and modify DNS1 and DNS2 of Ethernet1 884 + 885 +②Related registers can be read and written mode (only static IP mode can be written) 886 +)))|(% style="width:452px" %)((( 887 +Ethernet1 Local DNS1 address high byte 1 888 +))) 889 +|=(% style="width: 160px;" %)((( 890 +HSW1873 891 +)))|(% style="width:452px" %)Ethernet1 Local DNS1 address high byte 2 892 +|=(% style="width: 160px;" %)((( 893 +HSW1874 894 +)))|(% style="width:452px" %)Ethernet1 Local DNS1 address high byte 3 895 +|=(% style="width: 160px;" %)((( 896 +HSW1875 897 +)))|(% style="width:452px" %)Ethernet1 Local DNS1 address high byte 4 898 +|=(% style="width: 160px;" %)((( 899 +HSW1876 900 +)))|(% style="width:452px" %)Ethernet1 Local DNS2 address high byte 1 901 +|=(% style="width: 160px;" %)((( 902 +HSW1877 903 +)))|(% style="width:452px" %)Ethernet1 Local DNS2 address high byte 2 904 +|=(% style="width: 160px;" %)((( 905 +HSW1878 906 +)))|(% style="width:452px" %)Ethernet1 Local DNS2 address high byte 3 907 +|=(% style="width: 160px;" %)((( 908 +HSW1879 909 +)))|(% style="width:452px" %)Ethernet1 Local DNS2 address high byte 4 910 +|=(% style="width: 160px;" %)HSW1890|(% colspan="1" style="width:282px" %)Enable refresh current network signal|(% style="width:452px" %)((( 911 +* =1: Refresh the network signal once after triggered (This register will be automatically reset after triggered, only update the signal value once after per 15 seconds, not able to update twice in the short interval) 912 +* =Others: not refresh 913 +))) 914 +|=(% style="width: 160px;" %)HSW1891|(% colspan="1" style="width:282px" %)Enable clear cache for screen data |(% style="width:452px" %)((( 915 +* =1, not clear screen cache when switch language 916 +* =2, trigger clear cache of all screens for once time 917 +* =3, always clear cache of all screen data 918 +))) 662 662 |=(% style="width: 160px;" %)HSW10000~~19999|(% style="width:282px" %)Power-down storage area|(% style="width:452px" %)After restart, the data remains 663 663 |=(% style="width: 160px;" %)HSW10035|(% rowspan="13" style="width:282px" %)((( 664 -**✎Note: **Only valid when the HMI is plugged into the Ethernet cable. 665 - 666 -1. If Ethernet settings is enabled in project parameters, this register displays the set value. 667 -1. If Ethernet settings is not enabled in project parameters, IP would automatically obtained IP. 668 -1. If HMI is not connected to the network, the register is displayed as 0 whether the engineering parameters are set. 669 -1. 4. All IP registers of HMI are read-only. 921 +Note: Valid when Ethernet1 of HMI is plugged into the network cable. 922 +①、When the Ethernet setting is enabled in the project parameters, this register displays the set value. 923 +②. When the Ethernet setting is not enabled in the engineering parameters, the register displays the Ethernet IP automatically acquired by the HMI. 924 +③. When the HMI is not plugged into the network cable, the register will show 0 whether the engineering parameters are set or not. 925 +④.IP related registers can be read and written (only static IP mode can be written). 670 670 )))|(% style="width:452px" %)Local IP address high byte 1 671 671 |=(% style="width: 160px;" %)HSW10036|(% style="width:452px" %)Local IP address high byte 2 672 672 |=(% style="width: 160px;" %)HSW10037|(% style="width:452px" %)Local IP address high byte 3 ... ... @@ -681,9 +681,11 @@ 681 681 |=(% style="width: 160px;" %)HSW10046|(% style="width:452px" %)Local gateway address high byte 4 682 682 |=(% style="width: 160px;" %)HSW10047|(% style="width:452px" %)Local port address 683 683 |=(% style="width: 160px;" %)HSW10048|(% rowspan="6" style="width:282px" %)((( 