... ... @@ -4,11 +4,11 @@
4 4  
5 5  *HSW, HDW, HUW, HAW are word address, HSX, HDX, HUX, HAX are bit address.
6 6  
7 -1. **System data area (HSW): **A special register defined by the system.
8 -1. **Data storage area (HDW/HDX): **Users store user data.
9 -1. **System data area (HUW): **A special register defined by the system.
10 -1. **System Data (HAW)**: System register used for power-off save.
11 -1. **Recipe index area (RPW): **System register used for recipe index.
7 +* **System data area (HSW): **A special register defined by the system.
8 +* **Data storage area (HDW/HDX): **Users store user data.
9 +* **System data area (HUW): **A special register defined by the system.
10 +* **System Data (HAW)**: System register used for power-off save.
11 +* **Recipe index area (RPW): **System register used for recipe index.
12 12  
13 13  HMI internal registers are divided into bit address and word address, which can be accessed in two ways (take HDW as an example).
14 14  
... ... @@ -644,20 +644,20 @@
644 644  * =2: enter the background
645 645  )))
646 646  |=(% style="width: 160px;" %)HSW1866|(% style="width:282px" %)Delete the LUa extension module file|(% style="width:452px" %)(((
647 -* =1, delete;
648 -* = Others, do not delete
647 +* =0: delete;
648 +* = Others: do not delete
649 649  )))
650 650  |=(% style="width: 160px;" %)HSW1867|(% style="width:282px" %)Reset mode|(% style="width:452px" %)(((
651 651  Monitor address is set during reset of reset switch, whether to cancel reset,
652 652  
653 -* = 0, yes (default);
654 -* = 1, no
653 +* = 0: yes (default);
654 +* = 1: no
655 655  )))
656 656  |=(% style="width: 160px;" %)HSW1868|(% style="width:282px" %)Double-click or long press the record type table mode|(% style="width:452px" %)(((
657 657  Controls whether the button pops up when double-clicking or long pressing on record type table object
658 658  
659 -* = 0, yes (default);
660 -* = 1, no
659 +* = 0: yes (default);
660 +* = 1: no
661 661  )))
662 662  |=(% style="width: 160px;" %)HSW10000~~19999|(% style="width:282px" %)Power-down storage area|(% style="width:452px" %)After restart, the data remains
663 663  |=(% style="width: 160px;" %)HSW10035|(% rowspan="13" style="width:282px" %)(((
... ... @@ -773,7 +773,7 @@
773 773  |=(% style="width: 160px;" %)HSW11760|(% style="width:282px" %)Screensaver countdown|(% style="width:452px" %)Display the countdown to enter the Screensaver, unit: second.
774 774  |=(% style="width: 160px;" %)HSW11761|(% style="width:282px" %)Screensaver screen number|(% style="width:452px" %)Set the screen number for Screensaver
775 775  
776 -== **Serial port communication configuration** ==
776 +== Serial port communication configuration ==
777 777  
778 778  (% class="table-bordered" %)
779 779  |=(% scope="row" style="width: 102px;" %)Port|=(% style="width: 173px;" %)**Function**|=(% style="width: 122px;" %)**Address**|=(% colspan="2" style="width: 506px;" %)**Description**
... ... @@ -1068,18 +1068,19 @@
1068 1068  For example, when the baud rate required is 250000, just enter 250.