684 -Display sthe MAC code of thecurrent networkcard940 +①Display the MAC code of Ethernet1 NIC 685 685 686 -(Hexadecimal display) 942 +(hexadecimal display) 943 + 944 +②Read-only mode, not modifiable 687 687 )))|(% style="width:452px" %)Local MAC code high word 1 688 688 |=(% style="width: 160px;" %)HSW10049|(% style="width:452px" %)Local MAC code high word 2 689 689 |=(% style="width: 160px;" %)HSW10050|(% style="width:452px" %)Local MAC code high word 3 ... ... @@ -690,7 +690,7 @@ 690 690 |=(% style="width: 160px;" %)HSW10051|(% style="width:452px" %)Local MAC code high word 4 691 691 |=(% style="width: 160px;" %)HSW10052|(% style="width:452px" %)Local MAC code high word 5 692 692 |=(% style="width: 160px;" %)HSW10053|(% style="width:452px" %)Local MAC code high word 6 693 -|=(% style="width: 160px;" %)HSW10118|(% colspan="1" rowspan="2" style="width:282px" %)TSAP settings for HMI in the Siemens logo! 8 protocol|(% style="width:452px" %)HMI local TSAP, which corresponds to the remote TSAP of PLC951 +|=(% style="width: 160px;" %)HSW10118|(% colspan="1" rowspan="2" style="width:282px" %)TSAP settings for HMI in the Siemens LOGO! 8 protocol|(% style="width:452px" %)HMI local TSAP, which corresponds to the remote TSAP of PLC 694 694 |=(% style="width: 160px;" %)HSW10119|(% style="width:452px" %)HMI remote TSAP, which corresponds to the local TSAP of PLC 695 695 |=(% style="width: 160px;" %)HSW10461~~10493|(% style="width:282px" %)Remote access password|(% style="width:452px" %)8-character remote access password 696 696 |=(% style="width: 160px;" %)HSW10494~~10558|(% style="width:282px" %)Machine ID (Read only)|(% style="width:452px" %)Machine ID for remote access (read only 64-bit) ... ... @@ -772,9 +772,36 @@ 772 772 ))) 773 773 |=(% style="width: 160px;" %)HSW11760|(% style="width:282px" %)Screensaver countdown|(% style="width:452px" %)Display the countdown to enter the Screensaver, unit: second. 774 774 |=(% style="width: 160px;" %)HSW11761|(% style="width:282px" %)Screensaver screen number|(% style="width:452px" %)Set the screen number for Screensaver 1033 +|=(% style="width: 160px;" %)((( 1034 +HSW11762 1035 +)))|(% style="width:282px" %)((( 1036 +Dynamic screensaver control address 1037 +)))|(% style="width:452px" %)((( 1038 +HSX11762.0=0, initialize with project configuration; 775 775 776 -= =**Serialport communicationconfiguration** ==1040 +HSX11762.0=1, initialize with special register configuration; 777 777 1042 +HSX11762.1=0, disable dynamic screensaver; 1043 + 1044 +HSX11762.1=1, enable dynamic screensaver 1045 +))) 1046 +|=(% style="width: 160px;" %)((( 1047 +HSW11763 1048 +)))|(% style="width:282px" %)((( 1049 +Waiting time to enter the dynamic screensaver 1050 +)))|(% style="width:452px" %)((( 1051 +Waiting time when the screen is not operated, range 1~~720 minutes 1052 +))) 1053 +|=(% style="width: 160px;" %)((( 1054 +HSW11764 1055 +)))|(% style="width:282px" %)((( 1056 +Animated screensaver animation type 1057 +)))|(% style="width:452px" %)((( 1058 +~=0: Raster,=1: Blinds,=2: Bubble 1059 +))) 1060 + 1061 +== Serial port communication configuration == 1062 + 778 778 (% class="table-bordered" %) 779 779 |=(% scope="row" style="width: 102px;" %)Port|=(% style="width: 173px;" %)**Function**|=(% style="width: 122px;" %)**Address**|=(% colspan="2" style="width: 506px;" %)**Description** 780 780 |(% colspan="1" rowspan="11" style="width:102px" %)COM1|(% style="width:173px" %)Communication mode|(% style="width:122px" %)HSW10061|(% colspan="2" style="width:506px" %)((( ... ... @@ -806,10 +806,22 @@ 806 806 * =1: ODD 807 807 * =2: EVEN 808 808 ))) 809 -|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10066|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000 810 -|(% style="width:173px" %)reveive timeout|(% style="width:122px" %)HSW10067|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000 811 -|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10068|(% colspan="2" style="width:506px" %)Unit: times. Range: 0~~100 812 -|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10069|(% colspan="2" style="width:506px" %)Unit: s. Range: 0~~300 1094 +|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10066|(% colspan="2" style="width:506px" %)((( 1095 +* Unit: ms. 1096 +* Range: 0 to 30000 1097 +))) 1098 +|(% style="width:173px" %)reveive timeout|(% style="width:122px" %)HSW10067|(% colspan="2" style="width:506px" %)((( 1099 +* Unit: ms. 1100 +* Range: 0 to 30000 1101 +))) 1102 +|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10068|(% colspan="2" style="width:506px" %)((( 1103 +* Unit: times. 1104 +* Range: 0 to 100 1105 +))) 1106 +|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10069|(% colspan="2" style="width:506px" %)((( 1107 +* Unit: s. 1108 +* Range: 0 to 300 1109 +))) 813 813 |(% style="width:173px" %)HMI station number|(% style="width:122px" %)HSW10070|(% colspan="2" style="width:506px" %) 814 814 |(% style="width:173px" %)PLC station number|(% style="width:122px" %)HSW10071|(% colspan="2" style="width:506px" %) 815 815 |(% colspan="1" rowspan="11" style="width:102px" %)COM1-2|(% style="width:173px" %)Communication mode|(% style="width:122px" %)HSW10094|(% colspan="2" style="width:506px" %)((( ... ... @@ -842,10 +842,22 @@ 842 842 * =1: ODD 843 843 * =2: EVEN 844 844 ))) 845 -|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10099|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000 846 -|(% style="width:173px" %)receive timeout|(% style="width:122px" %)HSW10100|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000 847 -|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10101|(% colspan="2" style="width:506px" %)Unit: times. Range: 0~~100 848 -|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10102|(% colspan="2" style="width:506px" %)Unit: s. Range: 0~~30 1142 +|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10099|(% colspan="2" style="width:506px" %)((( 1143 +* Unit: ms. 1144 +* Range: 0 to 30000 1145 +))) 1146 +|(% style="width:173px" %)receive timeout|(% style="width:122px" %)HSW10100|(% colspan="2" style="width:506px" %)((( 1147 +* Unit: ms. 1148 +* Range: 0 to 30000 1149 +))) 1150 +|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10101|(% colspan="2" style="width:506px" %)((( 1151 +* Unit: times. 1152 +* Range: 0 to 100 1153 +))) 1154 +|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10102|(% colspan="2" style="width:506px" %)((( 1155 +* Unit: s. 1156 +* Range: 0 to 30 1157 +))) 849 849 |(% style="width:173px" %)HMI station number|(% style="width:122px" %)HSW10103|(% colspan="2" style="width:506px" %) 850 850 |(% style="width:173px" %)PLC station number|(% style="width:122px" %)HSW10104|(% colspan="2" style="width:506px" %) 851 851 |(% colspan="1" rowspan="11" style="width:102px" %)COM1-3|(% style="width:173px" %)Communication mode|(% style="width:122px" %)HSW10120|(% colspan="2" style="width:506px" %)((( ... ... @@ -878,10 +878,22 @@ 878 878 * =1: ODD 879 879 * =2: EVEN 880 880 ))) 881 -|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10125|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000 882 -|(% style="width:173px" %)receive timeout|(% style="width:122px" %)HSW10126|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000 883 -|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10127|(% colspan="2" style="width:506px" %)Unit: times. Range: 0~~100 884 -|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10128|(% colspan="2" style="width:506px" %)Unit: s. Range: 0~~30 1190 +|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10125|(% colspan="2" style="width:506px" %)((( 1191 +* Unit: ms. 1192 +* Range: 0 to 30000 1193 +))) 1194 +|(% style="width:173px" %)receive timeout|(% style="width:122px" %)HSW10126|(% colspan="2" style="width:506px" %)((( 1195 +* Unit: ms. 1196 +* Range: 0 to 30000 1197 +))) 1198 +|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10127|(% colspan="2" style="width:506px" %)((( 1199 +* Unit: times. 1200 +* Range: 0 to 100 1201 +))) 1202 +|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10128|(% colspan="2" style="width:506px" %)((( 1203 +* Unit: s. 1204 +* Range: 0 to 30 1205 +))) 885 885 |(% style="width:173px" %)HMI station number|(% style="width:122px" %)HSW10129|(% colspan="2" style="width:506px" %) 886 886 |(% style="width:173px" %)PLC station number|(% style="width:122px" %)HSW10130|(% colspan="2" style="width:506px" %) 887 887 |(% colspan="1" rowspan="11" style="width:102px" %)COM2|(% style="width:173px" %)Communication mode|(% style="width:122px" %)HSW10072|(% colspan="2" style="width:506px" %)((( ... ... @@ -912,10 +912,22 @@ 912 912 * =1: ODD 913 913 * =2: EVEN 914 914 ))) 915 -|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10077|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000 916 -|(% style="width:173px" %)receive timeout|(% style="width:122px" %)HSW10078|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000 917 -|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10079|(% colspan="2" style="width:506px" %)Unit: times. Range: 0~~100 918 -|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10080|(% colspan="2" style="width:506px" %)Unit: s. Range: 0~~30 1236 +|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10077|(% colspan="2" style="width:506px" %)((( 1237 +* Unit: ms. 1238 +* Range: 0 to 30000 1239 +))) 1240 +|(% style="width:173px" %)receive timeout|(% style="width:122px" %)HSW10078|(% colspan="2" style="width:506px" %)((( 1241 +* Unit: ms. 1242 +* Range: 0 to 30000 1243 +))) 1244 +|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10079|(% colspan="2" style="width:506px" %)((( 1245 +* Unit: times. 1246 +* Range: 0 to 100 1247 +))) 1248 +|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10080|(% colspan="2" style="width:506px" %)((( 1249 +* Unit: s. 1250 +* Range: 0 to 30 1251 +))) 919 919 |(% style="width:173px" %)HMI station number|(% style="width:122px" %)HSW10081|(% colspan="2" style="width:506px" %) 920 920 |(% style="width:173px" %)PLC station number|(% style="width:122px" %)HSW10082|(% colspan="2" style="width:506px" %) 921 921 |(% colspan="1" rowspan="11" style="width:102px" %)COM2-2|(% style="width:173px" %)Communication mode|(% style="width:122px" %)HSW10105|(% colspan="2" style="width:506px" %)((( ... ... @@ -946,10 +946,22 @@ 946 946 * =1: ODD 947 947 * =2: EVEN 948 948 ))) 949 -|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10110|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000 950 -|(% style="width:173px" %)receive timeout|(% style="width:122px" %)HSW10111|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000 951 -|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10112|(% colspan="2" style="width:506px" %)Unit: times. Range: 0~~100 952 -|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10113|(% colspan="2" style="width:506px" %)Unit: s. Range: 0~~30 1282 +|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10110|(% colspan="2" style="width:506px" %)((( 1283 +* Unit: ms. 1284 +* Range: 0 to 30000 1285 +))) 1286 +|(% style="width:173px" %)receive timeout|(% style="width:122px" %)HSW10111|(% colspan="2" style="width:506px" %)((( 1287 +* Unit: ms. 1288 +* Range: 0 to 30000 1289 +))) 1290 +|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10112|(% colspan="2" style="width:506px" %)((( 1291 +* Unit: times. 