1069 1069  )))
1070 1070  
1071 -== **Ethernet communication configuration** ==
1071 +== Ethernet communication configuration ==
1072 1072  
1073 1073  (% class="table-bordered" %)
1074 -|=(% style="width: 40px;" %)**No.**|=(% style="width: 295px;" %)**Function**|=(% style="width: 220px;" %)**Address**|=(% style="width: 336px;" %)**Description**
1074 +|(% style="width:40px" %)**No.**|(% style="width:295px" %)**Function**|(% style="width:220px" %)**Address**|(% style="width:336px" %)**Description**
1075 1075  |(% rowspan="7" style="width:40px" %)1|(% colspan="1" rowspan="7" style="width:295px" %)Ethernet parameter configuration for communication number 1 in list. Configure those addresses according to connected device. After configuration, wait for 5 seconds and restart the HMI.|(% style="width:220px" %)HSW11004|(% style="width:336px" %)Device IP address high word 1
1076 1076  |(% style="width:220px" %)HSW11005|(% style="width:336px" %)Device IP address high word 2
1077 1077  |(% style="width:220px" %)HSW11006|(% style="width:336px" %)Device IP address high word 3
1078 1078  |(% style="width:220px" %)HSW11007|(% style="width:336px" %)Device IP address high word 4
1079 1079  |(% style="width:220px" %)HSW11008|(% style="width:336px" %)Device Port number
1080 -|(% style="width:220px" %)HSW11009|=(% style="width: 336px;" %)(((
1081 -* =2 TCP
1082 -* =3 UDP
1080 +|(% style="width:220px" %)HSW11009|(% style="width:336px" %)(((
1081 +~=2 TCP
1082 +
1083 +~=3 UDP
1083 1083  )))
1084 1084  |(% style="width:220px" %)HSW11010|(% style="width:336px" %)Reserved
1085 1085  |(% rowspan="7" style="width:40px" %)2|(% colspan="1" rowspan="7" style="width:295px" %)Ethernet parameter configuration for communication number 2 in list. Configure those addresses according to connected device. After configuration, wait for 5 seconds and restart the HMI.|(% style="width:220px" %)HSW11011|(% style="width:336px" %)Device IP address high word 1
... ... @@ -1087,9 +1087,10 @@
1087 1087  |(% style="width:220px" %)HSW11013|(% style="width:336px" %)Device IP address high word 3
1088 1088  |(% style="width:220px" %)HSW11014|(% style="width:336px" %)Device IP address high word 4
1089 1089  |(% style="width:220px" %)HSW11015|(% style="width:336px" %)Device Port number
1090 -|(% style="width:220px" %)HSW11016|=(% style="width: 336px;" %)(((
1091 -* =2 TCP
1092 -* =3 UDP
1091 +|(% style="width:220px" %)HSW11016|(% style="width:336px" %)(((
1092 +~=2 TCP
1093 +
1094 +~=3 UDP
1093 1093  )))
1094 1094  |(% style="width:220px" %)HSW11017|(% style="width:336px" %)Reserved
1095 1095  |(% style="width:40px" %)…|(% style="width:295px" %) |(% style="width:220px" %)…|(% style="width:336px" %)…
... ... @@ -1098,7 +1098,11 @@
1098 1098  |(% style="width:220px" %)HSW11223|(% style="width:336px" %)Device IP address high word 3
1099 1099  |(% style="width:220px" %)HSW11224|(% style="width:336px" %)Device IP address high word 4
1100 1100  |(% style="width:220px" %)HSW11225|(% style="width:336px" %)Device Port number
1101 -|(% style="width:220px" %)HSW11226|=(% style="width: 336px;" %)2 TCP; =3 UDP
1103 +|(% style="width:220px" %)HSW11226|(% style="width:336px" %)(((
1104 +~=2 TCP;
1105 +
1106 +~=3 UDP
1107 +)))
1102 1102  |(% style="width:220px" %)HSW11227|(% style="width:336px" %)Reserved
1103 1103  
1104 1104  (% class="box infomessage" %)
... ... @@ -1106,7 +1106,7 @@
1106 1106  **✎Note:** The number of Ethernet connections supported by different HMI series varies.
1107 1107  )))
1108 1108  
1109 -== **Communication control** ==
1115 +== Communication control ==
1110 1110  
1111 1111  (% class="table-bordered" %)
1112 1112  |=(% style="width: 135px;" %)**Communication No.**|=(% style="width: 102px;" %)**Station No.**|=(% style="width: 185px;" %)**Control bit**|=(% style="width: 191px;" %)**Communication lamp**|=(% style="width: 271px;" %)**Description**