1292 +* Range: 0 to 100 1293 +))) 1294 +|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10113|(% colspan="2" style="width:506px" %)((( 1295 +* Unit: s. 1296 +* Range: 0 to 30 1297 +))) 953 953 |(% style="width:173px" %)HMI station number|(% style="width:122px" %)HSW10114|(% colspan="2" style="width:506px" %) 954 954 |(% style="width:173px" %)PLC station number|(% style="width:122px" %)HSW10115|(% colspan="2" style="width:506px" %) 955 955 |(% colspan="1" rowspan="11" style="width:102px" %)COM3|(% style="width:173px" %)Communication mode|(% style="width:122px" %)HSW10083|(% colspan="2" style="width:506px" %)((( ... ... @@ -979,29 +979,48 @@ 979 979 * =1: ODD 980 980 * =2: EVEN 981 981 ))) 982 -|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10088|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000 983 -|(% style="width:173px" %)receive timeout|(% style="width:122px" %)HSW10089|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000 984 -|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10090|(% colspan="2" style="width:506px" %)Unit: times. Range: 0~~100 985 -|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10091|(% colspan="2" style="width:506px" %)Unit: s. Range: 0~~30 1327 +|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10088|(% colspan="2" style="width:506px" %)((( 1328 +* Unit: ms. 1329 +* Range: 0 to 30000 1330 +))) 1331 +|(% style="width:173px" %)receive timeout|(% style="width:122px" %)HSW10089|(% colspan="2" style="width:506px" %)((( 1332 +* Unit: ms. 1333 +* Range: 0 to 30000 1334 +))) 1335 +|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10090|(% colspan="2" style="width:506px" %)((( 1336 +* Unit: times. 1337 +* Range: 0 to 100 1338 +))) 1339 +|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10091|(% colspan="2" style="width:506px" %)((( 1340 +* Unit: s. 1341 +* Range: 0 to 30 1342 +))) 986 986 |(% style="width:173px" %)HMI station number|(% style="width:122px" %)HSW10092|(% colspan="2" style="width:506px" %) 987 987 |(% style="width:173px" %)PLC station number|(% style="width:122px" %)HSW10093|(% colspan="2" style="width:506px" %) 988 988 |(% colspan="1" rowspan="2" style="width:102px" %)CAN port|(% style="width:173px" %)CAN1 baud rate|(% style="width:122px" %)HSW010116|(% style="width:299px" %)((( 989 -Unit: K, the baud rate must be an integer, for example, when the baud rate required is 250000, just enter 250. 1346 +Unit: K, the baud rate must be an integer. 1347 + 1348 +For example, when the baud rate required is 250000, just enter 250. 990 990 )))|(% colspan="1" rowspan="2" style="width:218px" %)**✎Note: **If baud rate has been modified,please wait 5 seconds,then restart the HMI to take effect. 991 -|(% style="width:173px" %)CAN2 baud rate|(% style="width:122px" %)HSW010117|(% style="width:299px" %)Unit: K, the baud rate must be an integer, for example, when the baud rate required is 250000, just enter 250. 1350 +|(% style="width:173px" %)CAN2 baud rate|(% style="width:122px" %)HSW010117|(% style="width:299px" %)((( 1351 +Unit: K, the baud rate must be an integer. 992 992 993 -== **Ethernet communication configuration** == 1353 +For example, when the baud rate required is 250000, just enter 250. 1354 +))) 994 994 1356 +== Ethernet communication configuration == 1357 + 995 995 (% class="table-bordered" %) 996 -| =(% style="width:;" %)**No.**|=(% style="width:;" %)**Function**|=(% style="width:;" %)**Address**|=(% style="width:;" %)**Description**1359 +|(% style="width:40px" %)**No.**|(% style="width:295px" %)**Function**|(% style="width:220px" %)**Address**|(% style="width:336px" %)**Description** 997 997 |(% rowspan="7" style="width:40px" %)1|(% colspan="1" rowspan="7" style="width:295px" %)Ethernet parameter configuration for communication number 1 in list. Configure those addresses according to connected device. After configuration, wait for 5 seconds and restart the HMI.|(% style="width:220px" %)HSW11004|(% style="width:336px" %)Device IP address high word 1 998 998 |(% style="width:220px" %)HSW11005|(% style="width:336px" %)Device IP address high word 2 999 999 |(% style="width:220px" %)HSW11006|(% style="width:336px" %)Device IP address high word 3 1000 1000 |(% style="width:220px" %)HSW11007|(% style="width:336px" %)Device IP address high word 4 1001 1001 |(% style="width:220px" %)HSW11008|(% style="width:336px" %)Device Port number 1002 -|(% style="width:220px" %)HSW11009|=(% style="width: 336px;" %)((( 1003 -* =2 TCP 1004 -* =3 UDP 1365 +|(% style="width:220px" %)HSW11009|(% style="width:336px" %)((( 1366 +~=2 TCP 1367 + 1368 +~=3 UDP 1005 1005 ))) 1006 1006 |(% style="width:220px" %)HSW11010|(% style="width:336px" %)Reserved 1007 1007 |(% rowspan="7" style="width:40px" %)2|(% colspan="1" rowspan="7" style="width:295px" %)Ethernet parameter configuration for communication number 2 in list. Configure those addresses according to connected device. After configuration, wait for 5 seconds and restart the HMI.|(% style="width:220px" %)HSW11011|(% style="width:336px" %)Device IP address high word 1 ... ... @@ -1009,9 +1009,10 @@ 1009 1009 |(% style="width:220px" %)HSW11013|(% style="width:336px" %)Device IP address high word 3 1010 1010 |(% style="width:220px" %)HSW11014|(% style="width:336px" %)Device IP address high word 4 1011 1011 |(% style="width:220px" %)HSW11015|(% style="width:336px" %)Device Port number 1012 -|(% style="width:220px" %)HSW11016|=(% style="width: 336px;" %)((( 1013 -* =2 TCP 1014 -* =3 UDP 1376 +|(% style="width:220px" %)HSW11016|(% style="width:336px" %)((( 1377 +~=2 TCP 1378 + 1379 +~=3 UDP 1015 1015 ))) 1016 1016 |(% style="width:220px" %)HSW11017|(% style="width:336px" %)Reserved 1017 1017 |(% style="width:40px" %)…|(% style="width:295px" %) |(% style="width:220px" %)…|(% style="width:336px" %)… ... ... @@ -1020,7 +1020,11 @@ 1020 1020 |(% style="width:220px" %)HSW11223|(% style="width:336px" %)Device IP address high word 3 1021 1021 |(% style="width:220px" %)HSW11224|(% style="width:336px" %)Device IP address high word 4 1022 1022 |(% style="width:220px" %)HSW11225|(% style="width:336px" %)Device Port number 1023 -|(% style="width:220px" %)HSW11226|=(% style="width: 336px;" %)2 TCP; =3 UDP 1388 +|(% style="width:220px" %)HSW11226|(% style="width:336px" %)((( 1389 +~=2 TCP; 1390 + 1391 +~=3 UDP 1392 +))) 1024 1024 |(% style="width:220px" %)HSW11227|(% style="width:336px" %)Reserved 1025 1025 1026 1026 (% class="box infomessage" %) ... ... @@ -1028,7 +1028,7 @@ 1028 1028 **✎Note:** The number of Ethernet connections supported by different HMI series varies. 1029 1029 ))) 1030 1030 1031 -== **Communication control**==1400 +== Communication control == 1032 1032 1033 1033 (% class="table-bordered" %) 1034 1034 |=(% style="width: 135px;" %)**Communication No.**|=(% style="width: 102px;" %)**Station No.**|=(% style="width: 185px;" %)**Control bit**|=(% style="width: 191px;" %)**Communication lamp**|=(% style="width: 271px;" %)**Description**